Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pediatr ; 175: 228-230.e1, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27318382

RESUMO

Next-generation 3-Tesla magnetic resonance (MR) scanners offer improved neonatal neuroimaging, but the greater associated radiofrequency radiation may increase the risk of hyperthermia. Safety data for neonatal 3-T MR scanning are lacking. We measured rectal temperatures continuously in 25 neonates undergoing 3-T brain MR imaging and observed no significant hyperthermic threat.


Assuntos
Encéfalo/diagnóstico por imagem , Febre/etiologia , Imageamento por Ressonância Magnética/efeitos adversos , Neuroimagem/efeitos adversos , Febre/diagnóstico , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos , Termometria
2.
MAGMA ; 28(6): 599-608, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26449714

RESUMO

OBJECTIVE: A scaled-down slotted surface radio frequency (RF) coil was built, and the specific absorbance rate (SAR) in 100 mg of tissue (SAR100 mg) produced in a rat brain phantom was computed at 7 T. MATERIALS AND METHODS: A slotted coil 2-cm in diameter with six circular slots was developed. Its theoretical and experimental performance was computed and compared using the signal-to-noise ratio (SNR) expression and phantom images obtained with a spin echo sequence. Electromagnetic simulations were performed using the finite integral method with saline sphere and rat brain phantoms. SAR100 mg was computed for the circular coil, by varying its radius, and was also computed for the slotted coil. RESULTS: The slotted coil quality factor gave a twofold increment over the circular coil, and noise was reduced by 17%. The experimental SNR of the slotted coil produced a 30% improvement for points near the coil plane. The theoretical and experimental results showed substantial agreement. Axial map histograms and profiles showed greater SAR100 mg values for the circular coil than for the slotted coil. CONCLUSIONS: The slotted surface coil offers improved performance and low SAR100 mg for rat brain imaging at 7 T. This approach may be used with new RF coils to investigate SAR in humans.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Animais , Artefatos , Mapeamento Encefálico/métodos , Desenho de Equipamento , Modelos Estatísticos , Imagens de Fantasmas , Ratos , Ratos Wistar , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA