Hallazgos ecocardiográficos en el embarazo y posparto tardío en mujeres mexicanas sanas / Echocardiographical findings in pregnancy and late postpartum of healthy mexicans women´s
Ginecol. obstet. Méx
; Ginecol. obstet. Méx;88(5): 296-305, ene. 2020. tab, graf
Article
en Es
|
LILACS-Express
| LILACS
| ID: biblio-1346191
Biblioteca responsable:
MX1.1
RESUMEN
Resumen OBJETIVO:
Evaluar y comparar la adaptación cardiovascular materna mediante variables antropométricas y parámetros hemodinámicos con ecocardiografía Doppler en mujeres mexicanas sanas, con embarazo único. MATERIALES YMÉTODOS:
Estudio prospectivo, observacional, longitudinal, efectuado de enero de 2014 a enero de 2017 en mujeres que cursaban el segundo y tercer trimestres del embarazo. A los 6 meses posparto se practicaron ecosonogramas obstétricos y registros ecocardiográficos Doppler a todas las pacientes del estudio. Cada paciente fue su propio control. Se aplicó el análisis estadístico con SPSS Windows v17, ANOVA para comparar los 3 grupos, con valor significativo de p < 0.05, y correlación no paramétrica de Pearson.RESULTADOS:
Se estudiaron 30 embarazadas con edad promedio de 22.5 ± 3.1 años. Las semanas de embarazo se corroboraron con ultrasonido obstétrico. En el ecocardiograma transtorácico se observaron cambios significativos entre el segundo trimestre y los 6 meses posparto el ventrículo izquierdo en diástole (cm), 4.5 ± 2.5 vs 4.2 ± 3.3, p < 0.01. El volumen diastólico final del ventrículo izquierdo (mL) fue de 93 ± 14.8 vs 78 ± 17.8 (p < 0.05), el volumen latido (mL) 99.5 ± 15.7 vs 86 ± 11.8 (p < 0.01). Las resistencias vasculares sistémicas (dinas/seg/cm-5), 870 ± 108 vs 1262 ± 176 (p < 0.01). Del segundo al tercer trimestres y posnatal hubo incrementos en la aurícula izquierda (cm) 3.1 ± 4.6, 3.3 ± 4.4, 2.9 ± 4.3 (p < 0.001), gasto cardiaco (L/m) 6.8 ± 0.4, 7.0 ± 0.4, 4.7 ± 0.4 (p < 0.001).CONCLUSIONES:
El embarazo es un estado de sobrecarga transitoria de volumen con importantes efectos orgánicos y funcionales, sobre todo en el segundo trimestre.ABSTRACT
Abstract OBJECTIVE:
The aim of this prospective, observational and longitudinal study, was to evaluate and to compare the maternal adaptation through changes on anthropometric and Doppler echocardiographic parameters in Mexican normal pregnancy with single product. MATERIALS ANDMETHODS:
Prospective, observational, longitudinal study, from January 2014 to January 2017. Obstetric ecosonograms and echocardiographic Doppler studies were performed on 2nd and 3rd trimester and six months postpartum. Each patient was her own control. The data were analyzed using SPSS Windows 17, ANOVA for compared the 3 groups with P value < 0.05 was considered significant, as well as a non-parametric correlation of Pearson.RESULTS:
There were thirty pregnant with a mean age 22.5 ± 3.1 years-old, between 2nd and 3rd trimester, with obstetrics ultrasound were corroborated gestational age. With transthoracic echocardiography, we found significant changes between 2nd trimester and 6 month post-partum, among the main, the left ventricle (LV) in diastole (cm), 4.5 ± 2.5 versus 4.2 ± 2.3 (p < 0.01), end diastolic left ventricle volume (mL) 93 ± 14.8, vs 78 ± 17.8 (p < 0.05). Stroke volume (mL) 99.5 ± 15.7 vs 86 ± 11.8 (p < 0.01). Systemic vascular resistance (dyne/sec/cm5 ) 870 ± 108 vs 1,262 ± 176 (p < 0.001). From, 2nd and 3rd trimester and postpartum, left atrial diameter (cm), 3.1 ± 4.4, 3.3 ± 4.4, 2.9 ± 4.3 (p < 0.001). Cardiac output (L/m), 6.8 ± 0.4, 7.0 ± 0.4, 4.7 ± 0.4 (p < 0.001).CONCLUSION:
Pregnancy is a transitory overload condition with important organic and functional effects mainly in the second trimester.
Texto completo:
1
Colección:
01-internacional
Base de datos:
LILACS
País/Región como asunto:
Mexico
Idioma:
Es
Revista:
Ginecol. obstet. Méx
Asunto de la revista:
GINECOLOGIA
/
OBSTETRICIA
Año:
2020
Tipo del documento:
Article
País de afiliación:
México
Pais de publicación:
México