Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 187: 113373, 2020 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-32473548

RESUMO

The association of minoxidil sulphate and latanoprost is currently emerging as a promising strategy for the treatment of androgenic alopecia, which is the most common type of scalp hair loss. In order to support the development of new pharmaceutical products containing such drugs combination, this study proposes a simple and efficient LC-MS bioanalytical method to simultaneously quantify minoxidil sulphate and latanoprost in different skin layers. Compounds separation was performed by liquid chromatography using a C18 column with gradient elution of a mobile phase composed of 0.1 % formic acid in acetonitrile and water at a flow rate of 0.5 mL min-1. Determinations were executed using mass spectrometry equipped with an ESI interface operating in a positive ionization mode. Quantification was performed using selective ion mode monitoring of m/z 210.1 for minoxidil sulphate and 433.3 for latanoprost. The matrix effect was very pronounced in samples containing some skin layers or electrolyte solution. Accordingly, a calibration curve for each contaminant group was built, leading to correlation coefficient values higher than 0.99. Additionally, lower limits of detection and quantification were obtained, and precision (repeatability and intermediate precision) achieved results with a coefficient of variation less than 15 %. Drug recovery from skin samples was higher than 70 %, fulfilling the recommendations. Also, the bioanalytical method was successfully tested in in vitro skin penetration studies proving its effectiveness in the development of topical formulations containing both drugs.


Assuntos
Cromatografia Líquida/métodos , Latanoprosta/análise , Espectrometria de Massas/métodos , Minoxidil/análogos & derivados , Administração Cutânea , Animais , Calibragem , Limite de Detecção , Minoxidil/análise , Reprodutibilidade dos Testes , Pele/metabolismo , Suínos
2.
Anal Sci ; 22(1): 91-4, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16429780

RESUMO

The electrochemical behavior and amperometric-FIA quantification of minoxidil at a glassy carbon electrode is described. The procedure is based on electrochemical oxidation at 0.800 V (vs. Ag/AgCl/NaCl(3 M) in a phosphate buffer solution. Minoxidil was determined over the range 1 x 10(-7) - 1 x 10(-4) M. Different analytical parameters and electrode stability were analyzed to obtain the best electrode performance. The optimal conditions were: working potentials, 0.800 V; flow rate, 0.74 mL min(-1); and solution pH 7.0. This system allowed a sampling rate of 120 samples per hour without any pretreatment. The proposed method was used for minoxidil quantification in pharmaceutical preparations with satisfactory results. The accuracy of FIA-amperometric method was established by a comparison with the conventional UV determination technique using a paired t-test indicating the absence of systematic errors.


Assuntos
Minoxidil/análise , Preparações Farmacêuticas/química , Eletroquímica/métodos , Análise de Injeção de Fluxo/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA