Your browser doesn't support javascript.
loading
Desarrollo y validación de un método verde para la extracion y cuantificación de residuos de cipermetrina en tejido animal / Fevelopment and validation of green method for the extraction and quantification of cypermethrin residues in animal tissue / Desenvolvimento e validação do método verde para a extração e quantificação dos resíduos da cipermetrina no tecido animal
Chaparro, Amanda L; Gamboa, Diana P; Cardona, Yaneth; Bustamante, John J; García, Carlos H.
Afiliación
  • Chaparro, Amanda L; Universidad de Pamplona. Pamplona. CO
  • Gamboa, Diana P; Universidad de Pamplona. Pamplona. CO
  • Cardona, Yaneth; Universidad de Pamplona. Pamplona. CO
  • Bustamante, John J; Universidad de Pamplona. Pamplona. CO
  • García, Carlos H; Universidad de Pamplona. Pamplona. CO
Rev. colomb. quím. (Bogotá) ; 43(1): 1-1, ene.-jun. 2014. ilus, tab
Article en Es | LILACS | ID: lil-747657
Biblioteca responsable: CO332
RESUMEN
En este trabajo se desarrolló y validó un método simple, ambientalmente amigable y efectivo, para la extracción y cuantificación de cipermetrina en muestras de bovino (hígado, grasa perirrenal y músculo) utilizando dispersión de matriz en fase sólida (MSPD) y cromatografía de gases con detector de ionización de llama (GC-FID). Diferentes parámetros del método se evaluaron, tales como el dispersante, solvente de extracción y volumen de solvente. Los mejores resultados para la extracción de cipermetrina por MSPD fueron 0,20 g de muestra macerados con 0,80 g de silica gel y extraídos con 5,00 mL de acetona. El procedimiento propuesto fue validado mostrando comportamiento lineal en el intervalo de 10,20-400,40 µg/L (R²=0,9988). Los límites de detección y cuantificación fueron 2,00 y 5,70 µg/L respectivamente, con una desviación estándar relativa de 0,0875 (n=5). Este método permite determinar cipermetrina hasta niveles traza en muestras de tejido animal, con una recuperación de 98,96%.
ABSTRACT
In the present study a simple, effective and environmentally friendly method was developed and validated for the extraction and quantification of cypermethrin in animal tissue (meat, fat and liver) based on matrix solid-phase dispersion (MSPD) and gas chromatography with flame ionization detector (GC-FID). Different parameters of the method were evaluated, such as dispersant, extractive solvent and solvent volume. The best results for the extraction of cypermethrin by MSPD were 0.20 g of sample with 0.80 g of silica gel and 5.00 mL of acetone as eluting solvent. The proposed procedure was validated showing linear behavior in the interval of 10.20 to 400.40 µg/L (R²= 0.9988). Detection and quantification limits ranged from 2.00 and 5.70 µg/L respectively, with a standard deviation of 0.0875 (n=5). This method enables to determine cypermethrin at trace level in animal tissue samples, with a recovery of 98.96%.
RESUMO
Neste trabalho foi desenvolvido e validado um método verde para extração e quantificação de cipermetrina em amostras de fígado, gordura perirrenal e músculo em gado bovino, por meio da técnica de dispersão de matriz em fase solida (MSPD) e cromatografia de gases com detecção de ionização de chama (GC-FID). Foram avaliados diferentes parâmetros do método, como dispersante, extração com solvente e volume de solvente. Os melhores resultados para a extracção da cipermetrina por MSPD foram 0.20 g da amostra macerada com 0.80 g de gel de sílica e extraiu-se com 5.00 mL de acetona. O método proposto foi validada mostrando um comportamento linear na gama testada (10.20-400.40 µg/L) com R² de 0.9988. Os limites de detecção e de quantificação foram 2.00 e 5.70 µg/L, respectivamente, com um desvio padrão de 0.0875 (n = 5). O método proposto neste trabalho permitiu determinar níveis traça da cipermetrina em amostras de tecidos animai, com uma recuperação de 98.96%.
Palabras clave
Texto completo: 1 Colección: 01-internacional Base de datos: LILACS Idioma: Es Revista: Rev. colomb. quím. (Bogotá) Asunto de la revista: QUIMICA Año: 2014 Tipo del documento: Article País de afiliación: Colombia Pais de publicación: Colombia
Texto completo: 1 Colección: 01-internacional Base de datos: LILACS Idioma: Es Revista: Rev. colomb. quím. (Bogotá) Asunto de la revista: QUIMICA Año: 2014 Tipo del documento: Article País de afiliación: Colombia Pais de publicación: Colombia