Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
J Prosthodont ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38812246

RESUMO

PURPOSE: To evaluate in situ the influence of sweat, oil, sunscreen, and disinfectant solution on the color stability, hardness, and roughness of elastomer for facial prostheses. MATERIALS AND METHODS: Standardized and intrinsically pigmented specimens remained in contact with human skin from the same person for 30 days, considering exposures (n = 36 per group), absent of exposition (Control, C); sweat and oiliness contact (SO); sweat and oiliness associated with sunscreen (SOS); 0.12% chlorhexidine digluconate immersion (CD0.12%); and all agents exposed (SOSCD). The main variables were color change (CIELab and National Standard Bureau system, NBS), Shore A hardness, and surface roughness, measured at baseline and 30 days. Qualitative analyses were performed by atomic force microscopy (AFM) and scanning electron microscopy (SEM). The data were analyzed by Kruskal-Wallis tests (color) and two-way ANOVA (hardness and roughness) with Sidak post-test (α = 0.05). RESULTS: CD0.12% (1.54 ± 0.49) and SOSCD (2.10 ± 1.03) had similar effects and caused the smallest color changes, considered mild and noticeable (NBS), respectively. SOS promoted the greatest color change (6.99 ± 1.43, NBS: large) and hardness (17.97 ± 0.56); SOS promoted intermediate roughness (3.48 ± 1.05) between SOSCD (2.25 ± 0.53), and two similar groups: C (4.46 ± 0.95), and CD0.12% (4.39 ± 1.26). The qualitative analysis showed an irregular, dense, dry, and whitish layer on the surface of the specimens exposed to sunscreen, which was reduced when in contact with 0.12% chlorhexidine digluconate. CONCLUSIONS: Endogenous and exogenous factors are capable of altering elastomer properties. The 0.12% chlorhexidine digluconate minimized the changes caused by sweat, oil, and sunscreen.

2.
Rev. bras. cir. plást ; 38(4): 1-6, out.dez.2023. ilus
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1525453

RESUMO

Introdução: A mamoplastia de aumento é uma das cirurgias plásticas mais realizadas no mundo. Tendo em vista sua alta aplicabilidade, é fundamental conhecer os fatores de risco relacionados à incidência de complicações pós-operatórias a fim de reduzilas nesse tipo de procedimento. Método: Este estudo é retrospectivo feito por meio da análise dos prontuários de 76 pacientes que realizaram mamoplastia de aumento primária com implantes de silicone durante os meses de janeiro de 2018 a dezembro de 2020. Resultados: Observou-se que a presença de comorbidades aumentou a incidência de complicações pós-operatórias precoces (p<0,001), mas não de complicações pósoperatórias tardias (p=0,8). O maior tempo cirúrgico também aumentou a incidência de complicações pós-operatórias (p=0,005). Conclusão: A presença de comorbidades influencia diretamente na incidência de complicações pós-operatórias da mastoplastia de aumento e por esta razão deve-se realizar uma adequada compensação pré-operatória antes de submeter as pacientes a este procedimento cirúrgico.


Introduction: Breast augmentation is one of the most performed plastic surgeries in the world. Given its high applicability, it is essential to know the risk factors related to the incidence of postoperative complications to reduce them in this type of procedure. Method: This retrospective study analyzed the medical records of 76 patients who underwent primary breast augmentation with silicone implants from January 2018 to December 2020. Results: It was observed that the presence of comorbidities increased the incidence of early postoperative complications (p<0.001) but not of late postoperative complications (p=0.8). Longer surgical time also increased the incidence of postoperative complications (p=0.005). Conclusion: The presence of comorbidities directly influences the incidence of postoperative complications after breast augmentation, and for this reason, adequate preoperative compensation must be carried out before submitting patients to this surgical procedure.

3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;86(4): 330-336, July-Sep. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447371

RESUMO

ABSTRACT Purpose: To evaluate the efficacy of soft HydroCone silicone hydrogel contact lenses in patients with posterior microphthalmos. Methods: The charts of 13 patients with posterior microphthalmos (26 eyes) who were fitted with soft HydroCone silicone hydrogel contact lenses were reviewed retrospectively. All the patients underwent assessments of uncorrected and best spectacle-corrected visual acuity and cycloplegic refraction. They were fitted with contact lenses according to the parameter values obtained from the topographical analysis and best contact lens-corrected visual acuity measurement. Results: The spherical equivalents of the right and left eyes ranged from 10.00 to 19.25 diopters and from 11.00 to 21.5 diopters, respectively. The mean axial and posterior chamber lengths were shorter than those of the age-matched population. However, the mean values of the anterior segment parameters such as horizontal visible iris diameter, central anterior chamber depth, lens thickness, and central corneal thickness were in the normal range. The mean keratometric measurements revealed increased corneal curvature compared with that in the normal population. The mean best contact lens-corrected visual acuity was significantly higher than the mean best spectacle-corrected visual acuity for both eyes (p=0.045). Conclusion: HydroCone silicon soft contact lenses provided better visual acuity than spectacles in the patients with posterior microphthalmos in this study.


RESUMO Objetivo: Avaliar a eficácia das lentes de contato gelatinosas HydroCone, de hidrogel com silicone, em pacientes com microftalmia posterior. Métodos: Foram revisados retrospectivamente 26 olhos com microftalmia posterior, a partir dos prontuários de 13 pacientes que receberam lentes de contato gelatinosas HydroCone, de hidrogel com silicone. Todos os pacientes foram submetidos ao exame de acuidade visual não corrigida e com melhor correção por óculos e com refração cicloplégica. Todos os pacientes receberam lentes de contato de acordo com os parâmetros obtidos na análise topográfica e foi obtida a melhor acuidade visual corrigida com lentes de contato. Resultados: O equivalente esférico do olho direito variou de 10,00 a 19,25 dioptrias, e o do olho esquerdo de 11,00 a 21,5 dioptrias. Os comprimentos médios axiais e das câmaras posteriores foram menores do que para a população de mesma idade. No entanto, os valores médios dos parâmetros do segmento anterior, como o diâmetro horizontal visível da íris, a profundidade da câmara anterior central, a espessura da lente e a espessura central da córnea estavam dentro da faixa normal. Os valores médios da ceratometria revelaram curvatura corneana aumentada em relação à população normal. A média da melhor acuidade visual corrigida com lentes de contato foi significativamente maior que a média da melhor acuidade visual corrigida com óculos em ambos os olhos (p=0,045). Conclusão: As lentes de contato gelatinosas de silicone HydroCone proporcionam melhor acuidade visual que óculos em pacientes com microftalmia posterior.

4.
Rev. bras. cir. plást ; 38(2): 1-7, abr.jun.2023. ilus
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1443501

RESUMO

Adjuvant-induced autoimmune/inflammatory syndrome leads to capsular contracture and fibrosis from the oxidation that takes place in silicone. Anaplastic large cell lymphoma occurs through the development of a seroma, with the formation of a periprosthetic effusion, or through the infiltration of the condition itself. To analyze these conditions, a review of the literature was carried out on the symptoms and pathophysiology of the autoimmune/inflammatory syndrome induced by adjuvants and anaplastic large cell lymphoma, searched using the terms "ASIA breast silicone," "Lymphoma," "Adjuvants" "Immunologic" " Breast Implants" on the PubMed platform. Analyzing the data obtained, it was noted that the symptoms of the autoimmune/inflammatory syndrome induced by adjuvants are nonspecific, such as fatigue, myalgia, arthralgia, morning stiffness, and night sweats, and therefore need attention. Anaplastic large cell lymphoma presents with breast pain, periprosthetic effusion, and palpable mass, among other characteristics. Because of these aspects, it is concluded that a good investigation should be carried out when nonspecific symptoms appear, regardless of the time the surgery was performed since these complications can occur years later.


A síndrome autoimune/inflamatória induzida por adjuvantes leva à contratura capsular e fibrose pela oxidação que acontece no silicone. O linfoma anaplásico de grandes células ocorre através do desenvolvimento de um seroma, com a formação de derrame periprotético ou por uma infiltração da própria afecção. Para análise destes acometimentos, foi realizada uma revisão da literatura acerca da sintomatologia e fisiopatologia da síndrome autoimune/inflamatória induzida por adjuvantes e linfoma anaplásico de grandes células, pesquisada através dos termos "ASIA breast silicone" "Lymphoma" "Adjuvants" "Immunologic" "Breast Implants" na plataforma PubMed. Analisando os dados obtidos, notou-se que os sintomas da síndrome autoimune/inflamatória induzida por adjuvantes são inespecíficos, como fadiga, mialgia, artralgia, rigidez matinal e suores noturnos, e, portanto, necessitam de atenção. Já o linfoma anaplásico de grandes células se apresenta com dor mamária, derrame periprotético, massa palpável, dentre outras características. Em vista destes aspectos, conclui-se que uma boa investigação deve ser realizada ao surgirem sintomas inespecíficos, independentemente do tempo que a cirurgia foi realizada, uma vez que estas complicações podem ocorrer anos após a cirurgia.

5.
Rev. Col. Bras. Cir ; 50: e20233476, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422729

RESUMO

ABSTRACT Introduction: in videolaparoscopic surgery, movements are conducted from a twenty times magnified image of an indirect operative field. The video interface used assumes the need for depth perception using two dimensions instead of three. Objective: to evaluate the effectiveness of training to perform the laparoscopic knot in a silicone model, in 8-hour courses, and to analyze the correlation of learning outcomes with factors such as: sex, age, laterality, previous knowledge in endosuture and medical specialty. Material and Methods: in this prospective and randomized study, 56 students were evaluated, who took 8-hour courses, with groups of up to ten students. We used: a white box with camera, LCD screen and silicone piece. Four exercises were performed on the silicone mold: right hand, left hand, needle at 45° and back hand. Results: 56 students (mean age = 33.28 years). The female group, n=18, mean age 29.61 years, 17 right-handed and 1 left-handed. The male group, n=38, mean age 34.57 years, 35 right-handers, 1 left-handed and 2 ambidextrous. In both groups, no correlation was observed between the analyzes of well performed knots when correlated with the age or sex of the participants. Conclusion: laparoscopic knot training, in silicone molds, in 8 h courses, proved to be effective. Factors such as gender, age, laterality, previous knowledge in endosuture and medical specialty do not interfere with the learning results.


RESUMO Introdução: na cirurgia videolaparoscópica os movimentos são conduzidos a partir de uma imagem magnificada de vinte vezes de um campo operatório indireto. A interface de vídeo utilizada pressupõe a necessidade de percepção de profundidade utilizando duas dimensões ao invés de três. Objetivo: avaliar a eficácia do treinamento de execução do nó laparoscópico em modelo de silicone, em cursos de 8h, e analisar a correlação dos resultados de aprendizagem com fatores como: sexo, idade, lateralidade, conhecimentos prévios em endosutura e especialidade médica. Material e Métodos: Neste estudo, prospectivo e randomizado, foram avaliados 56 alunos, que realizaram cursos de 8h de duração, com turmas de até dez alunos. Foram utilizados: uma caixa branca com câmera, tela de LCD e peça de silicone. No molde de silicone foram executados quatro exercícios: mão direita, mão esquerda, agulha a 45° e back hand. Resultados: 56 alunos (média de idade = 33,28 anos). O grupo feminino, n=18, média de idade 29,61 anos, 17 destras e 1 canhota. O grupo masculino, n=38, média de idade 34,57 anos, 35 destros, 1 canhoto e 2 ambidestros. Em ambos grupos não foram observados nenhuma correlação entre as análises de nós bem executados quando correlacionados com a idade ou sexo dos participantes. Conclusão: o treinamento de nó laparoscópico, em moldes de silicone, em cursos de 8h de duração, mostrou-se eficaz. Fatores como sexo, idade, lateralidade, conhecimentos prévios em endosutura e especialidade médica, não interferem nos resultados do aprendizado.

6.
Artigo em Português | LILACS, BDENF - Enfermagem | ID: biblio-1442410

RESUMO

Objetivo: Identificar sinais e sintomas experienciados por mulheres com síndrome autoimune induzida por adjuvantes (ASIA) devido ao uso de prótese mamária e os tratamentos realizados. Método: Estudo de campo de abordagem qualitativa realizado por meio de entrevistas online utilizan-do-se a técnica bola de neve. Incluíram-se 13 participantes. Resultados: A partir da análise dos dados, foram elencadas quatro categorias: conhecimento acerca da síndrome; sinais e sintomas; tratamento; e cuidados e implicações de Enfermagem. Identificaram-se mais de 120 sinais e sintomas, e o explante foi mencionado como tratamento definitivo por todas as entrevistadas. Os sinais e sintomas apresentados pelas participantes vão ao encontro do que é descrito pela literatura. Conclusão: Antes da descoberta da doença, as participantes realizaram tratamento com foco no alívio dos sintomas. Após o diag-nóstico, todas as mulheres procederam com o explante


Objective: To identify signs and symptoms experienced by women with autoimmune/inflammatory syndrome induced by adjuvants (ASIA) due to the use of breast implants and the treatments performed. Method: Field study with a qualitative approach carried out through online interviews using the snowball technique. 13 participants were included. Results: Based on data analysis, four categories were listed: knowledge about the syndrome; signs and symptoms; treatment; and nursing care and implications. Over 120 signs and symptoms were identified, and the explant was mentioned as a defi-nitive treatment by all interviewees. The signs and symptoms presented by the participants are in line with what is described in the literature. Conclusion:Before discovering the disease, the participants underwent treatment focused on symptom relief. After diagnosis, all women proceeded with the explant.Keywords: Autoimmune diseases. Prothesis implantation. Breast implantation. Silicones. Perioperative nursing


Objetivo: Identificar los signos y síntomas experimentados por mujeres con síndrome autoinmune inducido por adyuvantes (ASIA) debido al uso de implantes mamarios y los tratamientos realizados. Método: Estudio de campo con enfoque cualitativo realizado a través de entrevistas en línea utilizando la técnica de bola de nieve. Se incluyeron 13 participantes. Resultados: Con base en el análisis de los datos, se enumeraron cuatro categorías: conocimiento sobre el síndrome; signos y síntomas; tratamiento; y cuidados e implicaciones de enfermería. Se identificaron más de 120 signos y sínto-mas, y todos los entrevistados mencionaron el explante como tratamiento definitivo. Los signos y síntomas presentados por los participantes están en línea con lo descrito en la literatura. Conclusión: Antes de descubrir la enfermedad, los participantes realizaban un tratamiento enfocado en el alivio de los síntomas. Después del diagnóstico, todas las mujeres procedieron al explante


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Doenças Autoimunes/etiologia , Adjuvantes Imunológicos/efeitos adversos , Implantes de Mama/efeitos adversos , Síndrome , Entrevistas como Assunto , Pesquisa Qualitativa
7.
Clin Anat ; 35(5): 679-681, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35442548

RESUMO

Recently, there has been an increase in surgeries to treat silicones implant complications. These procedures are generally related to diseased fibrous capsules, with capsular contracture the most common clinical manifestation. However, patients often do not undergo a magnetic resonance imaging (MRI) scan for the explant surgical programming to access the fibrous capsule status and avoid residual diseased tissue. The accuracy of MRI to assess fibrous capsule breast neoplasm remnants depends on the surgical time. The ideal time for the evaluation is up to 72 h after the surgery when the repaired tissue starts to appear. Up to 2-3 weeks after surgery, MRI can provide information on the presence of a residual tumor. After this period, the presence of scar tissue and granuloma impairs the analysis. This communication discusses the role of MRI in evaluating residual fibrous capsules in the postoperative period.


Assuntos
Implantes de Mama , Neoplasias da Mama , Implantes de Mama/efeitos adversos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Cápsulas , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Silicones
8.
Radiol Case Rep ; 17(4): 1261-1265, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35198089

RESUMO

We described a breast papillary lesion related to silicone breast implant exposure. The case report is in accordance with our initial publication, where we proposed that silicone particles may trigger a process of reverse morphogenesis in pericapsular tissue resulting in metaplasia of the epithelial cells. The relationship between breast metaplasia and silicone implants is still little discussed in the literature. Our current study is based on evidence obtained from the files of a patient with a six-year-old history of silicone breast implant, which resulted in a diagnosis of a papillary lesion after a percutaneous breast biopsy. Currently, the main complications related to implants reported in the literature are intra- and extra-capsular ruptures, capsular contracture, and the most severe, breast implant-associated anaplastic large cell lymphoma. However, another complication not yet widely accepted in the literature is breast implant illness, resulting from silicone induced granuloma of breast implant capsule. Many medical specialists are skeptical about silicone disease potential and argue the lack of scientific evidence to support its existence. We believe that presenting these findings and the appropriate discussion of the results should contribute to a better understanding of the pathologies related to breast implants. It is worth mentioning that the safety of breast implants must be questioned.

9.
J Oral Implantol ; 48(4): 307-311, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34091685

RESUMO

This paper reports on an infected silicone chin implant due to the nonideal placement of dental implants, in a female patient aged 67 years old. A patient unsatisfied with her facial profile had received a silicone chin implant 25 years ago and had recently undergone surgery for placement of dental implants in a region close to the silicone implant. The nonideal positioning of dental implants and close contact with the silicone implant led to the absence of osseointegration, with consequent mobility and infection of both. The mobile dental implants and silicone implant were removed. Imaging exams revealed other complications of the silicone implant as bone resorption and formation of a narrow bone layer around the inferior silicone implant border. Alloplastic implants are an option for the esthetic correction of chin deformities. Solid silicone is biocompatible and highly resistant to degradation, with minimal allergic reaction and risk of toxicity. However, several postoperative complications may arise, such as migration or displacement, extrusion, foreign body reaction, bone resorption, heterotopic bone formation, and infection. Precise imaging exams are critical for diagnosis and to indicate the best treatment plan.


Assuntos
Reabsorção Óssea , Implantes Dentários , Idoso , Queixo/cirurgia , Estética Dentária , Feminino , Humanos , Silicones
10.
Acta Biomater ; 121: 339-348, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33271355

RESUMO

Silicones (i.e. crosslinked poly(dimethylsiloxane), PDMS) are commonly used material for microfluidic device fabrication. Nonetheless, due to the uncontrollable absorption of small hydrophobic molecules (<1 kDa) into the bulk, its applicability to cell-based drug assays and sensing applications has been limited. Here, we demonstrate the use of substrates made of silicones bulk modified with a poly(ethylene oxide) silane amphiphile (PEO-SA) to reduce hydrophobic small molecule sequestration for cell-based assays. Modified silicone substrates were generated with concentrations of 2 wt.%, 9 wt.% and, 14 wt.% PEO-SA. Incorporation of PEO-SA into the silicone bulk was assessed by FTIR analysis in addition to water contact angle analysis to evaluate surface hydrophobicity. Cell toxicity, absorption of small hydrophobic drugs, and cell response to hydrophobic molecules were also evaluated. Results showed that the incorporation of the PEO-SA into the silicone led to a reduction in water contact angle from 114° to as low as 16° that was stable for at least three months. The modified silicones showed viability values above 85% for NIH-3T3, MCF7, MDA-MB-468, and MDA-MB-231 cell lines. A drug response assay using tamoxifen and the MCF7 cell line showed full recovery of cell toxicity response when exposed to PDMS modified with 9 wt.% or 14 wt.% PEO-SA compared to tissue culture plastic. Therefore, our study supports the use of PEO-SA at concentrations of 9 wt.% or higher for enhanced surface wettability and reduced absorption of small hydrophobic molecules in PDMS-based platforms.


Assuntos
Dimetilpolisiloxanos , Silicones , Interações Hidrofóbicas e Hidrofílicas , Polietilenoglicóis , Água , Molhabilidade
11.
Rev. bras. cir. plást ; 35(3): 358-362, jul.-sep. 2020. ilus
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1128083

RESUMO

O uso do silicone líquido industrial como material para modificação estética no contorno corporal é uma prática realizada de forma clandestina há cerca de 60 anos. Atualmente, a maioria dos relatos provém de países da Ásia e América do Sul e as vítimas são principalmente mulheres e transexuais. Devido ao grande número de casos com complicações, o uso do silicone industrial para fins estéticos nunca foi aprovado. Entretanto, continua a ser aplicado isoladamente ou associado a outros produtos, determinando graves complicações locais e sistêmicas. Relata-se um caso de óbito de paciente transexual após injeção de silicone industrial em coxas e glúteos.


The use of industrial liquid silicone as a material for aesthetic modification of body contour is a practice that has been carried out clandestine for about 60 years. Currently, most reports come from countries in Asia and South America, and the victims are mainly women and transsexuals. Due to the large number of cases with complications, the use of industrial silicone for aesthetic purposes has never been approved. However, it continues to be applied alone or associated with other products, determining severe local and systemic complications. We report a case of death of a transsexual patient after injecting industrial silicone in the thighs and buttocks.

12.
Aesthetic Plast Surg ; 44(5): 1423-1437, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32152711

RESUMO

The cosmetic use of devices like prostheses to increase breast volume is nothing new. It is calculated that millions of people have been exposed to silicone in several ways, including breast implants, and since 1964 there has been uncertainty regarding their safety. We did not find in the literature any studies that reported the appearance of a specific immunological disease in patients with silicone breast implants. Furthermore, there are also neither case-control studies nor reports of patients proving that symptoms of autoimmune/inflammatory syndrome induced by adjuvants (ASIA) occurred after the placement of silicone implants nor that the patients had pre-existing symptoms. Several studies link silicone to allergic reactions and the development of systemic autoimmune diseases; however, other studies deny this association. There are currently several theories about the effect of silicone on the body. One theory with greater acceptance proposes an adjuvant effect of silicone on the development of autoimmune diseases in genetically predisposed patients. However, the variety of symptoms occurring in patients who develop these pathologies leads to doubts about the relationship between the adjuvant effects of a silicone prosthesis may have with a specific autoimmune disease or a mix of these diseases. The lack of consensus on this topic obliges a full review of what has already been reported in the literature to integrate the knowledge and propose a focus for new research on this matter. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Implante Mamário , Implantes de Mama , Algoritmos , Implante Mamário/efeitos adversos , Implantes de Mama/efeitos adversos , Humanos , Desenho de Prótese , Silicones/efeitos adversos
13.
Rev. méd. Chile ; 147(10): 1315-1322, oct. 2019. graf
Artigo em Espanhol | LILACS | ID: biblio-1058599

RESUMO

Tridimensional printing is becoming relevant in medicine, specially in surgical and interventional specialties. We review the technical aspects and clinical application of airway tridimensional printing. Using this technique, simulation models for bronchoscopy and models for diagnostic and therapeutic procedures such as stent design, tracheal reconstruction and airway models can be created.


Assuntos
Humanos , Sistema Respiratório , Impressão Tridimensional , Modelos Anatômicos , Próteses e Implantes , Desenho de Prótese , Traqueia , Stents , Treinamento por Simulação
14.
Breast J ; 25(5): 932-937, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31155830

RESUMO

Although breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) is a rare disease, its incidence has been increasing. The aim of this study was to assess the risk of BIA-ALCL in women with breast implants. A systematic search was carried out in Pubmed, Scopus, ScienceDirect, LIVIVO, Cochrane Library, Google Scholar, and OpenGrey databases. The risk assessment of bias was based on the Newcastle-Ottawa Scale. The rarity of BIA-ALCL was a major limitation. Although we have found evidence of an increased risk of BIA-ALCL, further studies are needed to understand why some large samples did not present any case of the disease.


Assuntos
Implante Mamário/efeitos adversos , Implantes de Mama/efeitos adversos , Linfoma Anaplásico de Células Grandes/etiologia , Neoplasias da Mama/cirurgia , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Incidência , Medição de Risco
15.
Rev. Assoc. Med. Bras. (1992, Impr.) ; Rev. Assoc. Med. Bras. (1992, Impr.);64(7): 575-576, July 2018. graf
Artigo em Inglês | LILACS | ID: biblio-976835

RESUMO

SUMMARY Hypercalcemia associated with silicone-induced granuloma is a rare disease. Diagnosis can be tricky as it is established after ruling out other hypercalcemia-causing entities. In addition, management is customized depending on the patient's wishes and possible solutions. We present a male bodybuilder, in his thirties, with multiple silicone injections in his upper extremities, who developed hypercalcemia and urinary symptoms. Advanced laboratory tests ruled out various causes of hypercalcemia and CT imaging revealed nephrocalcinosis. A biopsy of the upper arm showed granulomatous tissue and inflammation. The patient necessitated two sessions of dialysis and corticosteroids were given to relieve symptoms and reverse laboratory abnormalities. Silicone-induced hypercalcemia should be on high alert because of the increasing trend of body contour enhancements with injections, implants and fillers. Treatment should be optimized depending on the patient's needs and condition.


RESUMO A hipercalcemia associada ao granuloma induzido por silicone é uma doença rara. O diagnóstico pode ser complicado, pois é estabelecido depois de eliminadas outras entidades que causam hipercalcemia. Além disso, o gerenciamento é personalizado, dependendo dos desejos do paciente e das possíveis soluções. Apresentamos um fisiculturista masculino, com trinta e poucos anos, múltiplas injeções de silicone nas extremidades superiores, que desenvolveu hipercalcemia e sintomas urinários. Testes laboratoriais avançados descartaram várias causas de hipercalcemia e a imagem da TC revelou nefrocalcinoses. Uma biópsia da parte superior mostrou tecido granulomatoso e inflamação. O paciente exigiu duas sessões de diálise e foram administrados corticosteroides para aliviar os sintomas e reverter as anormalidades laboratoriais. A hipercalcemia induzida por silicone deve estar em alerta elevado devido à crescente tendência de aprimoramentos do contorno corporal com injeções, implantes e enchimentos. O tratamento deve ser otimizado de acordo com as necessidades e condições do paciente.


Assuntos
Humanos , Masculino , Adulto , Silicones/efeitos adversos , Granuloma de Corpo Estranho/complicações , Hipercalcemia/etiologia , Levantamento de Peso , Biópsia , Injeções Intradérmicas , Granuloma de Corpo Estranho/patologia , Hipercalcemia/patologia
16.
Rev. odontol. Univ. Cid. São Paulo (Online) ; 30(2): 157-168, abr.-jun. 2018. tab.; ilus.; graf.
Artigo em Espanhol | LILACS, BBO - Odontologia | ID: biblio-966165

RESUMO

En prótesis fija la integridad marginal o perfección del margen es de suma importancia así como una impresión que copie perfectamente el terminado de la preparación ya que de esto depende la adaptabilidade de la prótesis que permita la supervivencia de la restauración y el mantenimiento de la salud periodontal en la boca del paciente. En este estudio se compara la capacidad de tres materiales de impresión (2 siliconas por adición y 1 poliéter) para copiar el margen cervical de la preparación mediante las técnicas de doble hilo y cofia de trasferencia. Se utilizaron 96 primeros molares inferiores izquierdos divididos en 6 grupos de 16 c/u se restauraron los dientes con ionómero de vidrio, resina o poste colado según fuera el caso, se prepararon los dientes con terminación en chamfer, el grupo 1: técnica de doble hilo con silicone por adición (Silicona 1), grupo 2: técnica de doble hilo con poliéter, grupo 3: técnica de cofia de transferência con silicona (Silicona 1), grupo 4: técnica de cofia de transferencia con poliéter, grupo 5: Técnica de doble hilo con silicona (Silicona 2), grupo 6: Técnica de cofia con silicona (Silicona 2). Posteriormente fueron observados en el estereomicroscopio para evaluar la cantidad de burbujas e irregularidades en el margen cervical según la escala de Jokstad. Donde la prueba estadística de Chi-cuadrada con un nivel de confianza de < 0.05 no mostró diferencia estadística significativa entre las técnicas de impresión de doble hilo y la de cofia de trasferencia, independientemente del material usado. Aunque numéricamente la técnica de doble hilo se comportó mejor que la técnica de cofia por lo que se sugiere su uso.


In fixed prosthesis, the integrity of perfection of the margin is of utmost importance, as well as an impression that perfectly copies the finish of the preparations, since the adaptability of the prosthesis that ensures survival of the restoration and periodontal health depends on this. This study compares the capacity of 3 different materials (2 silicones addition and 1 polyether) to copy the cervical margin of the preparation in the impression between the techniques of double cord and coping. We used 96 lower left molars divided into 6 groups of 16 each. The teeth were restored with glass ionomer, resin or cast post and core depending on the case, the margins were finished in a chamfer (group 1), double thread with addition silicone (group 2), double thread with polyether, (group 3), coping with PVS, (group 4), coping with polyether, (group5) double cord with PVS (group 6), coping With PVS. They were subsequently evaluated in a stereomicroscope to observe the number of bubbles and irregularities in the cervical margin according to the Jockstad scale, where the Chi-square test with a confidence level of <0.05 showed no statistically significant difference between impression techniques and coping regardless of material used. Although numerically the double-thread technique behaved better than coping technique, so it is suggested its use.


Assuntos
Silicones , Técnica de Moldagem Odontológica , Materiais para Moldagem Odontológica
17.
Rev Bras Ortop ; 53(2): 208-212, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29911088

RESUMO

OBJECTIVE: Evaluation of rheumatoid hand-associated metacarpophalangeal joint silicone arthroplasty most often relies on functional scores alone. This study aimed to understand the correlation between perceived and observed function, strength, and alignment. METHODS: Cross-sectional study including all 11 women (15 hands) submitted to second to fifth metacarpophalangeal joint arthroplasty due to rheumatoid arthritis involvement for a time period of seven years. Measurements relied on the Michigan Hand Outcomes Questionnaire, Lafayette Purdue Pegboard, pinch and grip strength, and analysis of a lateral "OK-sign" X-ray view. Correlation analysis used Spearman's coefficient, assuming statistical significance for p-values < 0.05. RESULTS: Objective function was strongly correlated with all other variables (p < 0.05), while perceived function failed to correlate with articular alignment in both measurements (p = 0.240 and p = 0.354). Strength and alignment were also strongly correlated (p < 0.05). CONCLUSIONS: Most measurements strongly correlate with each other, with emphasis on objective dexterity measurement.


OBJETIVO: Na maioria das vezes, a avaliação da artroplastia da articulação metacarpofalangeana com implante de silicone é feita apenas por meio de escores funcionais. Este estudo teve como objetivo compreender a correlação entre função, força e alinhamento percebidos e observados. MÉTODOS: Este estudo transversal incluiu todas as 11 mulheres (15 mãos) que foram submetidas a artroplastia metacarpofalangeana no segundo ao quinto dedo devido a artrite reumatoide em um período de sete anos. As medições basearam-se no Michigan Hand Outcomes Questionnaire, no Lafayette Purdue Pegboard e nas forças de pinça e preensão, além da análise de radiografia da mão em leque. O coeficiente de Spearman foi usado para avaliar a correlação; valores de p < 0,05 foram considerados estatisticamente significantes. RESULTADOS: A função objetiva foi fortemente correlacionada a todas as outras variáveis (p < 0,05). Por outro lado, a função percebida não foi correlacionada ao alinhamento articular em ambas as medições (p = 0,240 e p = 0,354). A força e o alinhamento também estiveram fortemente correlacionados (p < 0,05). CONCLUSÕES: A maioria das medições se correlacionou fortemente entre si, com ênfase na medição objetiva da destreza.

18.
Rev. Bras. Ortop. (Online) ; 53(2): 208-212, Mar.-Apr. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-899266

RESUMO

ABSTRACT Objective: Evaluation of rheumatoid hand-associated metacarpophalangeal joint silicone arthroplasty most often relies on functional scores alone. This study aimed to understand the correlation between perceived and observed function, strength, and alignment. Methods: Cross-sectional study including all 11 women (15 hands) submitted to second to fifth metacarpophalangeal joint arthroplasty due to rheumatoid arthritis involvement for a time period of seven years. Measurements relied on the Michigan Hand Outcomes Questionnaire, Lafayette Purdue Pegboard, pinch and grip strength, and analysis of a lateral "OK-sign" X-ray view. Correlation analysis used Spearman's coefficient, assuming statistical significance for p-values < 0.05. Results: Objective function was strongly correlated with all other variables (p < 0.05), while perceived function failed to correlate with articular alignment in both measurements (p = 0.240 and p = 0.354). Strength and alignment were also strongly correlated (p < 0.05). Conclusions: Most measurements strongly correlate with each other, with emphasis on objective dexterity measurement.


RESUMO Objetivo: Na maioria das vezes, a avaliação da artroplastia da articulação metacarpofalangeana com implante de silicone é feita apenas por meio de escores funcionais. Este estudo teve como objetivo compreender a correlação entre função, força e alinhamento percebidos e observados. Métodos: Este estudo transversal incluiu todas as 11 mulheres (15 mãos) submetidas à artroplastia metacarpofalangeana no segundo ao quinto dedo devido a artrite reumatoide em um período de sete anos. As medições basearam-se no Michigan Hand Outcomes Questionnaire, no Lafayette Purdue Pegboard e nas forças de pinça e preensão, além da análise de radiografia da mão em leque. O coeficiente de Spearman foi usado para avaliar a correlação; valores de p < 0,05 foram considerados estatisticamente significantes. Resultados: A função objetiva foi fortemente correlacionada a todas as outras variáveis (p < 0,05). Por outro lado, a função percebida não foi correlacionada ao alinhamento articular em ambas as medições (p = 0,240 e p = 0,354). A força e o alinhamento também estiveram fortemente correlacionados (p < 0,05). Conclusões: A maioria das medições se correlacionou fortemente entre si, com ênfase na medição objetiva da destreza.


Assuntos
Humanos , Feminino , Artrite Reumatoide , Artroplastia , Silicones , Força da Mão , Articulação Metacarpofalângica
19.
Biofouling ; 34(1): 15-25, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29258349

RESUMO

This study investigated the microbial colonization of maxillofacial prostheses and support tissues using the Checkerboard DNA-DNA hybridization method, and the efficacy of 0.12% chlorhexidine gluconate, 10% Ricinus communis solutions, or brushing, on colony forming unit (CFU) reduction in monospecies biofilms (Candida glabrata, Staphylococcus aureus, Streptococcus mutans, Escherichia coli, Enterococcus faecalis, and Pseudomonas aeruginosa) formed on two silicones (MDX 4-4210 and Bio-Skin). Biofilm was harvested from 43 maxillofacial prosthesis wearers for detection of 38 species of microorganisms. The CFU counts of the six above mentioned species were recorded after using the hygiene protocols. All 38 investigated species were identified in prostheses and tissues, with a higher prevalence in the prostheses. 0.12% chlorhexidine gluconate immersion showed the greatest antimicrobial effectiveness, followed by mechanical brushing protocols. MDX 4-4210 silicone produced lower CFU counts than Bio-Skin.


Assuntos
Anti-Infecciosos/farmacologia , Biofilmes/efeitos dos fármacos , Clorexidina/análogos & derivados , Prótese Maxilofacial/microbiologia , Consórcios Microbianos/genética , Extratos Vegetais/farmacologia , Escovação Dentária , Aderência Bacteriana/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Clorexidina/farmacologia , Contagem de Colônia Microbiana , Dimetilpolisiloxanos/química , Feminino , Genômica , Humanos , Masculino , Consórcios Microbianos/efeitos dos fármacos , Ricinus/química , Elastômeros de Silicone/química , Silicones/química , Propriedades de Superfície , Resultado do Tratamento
20.
Einstein (Säo Paulo) ; 15(4): 465-469, Oct.-Dec. 2017. tab
Artigo em Inglês | LILACS | ID: biblio-891424

RESUMO

ABSTRACT Objective: To analyze the quality and quantity of data in the questionnaires and in request forms for magnetic resonance imaging. Methods: This retrospective study was conducted with data from 300 medical records. The research used the following data from the questionnaires: patient age, reason for the magnetic resonance imaging, reason for placing the breast implant, report of any signs or symptoms, time elapsed since surgery to place the current breast implant, replacement implant surgery, chemotherapy, and/or radiation therapy treatments. From the magnetic resonance imaging request forms, information about the breast implant, the implant placement surgery, patient clinical information and ordering physician specialty were verified. Results: The mean age of patients was 48.8 years, and the mean time elapsed since breast implant surgery was 5 years. A total of 60% of women in the sample were submitted to aesthetic surgery, while 23.7% were submitted to chemotherapy and/or radiation therapy. In the request forms, 23.7% of physicians added some piece of information about the patient, whereas 2.3% of them informed the type of implant and 5.2% informed about the surgery. Conclusion: The amount of information in the magnetic resonance imaging request forms is very limited, and this may hinder quality of radiological reports. Institutional and technological measures should be implemented to encourage the requesting physicians and radiologists to share information.


RESUMO Objetivo: Analisar a qualidade e a quantidade de dados que constam nos questionários e nas requisições médicas de exame de ressonância magnética. Métodos: Estudo retrospectivo com 300 prontuários de pacientes. Dos questionários, foram utilizados os seguintes dados: idade, razão para a realização do exame, motivo para a colocação da prótese, referência a sinal ou sintoma, tempo decorrido desde a cirurgia de implante da prótese atual, se a cirurgia foi de troca da prótese, e se foi submetida à radioterapia ou à quimioterapia. Das requisições médicas do exame, foram utilizadas informações sobre prótese mamária, cirurgia de colocação do implante, dados clínico da paciente e especialidade do médico requisitante. Resultados: A média da idade das pacientes foi de 48,8 anos, e o tempo decorrido desde a colocação do implante foi de 5 anos, na média. Foram submetidas à cirurgia estética 60% das mulheres da amostra, e 23,7% tinham sido submetidas à quimioterapia e/ou radioterapia. Na requisição médica, 23,7% dos médicos inseriram algum dado, sendo que 2,3% informaram o tipo de implante e 5,2% sobre a cirurgia realizada. Conclusão: A quantidade de informações contidas nas requisições médicas foi baixa, o que pode comprometer a qualidade do laudo radiológico. Medidas institucionais e tecnológicas deveriam ser adotadas para estimular o intercâmbio de informações entre o médico solicitante e o médico radiologista.


Assuntos
Humanos , Feminino , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Encaminhamento e Consulta/estatística & dados numéricos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Inquéritos e Questionários , Implantes de Mama/efeitos adversos , Silicones/efeitos adversos , Fatores de Tempo , Prontuários Médicos/normas , Estudos Retrospectivos , Sistemas de Registro de Ordens Médicas , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA