Valoración isocinética en la artroplastia total de rodilla / Isokinetic assessment in total knee arthroplasty
Catasús Clavé, M. L; Díaz AristizÁbal, U; Nacenta Arias, F; Domínguez Pérez, M; Guillén Solá, A; Santín Paredes, J.
Afiliación
  • Catasús Clavé, M. L; Hospital Universitario de Bellvitge. L’Hospitalet de Llobregat. España
  • Díaz AristizÁbal, U; Hospital Universitario de Bellvitge. L’Hospitalet de Llobregat. España
  • Nacenta Arias, F; Hospital Universitario de Bellvitge. L’Hospitalet de Llobregat. España
  • Domínguez Pérez, M; Hospital Universitario de Bellvitge. L’Hospitalet de Llobregat. España
  • Guillén Solá, A; Hospital Universitario de Bellvitge. L’Hospitalet de Llobregat. España
  • Santín Paredes, J; Hospital Universitario de Bellvitge. L’Hospitalet de Llobregat. España
Rehabilitación (Madr., Ed. impr.) ; 39(1): 20-24, ene.-feb. 2005. tab, graf
Article en Es | IBECS | ID: ibc-037357
Biblioteca responsable: ES1.1
Ubicación: ES1.1 - BNCS
RESUMEN
Objetivos. Valorar la capacidad funcional de los pacientes a los que se ha implantado una prótesis total de rodilla al finalizar el tratamiento rehabilitador mediante una prueba isocinética y valorar la utilidad de éste como método complementario en el seguimiento de estos pacientes. Material y método. Se recogió una muestra de 16 pacientes de edades comprendidas entre los 61 y los 78 años, a los que se había implantado una prótesis total de rodilla, tras finalizar el tratamiento rehabilitador. Se comparó con un grupo control de 16 sujetos. Utilizamos un dinamómetro isocinético CYBEX NORM II. La prueba se realizó en régimen concéntrico, valorándose la fuerza máxima (peak torque), el conjunto del trabajo total(set total work), el ángulo de la fuerza y el cociente flexión/extensión de la fuerza, a velocidades angulares de 120 y 180°/s. Resultados. Se encontraron diferencias estadísticamente significativas (p 0,05) para el resto de los ángulos de fuerza máxima ni para las ratioflexión/extensión de fuerza máxima. Conclusiones. La valoración isocinética demuestra que estos pacientes presentan una pérdida de fuerza tanto de flexión como de extensión. La isocinesia es un método complementario útil para la valoración de estos pacientes; incluso puede ser útil para la adecuación individual de un protocolo establecido de rehabilitación, según las necesidades de cada paciente en cada etapa de tratamiento
ABSTRACT
Objectives. Assess the functional capacity of the patients who have received a total knee arthroplasty at the end of the rehabilitation treatment using an isokinetic test and assess the utility of this test as a complementary method in the follow-up of these patients. Material and method. We gathered a sample of 16 patients, whose ages ranged from 61 to 78 years, who have received a total knee arthroplasty, after finish the rehabilitation treatment. We compared this group with a control group of 16 subjects. We used a CYBEX NORM II isokinetic dynamometer. The test was performed in concentric regimen, assessing the Peak Torque, the Set Total Work, the angle of the Peak Torque and the ratio flexion/extension of the Peak Torque, with angular speeds of 120°/s. and 180°/s. Results. We found statistically significant differences (p 0,05) for the rest of the angles of Peak Torque and neither for the ratios flexion/extension of the Peak Torque. Conclusions. The isokinetic evaluation shows that these patients present a loss of strength for the flexion and also for the extension. The isokinetic test is an useful complementary method for the assessment of these patients; even it can be useful for an individual adaptation of an established protocol of rehabilitation, according to the different needs of each patient in each stage of the treatment
Asunto(s)
Buscar en Google
Colección: 06-national / ES Base de datos: IBECS Asunto principal: Artroplastia de Reemplazo de Rodilla / Recuperación de la Función Tipo de estudio: Guideline / Observational_studies Límite: Aged / Female / Humans / Male Idioma: Es Revista: Rehabilitación (Madr., Ed. impr.) Año: 2005 Tipo del documento: Article
Buscar en Google
Colección: 06-national / ES Base de datos: IBECS Asunto principal: Artroplastia de Reemplazo de Rodilla / Recuperación de la Función Tipo de estudio: Guideline / Observational_studies Límite: Aged / Female / Humans / Male Idioma: Es Revista: Rehabilitación (Madr., Ed. impr.) Año: 2005 Tipo del documento: Article