Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Cienc. tecnol. salud ; 9(1): 82-97, 2022. il 27
Artigo em Inglês | LILACS, DIGIUSAC, LIGCSA | ID: biblio-1390741

RESUMO

White cement-based mortars in urban areas are usually discolored and altered their esthetic properties due to air pollutants. The addition of nanoparticles in these mortars can provide photocatalytic properties that can decompose pollution agents. Likewise, other hydrophobic agents have been individually studied to improve outdoor building constructions. Therefore, this study presented the photocatalytic and hydrophobic effect of adding nano-TiO2and silicone hydrophobic powder (DOWSILTM) in a white cement matrix. The nano-TiO2 were characterized by X-Ray Diffraction (XRD); afterwards, the mortar was mixed with additions of nano-TiO2 (0.0, 0.5, 1.0, 3.0%) and DOWSILTM (0.0, 0.5%). The mortar's photocatalytic performance was evaluated using a modification of the standard Italian test Ente Nazionale Italiano di Unificazione 11259:2016 based on Rhodamine B (RhB) degradation on the sample exposed to UV irradiation. Therefore, mortar samples were subjected to UV irradiation to degrade the organic dye rhodamine B, monitoring their color variation using a C I E L* a* b* spectrophotometer. Moreover, the water permeability and the contact angle were evaluated. This research demonstrates that the white cement-based mortar samples added with nano-TiO2/DOWSILTM possess photocatalytic activity. The samples with the addition of 1.0%/0.5% and 3.0%/0.5% nano-TiO2/DOWSILTM showed a higher RhB degradation for R4 and R26. Therefore, these two materials can be employed in these proportions to improve the quality of the white cement-based mortars in urban constructions.


Los morteros a base de cemento blanco generalmente se decoloran y alteran sus propiedades estéticas debido a los contaminantes del aire en las áreas urbanas. Nanopartículas añadidas a estos morteros pueden proporcionar propiedades fotocatalíticas que descomponen estos contaminantes. Asimismo, otros agentes hidrofóbicos se han estu-diado individualmente para mejorar las construcciones a la intemperie. Por lo tanto, se presenta el efecto fotocatalítico e hidrofóbico al incorporar nano-TiO2 y silicona hidrofóbica de polisiloxano (DOWSILTM) en una matriz de cemento blanco. El nano-TiO2 se caracterizó por medio de Difracción de Rayos X (DRX); luego, el mortero se mezcló con adiciones de nano-TiO2 (0.0, 0.5, 1.0, 3.0%) y DOWSILTM (0.0, 0.5%). Los morteros se sometieron a irradiación UV, para degradar el colorante orgánico rodamina B, monitoreando su variación de color usando un espectrofotómetro C I E L* a* b*. La eficiencia fotocatalítica del mortero se evaluó utilizando una modificación de la norma italiana Ente Nazionale Italiano di Unificazione 11259:2016 basada en la degradación de la rodamina B (RhB) en el mortero expuesto a la radiación UV. Además, se evaluó la permeabilidad al agua y el ángulo de contacto. Esta investigación demostró que el mortero de cemento con nano-TiO2/ DOWSILTM posee actividad fotocatalítica. Las muestras con 1.0%/0.5% y 3.0%/0.5% nano-TiO2/DOWSILTM mostraron una mayor eficiencia de degradación de RhB para R4 y R26. Por lo tanto, estos materiales tienen potencial para mejorar la calidad de los morteros en construcciones urbanas.


Assuntos
Poluentes Atmosféricos , Absorção , Nanopartículas , Permeabilidade , Silicones/análise , Titânio/análise , Materiais de Construção/análise
2.
R. Educ. contin. Med. Vet. Zoot. ; 19(1): e38097, abr. 2021. graf, tab
Artigo em Português | VETINDEX | ID: vti-30703

RESUMO

O presente estudo avaliou a efetividade de simulador de sutura de silicone frente ao modelo usual em feltro e bastidor no desenvolvimento da habilidade em síntese cirúrgica. Vinte e seis alunos de Medicina Veterinária, sem vivência cirúrgica, foram distribuídos em dois grupos: o primeiro utilizou modelo de simulador em silicone e o segundo o simulador em bastidor e feltro. Em três encontros foram abordados conceitos sobre síntese, tipos de sutura e treinamento prático. Para avaliar sua experiência e percepções, os alunos responderam a um questionário e foram avaliados pelos professores na confecção dos padrões de sutura. Na avaliação do questionário, o simulador em silicone foi superior em sete das 10 questões. Na avaliação dos docentes, não houve diferença entre os grupos. Concluímos que ambos os modelos foram efetivos no desenvolvimento da habilidade cirúrgica, porém, a aceitabilidade dos alunos foi superior no modelo inovador.(AU)


This study compared the efficiency of a novel silicone model to a traditional low-fidelity method on the acquisition of surgical synthesis skills. Twenty-six veterinary students with no prior surgical training were randomly allocated into two groups: the first used a novel silicon model and second trained on a traditional set up. During three sessions, subjects such as synthesis, suture patterns, and suture practice were discussed. In order to assess the students experiences and perceptions, a questionary was applied. Students were also evaluated by teachers who scored their suture patterns. The questionary showed that the silicone model was superior in 7 out of 10 questions. No significant differences were detected between groups on the assessment by the teachers. This study shows that either model is effective for the development of suture skills. Nonetheless, the novel silicone model tested here has better acceptability when compared with the traditional model.(AU)


Assuntos
Técnicas de Sutura/veterinária , Silicones/administração & dosagem , Silicones/análise , Medicina Veterinária
3.
Rev. Educ. Contin. Med. Vet. Zootec. CRMV-SP (Online) ; 19(1): e38097, abr. 2021. graf, tab
Artigo em Português | VETINDEX | ID: biblio-1489072

RESUMO

O presente estudo avaliou a efetividade de simulador de sutura de silicone frente ao modelo usual em feltro e bastidor no desenvolvimento da habilidade em síntese cirúrgica. Vinte e seis alunos de Medicina Veterinária, sem vivência cirúrgica, foram distribuídos em dois grupos: o primeiro utilizou modelo de simulador em silicone e o segundo o simulador em bastidor e feltro. Em três encontros foram abordados conceitos sobre síntese, tipos de sutura e treinamento prático. Para avaliar sua experiência e percepções, os alunos responderam a um questionário e foram avaliados pelos professores na confecção dos padrões de sutura. Na avaliação do questionário, o simulador em silicone foi superior em sete das 10 questões. Na avaliação dos docentes, não houve diferença entre os grupos. Concluímos que ambos os modelos foram efetivos no desenvolvimento da habilidade cirúrgica, porém, a aceitabilidade dos alunos foi superior no modelo inovador.


This study compared the efficiency of a novel silicone model to a traditional low-fidelity method on the acquisition of surgical synthesis skills. Twenty-six veterinary students with no prior surgical training were randomly allocated into two groups: the first used a novel silicon model and second trained on a traditional set up. During three sessions, subjects such as synthesis, suture patterns, and suture practice were discussed. In order to assess the students experiences and perceptions, a questionary was applied. Students were also evaluated by teachers who scored their suture patterns. The questionary showed that the silicone model was superior in 7 out of 10 questions. No significant differences were detected between groups on the assessment by the teachers. This study shows that either model is effective for the development of suture skills. Nonetheless, the novel silicone model tested here has better acceptability when compared with the traditional model.


Assuntos
Medicina Veterinária , Silicones/administração & dosagem , Silicones/análise , Técnicas de Sutura/veterinária
4.
J Appl Microbiol ; 128(2): 387-400, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31573730

RESUMO

AIMS: To study the individual and combined contribution of catechin, protocatechuic and vanillic acids to inhibit the adhesion of uropathogenic Escherichia coli (UPEC) on the surface of silicone catheters. METHODS AND RESULTS: The adhesion of UPEC to silicone catheters during the exposure to nonlethal concentrations of phenolic compounds was measured, as well as changes in motility, presence of fimbriae, extra-cellular polymeric substances, surface charge, hydrophobicity and membrane fluidity. The phenolic combination reduced 26-51% of motility, 1 log CFU per cm2 of adhered bacteria and 20-40% the carbohydrate and protein content in the biofilm matrix. Curli fimbriae, surface charge and cell hydrophobicity were affected to a greater extent by the phenolic combination. In the mixture, vanillic acid was the most effective for reducing bacterial adhesion, extra-polymeric substance production, motility, curli fimbriae and biofilm structure. Notwithstanding, protocatechuic acid caused major changes in the bacterial cell surface properties, whereas catechin affected the cell membrane functionality. CONCLUSION: Catechin, protocatechuic and vanillic acids have different bacterial cell targets, explaining the synergistic effect of their combination against uropathogenic E. coli. SIGNIFICANCE AND IMPACT OF STUDY: This study shows the contribution of catechin, protocatechuic and vanillic acids in producing a synergistic mixture against the adhesion of uropathogenic E. coli on silicone catheters. The action of catechin, vanillic and protocatechuic acids included specific contributions of each compound against the E. coli membrane's integrity, motility, surface properties and production of extracellular polymeric substances. Therefore, the studied mixture of phenolic compounds could be used as an antibiotic alternative to reduce urinary tract infections associated with silicone catheters.


Assuntos
Antibacterianos/farmacologia , Aderência Bacteriana/efeitos dos fármacos , Biofilmes/efeitos dos fármacos , Catequina/farmacologia , Hidroxibenzoatos/farmacologia , Infecções Urinárias/microbiologia , Escherichia coli Uropatogênica/efeitos dos fármacos , Ácido Vanílico/farmacologia , Catéteres/microbiologia , Sinergismo Farmacológico , Infecções por Escherichia coli/microbiologia , Fímbrias Bacterianas/efeitos dos fármacos , Fímbrias Bacterianas/genética , Fímbrias Bacterianas/metabolismo , Humanos , Fenóis/farmacologia , Silicones/análise , Escherichia coli Uropatogênica/crescimento & desenvolvimento , Escherichia coli Uropatogênica/fisiologia
5.
Rev. bras. cir. plást ; 32(2): 291-294, 2017. ilus
Artigo em Inglês, Português | LILACS | ID: biblio-847449

RESUMO

Durante muitos anos, os implantes de silicone foram utilizados em cirurgias reconstrutivas e estéticas, principalmente em casos em que o perfil facial do paciente apresenta deficiência no terço inferior da face. Este material tem provado ser bem sucedido na maioria dos aspectos, contudo, algumas complicações já foram bem relatadas na literatura, como é o caso das reabsorções ósseas na região de mento mandibular. No presente artigo os autores apresentam dois casos clínicos de reabsorção óssea da cortical anterior do mento, associada ao implante de silicone e discutem a etiologia, as complicações e o plano de tratamento.


For many years, silicone implants were used in reconstructive and esthetic surgeries, especially in cases in which the facial profile of patients presented deficiencies in the inferior third of the face. This material proved to be successful in most aspects. However, several complications were well reported in the literature, as the case of bone reabsorption in the region of the mandibular chin. In this article, the authors present two clinical cases of bone reabsorption from the anterior cortex of the chin associated with silicone implants and discuss the etiology, complications, and treatment plan.


Assuntos
Humanos , Feminino , Criança , Pessoa de Meia-Idade , História do Século XXI , Silicones , Reabsorção Óssea , Mentoplastia , Silicones/análise , Silicones/toxicidade , Reabsorção Óssea/cirurgia , Mentoplastia/métodos
6.
Acta cir. bras. ; 31(12): 774-782, Dec. 2016. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: vti-20988

RESUMO

PURPOSE:To assess the capsules formed by silicone implants coated with polyurethane foam and with a textured surface.METHODS:Sixty-four Wistar albinus rats were divided into two groups of 32 each using polyurethane foam and textured surface. The capsules around the implants were analyzed for 30, 50, 70 and 90 days. Were analyzed the following parameters: foreign body reaction, granulation tissue, presence of myofibroblasts, neoangiogenesis, presence of synovial metaplasia, capsular thickness, total area and collagen percentage of type I and III, in capsules formed around silicone implants in both groups.RESULTS:The foreign body reaction was only present in the four polyurethane subgroups. The formation of granulation tissue and the presence of myofibroblasts were higher in the four polyurethane subgroups. Regarding to neoangiogenesis and synovial metaplasia, there was no statistical difference between the groups. Polyurethane group presented (all subgroups) a greater capsule thickness, a smaller total area and collagen percentage of type I and a higher percentage area of type III, with statistical difference.CONCLUSION:The use of polyurethane-coated implants should be stimulated by the long-term results in a more stable capsule and a lower incidence of capsular contracture, despite developing a more intense and delayed inflammatory reaction in relation to implants with textured surface.(AU)


Assuntos
Animais , Feminino , Ratos , Silicones/análise , Silicones/uso terapêutico , Poliuretanos , Contratura Capsular em Implantes/veterinária , Mamoplastia/veterinária , Implante Mamário/veterinária , Implante Mamário/efeitos adversos , Ratos Wistar
7.
Prosthes. Lab. Sci ; 6(21): 38-44, 2016. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-837401

RESUMO

Na prática odontológica, o vazamento de gesso nos moldes é muitas vezes tardio, e a maioria é enviada ao laboratório para verter o gesso em até 72 horas. Portanto, os profissionais devem ficar cientes do tempo de atraso tolerável para o qual o material de moldagem permanecerá dimensionalmente preciso. O objetivo deste estudo foi avaliar a alteração dimensional de quatro marcas comerciais de silicone por reação de condensação: Speedex (Vigodent)®, Coltex/Coltoflax (Vigodent)®, Clonage (Nova DFL)® e Zetaplus/Oranwash (Zhermack)®, em função de seis diferentes tempos de vazamento de gesso, e sugerir o tempo máximo de armazenagem dos moldes. Para isso, foi confeccionado um modelo mestre com três cilindros metálicos, fixados em região de rebordo alveolar de uma maxila em acrílico, e 12 moldeiras individuais. A técnica de moldagem utilizada foi a do material em consistência densa e fluida em dois estágios. foram obtidos 72 modelos em gesso GC fujirock® EP melhorado tipo IV, os quais foram mensurados com paquímetro digital Mytutoyo®. Os resultados foram comparados ao modelo controle e aplicados ao teste de hipóteses "t de student". Concluiu-se que as marcas comerciais de silicone por reação de condensação Zetaplus® e Clonage® apresentaram modelos experimentais que não diferiram estatisticamente do modelo mestre para todos os tempos estudados. Já as marcas comerciais Coltex Coltoflax® e Speedex® apresentaram-se estatisticamente diferentes ao modelo mestre nos maiores tempos de armazenamento.


In dental practice, plaster casting is often late, and most are sent to the laboratory to pour the plaster in up to 72 hours. Therefore professionals should be aware of the tolerable delay time for which the molding material will remain dimensionally accurate. The objective of this study was to evaluate the dimensional alteration of four commercial brands of silicone by condensation reaction, Speedex (Vigodent)®, Coltex / Coltoflax (Vigodent)®,Clonage (Nova DFL)®, Zetaplus / Oranwash (Zhermack)®, in function of six different casting times, and suggest the maximum storage time of the molds. Therefore, a master model with three metal cylinders was made, fixed in the alveolar ridge region of an acrylic jaw, and 12 individual trays. The technique of molding used was that of the material in dense consistency and fluid in two stages. A total of 72 GC fujirock® EP improved plaster models were obtained, which were measured using a Mytutoyo® digital caliper. The results were compared to the control model and the "t student" hypothesis test was applied. It was concluded that the trademarks of silicone by condensation reaction Zetaplus® and Clonage® presented experimental models that did not differ statistically from the master model for all the studied times. Coltex Coltoflax® and Speedex® trademarks were statistically different from the master model in the longest storage times.


Assuntos
Humanos , Materiais para Moldagem Odontológica , Materiais Dentários , Precisão da Medição Dimensional , Elastômeros de Silicone , Silicones/análise
8.
Acta cir. bras. ; 27(12): 866-873, 2012. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-9131

RESUMO

PURPOSES: To evaluate whether polyurethane foam leads more intense foreign-body reaction than silicone foam. To compare the vascularization of the capsules surrounding the foam implants. To investigate if the capsule of polyurethane foam implanted has greater amount of collagen than that of silicone foam. METHODS: Sixty-four young male Wistar rats were allocated into two groups: polyurethane foam and silicone foam. Subcutaneous discs were implanted into the dorsum of the animals in both groups. The capsules were assessed 28 days, two months, three months and six months postoperatively. Microscopic analysis with H&E stain was performed to evaluate the acute and chronic inflammatory process, foreign-body reaction and neovascularization. The analysis with picrosirius red was performed using the ImageProPlus software, to measure the number of vessels and collagen types I and III. RESULTS: There were no statistical differences between the two groups regarding the acute and chronic inflammatory processes. All rats from the polyurethane group, in all times, exhibited moderate or intense foreign-body reaction, with statistic significant difference (p=0.046) when compared with the silicone group, in which the reaction was either mild or nonexistent at two months. Vascular proliferation was significantly different between the groups at 28 days (p=0.0002), with the polyurethane group displaying greater neovascularization with H&E stain. Similar results were obtained with picrosirius red, which revealed in the polyurethane group a much greater number of vessels than in the silicone group (p=0.001). The collagen area was larger in the polyurethane group, significantly at 28 days (p=0.001) and at two months (p=0.030). CONCLUSIONS: Polyurethane foam elicited more intense foreign-body reaction when compared with silicone foam. The number of vessels was higher in the capsules of the polyurethane foam implants 28 days after the operation. The capsule of the polyurethane foam implants showed a greater amount of collagen than that of the silicone foam implants.(AU)


OBJETIVOS: Avaliar, em relação ao uso de próteses, se a espuma de poliuretano apresenta maior reação de corpo estranho no organismo ao ser comparada com a espuma de silicone. Se há diferenças na vascularização das cápsulas formada ao redor das duas espumas implantadas. Se as cápsulas dos implantes de espuma de poliuretano apresentam quantidade maior de fibras colágenas ao serem comparadas com as da espuma de silicone. MÉTODOS: Utilizou-se 64 ratos albinos da linhagem Wistar, distribuídos em dois grupos de 34, grupo espuma de poliuretano e grupo espuma de silicone e receberam implantes discóides subcutâneos em seu dorso. Foram analisadas as cápsulas peri-implante com 28 dias, dois, três e seis meses após a introdução. A análise microscópica com H&E considerou as variáveis: inflamação aguda, inflamação crônica, reação de corpo estranho e neoformação vascular. A análise da coloração com picrosirius-red usando ImageProPlus considerou o número de vasos e colágeno tipo I e tipo III. RESULTADOS: Em relação à inflamação aguda e crônica, não foram encontradas diferenças estatísticas nos dois grupos. Todos os animais do grupo poliuretano, em todos os momentos, apresentaram reação de corpo estranho moderada ou intensa e foi encontrada diferença estatística significativa (p=0,046) ao serem comparados com o grupo silicone, cuja reação era ausente ou discreta aos dois meses. A neoformação vascular apresentou diferenças significativas nos dois grupos, aos 28 dias (p=0,0002); o grupo poliuretano com H&E apresentava quantidade maior de vasos neoformados e o mesmo ocorrendo com o picrosirius, cujo número de vasos era maior que no grupo silicone (p=0,001). A área de colágeno em todos os momentos foi maior no grupo poliuretano, sendo significativa com 28 dias (p=0,001) e com dois meses (p=0,030). CONCLUSÕES: A espuma de poliuretano apresentou maior reação de corpo estranho no organismo do que a espuma de silicone. A quantidade de vasos foi maior na cápsula da espuma de poliuretano com 28 dias após o implante. Aos 28 dias as cápsulas dos implantes de espuma de poliuretano apresentaram quantidade significativamente maior de colágeno do que as de espuma de silicone.(AU)


Assuntos
Animais , Ratos , Silicones/análise , Poliuretanos/análise , Corpos Estranhos/complicações , Rejeição de Enxerto , Ratos/fisiologia , Próteses e Implantes
9.
Acta cir. bras. ; 23(3): 287-293, May-June 2008. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-3644

RESUMO

PURPOSE: Evaluate by CT the use of porous vitreous carbon (PVC) and silicon (S) implants as the replacement bone in the craniofacial skeleton of rats. METHODS: 40 rats divided in: Group A (n=20) PVC submitted to the implant of a fragment in skull. After the euthanasia, the animals were divided into two subgroups: A I: 10 animals, studied in the 7th postoperative day (P.O) and AII: 10 animals, studied in the 28th P.O. In group B, S, 20 rats were submitted to S implant in the skull. All other steps were identical to group A, with designation of subgroups BI and BII. CT with beams in axial cuts of 1 mm thickness to obtain 3-D information It was used Hounsfield scale for evaluate the radio density of the implant. They were used non parametric tests to analyze the results. RESULTS: The 7th PO boss remained in the two groups, but for 28th PO, observed reduction in the volume of the implant in Group A, not observed in group B. CT studies noticed different radio densities around all of S prostheses (pseudo-capsule), that don't appeared in CPV implants. The S has remained unchanged in the CT, but the CPV has had a modification in its radio density (p<0,05), in all implants. CONCLUSION: In CT evaluation the implants of CPV have greater deformation that the S, which makes them not suitable for replacement of membranous bone in the rat skull.(AU)


OBJETIVO: Realizar avaliação através de tomografia computadorizada (TC) de implantes de carbono vítreo poroso (CVP) e silicone (S) para sua utilização na substituição óssea no esqueleto craniofacial de ratos. MÉTODOS: Foram utilizados 40 ratos Wistar divididos em: Grupo A (n=20), implantes subperiostais de CVP no crânio. Após o momento da eutanásia os animais foram divididos em dois subgrupos: A I: 10 animais, estudados no 7(0) dia pós-operatório (PO) e AII: 10 animais, estudados no 28(0) PO. No grupo B (n=20), os ratos foram submetidos ao implante de silicone no crânio. Todas outras etapas foram idênticas ao grupo A, com a designação de subgrupos BI e BII. Foi realizada tomografia computadorizada com cortes axiais de 1 mm de espessura para obtenção de imagens tridimensionais. A escala de Hounsfield foi utilizada para avaliação da radiodensidade dos implantes. Testes estatísticos não paramétricos foram utilizados para analisar os resultados. RESULTADOS: O volume do implante foi mantido ao 7(0) PO nos dois grupos, mas ao 28(0) PO, ocorreu uma redução no volume do implante no grupo A, não observada no grupo B. Os estudos tomográficos demonstraram a presença de uma pseudo-cápsula ao redor dos implantes no grupo B, não observada nos implantes de CVP. Os implantes de silicone permaneceram inalterados na TC, mas os de CVP apresentaram modificação na sua radiodensidade e deformação (p<0,05). CONCLUSÃO: Na avaliação, através de TC, os implantes de CPV apresentam maior deformação que os de S, o que os torna inadequados para substituição do osso membranoso no crânio de ratos.(AU)


Assuntos
Animais , Carbono/análise , Silicones/análise , Anormalidades Craniofaciais/veterinária
10.
Säo Paulo; s.n; 1999. 95 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-246737

RESUMO

A finalidade da pesquisa foi determinar a recuperaçäo elástica, por meio de um elasticímetro, de 4 siliconas de massa (Aquasil, Express, President e Provil), misturadas sob 12 combinaçöes com luvas usadas sem ou com lavagem e uso ou näo de espátula para mistura inicial. Também foram determinados os tempos até alcançar recuperaçäo elástica 100 por cento, quando isto é possível. As conclusöes foram: cada silicona apresenta um comportamento diferente; a Aquasil comportou-se bem sob todas as combinaçöes; a Express falhou sem uso de espátula, com a luva Safederm; a President falhou com a luva Satari sem lavar e sem uso de espátula; a Provil falhou com as luvas Safederm e Satari sem uso de espátula; em dúvida do comportamento dos materiais, o profissional deve usar a espátula para a mistura inicial


Assuntos
Elasticidade , Silicones/análise , Materiais Dentários
11.
Rev. odontol. Univ. Säo Paulo ; 11(2): 93-7, abr.-jun. 1997. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-192836

RESUMO

Os autores pesquisaram três marcas comerciais de silicones acéticos de fabricaçäo nacional e os submeteram a testes de dureza "Shore A" e de resistência ao rasgamento, com o objetivo de verificar qual proporçäo desses materiais misturados ao silicone Silastic 4-4210 mais se aproximaria dos valores considerados ideiais para as propriedades físicas dos silicones. Concluíram que, à medida em que a quantidade de Silastic 4-4210 era aumentada, as características físicas dos silicones acéticos estudados pioravam. Estes, porém, possuem certas vantagens sobre os materiais "in natura", em funçäo da maior sensaçäo de textura de pele natural e da maior liberdade de escolha do profissional quanto às qualidades desejadas para a confecçäo de próteses faciais


Assuntos
Silicones/análise , Silicones/uso terapêutico , Prótese Maxilofacial/reabilitação , Prótese Maxilofacial/tendências , Testes de Dureza , Fenômenos Físicos
13.
RPG rev. pos-grad ; 3(2): 142-7, abr.-jun. 1996. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-197589

RESUMO

Os autores selecionaram três marcas comerciais de silicones acéticos mais encontrados no mercado nacional e os submeteram a teste de alteraçäo dimensional, alongamento de ruptura e resistência à traçäo, com o fito de verificar qual proporçäo desses materiais misturados ao silicone Silastic 4-4210, de procedência norte-americana, mais se aproximaria dos valores considerados ideais para as propriedades físicas dos mesmos. Concluíram que os silicones estudados se comportam de modo semelhante e, à medida que a quantidade de Silastic 4-4210 é aumentada, observa-se uma piora nas características físicas dos materiais


Assuntos
Teste de Materiais , Prótese Maxilofacial , Silicones/administração & dosagem , Silicones/análise
14.
In. Feller, Christa; Bottino, Marco Antonio. Atualizaçäo na clínica odontológica: a prática da clínica geral. s.l, Artes Médicas, 1994. p.281-93, ilus. (BR).
Monografia em Português | LILACS, BBO - Odontologia | ID: lil-187706
16.
Rev. paul. odontol ; 13(4): 8-16, jul.-ago. 1991. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-858755

RESUMO

Os autores procuraram verificar a estabilidade dimensional de um material de moldagem de alta precisão, no caso a silicona de condensação, frente a três fatores: alivio ou não da silicona densa, meio de estocagem (imerso em água e água confinada), e tempo de armazenamento


Assuntos
Materiais para Moldagem Odontológica/análise , Silicones/análise
17.
Bauru; s.n; 1991. 160 p. ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-222752

RESUMO

Este estudo foi desenvolvido para verificar as alteraçöes dimensionais em sete diferentes marcas comerciais de gesso, sendo seis do tipo IV e uma do tipo III, quando provenientes de moldes de uma silicona de adiçao comumente encontrada em nosso mercado (Provil H). Foram realizados inicialmente 70 troquéis de gesso, 10 para cada marca comercial, utilizando-se um dispositivo especial para moldagem e análise dos desajustes desenvolvido por ARAÚJO; JORGENSEN 4, em 1985. Os desajustes foram medidos através de um anel de mediçäo em microscópio de profundidade, onde foram encontradas diferenças entre os materiais empregados. Numa segunda fase, 42 novos troquéis receberam ceroplastia e peças fundidas em ligas de níquel cromo foram obtidas, os desajustes foram medidos agora sobre o troquel padräo de aço, sem que estas sofressem qualquer tipo de usinagem, identificando peças provenientes de gesso mais preciso (Vel-Mix) um menor desajuste, e peças provenientes do Herostone um maior desajuste


Assuntos
Sulfato de Cálcio/análise , Materiais para Moldagem Odontológica/análise , Reabilitação Bucal/métodos , Silicones/análise
18.
Rev. odontol. Univ. Säo Paulo ; 4(3): 212-5, jul.-set. 1990. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-858613

RESUMO

Moldagens de um modelo confeccionado em aço inoxidável com o formato de um dente preparado para coroa total foram feitas, a 37ºC, utilizando-se uma silicona de adição (Presidente R.). Dois tamanhos de moldeira foram utilizados, uma para obter uma camada de material de moldagem de 1 mm de espessura, na região gengival do preparo e outra para obter uma camada de 4 mm. O modelo padrão de aço, podia apresentar retenções para apical da margem gengival, conforme descrito anteriormente, permitindo variar a profundidade de retenção em 0,5 ou 1,5 mm. Troquéis de gesso eram obtidos: 1) após resfriar os moldes a 22ºC por 10 minutos e 2) após resfriar os moldes a 22ºC por 10 minutos e posteriormente reaquecê-los a 37ºC, por 30 minutos. Os resultados mostraram que reaquecer os moldes à temperatura da boca melhora a precisão dos moldes e que as retenções têm uma influência definida mas pequena sobre a precisão dos moldes de silicona de adição


Assuntos
Materiais para Moldagem Odontológica , Silicones/análise , Técnicas In Vitro
19.
Clin Exp Rheumatol ; 8(1): 17-22, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2347131

RESUMO

The occurrence of lymphadenopathies was investigated in 23 patients with diverse rheumatic conditions who had silastic prosthesis in joints of the hands, to determine whether these adenopathies were due to the presence of silicone particles. Five cases had clinically detectable lymph node enlargement and tissue samples were studied by light and scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDXA). In 3 out of the 5 cases foreign body granulomas were observed by light microscopy, SEM showing a highly irregular distribution of foreign body material with a peak for silicone by EDXA. Foreign body particle distribution closely correlated with silicone concentration. No granulomas were found in the two remaining patients with adenopathies who presented a non-specific reactive lymphadenitis. Our findings show that silicone lymphadenopathy is a more frequent complication (13%) of silastic arthroplasty than is usually recognized and therefore should be considered in the differential diagnosis of patients with lymph node enlargement who have previously received a silicone arthroplasty.


Assuntos
Mãos , Prótese Articular/efeitos adversos , Doenças Linfáticas/etiologia , Silicones/efeitos adversos , Adulto , Idoso , Artrite Reumatoide/cirurgia , Microanálise por Sonda Eletrônica , Feminino , Humanos , Doenças Linfáticas/patologia , Masculino , Pessoa de Meia-Idade , Silicones/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA