Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J. bras. pneumol ; J. bras. pneumol;39(5): 547-554, Sep-Oct/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-695178

RESUMO

OBJECTIVE: To validate and develop an immunonephelometric assay for the determination of alpha-1 antitrypsin (AAT) levels in dried blood spots from COPD patients in Brazil. METHODS: We determined AAT levels in serum samples and dried blood spots from 192 COPD patients. For the preparation of dried blood spots, a disk (diameter, 6 mm) was placed into a tube, eluted with 200 µL of PBS, and stored overnight at 4ºC. All of the samples were analyzed by immunonephelometry in duplicate. We used the bootstrap resampling method in order to determine a cut-off point for AAT levels in dried blood spots. RESULTS: The correlation coefficient between the AAT levels in serum samples and those in dried blood spots was r = 0.45. For dried blood spots, the cut-off value was 2.02 mg/dL (97% CI: 1.45-2.64 mg/dL), with a sensitivity, specificity, positive predictive value, and negative predictive value of 100%, 95.7%, 27.2%, and 100%, respectively. CONCLUSIONS: This method for the determination of AAT levels in dried blood spots appears to be a reliable screening tool for patients with AAT deficiency. .


OBJETIVO: Validar e desenvolver um método de dosagem de alfa-1 antitripsina (AAT) por imunonefelometria em amostras de sangue em papel-filtro em pacientes com DPOC no Brasil. MÉTODOS: Amostras de soro e de sangue em papel-filtro de 192 pacientes com DPOC foram utilizadas para a dosagem de AAT. Para a preparação das amostras de sangue em papel-filtro, um disco do papel com diâmetro de 6 mm foi colocado em um tubo e eluído com 200 µL de PBS, permanecendo por toda a noite a 4ºC. Todas as amostras foram analisadas em duplicata por imunonefelometria. O método de reamostragem bootstrap foi utilizado para a determinação de um ponto de corte para o nível de AAT nas amostras de sangue em papel-filtro. RESULTADOS: O coeficiente de correlação entre os níveis de AAT em soro e em sangue em papel-filtro foi de r = 0,45. Para as amostras em papel-filtro, o ponto de corte foi de 2,02 mg/dL (IC97%: 1,45-2,64 mg/dL), com sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo de 100%, 95,7%, 27,2% e 100%, respectivamente. CONCLUSÕES: Este método de determinação dos níveis de AAT em sangue em papel-filtro se mostrou uma ferramenta confiável para o rastreamento de pacientes com deficiência de AAT. .


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Teste em Amostras de Sangue Seco/métodos , Testes Imunológicos/métodos , Nefelometria e Turbidimetria/métodos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Deficiência de alfa 1-Antitripsina/diagnóstico , alfa 1-Antitripsina/sangue , Brasil , Estudos Transversais , Programas de Rastreamento , Pacientes Ambulatoriais , Valor Preditivo dos Testes , Padrões de Referência
2.
Rev. bras. hematol. hemoter ; Rev. bras. hematol. hemoter;32(6): 463-468, 2010. graf, tab
Artigo em Português | LILACS | ID: lil-574796

RESUMO

INTRODUÇÃO: A hiperagregação (agregação excessiva) das plaquetas pode causar a formação de um trombo e a posterior oclusão dos vasos sanguíneos levando à isquemia. Esse fenômeno é responsável por doenças isquêmicas cardiovasculares, como angina pectoris e aterosclerose, bem como outras formas de isquemia, como o acidente vascular cerebral. Visando diminuir a função das plaquetas para reduzir a formação de trombos, o ácido acetilsalicílico vem sendo utilizado para tratamento antitrombótico, com diversos estudos mostrando sua eficácia. Dessa forma faz-se mister o uso de uma ferramenta laboratorial para o monitoramento da efetividade do tratamento, o que é feito por meio do teste de agregação plaquetária. O objetivo desse estudo foi comparar duas metodologias para esse exame (impedância elétrica e turbidimetria) em relação a trinta pacientes adultos de ambos os sexos em uso do fármaco. CONCLUSÃO: Os resultados mostraram uma boa correlação entre os métodos, possibilitando o uso concomitante de ambas as técnicas em laboratórios clínicos de rotina.


INTRODUCTION: Hyperaggregation of platelets can cause the formation of thrombi and subsequent occlusion of blood vessels leading to ischemia. This phenomenon can be responsible for ischemic cardiovascular diseases such as angina pectoris and atherosclerosis as well as other forms of ischemia such as stroke. To decrease platelet function and reduce the formation of thrombi, acetylsalicylic acid has been used for antithrombotic treatment, with several studies showing its effectiveness. Therefore it is necessary to use a laboratory tool to monitor the effectiveness of treatment, which is achieved through laboratory testing of platelet aggregation. The aim of this study was to compare two different methods (impedance and turbidimetry) to test platelet aggregation in 30 adult patients of both genders taking acetylsalicylic acid. CONCLUSION: The results show that there is a good correlation between these two methods and so both these techniques can be used in the clinical routine.


Assuntos
Humanos , Aspirina , Coagulação Sanguínea , Colágeno , Impedância Elétrica , Nefelometria e Turbidimetria , Agregação Plaquetária
3.
Ci. Rural ; 31(5)2001.
Artigo em Português | VETINDEX | ID: vti-703898

RESUMO

Fractal theoria application by determination of fractal dimension has been considered an alternative tool to explain the conformation of molecular aggregates. Its utilization in the study of humic substances (HS) aims the attempt to describe the limbed structure or the rugous and distorced surface of these substances. The presence of fractal models indicates that the system may be decomposed in parts, each part being a copy of the whole. In the experimental point of view the fractals models of natural systems may be measured through techniques as turbidimetry, x- ray and neutrons scattering. This paper seeks to facilitate the understanding on the application of the fractals in the conformational study of HS, supply information about fractal models foundation and use of the turbidimetry in the determination of fractal dimension.


A teoria fractal, por meio da determinação da dimensão fractal (D), tem sido considerada como uma alternativa para explicar a conformação de agregados moleculares. Sua utilização no estudo de substâncias húmicas (SH) reside na tentativa de descrever (representar) a estrutura ramificada ou a superfície rugosa e distorcida destas substâncias. A presença de um modelo fractal por sistemas naturais implica que este pode ser decomposto em partes, em que cada uma, subseqüentemente, é cópia do todo. Do ponto de vista experimental, a dimensão fractal de sistemas húmicos pode ser determinada a partir de técnicas como turbidimetria, raios x, espalhamento de neutrons, dentre outras. Este trabalho pretende facilitar o entendimento sobre a aplicação de fractais ao estudo conformacional de SH, introduzindo conceitos e informações sobre o fundamento dos modelos fractais, bem como sobre o uso da técnica turbidimétrica na determinação do valor D.

4.
Rev. cuba. pediatr ; 69(2): 124-128, Mayo-ago. 1997.
Artigo em Espanhol | LILACS | ID: lil-629580

RESUMO

Se realizó la adaptación al espectrofotómetro Shimadzu 160-A para cuantificar inmunoglobulinas (IgG, IgA e IgM) por el método turbidimétrico Fixed time para sistemas Hitachi. El control de calidad se realizó con productos de referencia nacionales e internacionales para precisión y exactitud. Los resultados de las medias (IgG = 12,31, IgA = 2,13 e IgM = 1,38) y desviaciones estándar (IgG = 0,3885, IgA = 0,155 e IgM = 0,129) muestran una dispersión pequeña, y aseguran la validez de nuestro trabajo. Con este estudio se abre la posibilidad de realizar dicha técnica mediante un método rápido y eficaz en un equipo mucho menos costoso que el Hitachi y ampliamente difundido en Cuba.


The fixed time turbidimetric procedure for Hitachi system was adapted to the spectrophotometer Shimadzu 160-A. The quality control was carried out with products of national and international reference to check precision and accuracy. The results of the means (IgG=12.31, IgA=2.13 and IgM = 1.38) and standard deviations (IgG=0.3885, IgA=0.155 and IgM=0.129) show a little dispersion and ensure the validity of our method. With this study, it is possible to put into practice this technique by a fast and efficient method in an equipment that is widely used in Cuba and much cheaper than the Hitachi.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA