Comparison of an open view autorefractor with an open view aberrometer in determining peripheral refraction in children
Demir, Pelsin; Macedo, Antonio Filipe; Chakraborty, Ranjay; Baskaran, Karthikeyan.
Afiliación
  • Demir, Pelsin; Linnaeus University. Department of Medicine and Optometry. Kalmar. Sweden
  • Macedo, Antonio Filipe; Linnaeus University. Department of Medicine and Optometry. Kalmar. Sweden
  • Chakraborty, Ranjay; Flinders University. College of Nursing and Health Sciences, Optometry and Vision Science. Adelaide. Australia
  • Baskaran, Karthikeyan; Linnaeus University. Department of Medicine and Optometry. Kalmar. Sweden
J. optom. (Internet) ; 16(1)January - March 2023. ilus, tab, graf
Article en En | IBECS | ID: ibc-214427
Biblioteca responsable: ES1.1
Ubicación: ES15.1 - BNCS
ABSTRACT
Purpose: The aim of this study was to compare central and peripheral refraction using an open view Shin-Nippon NVision-K 5001 autorefractor and an open view COAS-HD VR aberrometer in young children.MethodsCycloplegic central and peripheral autorefraction was measured in the right eye of 123 children aged 8 to 16 years. Three measurements each were obtained with both Shin-Nippon NVision-K 5001 autorefractor and COAS-HD VR aberrometer along the horizontal visual field up to 30° (nasal and temporal) in 10° steps. The refraction from the autorefractor was compared with aberrometer refraction for pupil analysis diameters of 2.5-mm and 5.0-mm.ResultsThe Shin-Nippon was 0.30 D more hyperopic than COAS-HD VR at 2.5-mm pupil and 0.50 D more hyperopic than COAS-HD VR at 5-mm pupil for central refraction. For both pupil sizes, the 95% limits of agreement were approximately 0.50 D for central refraction, and limits were wider in the nasal visual field compared to the temporal visual field. The mean difference for both J0 and J45 were within 0.15 D and the 95% limits of agreement within 0.90 D across the horizontal visual field.ConclusionDefocus components were similar between the Shin-Nippon autorefractor and the COAS-HD VR aberrometer with a 2.5-mm pupil for most visual field angles. However, there was a significant difference in defocus component between the Shin-Nippon autorefractor and the COAS-HD VR aberrometer with a 5.0-mm pupil, wherein the autorefractor measured more hyperopia. The astigmatic components J0 and J45 were similar between instruments for both central and peripheral refraction. (AU)
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 06-national / ES Base de datos: IBECS Asunto principal: Refracción Ocular / Estudiantes / Preescolar / Hiperopía / Midriáticos Límite: Adolescent / Child / Humans Idioma: En Revista: J. optom. (Internet) Año: 2023 Tipo del documento: Article