1.
Rev Lat Am Enfermagem ; 32: e4143, 2024.
Artigo em Inglês, Espanhol, Português | MEDLINE | ID: mdl-38655937

RESUMO

OBJECTIVES: this study aimed at estimating and comparing the reliability of temperature measurements obtained using a peripheral infrared temporal thermometer, a central cutaneous thermometer ("Zero-Heat-Flux Cutaneous thermometer") and an esophageal or nasopharyngeal thermometer among elective surgical patients in the intraoperative period. METHOD: a longitudinal study with repeated measures carried out by convenience sampling of 99 patients, aged at least 18 years old, undergoing elective abdominal cancer surgeries, with anesthesia lasting at least one hour, with each patient having their temperature measured by all three methods. RESULTS: the intraclass correlation coefficient showed a low correlation between the measurements using the peripheral temporal thermometer and the central cutaneous (0.0324) and esophageal/nasopharyngeal (-0.138) thermometers. There was a high correlation (0.744) between the central thermometers evaluated. CONCLUSION: the data from the current study do not recommend using infrared temporal thermometers as a strategy for measuring the body temperature of patients undergoing anesthetic-surgical procedures. Central cutaneous thermometers and esophageal/nasopharyngeal thermometers are equivalent for detecting intraoperative hypothermia.


Assuntos
Temperatura Corporal , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Longitudinais , Idoso , Termômetros/normas , Adulto , Período Intraoperatório , Cuidados Intraoperatórios/métodos , Cuidados Intraoperatórios/instrumentação
2.
Rio de Janeiro; rBLH; 2 rev; set. 2021. [8] p. ilus.(Normas técnicas BLH-IFF/NT, 1, 44). (BLH-IFF/NT 44.21).
Monografia em Espanhol, Português | LILACS, BVSAM | ID: biblio-1436547

RESUMO

Esta Norma Técnica tem por objetivo estabelecer as orientações necessárias para aferição e leitura dos termômetros utilizados no controle de temperatura nos Bancos de Leite Humano e Postos de Coleta de Leite Humano, visando a garantia da qualidade nestes serviços e sua certificação.


Esta Norma Técnica tiene como objetivo establecer las orientaciones necesarias para la medición y la lectura de los termómetros utilizados en el control de la temperatura en los Bancos de Leche Humana y en los Centros de Recolección de Leche Humana, con el fin de garantizar la calidad de estos servicios y su certificación.


Assuntos
Controle de Qualidade , Temperatura , Termômetros/normas , Calibragem/normas , Bancos de Leite Humano/normas , Leite Humano
3.
Rio de Janeiro; rBLH; 2 rev; set. 2021. [8] p. ilus.(Normas técnicas BLH-IFF/NT, 1, 38). (BLH-IFF/NT 38.21).
Monografia em Espanhol, Português | LILACS, BVSAM | ID: biblio-1436526

RESUMO

Esta Norma Técnica tem por objetivo estabelecer as orientações necessárias para o controle de temperatura dos freezers em Bancos de Leite humano e Postos de Coleta de Leite Humano, visando a garantia da qualidade em Bancos de Leite Humano e sua certificação.


Esta Norma Técnica tiene como objetivo establecer las directrices necesarias para el control de la temperatura de los congeladores en los Bancos de Leche Humana y en los Centros de Recolección de Leche Humana con el fin de asegurar la calidad en los Bancos de Leche Humana y su certificación.


Assuntos
Temperatura , Termômetros/normas , Bancos de Leite Humano/normas , Congelamento , Leite Humano
4.
Lima; Perú. Ministerio de Salud. Instituto Nacional de Salud; ago. 2018.
Não convencional em Espanhol | BRISA/RedTESA | ID: biblio-969870

RESUMO

INTRODUCCIÓN: La fiebre en los niños es una preocupación común para los padres y una de las causas más comunes de visita a los hospitales. Aunque la incidencia de infecciones graves ha disminuido después de la introducción de vacunas conjugadas, la fiebre sigue siendo una de las principales causas de la investigación de laboratorio y los ingresos hospitalarios. Debido a esto existen distintas tecnologías de termómetros para cuantificar la fiebre. Los termómetros electrónicos o infrarrojos son utilizados en muchos hospitales, constan de una sonda infrarroja, un circuito electrónico, un microprocesador y una pantalla LCD o LED. Se postula el uso de un cobertor desechable para el termómetro electrónico ótico ya que podría prevenir la frencuencia de infecciones cruzadas. TECNOLOGÍA: El cobertor desechable para termómetro electrónico está hecho de diferentes materialies (generalmente polipropileno) y es diseñado específicamente de acuerdo a las dimensiones del termómetro de elección. De esta forma, calza herméticamente en la punta de la sonda del termómetro. Esta cobertura es utilizada como una barrera sanitaria entre el termómetro infrarrojo y el canal auditivo para prevenir que las secreciones óticas u otras partículas puedan ser transferidas entre las personas a las cuales se les mide la temperatura. OBJETIVO: Evaluar la eficacia y seguridad, así como documentos relacionados a la decisión de cobertura de los cobertores desechables para sonda de termómetro clínico electrónico. METODOLOGÍA: Se realizó una búsqueda en las principales bases bibliográficas: MEDLINE, LILACS, COCHRANE, así como en buscadores genéricos de Internet incluyendo Google Scholar y TRIPDABASE. Adicionalmente, se hizo una búsqueda dentro de la información generada por las principales instituciones internacionales de desinfección y limpiza de dispositivos para la medición de temperatura y agencias de tecnologías sanitarias que realizan revisiones sistemáticas(RS), evaluación de tecnologías sanitarias (ETS) y guías de práctica clínica (GPC). RESULTADOS: No se encontraron ECAS, ETS ni evaluaciones de la región. Se identificó sólo una GPC que mencionaba a la tecnología. CONCLUSIONES: La evidencia comparativa con respecto al uso de los cobertores desechables para sonda de termómetro clínico electrónico es escasa. Si bien no se identificó estudios comparativos del uso de esta tecnología, diversas marcas han sido aprobadas y son utilizadas rutinariamente con termómetros óticos infrarrojos. En el perú la aprobación por DIGEMID sólo menciona al termómetro más no al cobertor. Sólo una GPC recabada, menciona a la tenología dentro de las instrucciones para el uso de termómetro timpánico en la toma de temperatura. no se ha encontrado otros procedimientos de limpieza o desinfección del termómetro ótico.


Assuntos
Humanos , Termômetros/normas , Sonda de Prospecção , Avaliação da Tecnologia Biomédica , Análise Custo-Eficiência
5.
Rev. AMRIGS ; 57(4): 299-303, out.-dez. 2013. tab, graf
Artigo em Português | LILACS | ID: biblio-847528

RESUMO

Introdução: Os termômetros feitos com mercúrio, ainda utilizados, têm alto risco tóxico para o indivíduo e o meio ambiente. Busca-se o termômetro ideal que deverá substituir os termômetros de mercúrio. O objetivo deste estudo é avaliar a concordância entre os termômetros eletrônicos axilar e instantâneos (auricular e cutâneo frontal) com os termômetros eletrônico retal e axilar de mercúrio na aferição da temperatura corporal de crianças. Métodos: Estudo transversal realizado no Serviço de Pediatria do Hospital de Clínicas de Porto Alegre, em amostra de conveniência de crianças cujas temperaturas foram medidas sequencialmente com termômetros eletrônicos e axilar de mercúrio. Para as comparações, foi utilizada a análise de Bland e Altman, avaliando médias de diferenças de temperaturas (MDT) e intervalos de confiança de 95% (IC95%) de até 0,2°C. Resultados: Foram avaliadas 20 crianças febris e 43 eutérmicas, com idades entre um mês e dois anos, totalizando 633 aferições da temperatura corporal. Houve concordância parcial entre os termômetros axilar de mercúrio aos três minutos e axilar eletrônico, com MDT de -0,02°C e IC95% de -0,73°C a 0,68°C, e entre os termômetros eletrônicos retal e axilar de mercúrio aos três minutos, com MDT de -0,12°C e IC95% de -1,08°C a 0,84°C. Conclusões: Os termômetros eletrônicos instantâneos cutâneo frontal e auricular não apresentaram boa concordância, enquanto o termômetro eletrônico axilar apresentou a melhor concordância com o termômetro retal, sendo aquele considerado o melhor substituto do termômetro axilar de mercúrio para a aferição da temperatura corporal de crianças (AU)


Introduction: Mercury thermometers, though still used, have a high toxic risk for humans and the environment. The ideal thermometer is sought to replace mercury thermometers. The aim of this study was to assess the correlation of axillary and instantaneous electronic thermometers (ear and forehead) with rectal and axillary mercury thermometers in measuring body temperature of children. Methods: Cross-sectional study conducted in the Department of Pediatrics, Hospital de Clinicas de Porto Alegre, in a convenience sample of children whose temperatures were measured sequentially with electronic and axillary mercury thermometers. For comparisons, Bland and Altman's analysis was used to evaluate differences in mean temperatures (MDT) and confidence intervals of 95% (CI 95%) of up to 0.2 °C. Results: Twenty feverish children and 43 euthermic children, aged between one month and two years, were evaluated, with a total of 633 measurements of body temperature. There was partial concordance between the axillary mercury and electronic thermometer at three minutes, with MDT -0.02 °C and CI 95% of -0.73 ° C to 0.68 °C, and between electronic rectal and axillary mercury thermometers at three minutes, with MDT -0.12 °C and 95% CI of -1.08 ° C to 0.84 °C. Conclusions: The instantaneous electronic ear and forehead thermometers did not show good agreement, while the axillary electronic thermometer showed the best agreement with the rectal thermometer, being considered the best substitute for axillary mercury thermometer to measure body temperature of children (AU)


Assuntos
Humanos , Lactente , Termômetros/normas , Temperatura Corporal , Estudos Transversais
6.
Int Braz J Urol ; 39(4): 572-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24054386

RESUMO

PURPOSE: To evaluate infrared thermometer (IRT) accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling. MATERIALS AND METHODS: 20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush) and 10 without renal cooling (Group 2 - Warm Ischemia). Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT): immediate after clamping (T0), after 2 (T2), 5 (T5) and 10 minutes (T10). Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant. RESULTS: In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C) while deep DT temperature decrease was 15.8 ± 1.5 °C (15-18 °C). For the IRT, mean temperature decrease was 9.1 ± 3.8 °C (3-14°C). There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C) and mean deep temperature decrease was 0.5 ± 1.0 °C (0-3 °C). For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C). No statistically significant difference between thermometers was found at any time point. CONCLUSIONS: IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model.


Assuntos
Temperatura Corporal , Raios Infravermelhos , Rim/cirurgia , Termômetros/normas , Animais , Isquemia Fria , Constrição , Desenho de Equipamento , Masculino , Ilustração Médica , Valores de Referência , Reprodutibilidade dos Testes , Propriedades de Superfície , Sus scrofa , Fatores de Tempo , Isquemia Quente
7.
Int. braz. j. urol ; 39(4): 572-578, Jul-Aug/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-687300

RESUMO

Purpose To evaluate infrared thermometer (IRT) accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling. Materials and Methods 20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush) and 10 without renal cooling (Group 2 - Warm Ischemia). Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT): immediate after clamping (T0), after 2 (T2), 5 (T5) and 10 minutes (T10). Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant. Results In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C) while deep DT temperature decrease was 15.8 ± 1.5°C (15-18°C). For the IRT, mean temperature decrease was 9.1 ± 3.8°C (3-14°C). There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C) and mean deep temperature decrease was 0.5 ± 1.0°C (0-3°C). For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C). No statistically significant difference between thermometers was found at any time point. conclusions IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model. IRT = Infrared thermometer DT = Digital contact thermometer D:S = Distance-to-spot ratio .


Assuntos
Animais , Masculino , Temperatura Corporal , Raios Infravermelhos , Rim/cirurgia , Termômetros/normas , Isquemia Fria , Constrição , Desenho de Equipamento , Ilustração Médica , Valores de Referência , Reprodutibilidade dos Testes , Propriedades de Superfície , Sus scrofa , Fatores de Tempo , Isquemia Quente
8.
Can Vet J ; 52(4): 403-6, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21731094

RESUMO

Although the rectal mucosa remains the traditional site for measuring body temperature in dogs, an increasing number of clinicians have been using auricular temperature to estimate core body temperature. In this study, 88 mature healthy dogs had body temperatures measured with auricular and rectal thermometers. The mean temperature and confidence intervals were similar for each method, but Bland-Altman plots showed high biases and limits of agreement unacceptable for clinical purposes. The results indicate that auricular and rectal temperatures should not be interpreted interchangeably.


Assuntos
Temperatura Corporal/fisiologia , Doenças do Cão/metabolismo , Meato Acústico Externo/metabolismo , Reto/metabolismo , Termômetros/veterinária , Animais , Cães , Feminino , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Termômetros/normas
9.
Rev. Inst. Méd. Sucre ; 68(122): 86-91, 2003.
Artigo em Espanhol | LILACS | ID: lil-349471

RESUMO

Los hombres queremos conocer la naturaleza para dominarla, obtener de ella el máximo beneficio, y satisfacer nuestras necesidades, la inventiva humana ha logrado dar saltos importantes determinando el progreso tecnológico. el bienstar humano ha sido la mayor preocupacióm y hubieron numerosos e insignes hombres de cencia, que dedicaron su vida y conocimientos en busca de devolver la salud, he aquí un ejemplo de cómo estos científicos lograron crear un instrumento valioso, como es el termómetro y su aplicación en la medicina, para bien de la humanidad. El presente trabajo de investigación comprende dos momnetos, por una parte el desarrollo evolutivo del termómetro en general que comprende el contexto histórico y por otra parte el marco teórico que trata del origen y evolución en la aplicaicón de este instrumento en medicina, como método diagnóstico de las enfermedades, que sin duda alguna , constituye un hito en la historia de la medicina y un gran aporte ala ciencia. Este trabajo sin emabrgo no pretende descubrir los descubierto, pero intenta ubicar los momentos históricos por los cuales tuvo que transitar la invención de este instrumento de medición diaria de la temperatura como método científico, de ahí que apoyado en la documentación histoórica, se utilizo el método investigativo, así como el explicativo e ilustrativo. apoyado en la lógica de la investigación y motivado por la significación que constituye el termómetro en la práctica médica, inicio este trabajo titulado: "El termómetro clínico en el registro de la temperatura: un hito en la historia de la medicina".Problema: necesidad de conocer el momento histórico de la invención y aplicación de un instrumento que permitió el diagnóstico clínico y registro de la temperatura corporal en el proceso salud enfermedad. Objeto: Signos y síntomas del proceso salud enfermedad. Campo de acción: Diagnóstico dínico y registro de la temperatura corporal. Objetivo. Establecer el hecho histórico de la invención y aplicación del termómetro en el diagnóstico clínico y e registro de la temperatura corporal.


Assuntos
Temperatura Corporal , Bolívia , Diagnóstico Clínico , Febre , História da Medicina , Termômetros/classificação , Termômetros/história , Termômetros/normas , Termômetros
10.
Rev. Hosp. Matern. Infant. Ramon Sarda ; 19(2): 78-80, 2000. graf
Artigo em Espanhol | LILACS | ID: lil-278651

RESUMO

Objetivos: Cuantificar el número de mujeres que conoce la utilidad del termómetro. Establecer el porcentaje de mujeres que sabe los valores normales de temperatura de un recién nacido. Relacionar qué número de mujeres de las que utiliza correctamente el termómetro sabe leerlo. Conocer el número de mujeres que posee el termómetro. Diseño: Prospectivo, observacional, descriptivo, con una secuencia temporal de corte transversal. Métodos: Para la medición de las variables se utilizó una encuesta además de la observación de la técnica. Resultados: fueron encuestadas 645 mujeres. El 94,7 por ciento reconoce para qué sirve el termómetro; el 67 por ciento lo utiliza en forma correcta; el 57,5 por ciento sabe leerlo; 85,9 por ciento de las que lo utilizan correctamente, sabe leerlo; 19,5 por ciento del total conoce los valores normales de temperatura axilar del recién nacido y por último 62,9 por ciento posee termómetro.


Assuntos
Humanos , Gravidez , Recém-Nascido , Temperatura Corporal/fisiologia , Recém-Nascido , Coleta de Dados/estatística & dados numéricos , Coleta de Dados/métodos , Valores de Referência , Termômetros/estatística & dados numéricos , Termômetros/normas , Termômetros , Análise Multivariada , Educação de Pacientes como Assunto
11.
Rev. Hosp. Matern. Infant. Ramon Sarda ; 19(2): 78-80, 2000. graf
Artigo em Espanhol | BINACIS | ID: bin-11125

RESUMO

Objetivos: Cuantificar el número de mujeres que conoce la utilidad del termómetro. Establecer el porcentaje de mujeres que sabe los valores normales de temperatura de un recién nacido. Relacionar qué número de mujeres de las que utiliza correctamente el termómetro sabe leerlo. Conocer el número de mujeres que posee el termómetro. Diseño: Prospectivo, observacional, descriptivo, con una secuencia temporal de corte transversal. Métodos: Para la medición de las variables se utilizó una encuesta además de la observación de la técnica. Resultados: fueron encuestadas 645 mujeres. El 94,7 por ciento reconoce para qué sirve el termómetro; el 67 por ciento lo utiliza en forma correcta; el 57,5 por ciento sabe leerlo; 85,9 por ciento de las que lo utilizan correctamente, sabe leerlo; 19,5 por ciento del total conoce los valores normales de temperatura axilar del recién nacido y por último 62,9 por ciento posee termómetro. (AU)


Assuntos
Humanos , Gravidez , Recém-Nascido , Termômetros/estatística & dados numéricos , Termômetros/estatística & dados numéricos , Termômetros/normas , Temperatura Corporal/fisiologia , Recém-Nascido , Valores de Referência , Coleta de Dados/estatística & dados numéricos , Coleta de Dados/métodos , Educação de Pacientes como Assunto , Análise Multivariada
14.
Rev Argent Microbiol ; 26(3): 146-9, 1994.
Artigo em Espanhol | MEDLINE | ID: mdl-7838979

RESUMO

534 autoclaves from Rosario dentist offices were controlled by a method developed in our laboratory, that consists in: a) a procedures instruction; b) a survey ; c) a colorimetric control; d) a biological control. By this method it is possible to detect the mistake in the autoclave function by only one step. The results showed that 86.90% of the autoclaves lacked thermometers, 76.60% lacked manual thermostats, 83.33% were automatic and 58.80% did not sterilize. It can be concluded the necessity of a periodic control by this method, the importance of a commercial quality control of the furnaces and the urgency of continuous education over biosafety concepts.


Assuntos
Equipamentos Odontológicos/normas , Controle de Infecções/normas , Esterilização/métodos , Argentina , Bacillus subtilis/fisiologia , Colorimetria , Coleta de Dados , Equipamentos Odontológicos/estatística & dados numéricos , Desenho de Equipamento , Falha de Equipamento/estatística & dados numéricos , Controle de Qualidade , Esporos Bacterianos , Esterilização/instrumentação , Esterilização/normas , Termômetros/normas
15.
J Pediatr ; 122(5 Pt 1): 769-73, 1993 May.
Artigo em Inglês | MEDLINE | ID: mdl-8496759

RESUMO

OBJECTIVE: To compare temperatures obtained with glass-mercury axillary and aural infrared thermometers with temperatures obtained with glass-mercury rectal thermometers. DESIGN: Blind comparison with criterion standard. SETTING: Well-baby nursery at a private teaching hospital. PATIENTS: Convenience sampling of 200 term newborn infants. INTERVENTION: Temperatures were measured simultaneously with glass-mercury rectal and axillary thermometers for a 3-minute period by one investigator. In a blinded fashion, a second investigator obtained three aural temperatures by using two tympanic membrane thermometers. One tympanic membrane reported infants' rectal-equivalent temperatures, and a second reported oral equivalent temperatures. RESULTS: Temperatures obtained with glass-mercury rectal and axillary thermometers for the population were similar (37 degrees +/- 0.4 degree C vs 36.8 degrees +/- 0.3 degrees C, respectively), but 25% of measurements at these two sites differed by > 0.3 degree C. Oral-equivalent tympanic membrane temperatures were more accurate than rectal-equivalent temperatures in predicting an infant's glass-mercury axillary and rectal temperatures (75% of oral-equivalent temperatures vs fewer than 50% of rectal-equivalent temperatures were within 0.3 degree C of either glass-mercury rectal or axillary measurements). CONCLUSIONS: Temperatures obtained with glass-mercury axillary and rectal thermometers are similar in most cases. However, temperatures obtained with tympanic membrane thermometers either in the rectal-equivalent mode or in the oral-equivalent mode did not accurately reflect an infant's rectal or axillary temperature. We believe that tympanic membrane temperatures should not be substituted for rectal or axillary temperatures in assessments of newborn infants.


Assuntos
Temperatura Corporal , Recém-Nascido/fisiologia , Termômetros , Axila , Orelha , Feminino , Humanos , Masculino , Reto , Reprodutibilidade dos Testes , Termômetros/normas