Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 18(12)2018 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-30544689

RESUMO

This paper presents non-contact vital sign monitoring in neonates, based on image processing, where a standard color camera captures the plethysmographic signal and the heart and breathing rates are processed and estimated online. It is important that the measurements are taken in a non-invasive manner, which is imperceptible to the patient. Currently, many methods have been proposed for non-contact measurement. However, to the best of the authors' knowledge, it has not been possible to identify methods with low computational costs and a high tolerance to artifacts. With the aim of improving contactless measurement results, the proposed method based on the computer vision technique is enhanced to overcome the mentioned drawbacks. The camera is attached to an incubator in the Neonatal Intensive Care Unit and a single area in the neonate's diaphragm is monitored. Several factors are considered in the stages of image acquisition, as well as in the plethysmographic signal formation, pre-filtering and filtering. The pre-filter step uses numerical analysis techniques to reduce the signal offset. The proposed method decouples the breath rate from the frequency of sinus arrhythmia. This separation makes it possible to analyze independently any cardiac and respiratory dysrhythmias. Nine newborns were monitored with our proposed method. A Bland-Altman analysis of the data shows a close correlation of the heart rates measured with the two approaches (correlation coefficient of 0.94 for heart rate (HR) and 0.86 for breath rate (BR)) with an uncertainty of 4.2 bpm for HR and 4.9 for BR (k = 1). The comparison of our method and another non-contact method considered as a standard independent component analysis (ICA) showed lower central processing unit (CPU) usage for our method (75% less CPU usage).


Assuntos
Arritmia Sinusal/diagnóstico , Monitorização Fisiológica/métodos , Fotopletismografia/métodos , Arritmia Sinusal/diagnóstico por imagem , Arritmia Sinusal/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos , Recém-Nascido , Taxa Respiratória/fisiologia , Processamento de Sinais Assistido por Computador/instrumentação
2.
BMC Cardiovasc Disord ; 15: 7, 2015 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-25618133

RESUMO

BACKGROUND: Noncompaction cardiomyopathy (NCC) is a rare genetic cardiomyopathy characterized by a thin, compacted epicardial layer and an extensive noncompacted endocardial layer. The clinical manifestations of this disease include ventricular arrhythmia, heart failure, and systemic thromboembolism. CASE PRESENTATION: A 43-year-old male was anticoagulated by pulmonary thromboembolism for 1 year when he developed progressive dyspnea. Cardiovascular magnetic resonance imaging showed severe biventricular trabeculation with an ejection fraction of 15%, ratio of maximum noncompacted/compacted diastolic myocardial thickness of 3.2 and the presence of exuberant biventricular apical thrombus. CONCLUSION: Still under discussion is the issue of which patients and when they should be anticoagulated. It is generally recommended to those presenting ventricular systolic dysfunction, antecedent of systemic embolism, presence of cardiac thrombus and atrial fibrillation. In clinical practice the patients with NCC and ventricular dysfunction have been given oral anticoagulation, although there are no clinical trials showing the real safety and benefit of this treatment.


Assuntos
Arritmia Sinusal/etiologia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Trombose Coronária/etiologia , Embolia Pulmonar/etiologia , Disfunção Ventricular/etiologia , Adulto , Arritmia Sinusal/diagnóstico por imagem , Angiografia Coronária , Ecocardiografia , Coração/diagnóstico por imagem , Humanos , Angiografia por Ressonância Magnética , Masculino , Miocárdio/patologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA