Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz. J. Pharm. Sci. (Online) ; 59: e20314, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1447570

RESUMO

Abstract Betamethasone (BET) is a synthetic glucocorticoid recommended for pregnant women at imminent risk of preterm birth before 34 weeks to reduce neonatal complications. There are different techniques to describe BET plasma quantification. However, none quantified the plasmatic concentration of BET in dichorionic (DC) twin pregnancies using LC-MS. Our objectives were to develop and validate a method for quantifying BET by LC-MS for pharmacokinetic (PK) and placental transfer studies in DC twin pregnancies. Blood samples were collected after intramuscular administration of a single BET dose containing 6 mg disodium phosphate + 6 mg acetate. BET was determined in plasma by liquid-liquid extraction. The method showed linearity in the range of 2-250 ng/mL, as well as precision and accuracy with a coefficient of variation and relative standard errors ≤ 15%. Additionally, the method presented selectivity and did not present matrix or carry-over effect. Stability tests also presented coefficient of variation and relative standard errors ≤ 15%. This is the first study which describe maternal and fetal plasma concentrations of BET in a DC twin pregnancy. The BET PK parameters were AUC0-∞, CL/F, Vd/F, Cmax, Tmax of 292.20 h*ng/mL, 39.08 L/h, 278.72 L, 25.55 ng/mL and 0.58 h, respectively. The placental transfer ratios of umbilical vein/maternal vein and intervillous space/maternal vein were 0.14 and 0.19 and 0.40 and 0.27 for both twins, respectively. However, a clinical study with more subjects is imperative to confirm this higher concentration of BET in the intervillous space


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Plasma/metabolismo , Betametasona/antagonistas & inibidores , Extração Líquido-Líquido/instrumentação
2.
Artigo em Inglês | MEDLINE | ID: mdl-29960251

RESUMO

In this paper, the use of disposable pipette extraction (DPX) for the determination of pesticides in human urine in possible cases of poisoning is proposed for the first time. The pesticides studied were oxamyl, propoxur, carbofuran, 3­hydroxycarbofuran, carbaryl, methiocarb, terbufos, parathion methyl, malathion, chlorpyrifos and endosulfan. The pipette tip used for the extraction of these compounds was commercially acquired. It has a capacity of 5 mL and contains 20 mg of sorbent material (styrene-divinylbenzene). The optimization of the main parameters that can influence the extraction efficiency of this sample preparation technique was performed with univariate and multivariate approaches. The analytes were separated and identified by gas chromatography coupled to mass spectrometry (GC-MS). The optimal extraction conditions were 5 extraction cycles of 30 s and 5 desorption cycles of 15 s with 250 µL of ethyl acetate. Elution of the extract was performed in a vial containing 100 mg of anhydrous sodium sulfate. The method developed was validated, providing correlation coefficients higher than 0.9955 for all analytes, limits of detection (LOD) of 0.76 to 1.52 µg L-1, limits of quantification (LOQ) of 2.5 to 5.0 µg L-1, relative recoveries of 63 to 118%, intra-day precision of 0.7 to 15.3% and inter-day precision of 4.9 to 13.1%. An effective and rapid method for the analysis of human urine for the identification of possible cases of poisoning by pesticides was successful developed.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Extração Líquido-Líquido/métodos , Resíduos de Praguicidas/urina , Adulto , Ensaios de Triagem em Larga Escala , Humanos , Limite de Detecção , Modelos Lineares , Extração Líquido-Líquido/instrumentação , Reprodutibilidade dos Testes , Adulto Jovem
3.
Biotechnol J ; 11(5): 708-16, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26848821

RESUMO

Aqueous two-phase systems (ATPS) are a liquid-liquid extraction technology with clear process benefits; however, its lack of industrial embracement is still a challenge to overcome. Antibodies are a potential product to be recovered by ATPS in a commercial context. The objective of this work is to present a more integral approach of the different isolated strategies that have arisen in order to enable a practical, generic implementation of ATPS, using human immunoglobulin G (IgG) as experimental model. A microfluidic device is used for ATPS parameters preselection for product recovery. ATPS were continuously operated in a mixer-settler device in one stage, multistage and multistage with recirculation configuration. Single-stage pure IgG extraction with a polyethylene glycol (PEG) 3350-phophates ATPS within continuous operation allowed a 65% recovery. Further implementation of a multistage platform promoted a higher particle partitioning reaching a 90% recovery. The processing of IgG from a cell supernatant culture harvest in a multistage system with top phase recirculation resulted in 78% IgG recovery in bottom phase. This work conjugates three not widely spread methodologies for ATPS: microfluidics, continuous and multistage operation.


Assuntos
Imunoglobulina G/isolamento & purificação , Extração Líquido-Líquido/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Desenho de Equipamento , Humanos , Polietilenoglicóis/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA