Your browser doesn't support javascript.
loading
Osteossíntese de rádio e ulna em Gavião Caboclo (Buteogallus meridionalis) / Radius and ulna osteosynthesis in a Savanna Hawk (Buteogallus meridionalis)
Dal-Bó, Ísis S; Ferraz, Vanessa C. M; Cunha, Olicies da; Ferrigno, Cássio R. A.
Afiliación
  • Dal-Bó, Ísis S; Universidade de São Paulo. Faculdade de Medicina Veterinária e Zootecnia. Departamento de Cirurgia. São Paulo. BR
  • Ferraz, Vanessa C. M; s.af
  • Cunha, Olicies da; Universidade Federal do Paraná. Faculdade de Medicina Veterinária. Departamento de Ciências Veterinárias. Palotina. BR
  • Ferrigno, Cássio R. A; Universidade de São Paulo. Faculdade de Medicina Veterinária e Zootecnia. Departamento de Cirurgia. São Paulo. BR
Pesqui. vet. bras ; Pesqui. vet. bras;38(2): 335-339, fev. 2018. ilus
Article en Pt | LILACS, VETINDEX | ID: biblio-895567
Biblioteca responsable: BR68.1
RESUMO
Foi atendido um Gavião Caboclo (Buteogallus meridionalis), de vida livre e histórico desconhecido. O paciente apresentava impotência funcional da asa direita e solução de continuidade de aspecto recente envolvendo a região de rádio e ulna direitos caracterizando fratura aberta grau II. Os achados radiológicos foram fratura completa cominutiva de diáfise média de ulna e fratura completa tranversa de diáfise média de rádio. A estabilização da fratura de rádio foi realizada com miniplaca de 1,5mm de 6 orifícios, com 2 parafusos proximais e 2 parafusos distais e, osteossíntese de ulna com placa bloqueada de 2,0mm de 12 orifícios, com 3 parafusos proximais e 2 parafusos distais. Aos 180 dias de pós-operatório, os implantes ortopédicos foram removidos e o paciente recebeu alta. Conclui-se que o emprego de placa bloqueada para tratamento de fraturas abertas em ulna de Gavião Caboclo, pode propiciar adequada consolidação e retorno à função do membro sendo capaz de voar.(AU)
ABSTRACT
A wild Savanna Hawk (Buteogallus meridionalis) of unknown history, was seen at the veterinary hospital. The patient presented with a dropped right wing and soft tissue damage that appeared to be a recent wound involving the right radius and ulna region, characterizing an open fracture grade II. The radiological findings were a comminuted complete fracture of the ulnar diaphysis and complete transverse fracture of the radial diaphysis. Stabilization of the radius fracture was performed with a 1.5mm miniplate with 6 holes, with 2 proximal screws and 2 distal screws, and ulna osteosynthesis with a 2.0mm locking plate with 12 holes, with 3 proximal screws and 2 distal screws. At 180 postoperative days, the implants were removed and the patient was discharged. The use of locking plate for the treatment of open fractures in ulna of Savanna Hawks may provide adequate healing and return to limb function being able to fly.(AU)
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: LILACS / VETINDEX Asunto principal: Fracturas del Radio / Fracturas del Cúbito / Placas Óseas / Halcones / Fijación Interna de Fracturas Límite: Animals Idioma: Pt Revista: Pesqui. vet. bras Asunto de la revista: MEDICINA VETERINARIA Año: 2018 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: LILACS / VETINDEX Asunto principal: Fracturas del Radio / Fracturas del Cúbito / Placas Óseas / Halcones / Fijación Interna de Fracturas Límite: Animals Idioma: Pt Revista: Pesqui. vet. bras Asunto de la revista: MEDICINA VETERINARIA Año: 2018 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Brasil