Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Rev. habanera cienc. méd ; 16(2): 177-188, mar.-abr. 2017.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-845273

RESUMO

Introducción: Durante el crecimiento y desarrollo del niño pueden aparecer desarmonías esqueletales a nivel del macizo cráneo-facial. Entre estas se encuentra el Síndrome de Clase ll División 1, siendo el avance mandibular una de las alternativas para su corrección. Con este fin el Dr. Bimler diseñó un aparato que permite una mejor adaptación del paciente. Objetivo: Describir las modificaciones cefalométricas esqueletales que se producen con el uso del Modelador Elástico, en el tratamiento del Síndrome de Clase II División 1. Material y Método: Se realizó un estudio observacional, descriptivo y retrospectivo, el universo quedó constituido por 33 Historias Clínicas de pacientes que presentaban esta maloclusión y que fueron tratados con el Modelador Elástico Tipo A. Resultados: El ángulo total del Perfil disminuyó su promedio inicial de 14.6 a 11.8 mm y la Profundidad Facial aumentó en 4,3 mm. La Profundidad maxilar aumentó en 3,2mm; la Diagonal de Mandíbula y la Altura Facial Suborbital en 11.1mm y 4, 3 mm respectivamente, mientras el resalte esquelético se redujo en 1.6 mm. El 80 poe ciento de los varones y 72.3 por ciento de las hembras habían transformado su perfil a recto. Conclusiones: Con el uso del Modelador Elástico Tipo A en el tratamiento del Síndrome de Clase II División 1 las variables cefalométricas muestran cambios favorables hacia la corrección de las desarmonías esqueletales, al producirse unareducción significativa del resalte esquelético, lo cual contribuye a que el perfil de los pacientes sea más ortognático(AU)


Introduction: During children’s growth and development, disharmonies may occur at the level of facial-skull. Among these is Class II Division 1 Syndrome, being mandibular progress one of the alternatives for its correction. With this aim, Dr. Bimler designed a device that allows a better adaptation of the patient. Objective: Describe the skeletal cephalometric changes that occur with the use of the Elastic Modeling, in the treatment of Class II Division 1 Syndrome. Materials and Methods: An observational, descriptive and retrospective study were carried out, the work universe was made from 33 clinical records, all of them belong to patient with this anaraxia, treated with Bimler appliance Type A. Results: The total profile angle diminished its initial average from 14.6 to 11.8 mm., the maxillary depth increased in 3,2mm; the Jaw Diagonal and the Suborbital Facial Height increased too in 11.1mm and 4, 3 mm respectively, whereas the skeletal ledge decreased in 1.6 mm. 80 percent of the males and 72.3 percent of the females had transformed their profile to straight. Conclusions: With the use of Elastic Modeler Type A in the treatment of Class II Division 1 Syndrome, cephalometric variables show favorable changes towards the correction of skeletal disharmonies, resulting in a significant reduction of the skeletal ledge, which contributes to the more orthognathic profile of patients(AU)


Assuntos
Humanos , Masculino , Feminino , Fios Ortodônticos/normas , Aparelhos Ortodônticos Funcionais/normas , Anormalidades Craniofaciais/terapia , Epidemiologia Descritiva , Estudos Retrospectivos , Estudo Observacional
2.
Braz Oral Res ; 282014.
Artigo em Inglês | MEDLINE | ID: mdl-25166770

RESUMO

Manufacturers offer various prescriptions of preadjusted brackets for use in the "straight-wire" orthodontic technique. However, the need to incorporate bends in the rectangular wires during orthodontic finishing has led to concerns regarding the type of prescription chosen and the credibility of information provided by the manufacturer. The aim of this study was to compare the slot angulations of Roth prescription preadjusted metallic brackets for the maxillary left central incisor and maxillary left canine. For each tooth type, 10 brackets of three commercial brands (GAC, Forestadent and Morelli) were selected. Two individual metal matrices for brackets and tooth positioning were made for each group of teeth. Captured images were obtained by standardized ortho-radial photography with a digital camera. Images were exported and analyzed with the Image J software package. One-way ANOVA and Tukey statistical analyses were performed at the 5% significance level. For brackets of the maxillary left central incisor, differences in mean angulation were observed between the Morelli and GAC groups (p < 0.01) and between the Forestadent and GAC groups (p < 0.01). For brackets of the maxillary left canine, differences in mean angulation were found between the Morelli and GAC groups (p < 0.01) and between the Morelli and Forestadent groups (p < 0.05). In conclusion, despite their same prescription name, the different brands exhibited significantly different angulation measurements.


Assuntos
Desenho de Aparelho Ortodôntico/métodos , Braquetes Ortodônticos/normas , Fios Ortodônticos/normas , Análise de Variância , Coroas , Dente Canino , Incisivo , Teste de Materiais , Valores de Referência
3.
Braz Oral Res ; 21(2): 140-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17589649

RESUMO

The present study compared forces in stainless steel, TiMolium and TMA, V-bend intrusion arches with different magnitudes of flexion. The sample consisted of rectangular-section wires, caliber .017" x .025", with ten arches of each alloy. All V-bends were made 48 mm from the midline, using the same phantom upper jaw, maintaining the same distance between the tubes fixed to the molars and the midline. Loads necessary to deflect the arches by 5, 10, 15 and 20 mm were measured by means of an Instron dynamometer with a 1 kgf load cell. Calculations for sample size confirmed the suitability of using 10 arches of each alloy. Variance tests (ANOVA) of one factor and three levels, complemented by the Tukey test for multiple comparisons, identified that TMA(R) intrusion arches required a smaller quantity of load in relation to conventional steel and TiMolium at all levels of flexion. Furthermore, TiMolium presented intermediary characteristics between steel and TMA, and in all alloys increase in distance entailed a significant increase in force between all registered values, and that the increase in load necessary to deflect the arches at the intervals tended to decrease from first to last interval, these differences being more significant in steel, less in TiMolium and practically non-existent in TMA.


Assuntos
Ligas Dentárias/normas , Análise do Estresse Dentário , Braquetes Ortodônticos/normas , Fios Ortodônticos/normas , Aço Inoxidável/normas , Análise de Variância , Fenômenos Biomecânicos , Teste de Materiais , Técnicas de Movimentação Dentária
4.
Braz Oral Res ; 21(1): 51-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17384855

RESUMO

This in vitro study was designed to compare the forces generated by commercially available elastomeric chains and NiTi closed coil springs, and to determine their force decay pattern. Forty elastomeric chains and forty NiTi closed coil springs were divided into 4 groups according to the following manufacturers: (1) Morelli, (2) Abzil, (3) TP Orthodontics and (4) American Orthodontics. The specimens were extended to twice their original length and stored in artificial saliva at 37 degrees C. Initial force was measured by means of an Instron universal testing machine and then at 1, 4, 7, 14, 21, and 28 days. The results revealed that the elastomeric chains delivered a mean initial force of 347 g for Morelli, 351 g for American Orthodontics, 402 g for Abzil, and 404 g for TP Orthodontics. The NiTi closed coil springs generated a mean initial force of 196 g for American Orthodontics, 208 g for TP Orthodontics, 216 g for Abzil, and 223 g for Morelli. The mean percentage of force decay observed after 28 days for the elastomeric chains was 37.4% for TP Orthodontics(R), 48.1% for American Orthodontics, 65.4% for Morelli, and 71.6% for Abzil. After 28 days, the NiTi closed coil springs presented a mean percentage of force decay of 22.6% for American Orthodontics, 29.8% for Abzil, 30.6% for Morelli, and 45.8% for TP Orthodontics. At the end of the study, significant differences were observed between the elastomeric chains and the NiTi closed coil springs. The results indicated that the studied NiTi closed coil springs are more adequate for dental movement than the elastomeric chains.


Assuntos
Ligas Dentárias/química , Níquel/normas , Desenho de Aparelho Ortodôntico , Fios Ortodônticos/normas , Polímeros/normas , Titânio/normas , Análise de Variância , Temperatura Corporal , Elasticidade , Elastômeros , Níquel/química , Aço Inoxidável/química , Estresse Mecânico , Resistência à Tração , Titânio/química
5.
Braz. oral res ; 21(1): 51-57, Jan.-Mar. 2007. ilus, tab
Artigo em Inglês | LILACS | ID: lil-444562

RESUMO

This in vitro study was designed to compare the forces generated by commercially available elastomeric chains and NiTi closed coil springs, and to determine their force decay pattern. Forty elastomeric chains and forty NiTi closed coil springs were divided into 4 groups according to the following manufacturers: (1) Morelli®, (2) Abzil®, (3) TP Orthodontics® and (4) American Orthodontics®. The specimens were extended to twice their original length and stored in artificial saliva at 37°C. Initial force was measured by means of an Instron universal testing machine and then at 1, 4, 7, 14, 21, and 28 days. The results revealed that the elastomeric chains delivered a mean initial force of 347 g for Morelli®, 351 g for American Orthodontics®, 402 g for Abzil®, and 404 g for TP Orthodontics®. The NiTi closed coil springs generated a mean initial force of 196 g for American Orthodontics®, 208 g for TP Orthodontics®, 216 g for Abzil®, and 223 g for Morelli®. The mean percentage of force decay observed after 28 days for the elastomeric chains was 37.4 percent for TP Orthodontics®, 48.1 percent for American Orthodontics®, 65.4 percent for Morelli®, and 71.6 percent for Abzil®. After 28 days, the NiTi closed coil springs presented a mean percentage of force decay of 22.6 percent for American Orthodontics®, 29.8 percent for Abzil®, 30.6 percent for Morelli®, and 45.8 percent for TP Orthodontics®. At the end of the study, significant differences were observed between the elastomeric chains and the NiTi closed coil springs. The results indicated that the studied NiTi closed coil springs are more adequate for dental movement than the elastomeric chains.


Este estudo in vitro foi delineado para comparar a força gerada por cadeias elastoméricas e por molas fechadas de NiTi comercialmente disponíveis e para determinar seu padrão de degradação de forças. Para tal, 40 segmentos de cadeia elastomérica e 40 molas fechadas de NiTi foram divididas em 4 grupos de acordo com a marca comercial: (1) Morelli®, (2) Abzil®, (3) TP Orthodontics® e (4) American Orthodontics®. As amostras foram distendidas ao dobro de seu comprimento original e imersas em solução de saliva artificial a 37°C. Uma máquina de ensaio (Instron) foi utilizada para aferir a força inicial e em 1, 4, 7, 14, 21 e 28 dias. Os resultados mostraram que as cadeias elastoméricas liberaram uma força média inicial de 404 g para a marca TP Orthodontics®, 402 g para Abzil®, 351 g para American Orthodontics® e 347 g para Morelli®. As molas fechadas de NiTi geraram uma força média inicial de 223 g para a marca Morelli®, 216 g para Abzil®, 208 g para TP Orthodontics® e 196 g para American Orthodontics®. A percentagem média de degradação da força após 28 dias para as cadeias elastoméricas foi de 37,4 por cento para TP Orthodontics®, 48,1 por cento para American Orthodontics®, 65,4 por cento para Morelli® e 71,6 por cento para Abzil®. A percentagem média de degradação da força após 28 dias para as molas fechadas de NiTi foi de 22,6 por cento para American Orthodontics®, 29,8 por cento para Abzil®, 30,6 por cento para Morelli® e 45,8 por cento para TP Orthodontics®. Ao final do experimento, observaram-se diferenças significantes entre as cadeias elastoméricas e as molas fechadas de NiTi. Os resultados permitem recomendar as molas fechadas de NiTi estudadas como dispositivos mais adequados para movimentação dentária do que as cadeias elastoméricas.


Assuntos
Ligas Dentárias/química , Níquel/normas , Desenho de Aparelho Ortodôntico , Fios Ortodônticos/normas , Polímeros/normas , Titânio/normas , Análise de Variância , Temperatura Corporal , Elasticidade , Níquel/química , Estresse Mecânico , Aço Inoxidável/química , Resistência à Tração , Titânio/química
6.
Braz. oral res ; 21(2): 140-145, 2007. tab, ilus
Artigo em Inglês | LILACS | ID: lil-453193

RESUMO

The present study compared forces in stainless steel, TiMolium® and TMA®, V-bend intrusion arches with different magnitudes of flexion. The sample consisted of rectangular-section wires, caliber .017" x .025", with ten arches of each alloy. All V-bends were made 48 mm from the midline, using the same phantom upper jaw, maintaining the same distance between the tubes fixed to the molars and the midline. Loads necessary to deflect the arches by 5, 10, 15 and 20 mm were measured by means of an Instron dynamometer with a 1 kgf load cell. Calculations for sample size confirmed the suitability of using 10 arches of each alloy. Variance tests (ANOVA) of one factor and three levels, complemented by the Tukey test for multiple comparisons, identified that TMA® intrusion arches required a smaller quantity of load in relation to conventional steel and TiMolium® at all levels of flexion. Furthermore, TiMolium® presented intermediary characteristics between steel and TMA®, and in all alloys increase in distance entailed a significant increase in force between all registered values, and that the increase in load necessary to deflect the arches at the intervals tended to decrease from first to last interval, these differences being more significant in steel, less in TiMolium® and practically non-existent in TMA®.


O presente estudo comparou as forças em arcos de intrusão com dobra V confeccionados em aço inoxidável, TiMolium® e TMA®, com diferentes magnitudes de deflexão. A amostra constou de fios de secção retangular e calibre 0,017" x 0,025", com dez arcos de cada liga. Todas as dobras em V foram confeccionadas a 48 mm distantes da linha média, e foi utilizado o mesmo manequim de maxila para manter a mesma distância entre os tubos fixados nos molares e a linha média. As cargas necessárias para defletir os arcos em 5, 10, 15 e 20 mm foram mensuradas por meio de dinamômetro com célula de carga de 1 kgf, da marca Instron. O cálculo para o tamanho de amostra confirmou a possibilidade de se utilizar dez arcos de cada liga. Os testes de variância (ANOVA) de um fator e três níveis, complementados com os testes de Tukey para comparações múltiplas, identificaram que os arcos de intrusão de TMA® requereram menor quantidade de carga em relação ao aço convencional e ao TiMolium® em todos os níveis de deflexão; que o TiMolium® apresentou características intermediárias entre o aço e o TMA®; que em todas as ligas o aumento das distâncias implicou em aumento significativo da força entre todos os valores registrados; e que os incrementos de carga necessários para defletir os arcos nos intervalos tenderam a decrescer do primeiro ao último intervalo, sendo essas diferenças mais significantes no aço, menores no TiMolium® e praticamente inexistentes no TMA®.


Assuntos
Análise do Estresse Dentário , Ligas Dentárias/normas , Braquetes Ortodônticos/normas , Fios Ortodônticos/normas , Aço Inoxidável/normas , Análise de Variância , Fenômenos Biomecânicos , Teste de Materiais , Técnicas de Movimentação Dentária
7.
In. Dotto, Carlos Alberto; Antoniazzi, Joäo Humberto. Opinion makers: ortodontia e ortopedia facial. Säo Paulo, VM Comunicaçöes, 2002. p.48-52, ilus. (BR).
Monografia em Português | LILACS, BBO - Odontologia | ID: lil-312649
16.
Rev. Ateneo Argent. Odontol ; 35(1): 28-34, dic. 1995-jun. 1996. ilus, tab
Artigo em Espanhol | BINACIS | ID: bin-21517

RESUMO

Se han presentado dos casos clínicos similares, uno tratado con extracciones y otro conservando todas sus piezas dentarias. Se utilizó un mismo recurso biomecánico (el arco de Isaacson). Los resultados son rápidos y satisfactorios en ambos casos. La ventaja que ofrece esta técnica es que no requiere que el paciente colabore en la colocación propia de la aparatología, disminuye el tiempo y aumenta la efectividad en los resultados. (Es condición ineludible seguir paso a paso la técnica) (AU)


Assuntos
Humanos , Feminino , Adolescente , Adulto , Má Oclusão/terapia , Aparelhos Ortodônticos/normas , Ortodontia Corretiva/métodos , Radiografia Panorâmica , Extração Dentária , Técnicas de Movimentação Dentária/métodos , Fios Ortodônticos/normas
17.
Rev. Ateneo Argent. Odontol ; 35(1): 28-34, dic. 1995-jun. 1996. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-183134

RESUMO

Se han presentado dos casos clínicos similares, uno tratado con extracciones y otro conservando todas sus piezas dentarias. Se utilizó un mismo recurso biomecánico (el arco de Isaacson). Los resultados son rápidos y satisfactorios en ambos casos. La ventaja que ofrece esta técnica es que no requiere que el paciente colabore en la colocación propia de la aparatología, disminuye el tiempo y aumenta la efectividad en los resultados. (Es condición ineludible seguir paso a paso la técnica)


Assuntos
Humanos , Feminino , Adolescente , Adulto , Aparelhos Ortodônticos/normas , Má Oclusão/terapia , Ortodontia Corretiva , Extração Dentária , Fios Ortodônticos/normas , Radiografia Panorâmica , Técnicas de Movimentação Dentária
18.
In. Ferreira, Flavio Vellini. Ortodontia: diagnóstico e planejamento clínico. Säo Paulo, Artes Médicas, 1996. p.354-90, ilus.
Monografia em Português | LILACS, BBO - Odontologia | ID: lil-168128
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA