Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Molecules ; 25(12)2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32630475

RESUMO

A magnetic solid phase extraction technique followed by liquid chromatography with a fluorescence detector for naproxen analysis in human urine samples was developed. The method includes the extraction of naproxen with a magnetic solid synthetized with magnetite and poly 4-vinylpriridine, followed by the magnetic separation of the solid phase and desorption of the analyte with methanol. Under optimal conditions, the linear range of the calibration curve was 0.05-0.60 µg L-1, with a limit of detection of 0.02 µg L-1. In all cases values of repeatability were lower than 5.0% with recoveries of 99.4 ± 1.3%. Precision and accuracy values are adequate for naproxen (Npx) analysis in urine samples.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Magnetismo , Naproxeno/urina , Polímeros/química , Polivinil/química , Extração em Fase Sólida/métodos , Humanos
2.
Anal Bioanal Chem ; 374(3): 451-9, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12373394

RESUMO

First- and second-order multivariate calibration of fluorescence data have been compared as regards the determination of anti-inflammatories and metabolites in the biological fluids serum and urine. The simultaneous resolution of naproxen-salicylic acid mixtures in serum and naproxen-salicylic acid-salicyluric acid mixtures in urine was accomplished and employed for a discussion of the relative advantages of the applied chemometric tools. The analysis of second-order fluorescence excitation-emission matrices was performed using iteratively reweighted generalized rank annihilation method (IRGRAM), parallel factor analysis (PARAFAC), and self-weighted alternating trilinear decomposition (SWATLD). The results were compared with first-order fluorescence emission data analyzed with partial least-squares regression (PLS). In all cases, the performance of the methods was improved through the formation of inclusion complexes of the analytes with beta-cyclodextrin. The concentration ranges in which the analytes could be determined were as follows: naproxen, 0-250 ng mL(-1) in serum and 0-200 ng mL(-1) in urine; salicylic acid, 0-500 ng mL(-1) in serum and 0-300 ng mL(-1) in urine, and salicyluric acid, 0-300 ng mL(-1) in urine.


Assuntos
Anti-Inflamatórios não Esteroides/sangue , Anti-Inflamatórios não Esteroides/urina , Espectrometria de Fluorescência/métodos , beta-Ciclodextrinas , Calibragem , Ciclodextrinas/química , Hipuratos/urina , Humanos , Análise dos Mínimos Quadrados , Análise Multivariada , Naproxeno/sangue , Naproxeno/urina , Ácido Salicílico/sangue , Ácido Salicílico/urina , Espectrometria de Fluorescência/normas