1.
Acta Vet. Brasilica ; 16(4): 323-328, 2022. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1432539

RESUMO

One dog, Golden Retriever, 5 months old, was seen complaining of lameness and pain in the left pelvic limb. Avulsion of the tibial crest was diagnosed by radiographic means, which was corrected with a tension band. The absence of postoperative radiographic monitoring and the non-removal of the apparatus led to the early closure of the cranial tibial physis with continuous flow growth, resulting in pain, functional loss of the limb after one year and at a 13.2º tibial plateau angle negative. The biomechanical alteration of the limb was corrected using the inverted TPLO technique, converting the angle of the tibial plateau to 5.3 positive, without a rockback evidenced in 30, 60, 90 days up to four months after the operation. The objective of this case report is to describe the surgical correction with the inverted TPLO technique in a case of angle of the negative tibial plateau secondary to not removing the tension band applied in avulsion of the growing tibial crest. After 120 days, the dog was presented fully recovery and weight-bearing without any complication.


Um cão, Golden Retriever, de 5 meses de idade, foi atendido com queixa de claudicação e dor em membro pélvico esquerdo. Diagnosticou-se por meio radiográfico a avulsão da crista da tíbia, a qual foi corrigida com banda de tensão. A ausência de acompanhamento radiográfico pós-operatório e a não retirada do aparato levou ao fechamento precoce da fise tibial cranial com crescimento contínuo da caudal, resultando em dor, perda funcional do membro após um ano e em um ângulo de platô tibial de 13,2º negativos. A alteração biomecânica do membro foi corrigida por meio da técnica de TPLO invertida, convertendo o ângulo do platô tibial em 5,3º positivos, sem rockback evidenciado em 30, 60, 90 dias até quatro meses de pós-operatório. O objetivo desse relato de caso é descrever a correção cirúrgica com a técnica de TPLO invertida em um caso de ângulo do platô tibial negativo secundário a não retirada de banda de tensão aplicada em avulsão da crista da tíbia em crescimento. Após 120 dias, o paciente apresentou recuperação total com adequado suporte do peso no membro, sem qualquer complicação.


Assuntos
Animais , Cães , Osteotomia/veterinária , Tíbia/lesões , Fratura Avulsão/veterinária , Fraturas do Planalto Tibial/cirurgia
2.
Vet. Zoot. ; 24(3): 509-514, set. 2017. ilus
Artigo em Inglês | VETINDEX | ID: vti-17863

RESUMO

This is a case report that describes a severe condition of exungulation with distal phalanx avulsion in a mare, Quarter Horse of nine years old, attended at the Veterinary Hospital (HCV) from the Santa Catarina State University (CAV/UDESC), Lages, SC, Brazil. The animal showed exungulation of the right hindlimb due to transportation trauma and presented with severe lameness. All radiographs demonstrated osteoproliferative reaction in the proximal and middle phalanges and absence of the distal phalanx and the alar cartilage and severe peripheral soft tissue swelling. Due to the extensive injury with severe involvement of the distal phalanx and poor prognosis euthanasia was recommended and performed.(AU)


Este é um relato de caso que descreve uma condição grave de exungulação com avulsão da falange distal em uma égua, Quarto de Milha, de nove anos de idade, atendida no Hospital Veterinário (HCV) da Universidade do Estado de Santa Catarina (CAV/UDESC), Lages, SC, Brasil. O animal apresentou exungulação no membro pélvico direito, decorrente de trauma durante o transporte, apresentando intensa claudicação. Nas radiografias obtidas observaram-se reação osteoproliferativa nas falanges proximal e média e ausência de grande parte da falange distal e da cartilagem alar e aumento de volume dos tecidos moles. Devido à extensa lesão com grave comprometimento da falange distal e prognóstico ruim, recomendou-se a eutanásia.(AU)


Assuntos
Animais , Feminino , Cavalos , Fratura Avulsão/veterinária , Casco e Garras/lesões
3.
Vet. zootec ; 24(3): 509-514, set. 2017. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1503448

RESUMO

This is a case report that describes a severe condition of exungulation with distal phalanx avulsion in a mare, Quarter Horse of nine years old, attended at the Veterinary Hospital (HCV) from the Santa Catarina State University (CAV/UDESC), Lages, SC, Brazil. The animal showed exungulation of the right hindlimb due to transportation trauma and presented with severe lameness. All radiographs demonstrated osteoproliferative reaction in the proximal and middle phalanges and absence of the distal phalanx and the alar cartilage and severe peripheral soft tissue swelling. Due to the extensive injury with severe involvement of the distal phalanx and poor prognosis euthanasia was recommended and performed.


Este é um relato de caso que descreve uma condição grave de exungulação com avulsão da falange distal em uma égua, Quarto de Milha, de nove anos de idade, atendida no Hospital Veterinário (HCV) da Universidade do Estado de Santa Catarina (CAV/UDESC), Lages, SC, Brasil. O animal apresentou exungulação no membro pélvico direito, decorrente de trauma durante o transporte, apresentando intensa claudicação. Nas radiografias obtidas observaram-se reação osteoproliferativa nas falanges proximal e média e ausência de grande parte da falange distal e da cartilagem alar e aumento de volume dos tecidos moles. Devido à extensa lesão com grave comprometimento da falange distal e prognóstico ruim, recomendou-se a eutanásia.


Assuntos
Feminino , Animais , Casco e Garras/lesões , Cavalos , Fratura Avulsão/veterinária