Incorporating a statistically based shape model into a system for computer-assisted anterior cruciate ligament surgery.
Med Image Anal
; 3(3): 209-22, 1999 Sep.
Article
en En
| MEDLINE
| ID: mdl-10710292
This paper addresses the problem of extrapolating very sparse three-dimensional (3-D) data to obtain a complete surface representation. A new method that uses statistical shape models is proposed and its application to computer-assisted anterior cruciate ligament (ACL) reconstruction is detailed. The rupture of the ACL has become one of the most common knee injuries. One problem during reconstruction is to find the optimal attachment points for the graft. Therefore a system for computer-assisted reconstruction of the ACL has been proposed by TIMC laboratory. During surgery the surgeon collects several data points on the tibial and femoral joint surface with a 3-D localizer system. These 3-D data are used to find those attachment points resulting in a low anisometry of the graft, while preventing impingement between the graft and the femoral notch. As the collected data points only cover a small surface patch of the femur, it is desirable to extrapolate these data to also have a visualization in those areas where no data points are available. A sufficiently good approximation of the actual femur by the model would further allow us to better deal with the notch impingement problem of the graft. The chosen approach is to fit a deformable model to the data points, it can be subdivided into two steps, constructing the model and fitting this model to the data. To incorporate a priori knowledge into the model, the allowed deformations are determined by the statistics of the shape variation of a set of training objects. Matching the training objects together is obtained by elastic registration of surface points using octree splines. The fitting process of the sparse intra-operative data with the statistical model results in a non-linear multi-dimensional function minimization. A hybrid search strategy combining local and global methods is used to avoid local minima. First experimental results with a model generated from 10 femurs are presented, including fitting of the model with both simulated and real intra-operative data.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Simulación por Computador
/
Procesamiento de Imagen Asistido por Computador
/
Terapia Asistida por Computador
/
Modelos Estadísticos
/
Ligamento Cruzado Anterior
Tipo de estudio:
Diagnostic_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Humans
Idioma:
En
Revista:
Med Image Anal
Asunto de la revista:
DIAGNOSTICO POR IMAGEM
Año:
1999
Tipo del documento:
Article
País de afiliación:
Francia
Pais de publicación:
Países Bajos