Osteointegração da hidroxiapatita sintética no processo alveolar da mandíbula de cães: aspectos clínicos e radiográficos / Osteointegration of synthetic hydroxyapatite in alveolar process of the jaw of dogs: clinical and radiographic aspects
Arq. bras. med. vet. zootec
; Arq. bras. med. vet. zootec. (Online);59(1): 114-118, fev. 2007. ilus
Article
en Pt
| LILACS
| ID: lil-456423
Biblioteca responsable:
BR68.1
RESUMO
Avaliou-se o efeito da hidroxiapatita sintética na regeneração do osso alveolar e o efeito no tecido vivo de cães. Em dois grupos de 14 cães adultos hígidos, pesando entre 10 e 15kg, foram criados defeitos de 6 x 5mm na superfície vestibular do processo alveolar mandibular direito até atingir a raiz do quarto pré-molar. Em um grupo (tratado), o defeito foi preenchido com hidroxiapatita sintética; o grupo sem tratamento foi usado como controle. Efetuaram-se avaliações clínicas diárias durante uma semana, avaliações radiográficas após a cirurgia e aos oito, 21, 42, 60, 90 e 120 dias do pós-operatório. Vinte e quatro cães apresentaram inflamação, sendo a recuperação no grupo tratado mais lenta. Todos os animais tiveram sangramento com a hidroxiapatita. No grupo-controle houve aumento crescente da radiopacidade dos defeitos, no entanto, aos 120 dias do pós-operatório, os defeitos ainda eram visíveis. No grupo tratado, inicialmente a radiopacidade foi maior que a do osso normal, com diminuição gradual até se tornar semelhante à do osso vizinho, 60 dias após a cirurgia. A hidroxiapatita T290800-1 acelerou o preenchimento do defeito provocado no processo alveolar e acarretou inflamação e hemorragia gengival, o que, no entanto, não contra-indicou o seu uso.
ABSTRACT
The effect of the synthetic hydroxyapatite on the regeneration of the alveolar bone of dogs and on the alive tissue were evaluated. In two groups of 14 adult healthy dogs, weighing from 10 to 15kg, some defects around 6 x 5mm were provoked on the vestibular surface of the right jaw alveolar process until reaching the root of the forth premolar. In one group, the defect was infilled with synthetic hydroxyapatite. The no treated group dogs were used as control. Clinical evaluations were daily performed over one week, as well as radiographic evaluations after surgery, and on 8, 21, 42, 60, 90 and 120 days after surgery. Twenty-four dogs showed inflammation and the recovery in the treated group was slower than in the control group. Bleeding at the presence of hydroxyapatite was observed in all the animals. The radiographic examination presented an increasing radiopacity in the control group; however, this defect was still visible on day 120 after operation. Initially, in the treated group, radiopacity was higher than that of the normal bone and a gradual decrease occurred until becoming similar to the adjacent bone on day 60 days after surgery. The hydroxyapatite T290800-1 accelerated the infilling of the defect provoked in the alveolar process and caused gingival inflammation and hemorrhage; however, this does not contraindicate its use.
Texto completo:
1
Colección:
01-internacional
Base de datos:
LILACS
Asunto principal:
Trasplante Autólogo
/
Durapatita
/
Implantación de Prótesis Mandibular
/
Perros
/
Proceso Alveolar
Límite:
Animals
Idioma:
Pt
Revista:
Arq. bras. med. vet. zootec
/
Arq. bras. med. vet. zootec. (Online)
Asunto de la revista:
MEDICINA VETERINARIA
Año:
2007
Tipo del documento:
Article
País de afiliación:
Brasil
Pais de publicación:
Brasil