Valor pronóstico de la pulsioximetría nocturna en pacientes con insuficiencia cardiaca / Prognostic value of nocturnal pulse oximetry in patients with heart failure
Med. clín (Ed. impr.)
; 150(10): 383-386, mayo 2018. tab, graf
Article
en Es
| IBECS
| ID: ibc-173440
Biblioteca responsable:
ES1.1
Ubicación: BNCS
RESUMEN
Introducción y objetivos: Analizar el valor pronóstico de la hipoxemia nocturna, evaluada mediante pulsioximetría nocturna portátil, en pacientes ingresados por insuficiencia cardiaca y su relación con la mortalidad y el reingreso hospitalario. Métodos: Incluimos a 38 pacientes ingresados de manera consecutiva en nuestra unidad con el diagnóstico de insuficiencia cardiaca descompensada. La pulsioximetría se consideró positiva para hipoxemia cuando se registraron más de 10 desaturaciones a la hora durante el sueño. Se realizó seguimiento durante 30,3 (desviación estándar [DE] 14,2) meses, el objetivo principal fue un endpoint combinado de mortalidad por cualquier causa y reingreso por insuficiencia cardiaca. Resultados: La edad media fue de 70,7 (DE 10,7) años; el 63,3% eran varones. La pulsioximetría fue considerada positiva para hipoxemia en 27 (71%) pacientes. Los pacientes con una pulsioximetría positiva presentaron con mayor frecuencia el endpoint combinado (9.1% [1] vs. 61,5% [16]; p = 0,003). Tras el análisis multivariable, la hipoxemia nocturna continuó estando relacionada con el endpoint combinado (HR = 8,37; 1,19-68,4; p = 0,03). Discusión: Los pacientes ingresados por insuficiencia cardiaca e hipoxemia nocturna medida con pulsioxímetro portátil presentan un riesgo aumentado de reingreso y muerte
ABSTRACT
Introduction and objectives: To analyze the prognostic value of nocturnal hypoxemia measured with portable nocturnal pulse-oximetry in patients hospitalized due to heart failure and its relation to mortality and hospital readmission. Methods: We included 38 patients who were admitted consecutively to our unit with the diagnosis of decompensated heart failure. Pulse-oximetry was considered positive for hypoxemia when more than 10 desaturations per hour were recorded during sleep. Follow-up was performed for 30.3 (standard deviation [SD] 14.2) months, the main objective being a combined endpoint of all-cause mortality and hospital readmission due to heart failure. Results: The average age was 70.7 (SD 10.7) years, 63.3% were males. Pulse-oximetry was considered positive for hypoxemia in 27 (71%) patients. Patients with positive pulse-oximetry had the most frequent endpoint (9.1% [1] vs. 61.5% [16], P = 0.003). After multivariate analysis, continuous nocturnal hypoxemia was related to the combined endpoint (HR = 8.37, 1.19-68.4, P = 0.03). Discussion: Patients hospitalized for heart failure and nocturnal hypoxemia measured with portable pulse-oximeter have an increased risk of hospital readmission and death
Buscar en Google
Colección:
06-national
/
ES
Base de datos:
IBECS
Asunto principal:
Pulso Arterial
/
Monitoreo de Gas Sanguíneo Transcutáneo
/
Insuficiencia Cardíaca
Tipo de estudio:
Prognostic_studies
Límite:
Aged
/
Female
/
Humans
/
Male
Idioma:
Es
Revista:
Med. clín (Ed. impr.)
Año:
2018
Tipo del documento:
Article