Comparación biomecánica de la autoextracción con y sin collarín cervical: estudio de simulación / Self-extraction with and without a cervical collar: a biomechanical simulation study
Emergencias (Sant Vicenç dels Horts)
; 31(1): 36-38, feb. 2019. ilus, tab
Article
en Es
| IBECS
| ID: ibc-182434
Biblioteca responsable:
ES1.1
Ubicación: BNCS
RESUMEN
Objetivos: Comparar la autoextracción (AE) frente a la AE con collarines en sujetos con bajo riesgo de lesión cervical. Método: Estudio de simulación mediante análisis biomecánico con sensores inerciales, determinando la desalineación de la columna cervical durante la AE con y sin collarines cervicales. Resultados: El desequilibrio fue 3,12 (DE 34,62) grados mayor con el collarín STIFNECK (SN) (IC al 95% de -15,33 a 21,57; p =0,7234) que con AE y también 5,95 (DE 31,76) grados mayor con collarín X-COLLAR (XC) (IC al 95% de -10,98 a 22,87; p = 0,4654) que con AE. Cuando comparamos la AE con los diferentes tipos de collarines, observamos que con el collarín XC se produjeron 2,83 (DE 12,10) grados de desalineación más que con el collarín SN (IC al 95% de -3,62 a 9,27; p = 0,3650). Conclusiones: La desalineación de la columna cervical mediante la AE es similar a la provocada cuando se aplican collarines cervicales
ABSTRACT
Objective: To compare self-extraction with and without a cervical collar in subjects at low risk of cervical spine injuries. Methods: Simulation study analyzing biomechanical data from inertial sensors to detect misalignment of the cervical spine during self-extraction with and without a cervical collar. Results: Misalignment was a mean (SD) 3.12 (34.62) degrees greater during self-extraction with a Stiffneck collar in place (95% CI, -15.33 to 21.57 degrees; P=.7234) than during extraction without a collar. Misalignment was also greater, by 5.95 (31.76) degrees, with an X-collar in place (95% CI, -10.98 to 22.87; P=.4654) than without a collar. The between-collar comparison of differences showed that misalignment was 2.83 (12.10) degrees greater with the X-collar (95% CI, -3.62 to 9.27 degrees; P=.3650). Conclusion: Misalignment of the cervical spinal column is similar during self-extraction with or without a cervical collar in place
Texto completo:
1
Colección:
06-national
/
ES
Base de datos:
IBECS
Asunto principal:
Equipos de Seguridad
/
Traumatismos Vertebrales
/
Restricción Física
/
Accidentes de Tránsito
/
Vértebras Cervicales
/
Traumatismos del Cuello
Límite:
Adult
/
Female
/
Humans
/
Male
Idioma:
Es
Revista:
Emergencias (Sant Vicenç dels Horts)
Año:
2019
Tipo del documento:
Article