Análise de um radioimunoensaio iodado para determinação de 11-deoxicortisol / Analysis of an iodide radioimmunoassay for 11-deoxicortisol measurement
Arq. bras. endocrinol. metab
; Arq. bras. endocrinol. metab;58(3): 232-236, abr. 2014. graf
Article
en Pt
| LILACS
| ID: lil-709345
Biblioteca responsable:
BR1.1
RESUMO
Objetivo:
Nosso objetivo foi comparar duas técnicas de dosagem do 11-desoxicortisol a técnica de radioimunoensaio iodado, a qual foi validada neste trabalho, e a cromatografia líquida de alta performance seguida por espectrometria de massa em tandem (LC-MS/MS), sendo a última considerada o padrão-ouro para dosagem dos hormônios esteroides.Materiais e métodos:
Para a comparação entre os resultados de 11-desoxicortisol, foram selecionadas 88 amostras.Resultados:
A sensibilidade analítica do radioimunoensaio foi de 0,30 ng/mL, com linearidade e perfil de precisão inadequado (34% das amostras com CV ≥ 20%). Das 88 amostras selecionadas, apenas 54 apresentaram resultados mensuráveis em ambos os métodos. A comparação desses resultados, por meio da regressão de Deming, resultou em um coeficiente de correlação de 0,610, inclinação de 3,751, intercepção de 0,145, evidenciando a pobre correlação entre os resultados e a superestimação dos resultados pelo RIA.Conclusão:
Concluímos que o método de dosagem de 11-desoxicortisol por radioimunoensaio iodado apresentou resultados inadequados nos diversos parâmetros avaliados, inviabilizando sua utilização como método de dosagem do 11-desoxicortisol. Arq Bras Endocrinol Metab. 2014;58(3)232-6 .ABSTRACT
Objective:
Our aim was to correlate 11-deoxycortisol levels obtained by two currently available techniques for 11-deoxycortisol measurement radioimmunoassay, and high performance liquid chromatography followed by tandem mass spectrometry (MS/MS). The latter is the gold standard method for steroid hormone measurement. Materials andmethods:
We selected 88 samples and the results of these two methods were compared by Deming regression.Results:
The analytical sensitivity of the RIA was 0.30 ng/mL, with inadequate linearity and inadequate precision profile (34% of the samples had a CV ≥ 20%). From the selected samples, 54 had measurable levels of 11-deoxycortisol in both methods and were used in the comparison. The comparison of RIA with LC-MS/MS showed an overestimation of the results by RIA. The correlation coefficient was 0.610; linear regression slope was 3.751; and the intercept was 0.145, indicating a poor correlation between the two methods.Conclusion:
We concluded that 11-deoxycortisol measured by radioimmunoassay, despite a good analytical sensitivity, showed very low specificity, precluding its use as a reliable method for 11-deoxycortisol measurement. Arq Bras Endocrinol Metab. 2014;58(3)232-6 .Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
LILACS
Asunto principal:
Juego de Reactivos para Diagnóstico
/
Hiperplasia Suprarrenal Congénita
/
Cortodoxona
/
Radioisótopos de Yodo
Tipo de estudio:
Diagnostic_studies
Límite:
Humans
Idioma:
Pt
Revista:
Arq. bras. endocrinol. metab
Asunto de la revista:
Endocrinologia
/
Metabolismo
Año:
2014
Tipo del documento:
Article
/
Project document
País de afiliación:
Brasil
Pais de publicación:
Brasil