Estudio densitométrico del cristalino y su relación con el sistema LOCS III / Densitometric study of the crystalline lens and its relationship with the LOCS III system
Rev. cuba. oftalmol
; 26(2): 191-197, mayo-ago. 2013. tab
Article
en Es
| CUMED
| ID: cum-60235
Biblioteca responsable:
CU1.1
Ubicación: CU1.1
RESUMEN
Objetivo: determinar la dureza nuclear del cristalino clasificada por el Lens Opacities Classification System (LOCS III) y su relación con la densitometría del cristalino. Métodos: se realizó un estudio descriptivo, longitudinal y prospectivo en el Centro de Microcirugía Ocular del Instituto Cubano de Oftalmología Ramón Pando Ferrer, desde enero de 2011 hasta diciembre de 2011, en 290 pacientes diagnosticados con catarata y operados con la técnica de facoemulsificación por pre chop, más implante de lente intraocular. Resultados: los núcleos cristalineanos (N) clasificados del N1 al N6 aumentaron la densitometría del cristalino hasta un valor de 46,5 por ciento, con tiempo efectivo de facoemulsificación de 0,54 min relacionado a la dureza nuclear, al igual que las clasificadas de P2 a P5 donde la densitometría fue hasta 66,1 por ciento con valores de tiempo efectivo de facoemulsificación de 0,46 min. La edad media fue de 63,8 años de edad, se planificó una refracción esperada para -0,16 D, el equivalente esférico posoperatorio fue de 0,50 D y el astigmatismo medio inducido de -0,56 D. La mejor agudeza visual sin corrección mejoró a 0,81 en el posoperatorio y la corregida final fue de 0,96. Conclusiones: el estudio densitométrico del cristalino, como valor objetivo de su dureza, le permite al cirujano trazarse una estrategia quirúrgica adecuada en cada paciente para lograr una verdadera cirugía refractiva personalizada del cristalino y resultados visuales óptimos(AU)
ABSTRACT
Objective: To determine the nuclear hardness of the crystalline lens according to the Lens Opacities Classification System (LOCS III) and its relationship with the crystalline lens densitometry. Methods: A prospective, cross-sectional and descriptive study was conducted in 290 patients diagnosed with cataract and operated on by the prechop phacoemulsification technique plus intraocular lens implantation, at Ramon Pando Ferrer Cuban Institute of Ophthalmology from January to December, 2011. Results: The crystalline lens nuclei classified as N1 to N6 increased the lens crystalline densitometry up to 46.5 percent, with effective phacoemulsification time of 0.54min with respect to the .nucleus hardness; the densitometry value in the nuclei classified P2 to P5 rose to 66.1 percent where the effective phacoemulsification time was 0.46. The average patients' age was 63.8 years, the expected refraction was planned to be -0.16D, the postoperative spherical equivalent was 0.50 D and the mean induced astigmatism reached -0.56 D. The best uncorrected visual acuity improved by 0.81 in the postoperative period and the final corrected acuity was 0.96. Conclusions: The densitometric study of the crystalline lens, as concrete value of hardness, allows the surgeon to draw an adequate surgical strategy for each patient in order to make a real customized refractive surgery of the crystalline lens and to obtain the optimal visual results(AU)
Palabras clave
Texto completo:
1
Colección:
06-national
/
CU
Base de datos:
CUMED
Asunto principal:
Extracción de Catarata
/
Facoemulsificación
/
Densitometría
/
Cristalino
Tipo de estudio:
Observational_studies
Límite:
Female
/
Humans
/
Male
Idioma:
Es
Revista:
Rev. cuba. oftalmol
Año:
2013
Tipo del documento:
Article