Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Int Dent J ; 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38734514

RESUMO

AIM: The aim of this study was to compare the microtensile bond strength (µTBS) and failure mode of 4 different universal adhesive systems (UAs) on human dentin. MATERIALS AND METHODS: The study sectioned the occlusal thirds of 32 human third molars and divided them into 4 groups based on the adhesive system used. Group A: Palfique Universal Bond, Group B: Single Bond Universal, Group C: All-Bond Universal, and Group D: One Coat 7 Universal. The specimens underwent a 10,000-cycle thermocycling ageing process prior to testing (n = 32). Afterwards, 8 beams were obtained per group and subjected to µTBS testing using a digital universal testing machine at a speed of 1 mm/min. The microtensile bond strength values were analysed in Megapascals (MPa), and the failure mode was evaluated using a stereomicroscope. Welch's parametric ANOVA with robust variance and the Games-Howell post hoc test were used for µTBS comparisons, and Fisher's exact test was used to determine the association between adhesive type and failure mode. The significance level was set at P < .05. RESULTS: Group D showed a significantly higher µTBS than groups A (P < .001) and B (P < .001), but no significant difference was observed with group C (P= .075). Furthermore, groups B and C showed significantly higher µTBS than group A (P< .001 and P < .001, respectively), but there was no significant difference between groups B and C (P = .132). Additionally, group A exhibited a significant association with an adhesive failure mode (P < .05), whereas groups B, C, and D were significantly associated with a mixed failure mode (P < .05). CONCLUSION: The One Coat 7 Universal adhesive system showed higher microtensile bond strength values and higher chemical interaction with dentin compared to Palfique Universal Bond and Single Bond Universal. However, no significant differences were observed compared to All-Bond Universal.

2.
Dent Mater ; 39(12): 1159-1168, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37839995

RESUMO

OBJECTIVES: The aim of this double-blind, and randomized controlled clinical trial was to evaluate the 5-year clinical performance of posterior resin composite restorations placed with the incremental filling technique [IF] or the bulk-fill technique [BF]. Two different adhesive systems were used: etch-&-rinse (ER) or self-etch (SE). METHODS: Posterior dental teeth of 72 participants (n = 236), with a cavity depth of at least 3 mm, were randomly divided into four groups. Restorations were applied with either Tetric N-Bond or Tetric N-Bond SE. The composite resin Tetric N-Ceram Bulk-Fill was placed either with IF or BF. Restorations were evaluated using FDI criteria at baseline and after 1, 2, 3, 4, and 5 years. Statistical analysis was performed using the Wilcoxon Signed rank test (a=0.05). RESULTS: Two hundred and four restorations were evaluated after 5 years. Eleven restorations were considered 'failed', ten due to fracture (4 IF and 6 BF) and one due to secondary caries (IF). The annual failure rate was 1.2% for BF and 1% for IF (p = 0.35). When comparing BF and IF, no significant differences were found for any of the parameters evaluated (p > 0.05). Regarding the adhesive systems, 44 and 51 restorations showed minor problems in terms of marginal adaptation and staining, with significantly more marginal discoloration when the self-etch adhesive was used (p = 0.002). SIGNIFICANCE: The bulk-fill restorative technique showed good clinical behavior compared to the incremental filling technique, especially when using an etch-&-rinse adhesive, after 5 years of clinical evaluation.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Humanos , Restauração Dentária Permanente/métodos , Resinas Compostas/química , Método Duplo-Cego , Cimentos de Resina , Adaptação Marginal Dentária
3.
Odovtos (En línea) ; 24(3)dic. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1406159

RESUMO

Abstract: The purpose of this study was to compare the shear bond strength (SBS) of four resin-based composite materials to a silicate-based cement using a ''no-wait'' universal bond with self-etch (SE) and etch-and-rinse (ER) modes. Acrylic blocks (n=80, 2mm depth, 5mm diameter central hole) were prepared. The holes were filled with BiodentineTM (BD) and divided into 4 main groups (n=20) according to the composite resin type used: Group FZ250: FiltekTM Z250 Universal Restorative (microhybrid), Group SDR: SDR Plus U Bulk Fill Flowable (low-viscosity bulk-fill), Group FBP: FiltekTM Bulk Fill Posterior (high-viscosity bulk-fill), Group EF: EsFlow™ Universal Flowable Composite (nanohybrid). A 'no-wait' universal bond (Clearfil Universal Bond Quick) was used for bonding application. Then each group was divided into 2 subgroups according to the etching mode applied (ER and SE). SBSs were measured and stereomicroscope was used to identify the failure modes. Selected samples of fracture surfaces were imaged by SEM. Tukey's post-hoc and One-way ANOVA tests were used to analyze data. There were statistically significant differences among the composite groups (p 0.05). The SBS of BD to the resin composites depends on the composite type but application of the 'no-wait' universal bond in different etching modes is regardless of the SBS of BD to resin composites.


Resumen El objetivo de este estudio fue comparar la resistencia de adhesión al cizallamiento (SBS) de cuatro resinas con un cemento a base de silicato utilizando una adhesivo universal "no-wait" de autograbado (SE) y grabado y lavado (ER). Se prepararon bloques acrílicos (n=80, de 2mm de profundidad y un agujero central de 5mm de diámetro). Los agujeros se rellenaron con BiodentineTM (BD) y se dividieron en 4 grupos principales (n=20) según el tipo de resina compuesta utilizada: Grupo FZ250: FiltekTM Z250 Universal Restorative (microhíbrido), Grupo SDR: SDR Plus U Bulk Fill Flowable (bulk-fill de baja viscosidad), Grupo FBP: FiltekTM Bulk Fill Posterior (bulk-fill de alta viscosidad), Grupo EF: EsFlow™ Universal Flowable Composite (nanohíbrido). Para la aplicación de la adhesión se utilizó un adhesivo universal "no-wait" (Clearfil Universal Bond Quick). A continuación, cada grupo se dividió en 2 subgrupos según el modo de grabado aplicado (ER y SE). Se midieron los SBS y se utilizó el estereomicroscopio para identificar los modos de fallo. Las muestras seleccionadas de las superficies de fractura se analizaron mediante SEM. Se utilizaron las pruebas post-hoc de Tukey y ANOVA de una vía para analizar los datos. Hubo diferencias estadísticamente significativas entre los grupos de composites (p0,05). La SBS de la BD a los composites de resina depende del tipo de composite, pero la aplicación de la unión universal "no-wait" en los diferentes modos de grabado es independiente de la SBS de la BD a los composites de resina.


Assuntos
Humanos , Adesivos Dentinários , Resistência ao Cisalhamento , Turquia
4.
Clin Oral Investig ; 26(6): 4337-4350, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35142923

RESUMO

OBJECTIVES: To evaluate the influence of different application strategies on the clinical behavior of an MDP-free universal adhesive placed in non-carious cervical lesions (NCCLs) over the course of 36 months. MATERIALS AND METHODS: Thirty-one patients participated in this study (N = 31). One hundred twenty-four restorations were assigned to four groups: We used the self-etch strategy on groups with (SE-et) and without (SET) selective enamel etching, and the etch-and-rinse strategy on groups with dry (ER-D) and moist (ER-M) dentin. After applying the MDP-free universal adhesive (Xeno Select universal adhesive, Dentsply Sirona), cavities were filled using EvoluX composite resin (Dentsply Sirona). The restorations were evaluated at baseline and after 36 months according to World Dental Federation (FDI) and US Public Health Service (USPHS) criteria. Friedman's repeated-measures analysis of variance rank (α = 0.05) was used for statistical analysis. RESULTS: We evaluated the 31 patients after 36 months. Forty-two restorations were lost (ER-D = 5, ER-M = 7, SE-et = 14, SET = 16). The 36-month retention/fracture rates (95% confidence interval) were 83.9% for ER-D, 77.4% for ER-M, 54.9% for SE-et, and 48.4% for SET. ER strategy showed better retention rate than SE strategy (p < 0.05). Thirty-four restorations (ER-D = 6, ER-M = 10, SE-et = 10, SET = 8) showed marginal staining per FDI criteria and 15 restorations (ER-D = 1, ER-M = 2, SE-et = 6, SET = 6) showed marginal staining per USPHS criteria. No restorations showed postoperative sensitivity or recurrence of caries. CONCLUSION: The retention rate of Xeno Select universal adhesive was poor, mainly in the self-etch strategy. TRIAL REGISTRATION: REBEC clinical registry under protocol RBR-4wh4sh. CLINICAL RELEVANCE: MDP-free universal adhesive behavior depends on the bonding strategy used.


Assuntos
Colagem Dentária , Cárie Dentária , Resinas Compostas/uso terapêutico , Cimentos Dentários , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Adesivos Dentinários , Seguimentos , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Cimentos de Resina
5.
J Esthet Restor Dent ; 34(4): 689-698, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35138027

RESUMO

OBJECTIVES: To evaluate the influence of the sonic device on the clinical performance of one-step self-etch adhesive systems in non-carious cervical lesions (NCCLs) after 18 months. MATERIALS AND METHODS: Forty patients participated in this study. Eighty restorations were assigned to two groups (n = 40): Sonic application and Manual application. After the adhesive application (iBond Self-Etch, Kulzer, Hanau, Germany), NCCLs were restored using composite resin (Charisma, Kulzer, Hanau, Germany). The restorations were evaluated at baseline and after 18 months both according to the Word Dental Federation (FDI) and the United States Public Health Service (USPHS) criteria. Friedman repeated measures analysis of variance by rank and Wilcoxon test for significance in each pair were applied (α = 0.05). RESULTS: After 18 months, 38 patients were evaluated. Twenty-three restorations were lost (19 for manual vs. 4 for sonic application). The retention rates (95% confidence interval) were 50% (CI 34.8%-65.1%) for manual application and 84.2% (CI 69.6%-92.6%) for sonic application (p < 0.05). Twelve restorations showed marginal staining (nine for manual vs. three for sonic application; FDI, p < 0.05) and nine some marginal discrepancy (seven for manual vs. two for sonic application; FDI, p < 0.05). No restorations showed postoperative sensitivity and caries recurrence at the time. CONCLUSION: The sonic application increases the retention rate of iBond Self-Etch after 18 months of clinical evaluation in NCCLs. CLINICAL RELEVANCE: The application of a simplified self-etch adhesive (iBond Self-Etch) associated to a sonic device seems to be an alternative to improve the clinical behavior in NCCLs.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Resinas Compostas/química , Cárie Dentária/patologia , Cimentos Dentários , Adaptação Marginal Dentária , Adesivos Dentinários , Humanos , Cimentos de Resina , Colo do Dente/patologia
6.
Rev. Fac. Odontol. (B.Aires) ; 37(87): 25-33, 2022. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1537886

RESUMO

La Odontología Restauradora contemporánea no puede concebirse sin la adhesión de los materiales restauradores a las estructuras dentarias. En mu-chos procedimientos restauradores, no sólo el esmal-te sino también la dentina se encuentra involucrada, por lo tanto, la adhesión a esta última juega un rol cla-ve en el éxito clínico. No obstante, todavía supone un gran desafío lograr una adhesión estable y predeci-ble en el tiempo. El propósito del presente artículo es analizar las características principales de la dentina como sustrato adhesivo y describir los sistemas ad-hesivos actuales y sus mecanismos de acción (AU)


Contemporary Restorative Dentistry cannot be conceived without the adhesion of restorative materials to dental structures. In many restorative procedures not only the enamel, but also the dentin is involved, therefore dentin bonding plays a key role in their success. However, it is still a great challenge to achieve stable and predictable dentin bonding over time. The aim of this article is to analyze the main characteristics of dentin as an adhesive substrate and to describe current adhesive systems and their bonding mechanisms (AU)


Assuntos
Adesivos Dentinários/classificação , Dentina/efeitos dos fármacos , Dentina/ultraestrutura , Polímeros/classificação , Condicionamento Ácido do Dente/métodos , Desmineralização do Dente/fisiopatologia , Resinas Compostas/química , Metilmetacrilato/química , Restauração Dentária Permanente/tendências
7.
Braz. dent. j ; Braz. dent. j;32(5): 34-40, Sept.-Oct. 2021. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1350285

RESUMO

Abstract The aims of this in vivo study were to evaluate the effect of bonding with resin-modified glass ionomer cement (RMGIC) and to assess enamel surface roughness before and after the removal of brackets bonded with composite or RMGIC from the maxillary central incisors. Fifteen orthodontic patients were selected for the study. For each patient, the teeth were rinsed and dried, and brackets were bonded with composite (Transbond XT) and RMGIC (Vitremer Core Buildup/Restorative). At the conclusion of orthodontic treatment, their brackets were removed. Dental replicas were made of epoxy resin in initial conditions (before bonded) and after polishing with an aluminum oxide disc system. Adhesive remnant index (ARI) and surface roughness was measured on the dental replicas and data were evaluated statistically by Mann-Whitney and paired t-test, respectively. No bracket debonding occurred during patients' treatment periods. It was verified that the ARI values of the two maxillary central incisors were similar (p = 0.665). For both bonding materials, the ARI value of 3 was predominant. After polishing, surface roughness was similar in the composite and RMGIC groups (0.245 μm and 0.248 μm, respectively; p = 0.07). In both groups, enamel surface roughness values were significantly lower after polishing compared with the initial condition (p < 0.001). RMGIC promoted efficiency in cementing brackets without fail during treatment; the choice of composite or RMGIC materials was not a factor that influenced the roughness of the enamel surface, however, polishing led to smoother surfaces than those found at the beginning of the treatment.


Resumo Os objetivos deste estudo in vivo foram avaliar o efeito da colagem com cimento de ionômero de vidro modificado por resina (CIVMR) e a rugosidade da superfície do esmalte antes e após a remoção dos braquetes colados com compósito ou CIVMR em incisivos centrais superiores. Quinze pacientes ortodônticos foram selecionados para o estudo. Para cada paciente, os dentes foram lavados e secos, e os braquetes colados com compósito (Transbond XT) e CIVMR (Vitremer Core Buildup / Restorative). Ao término do tratamento ortodôntico, os braquetes foram removidos. As réplicas dentais foram confeccionadas em resina epóxica nas condições iniciais (antes da colagem) e após o polimento com sistema de discos de óxido de alumínio. O índice de remanescente adesivo (IRA) e a rugosidade da superfície foram mensurados nas réplicas dentais e os dados foram avaliados estatisticamente por Mann-Whitney e teste t pareado, respectivamente. Não ocorreu descolagem de braquetes durante os períodos de tratamento dos pacientes. Verificou-se que os valores do IRA dos dois incisivos centrais superiores foram semelhantes (p = 0,665). Para ambos os materiais de colagem, o valor de IRA predominante foi 3. Após o polimento, a rugosidade da superfície do esmalte foi semelhante nos grupos compósito (0,245 μm) e CIVMR (0,248 μm) (p = 0,07). Em ambos os grupos, os valores de rugosidade da superfície do esmalte foram significativamente menores após o polimento em comparação com a condição inicial (p <0,001). CIVMR promoveu eficiência na colagem de braquetes sem falhas durante o tratamento; a escolha dos materiais compósito ou CIVMR não foi um fator que influenciou na rugosidade da superfície do esmalte, porém, o polimento levou a superfícies mais lisas do que as encontradas no início do tratamento.

8.
Braz. dent. j ; Braz. dent. j;32(5): 96-104, Sept.-Oct. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1350291

RESUMO

Abstract The aim of this study was to evaluate the micro-shear bond strength (µSBS) of one and two steps self-etch adhesive systems after enamel bleaching with photo-activated bleaching systems of different hydrogen peroxide (HP) concentration. Occlusal enamel of forty intact human molars were flattened and assigned into four groups. GI Unbleached, GII, GIII, and GIV were bleached with Pyrenees (3.5% HP), GC TiON (20% HP), and Hi-Lite (35% HP) respectively. Enamel treatment with one and two steps self-etch adhesives (Clearfil S3 Bond- S3, and Clearfil SE Bond-SE) then micro-tubes were fixed on enamel and filled with AP-X composite (n=5). Bond was tested with the universal testing machine. Data were analyzed using two-way ANOVA and Tukey's tests at 5 % level of significance. The µSBS was significantly different between adhesives (F=154.46; p<0.05) and bleaching systems (F=77.33; p<0.05) with significant interaction. Specimens bonded with S3 shows a significantly lower μSBS than those bonded with SE (p<0.05) in all groups. For both adhesives the bleached groups demonstrate lower µSBS than unbleached except specimens bleached with Pyrenees and bonded with SE (p>0.05). A significant difference was observed between groups of the bleaching systems (p<0.05). Different peroxide concentrations photo-activated bleaching systems adversely affect μSBS of one and two steps self-etch adhesives. Low concentration system (Pyrenees) does not influence the bond strength of two steps adhesive.


Resumo O objetivo deste estudo foi avaliar a resistência ao cisalhamento (µSBS) de sistemas auto-adesivos de um e dois passos após clareamento do esmalte com sistemas de clareamento foto-ativados de diferentes concentrações de peróxido de hidrogênio (HP). O esmalte oclusal de quarenta molares humanos intactos foi aplainado e atribuído em quatro grupos. GI Unbleached, GII, GIII, e GIV foram branqueados com Pyrenees (3,5% HP), GC TiON (20% HP), e Hi-Lite (35% HP) respectivamente. Tratamento de esmalte com adesivos de um e dois passos auto-adesivos (Clearfil S3 Bond- S3, e Clearfil SE Bond-SE), depois os microtubos foram fixados no esmalte e preenchidos com composto AP-X (n=5). A resistência ao cisalhamento foi testada com a máquina universal de testes. Os dados foram analisados usando os testes de ANOVA e Tukey de duas vias a um nível de 5% de significância. O µSBS foi significativamente diferente entre adesivos (F=154,46; p<0,05) e sistemas de clareadores (F=77,33; p<0,05) com interação significativa. Os espécimes colados com S3 mostram um μSBS significativamente inferior aos colados com SE (p<0,05) em todos os grupos. Para ambos os adesivos, os grupos clareados demonstram µSBS inferiores aos não clareados exceto os espécimes clareados com Pyrenees e colados com SE (p>0,05). Foi observada uma diferença significativa entre os grupos dos sistemas de clareamento (p<0,05). Diferentes concentrações de peróxidos foto-ativados nos sistemas de clareamento afetam negativamente μSBS dos adesivos de uma e duas etapas de auto-colagem. O sistema de baixa concentração (Pyrenees) não influenciou a resistência ao cisalhamento do adesivo de duas etapas.

9.
Natal; s.n; 2021. 46 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1537201

RESUMO

Objetivo: Este estudo investigou a liberação de cálcio (CaR) e estabilidade de adesão à dentina em longo prazo (DBS) de sistemas adesivos autocondicionantes experimentais contendo hidróxido de cálcio. Metodologia: Quatro sistemas adesivos foram formulados incluindo monômeros UDMA, HEMA, GDMA-P, TPO e difenil iodônio como sistema fotoiniciador, e etanol / água como solvente com diferentes frações de massa de hidróxido de cálcio: 0% (controle), 1%, 2% e 4%. O DBS foi medido pelo método de microtração de resistência de união em máquina de ensaio de microtração. O terço médio da dentina de 24 terceiros molares humanos (n = 6) foi usado para unir os sistemas adesivos a uma resina composta. Amostras em forma de palitos (1 mm2 ) foram obtidas após 24 horas de imersão em água destilada e testadas imediatamente e após 12 meses de armazenamento em água. Os dados foram avaliados estatisticamente por meio de ANOVA de dois fatores e pós-teste de Tukey (p <0,05). O CaR foi avaliado por meio de espectrofotômetro. Os espécimes em discos (6,0 mm de diâmetro x 0,3 mm de espessura) foram produzidos (n = 4) e imersos em água destilada. A concentração de cálcio foi medida após 3 h até 168 h. Resultados: Para DBS, os sistemas adesivos contendo 0%, 1% e 4% de hidróxido de cálcio apresentaram médias estatisticamente semelhantes entre os pontos de tempo imediato (24h) e 12 meses. O sistema adesivo contendo 2% de hidróxido de cálcio apresentou resistência de união estatisticamente maior em 12 meses (p = 0,001). Nenhum material liberou cálcio até 168 h após a fotoativação. Conclusão: A inclusão de hidróxido de cálcio a 2% resultou na melhora da durabilidade de união à dentina a longo prazo. No entanto, a inclusão de hidróxido de cálcio aos sistemas adesivos experimentais testados não foi capaz de liberar cálcio (AU).


Objective: This study investigated the calcium release (CaR) and long-term dentin bonding stability (DBS) of experimental self-etching adhesive systems containing calcium hydroxide. Methodology: Four adhesive systems were formulated including UDMA, HEMA, GDMA-P, TPO and diphenyl iodonium monomers as photoinitiator system, and ethanol/water as solvent with different mass fractions of calcium hydroxide: 0% (control), 1%, 2% and 4%. DBS was measured by the microtensile bond strength method in a microtensile testing machine. The middle third of dentin from 24 human third molars (n = 6) was used to bond the adhesive systems to a composite resin. Stick-shaped samples (1 mm2) were obtained after 24 hours of immersion in distilled water and tested immediately and after 12 months of storage in water. Data were statistically evaluated using two-way ANOVA and Tukey's post-test (p < 0.05). CaR was evaluated using a spectrophotometer. Disc specimens (6.0 mm in diameter x 0.3 mm thick) were produced (n = 4) and immersed in distilled water. Calcium concentration was measured after 3 h to 168 h. Results: For DBS, adhesive systems containing 0%, 1% and 4% calcium hydroxide had statistically similar means between the immediate time points (24h) and 12 months. The adhesive system containing 2% calcium hydroxide had a statistically higher bond strength in 12 months (p = 0.001). No material released calcium up to 168 h after photoactivation. Conclusion: The inclusion of 2% calcium hydroxide resulted in improved long-term bond strength to dentin. However, the inclusion of calcium hydroxide in the experimental adhesive systems tested was not able to release calcium (AU).


Assuntos
Hidróxido de Cálcio/química , Adesivos Dentinários , Análise de Variância
10.
Dent Mater ; 36(11): 1474-1485, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32933775

RESUMO

OBJECTIVE: To evaluate the five-year clinical performance of Scotchbond Universal Adhesive (SU; 3M Oral Care, St. Paul, MN, USA) in non-carious cervical lesions (NCCLs) using two evaluation criteria. METHODS: Thirty-nine patients participated in this study. Two hundred restorations were assigned to four groups: SU-ERm: etch-and-rinse + moist dentin; SU-ERd: etch-and-rinse + dry dentin; SU-Set: selective enamel etching; and SU-SE: self-etch. A nanofilled composite resin was placed incrementally. The restorations were evaluated at baseline and after 5 years using both the World Dental Federation (FDI) and the United States Public Health Service (USPHS) criteria. The survival rates (retention/fractures) were calculated with the Kaplan-Meier and the log-rank test. For the secondary outcomes, Friedman repeated measures analysis of variance by rank was applied (α = 0.05). RESULTS: After 5 years the recall rate was 86%. The retention/fracture rates were 93% for Erm and ERd, 88.4% for SEet and 81.4% for SE. A significant difference was observed for SE vs. ERd and SE vs. ERm (p = 0.01). Also, marginal discoloration and adaptation showed significant differences with ERm and ERd resulting in fewer marginal discrepancies than SE (p < 0.05). SIGNIFICANCE: After 5 years, the clinical behavior of the universal adhesive in the etch-and-rinse strategy was better when compared to the self-etch strategy. The use of selective enamel etching is highly recommended for the self-etch strategy. The FDI and USPHS evaluation criteria showed similar results after 5 years.


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Cimentos Dentários , Adaptação Marginal Dentária , Falha de Restauração Dentária , Restauração Dentária Permanente , Humanos , Cimentos de Resina
11.
Rev. odontol. UNESP (Online) ; 48: e20190083, 2019. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1043176

RESUMO

Abstract Introduction Modern dentistry is reflected in the insertion of new materials with different adhesion forms in dental structures, such as the Universal adhesive system. Objective To evaluate the bond strength of the universal dentin adhesive system, in the form of self-etching and conventional application, compared with a simplified conventional adhesive system, in two distinct periods: 1 week and 6 months. Material and method 48 bovine incisors separated into 6 groups, stored for 7 days, were selected. Worn out the buccal enamel until dentin exposure. Adper Single Bond 2 (3M Espe) or SingleBond Universal (3M Espe) adhesives were applied, and catheters filled with Opallis Flow (FGM) composite were placed. After photoactivation, the catheters were removed and the specimens (n ​​= 48), stored in distilled water at 37 °C for one week and six months, were exposed. The specimens were fixed to a universal testing machine (EMIC DL 2000) with a speed of 0.5 mm / min. Bond strength (BS) was calculated in MPa, and data were statistically analyzed by Anova and Tukey test at 5% significance level. Result For Adper Single bond, the BS was equivalent in the times tested; for Universal conventional and self-conditioning time influenced the BS, with a decrease in the results. At 1 week, all stickers were different from each other, with higher BS for Universal conventional mode, followed by universal self-etching mode and then Adper Single bond. Conclusion The best results were achieved with universal adhesive in conventional mode for both tested times.


Resumo Introdução A odontologia moderna é refletida na inserção de novos materiais com diferentes formas de adesão nas estruturas dentárias, como o sistema adesivo Universal. Objetivo Avaliar a resistência adesiva do sistema adesivo universal em dentina, na forma de aplicação auto condicionante e convencional, comparando com um sistema adesivo convencional simplificado, em dois períodos distintos: 1 semana e 6 meses. Material e método Foram selecionados 48 incisivos bovinos separados em 6 grupos, armazenados por 7 dias. Desgastado o esmalte vestibular, até exposição da dentina. Aplicaram-se os adesivos Adper Single Bond 2 (3M Espe) ou SingleBond Universal (3M Espe), e sobre este, posicionados cateteres preenchidos com o compósito Opallis Flow (FGM). Após fotoativação, removeram-se os cateteres e expuseram-se os corpos de prova (n=48), armazenados em água destilada a 37 °C por uma semana e seis meses. Os corpos de prova foram fixados uma máquina universal de ensaios (EMIC DL 2000), com velocidade de 0,5 mm/min. A resistência de união (RU) foi calculada em MPa, e os dados foram analisados estatisticamente pela Anova e pelo teste de Tukey ao nível de 5% de significância. Resultado Para Adper Single bond, a RU foi equivalente nos tempos testados; para Universal modo convencional e autocondicionante o tempo influenciou na RU, havendo um decréscimo nos resultados. Em 1 semana, todos os adesivos foram diferentes entre si, com maior RU para Universal modo convencional, seguido por universal modo autocondicionante e então pelo Adper Single bond. Conclusão O melhor desempenho foi do adesivo universal na forma convencional nos dois tempos testados.


Assuntos
Cimentos Dentários , Materiais Dentários , Métodos , Resistência ao Cisalhamento , Dentina
12.
Microsc Res Tech ; 80(8): 943-949, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28488772

RESUMO

AIM: Evaluate the composite-to-enamel bond after passive or active application of self-etching primer systems on polished or pre-etched enamel with phosphoric acid. MATERIALS AND METHODS: Two self-etch adhesives systems (SEAS) were used: Clearfil SE Bond and Easy Bond. Third human molars were divided into 8 groups (N = 10). The crown of each tooth was sectioned into halves and the mesial/distal surfaces were used. The adhesives were actively or passively applied on enamel with or without prior phosphoric-acid etching. Resin composite cylinders were built after adhesive application. After stored in relative humidity for 24 hr/37°C the specimens were subjected to microshear test in universal testing a machine at a crosshead speed of 0.5 mm/minute. The results were analyzed with three-way ANOVA and the Tukey test. The enamel-etching pattern was evaluated under SEM. RESULTS: The 2-step SEAS system presented significantly higher adhesive bond strength means (47.37 MPa) than the 1-step (36.87 MPa). A poor enamel- etching pattern was observed in active mode showing irregular and short resin tags, however there was not compromised the bond strength. CONCLUSION: Active or passive application produced similar values of bond strength to enamel regardless of enamel pretreatment and type of SEAS.

13.
Dental press j. orthod. (Impr.) ; 22(1): 47-56, Jan.-Feb. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-840212

RESUMO

ABSTRACT Objective: To evaluate the effect of silica dioxide (SiO2) nanofillers in different bonding systems on shear bond strength (SBS) and mode of failure of orthodontic brackets at two experimental times. Methods: Ninety-six intact premolars were divided into four groups: A) Conventional acid-etch and primer Transbond XT; B) Transbond Plus self-etch primer; and two self-etch bonding systems reinforced with silica dioxide nanofiller at different concentrations: C) Futurabond DC at 1%; D) Optibond All-in-One at 7%. Each group was allocated into two subgroups (n = 12) according to experimental time (12 and 24 hours). SBS test was performed using a universal testing machine. ARI scores were determined under a stereomicroscope. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to determine the size and distribution of nanofillers. One-way ANOVA was used to compare SBS followed by the post-hoc Tukey test. The chi-square test was used to evaluate ARI scores. Results: Mean SBS of Futurabond DC and Optibond All-in-One were significantly lower than conventional system, and there were no significant differences between means SBS obtained with all self-etch bonding systems used in the study. Lower ARI scores were found for Futurabond DC and Optibond All-in-One. There was no significant difference of SBS and ARI obtained at either time points for all bonding systems. Relative homogeneous distribution of the fillers was observed with the bonding systems. Conclusion: Two nanofilled systems revealed the lowest bond strengths, but still clinically acceptable and less adhesive was left on enamel. It is advisable not to load the brackets immediately to the maximum.


RESUMO Objetivo: avaliar o efeito das nanopartículas de dióxido de silício (SiO2), presentes em diferentes sistemas adesivos, na resistência ao cisalhamento da colagem (RAC) e no modo de fratura de braquetes ortodônticos avaliados em dois momentos. Métodos: noventa e seis pré-molares intactos foram divididos em quatro grupos: A) condicionador ácido convencional e primer Transbond XT; B) primer autocondicionador Transbond Plus; e dois sistemas adesivos autocondicionantes reforçados com nanopartículas de dióxido de silício em diferentes concentrações, C) DC Futurabond a 1%; D) Optibond All-In-One a 7%. Cada grupo foi dividido em dois subgrupos (n = 12), de acordo com o tempo para realização do teste (12 e 24 horas). O teste da RAC foi realizado em uma máquina universal de ensaios. Os resultados do índice de adesivo remanescente foram determinados com um estereomicroscópio. Para determinar o tamanho e a distribuição das nanopartículas, utilizou-se microscopia eletrônica de varredura (MEV) e microscopia eletrônica de transmissão (MET). O ANOVA a um critério foi usado para comparar a RAC, seguido pelo teste post-hoc de Tukey. O teste qui-quadrado foi usado para avaliar os índices de adesivo remanescente. Resultados: a RAC média do Futurabond DC e do Optibond All-In-One foi menor do que a do sistema convencional, de forma estatisticamente significativa; e não houve diferença estatisticamente significativa entre os níveis médios de RAC obtidos nos sistemas adesivos autocondicionantes avaliados nesse estudo. Os menores índices de adesivo remanescente foram observados com o Futurabond DC e o Optibond All-In-One. Não houve, entre os sistemas adesivos, diferença significativa na RAC e nos índices de adesivo remanescente obtidos nos dois tempos de aplicação. Foi observada uma distribuição relativamente homogênea das partículas nos sistemas adesivos. Conclusão: os dois sistemas com nanopartículas demonstraram menor RAC, mas ainda aceitável e com o menor índice de adesivo remanescente no esmalte. É, assim, aconselhável não submeter os braquetes à carga máxima logo após a colagem.


Assuntos
Humanos , Aço Inoxidável/química , Colagem Dentária , Braquetes Ortodônticos , Nanotecnologia , Cimentos Dentários/química , Resistência ao Cisalhamento , Condicionamento Ácido do Dente , Dente Pré-Molar , Teste de Materiais , Microscopia Eletrônica de Varredura , Análise do Estresse Dentário , Microscopia Eletrônica de Transmissão
14.
Braz. dent. j ; Braz. dent. j;26(5): 497-502, Oct. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-767626

RESUMO

Abstract: The aim of this study was to evaluate the microtensile bond strength of self-etch adhesive systems to dentin after storage in acids from oral biofilm. Three adhesive systems were used in the study: a two-step self-etch adhesive for use with a silorane-based resin composite (Filtek P90 adhesive system - P90), a two-step self-etch adhesive (Clearfil SE Bond - CSE) and a one-step self-etch adhesive (Adper Easy One - AEO). The bond strength of these products was evaluated by bonding resin composite (Filtek Z350 for CSE and AEO; and Filtek P90 for P90) to 90 bovine dentin tooth fragments, according to the manufacturer's instructions. After 24 h of water storage at 37 °C, the specimens were sectioned into beams (1 mm2) divided and stored in distilled water, lactic acid and propionic acid, for 7 and 30 days. After storage, the specimens were tested for microtensile bond strength. Data were analyzed by three-way ANOVA and Tukey´s test (α=0.05). CSE presented the highest microtensile bond strength after storage in distilled water for 7 and 30 days. The microtensile bond strength of all adhesive systems was lower after storage in lactic acid and propionic acid than after water storage. Significant difference was not found between storage times.


Resumo: O objetivo deste trabalho foi avaliar a resistência de união de sistemas adesivos autocondicionantes após estocagem em ácidos presentes no biofilme oral. Foram utilizados três sistemas adesivos: um autocondicionante de dois frascos indicado para uso com a resina composta à base de silorano (P90 System Adhesive- P90), um autocondicionante de dois frascos (Clearfil SE Bond - CSE) e um autocondicionante de frasco único (AdperEasyOne - AEO). Para avaliação da resistência de união à dentina, 90 fragmentos de dentes bovinos foram restaurados de acordo com as recomendações dos fabricantes. Após a confecção de blocos de resina composta (Filtek Z350 para os sistemas adesivos AEO e CSE; Filtek P90 para o sistema adesivo P90) e estocagem em água destilada por 24 h a 37 °C, os fragmentos foram seccionados para a obtenção de palitos (1 mm2) que foram divididos e estocados nos três diferentes meios de imersão (água destilada, ácido lático e ácido propiônico) por períodos de 7 dias e 30 dias (n=5). Em seguida, foi realizado o ensaio de resistência à microtração. Os dados foram submetidos à Análise de Variância (3 fatores) e ao Teste de Tukey (α=0,05). O sistema adesivo CSE apresentou maior resistência de união após imersão em água por 7 ou 30 dias. A resistência de união de todos os sistemas adesivos foi menor após imersão em ácido lático e propiônico do que após imersão em água. Não foi observada diferença significativa entre os tempos de imersão.


Assuntos
Animais , Bovinos , Ácidos/química , Biofilmes , Cimentos Dentários , Dentina , Condicionamento Ácido do Dente , Resistência à Tração
15.
J Dent ; 43(9): 1060-1070, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25908573

RESUMO

OBJECTIVES: To evaluate the effect of adhesion strategy on the enamel microshear bond strengths (µSBS), etching pattern, and in situ degree of conversion (DC) of seven universal adhesives. METHODS: 84 extracted third molars were sectioned in four parts (buccal, lingual, proximal) and divided into 21 groups, according to the combination of the main factors adhesive (AdheSE Universal [ADU], All-Bond Universal [ABU], Clearfil Universal [CFU], Futurabond U [FBU], G-Bond Plus [GBP], Prime&Bond Elect (PBE), and Scotchbond Universal Adhesive [SBU]), and adhesion strategy (etch-and-rinse, active self-etch, and passive self-etch). Specimens were stored in water (37°C/24h) and tested at 1.0mm/min (µSBS). Enamel-resin interfaces were evaluated for DC using micro-Raman spectroscopy. The enamel-etching pattern was evaluated under a field-emission scanning electron microscope (direct and replica techniques). Data were analyzed with two-way ANOVA and Tukey's test (α=0.05). RESULTS: Active self-etch application increased µSBS and DC for five out of the seven universal adhesives when compared to passive application (p<0.001). A deeper enamel-etching pattern was observed for all universal adhesives in the etch-and-rinse strategy. A slight improvement in etching ability was observed in active self-etch application compared to that of passive self-etch application. Replicas of GBP and PBE applied in active self-etch mode displayed morphological features compatible with water droplets. The DC of GBP and PBE were not affected by the application/strategy mode. CONCLUSIONS: In light of the improved performance of universal adhesives when applied actively in SE mode, selective enamel etching with phosphoric acid may not be crucial for their adhesion to enamel. CLINICAL SIGNIFICANCE: The active application of universal adhesives in self-etch mode may be a practical alternative to enamel etching in specific clinical situations.


Assuntos
Cimentos Dentários , Esmalte Dentário , Corrosão Dentária/métodos , Dente Molar , Análise de Variância , Cimentos Dentários/química , Esmalte Dentário/química , Esmalte Dentário/ultraestrutura , Falha de Restauração Dentária , Humanos , Microscopia Eletrônica de Varredura , Dente Molar/química , Dente Molar/ultraestrutura , Ácidos Fosfóricos/administração & dosagem , Distribuição Aleatória , Resistência ao Cisalhamento , Análise Espectral Raman , Água
16.
Braz. dent. j ; Braz. dent. j;26(1): 3-10, Jan-Feb/2015. graf
Artigo em Inglês | LILACS | ID: lil-735835

RESUMO

This paper presents the state of the art of self-etch adhesive systems. Four topics are shown in this review and included: the historic of this category of bonding agents, bonding mechanism, characteristics/properties and the formation of acid-base resistant zone at enamel/dentin-adhesive interfaces. Also, advantages regarding etch-and-rinse systems and classifications of self-etch adhesive systems according to the number of steps and acidity are addressed. Finally, issues like the potential durability and clinical importance are discussed. Self-etch adhesive systems are promising materials because they are easy to use, bond chemically to tooth structure and maintain the dentin hydroxyapatite, which is important for the durability of the bonding.


Este artigo apresenta o estado da arte de sistemas adesivos autocondicionantes. Quatro temas são apresentados nesta revisão: o histórico desta categoria de agentes de união, o mecanismo de adesão, as características/propriedades, e a formação da zona ácido-base resistente nas interfaces esmalte/dentina-adesivo. Além disso, as vantagens relativas aos sistemas de condicionamento total ( etch-and-rinse ) e as classificações dos sistemas adesivos autocondicionantes de acordo com o número de passos e acidez são abordados. Por fim, são discutidas questões como a durabilidade potencial e a importância clínica. Sistemas adesivos autocondicionantes são materiais promissores porque são fáceis de usar, unem-se quimicamente à estrutura do dente e preservam a hidroxiapatita dentinária, o que é importante para a durabilidade da ligação.


Assuntos
Humanos , Colagem Dentária/métodos , Adesivos Dentinários/química , Condicionamento Ácido do Dente , Teste de Materiais , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo
17.
J Dent ; 43(1): 140-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25046536

RESUMO

OBJECTIVES: The aim of this 24-month double-blind randomized paired-tooth clinical study was to evaluate the 2-year clinical performance of two self-etch adhesives containing or not chlorhexidine digluconate (CHX) in non-carious cervical lesions (NCCLs). METHODS: Twenty-two patients, with at least four NCCLs, participated in this study. After sample size calculation, 126 restorations were assigned to one of the following groups: CSE--Clearfil SE Bond (Kuraray); CSE/CHX--Clearfil SE Bond+CHX; ADS--AdheSE (Ivoclar Vivadent); and ADS/CHX--AdheSE+CHX. The composite resin Filtek Z-250 composite (3M ESPE) was placed incrementally by one expert operator. The restorations were evaluated at baseline and after 2 years using the modified USPHS criteria. Statistical analyses were performed with Friedman repeated measures ANOVA by rank and Fisher exact test for significance in each pair (α=0.05). RESULTS: No significant difference was observed between baseline and 2-year for any criteria when adhesives with and without the addition of CHX were compared (p>0.05). ADS and ADS/CHX resulted in lower retention rates (82% on average) than CSE and CSE/CHX (97%) (p=0.02). CONCLUSIONS: The inclusion of CHX into the primer of both self-etch systems did not add clinical advantages over the 2-year period. Clearfil SE Bond resulted in better retention rate than AdheSE. CLINICAL SIGNIFICANCE: It is more important to choose a gold standard self-etch adhesive, like a Clearfil SE Bond, than to consider the inclusion of CHX in the self-etch adhesives.


Assuntos
Clorexidina/administração & dosagem , Cimentos Dentários/uso terapêutico , Restauração Dentária Permanente , Colo do Dente/efeitos dos fármacos , Adulto , Clorexidina/efeitos adversos , Colagem Dentária , Cimentos Dentários/efeitos adversos , Falha de Restauração Dentária , Dentina/efeitos dos fármacos , Dentina/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cimentos de Resina/uso terapêutico , Colo do Dente/patologia
18.
Artigo em Espanhol | LILACS | ID: lil-734838

RESUMO

La aplicación de adhesivos dentarios autograbantes que contienen 10-metacriloxidecilfosfato dihidrogenado supera la resistencia a la biodegradación de la interfase adhesiva de los sistemas tradicionales de grabado total. El mecanismo de acción se basa en la formación de múltiples nanocapas de calcio unido a 2 moléculas 10-metacriloxidecilfosfato dihidrogenado sobre la dentina; estas múltiples capas de 3,5 nm son las que protegerían las fibras colágenas del fenómeno de hidrólisis. Las nanocapas explicarían su alta estabilidad en el tiempo y la fortaleza de la unión, probadas tanto en estudios clínicos como de laboratorio. La interacción con la hidroxiapatita sucede con ácidos de pH bajos, pero mayores que los tradicionales, por lo que surge la necesidad de recomendar el grabado selectivo previo del esmalte. El uso de metacriloxidecilfosfato dihidrogenado permite el cambio de filosofía adhesiva desde el grabado total a la integración adhesiva de la dentina.


Applying self-etching dental adhesives containing 10-MDP overcomes the resistance to biodegradation of the adhesive interface of traditional total etch. The mechanism of action is based on the formation of multiple nano-layers of calcium and two molecules of 10-MDP on the dentin surface. These multiple layers of 3.5 nm protect the collagen fibers from hydrolysis phenomenon. The nano-layer explains its high stability and bond strength over time, tested both by clinical and laboratory studies. Hydroxyapatite interaction occurs with acids of low pH, but are higher than traditional, thus increasing the need to recommend the previous selective etching of the enamel. The use of MDP allows a change of philosophy from the total-etch adhesive to adhesive integration of the dentin.


Assuntos
Humanos , Adesivos Dentinários , Cimentos Dentários , Corrosão Dentária , Metacrilatos , Dentina
19.
Dent Mater ; 30(10): 1126-35, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25139815

RESUMO

OBJECTIVE: To evaluate the microtensile bond strengths (µTBS) and nanoleakage (NL) of three universal or multi-mode adhesives, applied with increasing solvent evaporation times. METHODS: One-hundred and forty caries-free extracted third molars were divided into 20 groups for bond strength testing, according to three factors: (1) Adhesive - All-Bond Universal (ABU, Bisco, Inc.), Prime&Bond Elect (PBE, Dentsply), and Scotchbond Universal Adhesive (SBU, 3M ESPE); (2) Bonding strategy - self-etch (SE) or etch-and-rinse (ER); and (3) Adhesive solvent evaporation time - 5s, 15s, and 25s. Two extra groups were prepared with ABU because the respective manufacturer recommends a solvent evaporation time of 10s. After restorations were constructed, specimens were stored in water (37°C/24h). Resin-dentin beams (0.8mm(2)) were tested at 0.5mm/min (µTBS). For NL, forty extracted molars were randomly assigned to each of the 20 groups. Dentin disks were restored, immersed in ammoniacal silver nitrate, sectioned and processed for evaluation under a FESEM in backscattered mode. Data from µTBS were analyzed using two-way ANOVA (adhesive vs. drying time) for each strategy, and Tukey's test (α=0.05). NL data were computed with non-parametric tests (Kruskal-Wallis and Mann-Whitney tests, α=0.05). RESULTS: Increasing solvent evaporation time from 5s to 25s resulted in statistically higher mean µTBS for all adhesives when used in ER mode. Regarding NL, ER resulted in greater NL than SE for each of the evaporation times regardless of the adhesive used. A solvent evaporation time of 25s resulted in the lowest NL for SBU-ER. SIGNIFICANCE: Residual water and/or solvent may compromise the performance of universal adhesives, which may be improved with extended evaporation times.


Assuntos
Cimentos Dentários , Dentina , Solventes/química , Infiltração Dentária , Humanos , Resistência à Tração
20.
J Dent ; 42(5): 595-602, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24508503

RESUMO

OBJECTIVES: To evaluate the effect of an additional hydrophobic resin coating (HE) on the resin-dentine microtensile bond strengths (µTBS), nanoleakage (NL), and in situ degree of conversion (DC) of three universal adhesives used in the etch-and-rinse (ER) and the self-etch (SE) modes. METHODS: Sixty caries-free extracted third molars were divided into 12 groups according to the combination of the factors adhesive (All-Bond Universal [ABU]; G-Bond Plus [GBP] and Scotchbond Universal [SBU]), adhesive strategy (ER and SE), and the use of HE (Heliobond; yes or no). After restorations were constructed, specimens were stored in water (37°C/24h) and sectioned into resin-dentine beams (0.8mm(2)) to be tested under tension (0.5mm/min). Selected beams from each tooth were used for DC quantification and for NL evaluation. Data from each adhesive were analyzed with two-way ANOVA and Tukey's test (α=0.05). RESULTS: ABU and GBP resulted in higher µTBS in the ER mode. The use of HE increased the µTBS of ABU and GBP only in the SE mode. Lower NL was observed for SBU and ABU in the ER mode+HE, and for GBP in the SE mode+HE. SBU and GBP showed higher DC when used in the ER mode, which was increased with HE application. The DC of ABU was similar in all conditions. CONCLUSIONS: The conversion of 1-step SE to 2-step SE may increase the µTBS and DC of current universal adhesives. The reduction in the NL is more dependent on the adhesive composition than on the bonding strategy.


Assuntos
Resinas Compostas/química , Colagem Dentária , Materiais Dentários/química , Dentina/ultraestrutura , Cimentos de Resina/química , Condicionamento Ácido do Dente/métodos , Acrilatos/química , Bis-Fenol A-Glicidil Metacrilato/química , Infiltração Dentária/classificação , Humanos , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais , Metacrilatos/química , Ácidos Fosfóricos/química , Polietilenoglicóis/química , Polimerização , Ácidos Polimetacrílicos/química , Distribuição Aleatória , Temperatura , Resistência à Tração , Fatores de Tempo , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA