Your browser doesn't support javascript.
loading
Dacron graft intussusception technique for treatment of type a aortic dissections: technical notes and preliminary results
Pinheiro, Bruno Botelho; Fagundes, Walter V; Muniz, Luís F F; Dreifaldt, Mats; Arbeus, Mikael; Souza, Domingos S R.
Afiliación
  • Pinheiro, Bruno Botelho; Clinicord. Serviço de Cirurgia Cardiovascular. Goiânia. BR
  • Fagundes, Walter V; Clinicord. Serviço de Cirurgia Cardiovascular. Goiânia. BR
  • Muniz, Luís F F; Clinicord. Serviço de Cirurgia Cardiovascular. Goiânia. BR
  • Dreifaldt, Mats; Clinicord. Serviço de Cirurgia Cardiovascular. Goiânia. BR
  • Arbeus, Mikael; Clinicord. Serviço de Cirurgia Cardiovascular. Goiânia. BR
  • Souza, Domingos S R; Clinicord. Serviço de Cirurgia Cardiovascular. Goiânia. BR
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;31(2): 115-119, Mar.-Apr. 2016. tab, graf
Article en En | LILACS | ID: lil-792655
Biblioteca responsable: BR1.1
ABSTRACT
Abstract

Introduction:

Optimal surgical management for acute type A aortic dissection (AAAD) remains unclear. The in-hospital mortality rate is still high (15%), and the intraoperative bleeding is an independent risk factor for hospital mortality.

Objective:

The aim of our study was describe a new method for aortic anastomosis in the repair of AAAD and report the hospital mortality and bleeding complications.

Methods:

Between January 2008 and November 2014, 24 patients, 16 male, median age 62 years, underwent surgical treatment of AAAD. The surgical technique consisted of intussusception of a Dacron tube in the dissected aorta, which is anastomosed with a first line of 2-0 polyester everting mattress suture and a second line of 3-0 polypropylene running suture placed at the outermost side. Open distal anastomosis was performed with bilateral selective antegrade cerebral perfusion in 13 (54.1%) patients.

Results:

Cardiopulmonary bypass and aortic clamping time ranged from 75 to 135 min (mean=85 min) and 60 to 100 min (mean=67 min), respectively. The systemic circulatory arrest ranged from 29 to 60 min (mean=44.5 min). One (4.1%) patient required reoperation for bleeding, due to the use of preoperative clopidogrel. The postoperative bleeding was 382-1270 ml (mean=654 ml). We used an average of 4.2 units of red blood cells/patient. There were two (8.3%) hospital deaths, one due to intraoperative bleeding and another due to mesenteric ischemia. The average length of stay in the intensive care unit and hospital was 44 hours and 6.7 days, respectively.

Conclusion:

This new method for surgical correction of AAAD was reproducible and resulted in satisfactory clinical outcomes.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: LILACS Asunto principal: Aneurisma de la Aorta / Hemorragia Posoperatoria / Implantación de Prótesis Vascular / Disección Aórtica Tipo de estudio: Clinical_trials / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male País/Región como asunto: America do sul / Brasil / Europa Idioma: En Revista: Rev. bras. cir. cardiovasc Asunto de la revista: CARDIOLOGIA / CIRURGIA GERAL Año: 2016 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: LILACS Asunto principal: Aneurisma de la Aorta / Hemorragia Posoperatoria / Implantación de Prótesis Vascular / Disección Aórtica Tipo de estudio: Clinical_trials / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male País/Región como asunto: America do sul / Brasil / Europa Idioma: En Revista: Rev. bras. cir. cardiovasc Asunto de la revista: CARDIOLOGIA / CIRURGIA GERAL Año: 2016 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Brasil