Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Feline Med Surg ; 23(4): 375-388, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33206028

RESUMO

OBJECTIVES: The aim of this study was to describe the treatment and outcome of acetabular and other pelvic fractures in cats with patellar fracture and dental anomaly syndrome (PADS) and to provide advice on how to manage these cases in practice. METHODS: Data were collated on cats with PADS that were reported to have sustained pelvic fractures or had fractures or fissures of the pelvis identified on submitted radiographs. The details of the fractures were recorded, in addition to any treatment and outcome information. RESULTS: Of the 215 cases reported with PADS, 58 cats (27%) were found to have pelvic fractures, none of which were known to have resulted from significant trauma. There were 101 fractures in total and of these 15 were treated with surgery, including 10 acetabular fractures, two ilial, two pubic and one ischial fracture. Screw loosening and loss of fracture reduction was seen in four of the surgically treated fractures (two pubic fractures, one ilial and one acetabular fracture). Fourteen cats were euthanased as a direct result of a fracture occurring. While most pelvic fractures healed uneventfully, some cats remained intermittently lame, but it was not always possible to determine the cause of the lameness from the information available and because all cats had concurrent patellar fractures. CONCLUSIONS AND RELEVANCE: Many of the pelvic fractures healed with conservative management. Fractures involving articular surfaces such as acetabular fractures may benefit from surgical stabilisation as surgery may offer the benefits of articular fracture repair with improved joint congruency and a faster return to normal activity.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Fraturas Intra-Articulares , Animais , Parafusos Ósseos , Fixação de Fratura/veterinária , Fixação Interna de Fraturas/veterinária , Fraturas Ósseas/cirurgia , Fraturas Ósseas/veterinária , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/veterinária , Fraturas Intra-Articulares/veterinária , Radiografia
2.
Pesqui. vet. bras ; 37(12): 1474-1478, dez. 2017. ilus
Artigo em Português | VETINDEX | ID: vti-743409

RESUMO

Tendo em vista as vantagens das hastes intramedulares bloqueadas (HIB) em relação às placas ósseas na estabilização femoral, o presente estudo objetivou avaliar a exequibilidade e eficácia da aplicação da HIB pós osteotomia intertrocantérica varizante (OIV). Submeteu-se 10 cadáveres caninos à OIV. Nos antímeros esquerdos obteve-se a estabilização por meio de HIB (grupo HIB) e, nos direitos, com placas de compressão dinâmica (grupo placa). Foram comparados os ângulos de Norberg e de inclinação da cabeça e colo femoral (ICF) antes (T0) e após (T1) a OIV. O tempo dispendido para a colocação dos implantes e resultados de resistência biomecânica à compressão e torção também foram confrontados entre os grupos. Houve aumento do ângulo de Norberg entre T0 (106,84®5,55o) e T1 (111,22o®3,89), apenas no grupo HIB (p<0,05). No entanto, redução do ângulo de ICF após OIV (T1) foi observada tanto no grupo placa (T0=127,6®4,70o e T1=110,06®10,61o, p<0,05) quanto no grupo HIB (T0=126,43®5,87o e T1=116,87®8,62o, p<0,05). Os tempos de colocação dos implantes não diferiram estatisticamente e apenas o teste biomecânico de compressão revelou diferença entre os grupos, com maior resistência (P=0,033) do grupo placa (863,3®74,46N/mm) em relação ao grupo HIB (586,7®44,10N/mm). Deste modo, a estabilização por meio de HIB foi factível e eficaz. Embora o resultado biomecânico de compressão tenha demonstrado maior fragilidade da HIB em relação à placa de compressão, seus valores estão acima das forças atuantes, reportadas na literatura, na deambulação normal de cão.(AU)


Considering the advantages of the interlocking intramedullary nail (IN) in relation to bone plates in the femoral stabilization, this study aimed to evaluate the feasibility and effectiveness of IN application post intertrochanteric varus osteotomy (IVO). For this purpose, 10 canines cadavers were used. On the left femurs, the fixation was obtained with IN (IN group) and rights fixed with dynamic compression plates and screws (plate group). Was compared the angles of Norberg and inclination of the head and femoral neck (IHF) before (T0) and after (T1) IVO. The results of time spent for placement of implants and biomechanical resistance to compression and torsion were also confronted between groups. There was an increase of the Norberg angle between T0 (106.84®5.55o) and T1 (111.22o®3.89), only in IN group (p<0.05). However, reduction of IHF angle after IVO (T1) was observed in both, the plate group (T0=127.6®4.70o e T1=110.06®10.61o, p<0.05) and IN group (T0=126.43®5.87o e T1=116.87® 8.62 o, p<0.05). The placement times of the implants did not differ statistically and only the compression biomechanical test revealed differences between groups, with greater resistance (P=0.033) of the plate group (863.3®74.46N/mm) compared to IN group (586.7®44.10N/mm). Thus, stabilization through IN was feasible and effective. Although the compression biomechanical results has demonstrated a higher fragility of IN in relation to the compression plate, their values are above the forces, reported in literature, acting in normal dog gait.(AU)


Assuntos
Animais , Cães , Osteotomia/veterinária , Próteses e Implantes/veterinária , Placas Ósseas/veterinária , Fixação Intramedular de Fraturas/veterinária , Displasia Pélvica Canina/terapia , Fraturas do Quadril/veterinária , Procedimentos Ortopédicos/veterinária
3.
Pesqui. vet. bras ; Pesqui. vet. bras;37(12): 1474-1478, dez. 2017. ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-895384

RESUMO

Tendo em vista as vantagens das hastes intramedulares bloqueadas (HIB) em relação às placas ósseas na estabilização femoral, o presente estudo objetivou avaliar a exequibilidade e eficácia da aplicação da HIB pós osteotomia intertrocantérica varizante (OIV). Submeteu-se 10 cadáveres caninos à OIV. Nos antímeros esquerdos obteve-se a estabilização por meio de HIB (grupo HIB) e, nos direitos, com placas de compressão dinâmica (grupo placa). Foram comparados os ângulos de Norberg e de inclinação da cabeça e colo femoral (ICF) antes (T0) e após (T1) a OIV. O tempo dispendido para a colocação dos implantes e resultados de resistência biomecânica à compressão e torção também foram confrontados entre os grupos. Houve aumento do ângulo de Norberg entre T0 (106,84®5,55o) e T1 (111,22o®3,89), apenas no grupo HIB (p<0,05). No entanto, redução do ângulo de ICF após OIV (T1) foi observada tanto no grupo placa (T0=127,6®4,70o e T1=110,06®10,61o, p<0,05) quanto no grupo HIB (T0=126,43®5,87o e T1=116,87®8,62o, p<0,05). Os tempos de colocação dos implantes não diferiram estatisticamente e apenas o teste biomecânico de compressão revelou diferença entre os grupos, com maior resistência (P=0,033) do grupo placa (863,3®74,46N/mm) em relação ao grupo HIB (586,7®44,10N/mm). Deste modo, a estabilização por meio de HIB foi factível e eficaz. Embora o resultado biomecânico de compressão tenha demonstrado maior fragilidade da HIB em relação à placa de compressão, seus valores estão acima das forças atuantes, reportadas na literatura, na deambulação normal de cão.(AU)


Considering the advantages of the interlocking intramedullary nail (IN) in relation to bone plates in the femoral stabilization, this study aimed to evaluate the feasibility and effectiveness of IN application post intertrochanteric varus osteotomy (IVO). For this purpose, 10 canines cadavers were used. On the left femurs, the fixation was obtained with IN (IN group) and rights fixed with dynamic compression plates and screws (plate group). Was compared the angles of Norberg and inclination of the head and femoral neck (IHF) before (T0) and after (T1) IVO. The results of time spent for placement of implants and biomechanical resistance to compression and torsion were also confronted between groups. There was an increase of the Norberg angle between T0 (106.84®5.55o) and T1 (111.22o®3.89), only in IN group (p<0.05). However, reduction of IHF angle after IVO (T1) was observed in both, the plate group (T0=127.6®4.70o e T1=110.06®10.61o, p<0.05) and IN group (T0=126.43®5.87o e T1=116.87® 8.62 o, p<0.05). The placement times of the implants did not differ statistically and only the compression biomechanical test revealed differences between groups, with greater resistance (P=0.033) of the plate group (863.3®74.46N/mm) compared to IN group (586.7®44.10N/mm). Thus, stabilization through IN was feasible and effective. Although the compression biomechanical results has demonstrated a higher fragility of IN in relation to the compression plate, their values are above the forces, reported in literature, acting in normal dog gait.(AU)


Assuntos
Animais , Cães , Osteotomia/veterinária , Próteses e Implantes/veterinária , Placas Ósseas/veterinária , Fixação Intramedular de Fraturas/veterinária , Displasia Pélvica Canina/terapia , Fraturas do Quadril/veterinária , Procedimentos Ortopédicos/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA