Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Semina ciênc. agrar ; 41(1): 7-32, Jan.-Feb. 2020. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1501724

RESUMO

The use of renewable energy is growing every year as an alternative to fossil fuel technology. Solar energy presents itself as a good alternative due to its great availability and energy potential. Solar thermal energy uses heat to warm fluids, and can also generate electricity, as well as being used in industrial processes and water desalination. The research and use of Parabolic Trough Collectors (PTCs) has been growing in recent years due to their ability to heat fluids at high temperatures in a relatively small area. In this work, two small PTCs were manufactured and tests were performed to improve the arrangements in order to increase the absorbed energy to reach temperature values for water disinfestation, aiming at the control of phytopathogens to control soil pathogens in small and medium farms. To control the automatic tracker, a low-cost system with Arduino, Light Dependent Resistors (LDRs) and step motors was used. The tracking times intervals analyzed were 1, 5 and 15 minutes. For the 1-minute tracking interval, the PTCs presented a thermal efficiency of 25.87%, with temperatures between 45 and 70 C and an average of 63.73 C. For the 5-minute tracking interval, the thermal efficiency was 18.48%, reaching temperatures between 41 and 68 ºC and an average of 57.9 ºC. For the 15-minute tracking interval, the PTCs presented a thermal efficiency of 14.80%, with temperatures between 39 and 62 °C and an average of 51.88 °C. The results showed that the tracking intervals of 1 and 5 minutes present more values between the lethal temperature range of 45 and 60 °C for phytopathogens. For agricultural application, the usage of a tracking interval of 5 minutes could be a good option for reducing the waste of system energy compared to the interval of 1 minute.


O uso de energia renovável está crescendo a cada ano como alternativa à tecnologia de combustíveis fósseis. A energia solar apresenta-se como uma boa alternativa devido à sua grande disponibilidade e potencial energético. A energia solar térmica utiliza o calor para aquecer os fluidos e também pode gerar eletricidade, bem como ser usada em processos industriais e dessalinização da água. A pesquisa e o uso de Coletores Solares Parabólicos (PTCs) têm crescido nos últimos anos devido à capacidade de aquecer fluidos em altas temperaturas em uma área relativamente pequena. Neste trabalho, dois pequenos PTCs foram fabricados, e testes foram realizados para melhorar os arranjos, a fim de aumentar a energia absorvida para atingir valores de temperatura para desinfestação de água, visando o controle de fitopatógenos no controle de patógenos de solo em pequenas e médias fazendas. Para controlar o rastreador automático foi utilizado um sistema de baixo custo com Arduino, Resistores de Potência Luminosa (LDRs) e motores de passo. Os intervalos de tempo de rastreamento analisados foram de 1, 5 e 15 minutos. Para o intervalo de rastreamento de 1 minuto, os PTCs apresentaram uma eficiência térmica de 25,87%, com temperaturas entre 45 e 70 ºC e 63,73 ºC de temperatura média. Para o intervalo de rastreamento de 5 minutos, a eficiência térmica foi de 18,48%, atingindo temperaturas entre 41 e 68 ° C e 57,9 ° C de temperatura média. Para o intervalo de rastreamento de 15 minutos, os PTCs apresentaram uma eficiência térmica de 14,80%, com temperaturas entre 39 e 62 ° C e 51,88 ° C de temperatura média. Os resultados mostraram que os intervalos de rastreamento de 1 e 5 minutos apresentam mais valores entre a faixa de temperatura letal de 45 e 60 ° C para fitopatógenos. Para aplicações agrícolas, o uso de um intervalo de rastreamento de 5 minutos poderia ser uma boa alternativa para uma redução no desperdício da energia do sistema em comparação com o intervalo de 1 minuto.


Assuntos
Coletores Solares/análise , Desinfetantes da Água/análise , Energia Solar
2.
Semina Ci. agr. ; 41(1): 7-32, Jan.-Feb. 2020. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: vti-746199

RESUMO

The use of renewable energy is growing every year as an alternative to fossil fuel technology. Solar energy presents itself as a good alternative due to its great availability and energy potential. Solar thermal energy uses heat to warm fluids, and can also generate electricity, as well as being used in industrial processes and water desalination. The research and use of Parabolic Trough Collectors (PTCs) has been growing in recent years due to their ability to heat fluids at high temperatures in a relatively small area. In this work, two small PTCs were manufactured and tests were performed to improve the arrangements in order to increase the absorbed energy to reach temperature values for water disinfestation, aiming at the control of phytopathogens to control soil pathogens in small and medium farms. To control the automatic tracker, a low-cost system with Arduino, Light Dependent Resistors (LDRs) and step motors was used. The tracking times intervals analyzed were 1, 5 and 15 minutes. For the 1-minute tracking interval, the PTCs presented a thermal efficiency of 25.87%, with temperatures between 45 and 70 C and an average of 63.73 C. For the 5-minute tracking interval, the thermal efficiency was 18.48%, reaching temperatures between 41 and 68 ºC and an average of 57.9 ºC. For the 15-minute tracking interval, the PTCs presented a thermal efficiency of 14.80%, with temperatures between 39 and 62 °C and an average of 51.88 °C. The results showed that the tracking intervals of 1 and 5 minutes present more values between the lethal temperature range of 45 and 60 °C for phytopathogens. For agricultural application, the usage of a tracking interval of 5 minutes could be a good option for reducing the waste of system energy compared to the interval of 1 minute.(AU)


O uso de energia renovável está crescendo a cada ano como alternativa à tecnologia de combustíveis fósseis. A energia solar apresenta-se como uma boa alternativa devido à sua grande disponibilidade e potencial energético. A energia solar térmica utiliza o calor para aquecer os fluidos e também pode gerar eletricidade, bem como ser usada em processos industriais e dessalinização da água. A pesquisa e o uso de Coletores Solares Parabólicos (PTCs) têm crescido nos últimos anos devido à capacidade de aquecer fluidos em altas temperaturas em uma área relativamente pequena. Neste trabalho, dois pequenos PTCs foram fabricados, e testes foram realizados para melhorar os arranjos, a fim de aumentar a energia absorvida para atingir valores de temperatura para desinfestação de água, visando o controle de fitopatógenos no controle de patógenos de solo em pequenas e médias fazendas. Para controlar o rastreador automático foi utilizado um sistema de baixo custo com Arduino, Resistores de Potência Luminosa (LDRs) e motores de passo. Os intervalos de tempo de rastreamento analisados foram de 1, 5 e 15 minutos. Para o intervalo de rastreamento de 1 minuto, os PTCs apresentaram uma eficiência térmica de 25,87%, com temperaturas entre 45 e 70 ºC e 63,73 ºC de temperatura média. Para o intervalo de rastreamento de 5 minutos, a eficiência térmica foi de 18,48%, atingindo temperaturas entre 41 e 68 ° C e 57,9 ° C de temperatura média. Para o intervalo de rastreamento de 15 minutos, os PTCs apresentaram uma eficiência térmica de 14,80%, com temperaturas entre 39 e 62 ° C e 51,88 ° C de temperatura média. Os resultados mostraram que os intervalos de rastreamento de 1 e 5 minutos apresentam mais valores entre a faixa de temperatura letal de 45 e 60 ° C para fitopatógenos. Para aplicações agrícolas, o uso de um intervalo de rastreamento de 5 minutos poderia ser uma boa alternativa para uma redução no desperdício da energia do sistema em comparação com o intervalo de 1 minuto.(AU)


Assuntos
Coletores Solares/análise , Desinfetantes da Água/análise , Energia Solar
3.
R. bras. Ci. Vet. ; 23(3-4): 133-137, jul./dez. 2016. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-686465

RESUMO

This study evaluated the microbiological quality of the water of 33 poultry sheds seeking to identify the presence of biofilm-producing Escherichia coli. The swab samples of the surface of the drinkers were analyzed by the inhibition test to detect the most effective disinfectant for removing these bacterial communities. The multiple-tube and mesophilic counts techniques were used to analyze the water samples. The swabs were plated on EMB agar followed by Rugai medium to identify E. coli. The biofilm was detected by the optical density readings and the Congo red agar method. Overall, 15 strains of Escherichia coli were detected in the swabs of the drinkers, of which 8 were biofilm producers. Regarding the water quality, 15 (45.45%) of the 33 evaluated water samples had bacterial growth while only two (13.33%) produced gas. The test with disinfectants showed that chlorine and chlorhexidine were not effective to control the E. coli biofilm production. Therefore, a strict control is essential to ensure the safety of the water supplied to the animals in broiler sheds and to eliminate the biofilm-forming E. coli that have shown to be potentially resistant to the sanitizers commonly used in the cleaning processes.(AU)


Objetivou-se avaliar a qualidade microbiológica da água de 33 galpões avícolas, identificar a presença de Escherichia coli produtoras de biofilmes em amostras de suabes de superfície dos bebedouros e analisar por teste de inibição o desinfetante mais eficiente para remoção dessas comunidades bacterianas. Foi utilizada a técnica dos tubos múltiplos e contagem de mesófilas para as amostras de água. Os suabes foram semeados em Ágar EMB, e posteriormente em meio Rugai para identificação de E. coli. Para análise de produção de biofilme foi feita a leitura da Densidade Óptica e o método do Ágar Vermelho Congo. Foram identificadas 15 cepas de E. coli nos suabes de bebedouros, sendo que 8 foram produtoras de biofilme. Quanto ao padrão de qualidade da água, observou-se que das 33 amostras de água avaliadas, 15 (45,45%) tiveram crescimento bacteriano, sendo que somente duas (13,33%) produziram gás. Para o teste com desinfetantes, o cloro e o clorexidine não se mostraram eficientes no controle da produção de biofilmes de E. coli. Dessa forma, torna-se essencial o controle rigoroso nos galpões de frangos de corte para garantir a inocuidade da água fornecida aos animais e a eliminação de E. coli potencialmente formadoras de biofilmes resistentes aos sanitizantes mais comumente usados nos processos de limpeza.(AU)


Assuntos
Animais , Escherichia coli , Galinhas/microbiologia , Desinfecção da Água/métodos , Desinfetantes da Água/análise , Biofilmes , Aves Domésticas/microbiologia , Técnicas Microbiológicas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA