Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Braz. j. otorhinolaryngol. (Impr.) ; Braz. j. otorhinolaryngol. (Impr.);82(6): 722-736, Oct.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-828244

RESUMO

Abstract Introduction: Auditory Neuropathy/Dyssynchrony is a disorder characterized by the presence of Otoacoustic Emissions and Cochlear Microphonic Potentials, an absence or severe alteration of Brainstem Evoked Auditory Potential, auditory thresholds incompatible with speech thresholds and altered acoustic reflexes. The study of the Cochlear Microphonic Potential appears to be the most important tool for an accurate diagnosis of this pathology. Objective: Determine the characteristics of the Cochlear Microphonic in Auditory Neuropathy/Dyssynchrony using an integrative review. Methods: Bibliographic survey of Pubmed and Bireme platforms and MedLine, LILACS and SciELO data banks, with standardized searches up to July 2014, using keywords. Criteria were established for the selection and assessment of the scientific studies surveyed, considering the following aspects: author, year/place, degree of recommendation/level of scientific evidence, objective, sample, age range, mean age, tests, results and conclusion. Results: Of the 1959 articles found, 1914 were excluded for the title, 20 for the abstract, 9 for the text of the article, 2 for being repeated and 14 were selected for the study. Conclusion: The presence of the Cochlear Microphonic is a determining finding in the differential diagnosis of Auditory Neuropathy/Dyssynchrony. The protocol for the determination of Cochlear Microphonic must include the use of insert earphones, reverse polarity and blocking the stimulus tube to eliminate electrical artifact interference. The amplitude of the Cochlear Microphonic in Auditory Neuropathy/Dyssynchrony shows no significant difference from that of normal individuals. The duration of the Cochlear Microphonic is longer in individuals with Auditory Neuropathy/Dyssynchrony.


Resumo Introdução: A Neuropatia/Dessincronia Auditiva é uma doença caracterizada pela presença das Emissões Otoacústicas e do Microfonismo Coclear, com ausência ou grave alteração do Potencial Evocado Auditivo de Tronco Encefálico, limiares auditivos incompatíveis com limiares vocais e reflexos acústicos alterados. O estudo do Microfonismo Coclear parece ser a ferramenta mais importante para um diagnóstico preciso desta patologia. Objetivo: Verificar por meio de uma revisão integrativa as características do Microfonismo Coclear na Neuropatia/Dessincronia Auditiva. Método: Levantamento bibliográfico nas plataformas Pubmed e Bireme e nas bases de dados MedLine, LILACS e SciELO, com buscas padronizadas até julho de 2014, utilizando-se palavraschave. Para a seleção e avaliação dos estudos científicos levantados, foram estabelecidos critérios, contemplando os aspectos: autor, ano/local, grau de recomendação/nível de evidência científica, objetivo, amostra, faixa etária, média de idade em anos, testes, resultados e conclusão. Resultados: Dos 1959 artigos encontrados, 1914 foram excluídos pelo título, 20 pelo resumo, nove pela leitura do artigo, dois eram repetidos e 14 foram selecionados para o estudo. Conclusão: A presença do Microfonismo Coclear é um achado determinante no diagnóstico diferencial da Neuropatia/Dessincronia auditiva. O protocolo de registro do Microfonismo Coclear deve contar com o uso de fones de inserção, a inversão da polaridade e o bloqueio do tubo do estímulo para impedir a interferência de artefato elétrico. A amplitude do Microfonismo Coclear na Neuropatia/Dessincronia auditiva não apresenta diferença significante entre a amplitude do Microfonismo Coclear em ouvintes normais. A duração do Microfonismo Coclear é maior em indivíduos com Neuropatia/Dessincronia auditiva.


Assuntos
Humanos , Limiar Auditivo/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Potenciais Microfônicos da Cóclea/fisiologia , Perda Auditiva Central/fisiopatologia
2.
Braz J Otorhinolaryngol ; 82(6): 722-736, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27177976

RESUMO

INTRODUCTION: Auditory Neuropathy/Dyssynchrony is a disorder characterized by the presence of Otoacoustic Emissions and Cochlear Microphonic Potentials, an absence or severe alteration of Brainstem Evoked Auditory Potential, auditory thresholds incompatible with speech thresholds and altered acoustic reflexes. The study of the Cochlear Microphonic Potential appears to be the most important tool for an accurate diagnosis of this pathology. OBJECTIVE: Determine the characteristics of the Cochlear Microphonic in Auditory Neuropathy/Dyssynchrony using an integrative review. METHODS: Bibliographic survey of Pubmed and Bireme platforms and MedLine, LILACS and SciELO data banks, with standardized searches up to July 2014, using keywords. Criteria were established for the selection and assessment of the scientific studies surveyed, considering the following aspects: author, year/place, degree of recommendation/level of scientific evidence, objective, sample, age range, mean age, tests, results and conclusion. RESULTS: Of the 1959 articles found, 1914 were excluded for the title, 20 for the abstract, 9 for the text of the article, 2 for being repeated and 14 were selected for the study. CONCLUSION: The presence of the Cochlear Microphonic is a determining finding in the differential diagnosis of Auditory Neuropathy/Dyssynchrony. The protocol for the determination of Cochlear Microphonic must include the use of insert earphones, reverse polarity and blocking the stimulus tube to eliminate electrical artifact interference. The amplitude of the Cochlear Microphonic in Auditory Neuropathy/Dyssynchrony shows no significant difference from that of normal individuals. The duration of the Cochlear Microphonic is longer in individuals with Auditory Neuropathy/Dyssynchrony.


Assuntos
Limiar Auditivo/fisiologia , Potenciais Microfônicos da Cóclea/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Perda Auditiva Central/fisiopatologia , Emissões Otoacústicas Espontâneas/fisiologia , Humanos
3.
Rev. otorrinolaringol. cir. cabeza cuello ; 71(1): 57-64, abr. 2011. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-592000

RESUMO

El desorden del espectro de neuropatía auditiva (DENA) describe una condición en la cual se observa o se ha observado emisiones otoacústicas (EOA) junto con potenciales evocados auditivos de tronco (PEAT) anormales o ausentes. Su identificación se basa en la presencia de potencial microfónico coclear (PMIC) junto con un PEAT anormal o ausente y EOA presentes o antecedentes de su presencia. Los umbrales tonales pueden encontrarse entre los rangos de normalidad hasta pérdidas auditivas profundas. El reconocimiento del habla generalmente se encuentra afectado particularmente en presencia de ruido de fondo, sin embargo en algunos individuos se mantiene conservado (sin ruido). Se presenta caso clínico de un recién nacido de sexo femenino de pretérmino de 29 semanas y 810 grs (GIII), apgar 7/8, presenta displasia broncopulmonar, sospecha de infección connatal tratada, hiperbilirrubinemia (max 11 mg/dl) tratada con fototerapia. Es derivada al Servicio de Otorrinolaringología para su evaluación auditiva. La evaluación auditiva realizada corresponde a potenciales evocados auditivos de tronco (PEAT), impedanciometria, audiometría de campo de respuesta reflejas y emisiones oto-acústicas. Los resultados obtenidos concuerdan con lo descrito en la literatura para un DENA.


Auditory neuropathy spectrum disorder (ANSD) describes a condition in which it is possible to find otoacoustic emissions (OAE) in presence of abnormal or absent auditory brainstem evoked potentials (ABR). The pure tone thresholds may show a spectrum from normal to profound hearing loss. Speech recognition is often affected in presence of background noise, but in some individuals remains intact. We report a case of a pre term newborn (female) of 29 weeks and 810 grams, Apgar 7/8, bronchopulmonary dysplasia, suspected connatal infection, and hyperbilirubinemia (max 11 mg / dl). She was referred to Hospital Padre Hurtado for hearing assessment. The hearing test performed were an ABR, tympanometry & acoustic reflex, visual reinforcement audiometry and otoacoustic emissions. The results are consistent with those described in the literature for ANSD.


Assuntos
Humanos , Feminino , Recém-Nascido , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Testes Auditivos/métodos , Perda Auditiva Central/diagnóstico , Perda Auditiva Central/fisiopatologia , Eletrofisiologia , Potenciais Microfônicos da Cóclea/fisiologia , Recém-Nascido Prematuro
4.
Braz J Otorhinolaryngol ; 74(1): 132-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18392514

RESUMO

UNLABELLED: The brainstem auditory evoked potential (BAEP) is being extensively used as a method for the evaluation of cochlear function in individuals with diagnosis of auditory neuropathy/auditory dyssynchrony (AN/AD). In the absence of otoacoustic emissions, many cases of AN/AD have been diagnosed by the presence of CM identified in the BAEP. AIM: to demonstrate the clinical applicability of extratympanic electrocochleography (ET-Ecochg) in the differential diagnosis of AN/AD compared to the BAEP. METHOD: a 4-year-old child with a diagnosis of AN/AD seen at the Audiological Research Center was submitted to ET-Ecochg with a 2000 Hz tone burst in rarefaction and condensation polarities. RESULTS: the ET-Ecochg exam was illustrated. Using an appropriate protocol, it was possible to demonstrate CM and to confirm it in the Ecochg, with a recording quality superior to that obtained in the BAEP. CONCLUSION: ET-Ecochg permitted a more detailed analysis of CM compared to the BAEP, thus showing clinical applicability for the investigation of cochlear function in AN/AD.


Assuntos
Transtornos da Percepção Auditiva/diagnóstico , Potenciais Microfônicos da Cóclea/fisiologia , Eletrofisiologia/métodos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Perda Auditiva/diagnóstico , Doenças do Nervo Vestibulococlear/diagnóstico , Transtornos da Percepção Auditiva/fisiopatologia , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Reprodutibilidade dos Testes , Doenças do Nervo Vestibulococlear/fisiopatologia
5.
Rev. bras. otorrinolaringol ; Rev. bras. otorrinolaringol;74(1): 132-136, jan.-fev. 2008. ilus
Artigo em Inglês, Português | LILACS | ID: lil-479840

RESUMO

O potencial evocado auditivo de tronco encefálico (PEATE) vem sendo amplamente utilizado como método para avaliação da função coclear em indivíduos com diagnóstico de neuropatia/dessincronia auditiva (NA/DA). Na ausência das emissões otoacústicas, muitos casos de NA/DA foram diagnosticados pela presença do microfonismo coclear (MC) identificado no PEATE. OBJETIVO: Demonstrar a aplicabilidade clínica da eletrococleografia extratimpânica (Ecog-ET) no diagnóstico diferencial da NA/DA quando comparada ao PEATE. MATERIAL E MÉTODO: Uma criança com 4 anos de idade, com diagnóstico de NA/DA atendida no Centro de Pesquisas Audiológicas realizou a Ecog-ET com tone burst de 2000Hz nas polaridades de rarefação e condensação. RESULTADOS: Ilustrou-se o registro da Ecog-ET. Com a utilização de protocolo apropriado, o MC pode ser evidenciado e confirmado na Ecog, com qualidade de registro superior ao obtido no PEATE. CONCLUSÃO: A Ecog-ET permitiu uma análise mais detalhada do MC quando comparada ao PEATE tendo, portanto aplicabilidade clínica na investigação da função coclear na NA/DA.


The brainstem auditory evoked potential (BAEP) is being extensively used as a method for the evaluation of cochlear function in individuals with diagnosis of auditory neuropathy/auditory dyssynchrony (AN/AD). In the absence of otoacoustic emissions, many cases of AN/AD have been diagnosed by the presence of CM identified in the BAEP. AIM: to demonstrate the clinical applicability of extratympanic electrocochleography (ET-Ecochg) in the differential diagnosis of AN/AD compared to the BAEP. METHOD: a 4-year-old child with a diagnosis of AN/AD seen at the Audiological Research Center was submitted to ET-Ecochg with a 2000 Hz tone burst in rarefaction and condensation polarities. RESULTS: the ET-Ecochg exam was illustrated. Using an appropriate protocol, it was possible to demonstrate CM and to confirm it in the Ecochg, with a recording quality superior to that obtained in the BAEP. CONCLUSION: ET-Ecochg permitted a more detailed analysis of CM compared to the BAEP, thus showing clinical applicability for the investigation of cochlear function in AN/AD.


Assuntos
Pré-Escolar , Feminino , Humanos , Transtornos da Percepção Auditiva/diagnóstico , Potenciais Microfônicos da Cóclea/fisiologia , Eletrofisiologia/métodos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Perda Auditiva/diagnóstico , Doenças do Nervo Vestibulococlear/diagnóstico , Transtornos da Percepção Auditiva/fisiopatologia , Diagnóstico Diferencial , Reprodutibilidade dos Testes , Doenças do Nervo Vestibulococlear/fisiopatologia
6.
Hear Res ; 194(1-2): 25-30, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15276673

RESUMO

These experiments were designed to investigate the effect of noise, sleep, and gentamicin on the cochlear microphonic (CM) of the guinea pigs. Are the changes observed due to intrinsic cochlear phenomena or to efferent system actions? To answer this question, noise exposure together with efferent system blockade by gentamicin administration was performed. In the normal (non-treated) animal, noise exposure decreased both variability and amplitude of the tone evoked CM in about the first 10 min while the physiological modulation of slow wave sleep increasing the CM is not present. Following administration of gentamicin, noise no longer affect the CM in about the first 10 min, although it produces amplitude and variability increments. The influence of slow wave sleep on the CM is not altered. Thus, gentamicin does not block the CM sleep/wakefulness related shifts. The data were discussed in terms of the influence of gentamicin on the olivo-cochlear bundle. It was hypothesized that the effects of noise on the CM is a result of both peripheral and central influences.


Assuntos
Antibacterianos/efeitos adversos , Potenciais Microfônicos da Cóclea/fisiologia , Gentamicinas/efeitos adversos , Ruído/efeitos adversos , Sono/fisiologia , Vigília/fisiologia , Animais , Antibacterianos/administração & dosagem , Potenciais Microfônicos da Cóclea/efeitos dos fármacos , Vias Eferentes/efeitos dos fármacos , Vias Eferentes/fisiologia , Gentamicinas/administração & dosagem , Cobaias
7.
Rev. bras. otorrinolaringol ; Rev. bras. otorrinolaringol;66(1): 38-45, jan.-fev. 2000. tab, graf
Artigo em Português | LILACS | ID: lil-270326

RESUMO

Introduçäo: As emissöes otoacústicas refletem, preferencialmente, o status funcional da cóclea. Como a passagem da informaçäo sonora, tanto em sua direçäo aferente quanto na eferente, depende também das condiçöes da orelha média, säo vários os fatores que podem regular o registro final das emissöes otoacústicas. Objetivos: Este estudo teve o objetivo de verificar o comportamento das respostas cocleares captadas através de EOAT e de EOAPD em adultos jovens e em idosos com funçäo normal de orelha média, observando-se a amplitude das respostas nas duas condiçöes. Resultados: Foram analisados os resultados obtidos em 40 orelhas de 20 adultos jovens entre 20 e 25 anos de idade, e de 30 orelhas de 15 idosos entre 60 e 75 anos de idade, ambos os grupos sem queixa auditiva e com nível de audiçäo dentro dos limites da normalidade. Conclusäo: Comparando-se as emissöes otoacústicas transientes (EOATs) com as emissöes otoacústicas por produto de distorçäo (EOAPD), as primeiras sofreram maiores impedimentos em sua captaçäo, tanto em adultos jovens quanto em idosos


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Emissões Otoacústicas Espontâneas/fisiologia , Potenciais Microfônicos da Cóclea/fisiologia , Audição/fisiologia , Percepção Auditiva , Estimulação Acústica/métodos
8.
Bol. méd. Hosp. Infant. Méx ; 52(10): 566-71, oct. 1995. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-164540

RESUMO

Introducción. Este estudio fue realizado con el fin de conocer la prevalencia de las emisiones otoacústicas espontáneas y provocadas por sonidos transitorios en la población pediátrica de alto riesgo. Material y métodos. Se examinaron 44 niños con edad promedio de 3.7 años, en quienes se comprobó que tenían audición normal y que estaban libres de infecciones y disfunciones del oído medio. Resultados. Se encontró una prevalencia de 56.8 por ciento de emisiones otoacústicas espontáneas y un 73.8 por ciento de emisiones otoacústicas provocadas. Estos resultados son comparables con los encontrados por otros autores en poblaciones similares. Conclusiones. Este método diagnóstico, además de ser un procedimiento rápido comparado con los potenciales provocados auditivos de tallo cerebral y la electrococleografía, nos informa sobre la función coclear con el fin de obtener una detección temprana de alteraciones auditivas, aún las que no son permanentes, como sucede en los cambios temporales que resultan de la ototoxicidad. Además separa las lesiones colcleares de las neurológicas, o madurativas, de la vía auditiva por ser una señal preneural


Assuntos
Criança , Humanos , Masculino , Feminino , Cóclea/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Potenciais Microfônicos da Cóclea/fisiologia
9.
Rev. otorrinolaringol. cir. cabeza cuello ; 55(1): 25-33, abr. 1995. graf
Artigo em Espanhol | LILACS | ID: lil-195189

RESUMO

Al estimular el oído con dos tonos puros simultáneos (primarios), se obtienen respuestas cocleares no sólo a los tonos primarios sino también a productos de distorsión (PDs) con frecuencia que son combinaciones de las frecuencias de los estímulos. Estos PDs han sido estudiados en experimentos psicofísicos, en registros de fibras aisladas del nervio coclear y mas recientemente en emisiones otoacústicas medidas en el meato externo. Hemos montado la técnica de medición de PDs en emisiones otoacústicas en la chinchilla usando una sonda acústica construida en nuestro laboratorio. Se presentaron simultáneamente dos tonos primarios en el conducto auditivo externo por medio de fonos miniatura ubicados en la sonda. Esta presión se amplificó, se muestreó y se analizó para obtener sus componentes espectorales. Resultados obtenidos en 8 chinchillas muestran que, para tonos primarios (Ÿ1 y Ÿ2) con frecuencias entre 2 kHz y 8 kHz, se registran PDs a frecuencias tanto menores (p.ej., 2Ÿ1-Ÿ2), como mayores (p.ej., 2Ÿ2-Ÿ1), que las de los tonos primarios. Los PDs a 2Ÿ1-Ÿ2 alcanzan niveles de hasta 24 dB bajo el nivel de los tonos primarios, mientras que los de frecuencia 2Ÿ2-Ÿ1 son de menor intensidad. Se discuten algunas aplicaciones clínicas de las emisiones de PDs en humanos


Assuntos
Animais , Cóclea/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Chinchila/fisiologia , Estimulação Acústica/métodos , Potenciais Microfônicos da Cóclea/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA