Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
1.
São Paulo; 2024. 35 p.
Tese em Português | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: bud-5336

RESUMO

The ex situ reproduction of wild animals still faces several obstacles, such as minimum reproductive rates or even reproductive inactivity, data that makes specialists worried considering the growing number of species threatened with extinction. Reproductive biotechniques are already well developed among farm animals and widely used in conservation programs, but studies are still needed to develop protocols adapted for snakes, regarding their wide variety of species and their particularities. Therefore, this work seeks to compare sperm survival over time in Oxyrhopus guibei when kept at 24°C and under refrigeration. For this, sperm analysis will be made by evaluating parameters such as motility, progressive motility, presence of morphological changes and mitochondrial activity in spermatozoa. Three males of O. guibei were used, belonging to the Ecology and Evolution Laboratory of the Butantan Institute, and semen was collected via digital stimulation without the use of local anesthesia. This study showed that it is possible to maintain O. guibei sperm cells in HAM-F10 cell culture medium for up to 8 hours at 24°C and for up to 48 hours under refrigeration at 4°C.


A reprodução de animais silvestres ex situ ainda enfrenta diversos obstáculos, como taxas reprodutivas mínimas ou até mesmo inatividade reprodutiva, dados que preocupam especialistas considerando o crescente número de espécies ameaçadas de extinção. As biotécnicas reprodutivas são bem desenvolvidas entre animais de produção e amplamente empregadas em programas de conservação, porém ainda carecem estudos para desenvolvimento de protocolos adaptados para serpentes, tendo em vista a grande variedade de espécies e suas particularidades. Dessa forma, este trabalho busca comparar a sobrevivência espermática ao longo do tempo em Oxyrhopus guibei quando mantidas a 24°C e sob refrigeração. Para isso, foi feita a análise espermática avaliando parâmetros como motilidade, motilidade progressiva, presença de alterações morfológicas e a atividade mitocondrial em células espermáticas. Foram utilizados 3 machos de O. guibei, pertencentes ao plantel do Laboratório de Ecologia e Evolução do Instituto Butantan e foi feita a colheita de sêmen via estimulação digital sem uso de anestesia local. Este estudo mostrou que é possível manter espermatozoides de O. guibei em meio HAM-F10 por até 8 horas a 24°C e por até 48h sob refrigeração, a 4°C.

2.
Data Brief ; 47: 108854, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36798599

RESUMO

The present work exhibits the dynamic viscosity profile data of three distinct nanofluids, at a constant shear stress, and within a range of temperatures that include below-ambient conditions (from -10 to 20 °C). The nanofluids were as follows. Nanofluid I: 30% ethylene glycol and 70% distilled water (v/v), with graphene (0.32% in mass); Nanofluid II: 30% engine coolant NBR 13705; ASTM D-3306; ASTM D-4985) and 70% distilled water (v/v), with graphene (0.2% in mass); and Nanofluid III: 30% engine coolant and 70% distilled water (v/v), with Multi-Walled Carbon Nanotubes (MWCNT) (0.2% in mass). The present work was motivated by the scarcity of experimental data on the temperature dependence of viscosity for graphene, MWCNT, and their hybrid nanofluids, at below-ambient temperatures.

3.
Rev. bras. reprod. anim ; 47(1): 3-21, jan.-mar. 2023.
Artigo em Português | VETINDEX | ID: biblio-1434873

RESUMO

Na atual conjuntura da criação artificial de bovinos e bubalinos, o material genético masculino de qualidade superior de reprodutores é explorado ao máximo possível através da inseminação artificial em tempo fixo de um grande número de fêmeas com apenas um único ejaculado. Para isso, é necessário um sêmen de boa qualidade que desempenhe um papel indispensável na melhoria das taxas de fertilidade, independente de qual tipo seja utilizado (fresco, refrigerado e congelado). Porém, o processo de congelação/descongelação causa uma série de injúrias aos espermatozoides, ocasionando resultados inferiores para percentuais de viabilidade espermática, motilidade, membrana plasmática e integridade acrossomal, potencial de membrana mitocondrial, cinemática do esperma, quando comparado ao sêmen refrigerado. Assim, o objetivo desta revisão é disseminar o conhecimento sobre o uso sêmen refrigerado na preservação de germoplasma de reprodutores bovinos e bubalinos para melhorar as taxas de concepção em propriedades. Para isso, serão abordados comentários sobre o armazenamento do sêmen refrigerado, com ênfase nas diferenças entre curvas de refrigeração, suas vantagens e desvantagens relativas para procedimentos de uso na IATF, identificando o método mais indicado por diversos autores, o estado atual da biotécnica, seus méritos e possibilidades futuras.(AU)


In the current conjuncture of the artificial creation of bovines and buffaloes, the male genetic material of superior quality of sires is exploited to the maximum possible through the fixed-time artificial insemination of a large number of females with only a single ejaculate. For this, a good quality semen is needed that plays an indispensable role in improving fertility rates, regardless of which type is used (fresh, chilled and frozen). However, the freezing/thawing process causes a series of injuries to spermatozoa, causing lower results for percentages of sperm viability, motility, plasma membrane and acrosomal integrity, mitochondrial membrane potential, sperm kinematics, when compared to refrigerated semen. Thus, the objective of this review is to disseminate knowledge about the use of chilled semen in the preservation of germplasm of bovine and buffalo breeders to improve conception rates in properties. For this, comments on the storage of refrigerated semen will be addressed, with emphasis on the differences between refrigeration curves, their relative advantages and disadvantages for procedures for use in FTAI, identifying the method most indicated by several authors, the current state of biotechnics, its future merits and possibilities.(AU)


Assuntos
Animais , Preservação do Sêmen/veterinária , Bovinos , Inseminação Artificial/veterinária , Técnicas de Diluição do Indicador/veterinária
4.
Ars vet ; 38(3): 98-103, 2022. tab
Artigo em Inglês | VETINDEX | ID: biblio-1417109

RESUMO

Meat is a very perishable product with a short shelf life, so the use of low temperatures is used to reduce the speed of chemical reactions, inhibit the growth of microorganisms, thus increasing the shelf life of this food. The objective of this work was to evaluate the temperature of fresh beef in refrigeration counters, and to monitor the temperature of this equipment in the butcher shop in the city of Cametá, Pará, Brazil, comparing it with the current legislation. In total, fifteen butcher shops were selected for this study, a skewer thermometer was used to measure the temperature of the meat, and a digital infrared thermometer was used for the counters. A statistical analysis was performed using Student's T test, using the average temperatures of the meats and the counters. It was found that among the temperatures, 23,33% of the meat samples (7/30) had their averages above the reference average (7°C), as well as the temperatures of the counters with 86,66% of the equipment (13/15), had an average temperature above the legal limit, which is 7°C. The study showed that the temperature of the counters and beef in the butchers were out of the quality standard, therefore a risk to consumer health, requiring stricter inspection and training of employees by public agencies.


A carne é um produto muito perecível com vida útil curta, assim o emprego de baixas temperaturas é utilizado para diminuir a velocidade das reações químicas, inibir o crescimento dos microrganismos, aumentado assim a da útil desse alimento. O objetivo deste trabalho, foi avaliar a temperatura de carnes bovinas in natura em balcões de refrigeração, e monitorar a temperatura destes equipamentos no comércio dos açougues no município de Cametá estado do Pará, Brasil, comparando com a legislação vigente. No total, quinze açougues foram selecionados para este estudo, na aferição da temperatura da carne foi utilizado um termômetro de espeto, e para os balcões, foi utilizado um termômetro digital infravermelho. Foi realizada uma análise estatística por meio do teste t de Student, utilizando as médias das temperaturas das carnes e dos balcões. Constatou-se que dentre as temperaturas, 23,33% das amostras de carne (7/30) estavam com suas médias acima da média referência (7°C), bem como as temperaturas dos balcões, com 86,66% dos equipamentos (13/15), estavam com a média da temperatura acima do permitido, pela legislação, que é de 7°C. O estudo demonstrou que a temperatura dos balcões e das carnes bovinas nos açougues, estavam fora do padrão de qualidade, portanto um risco a saúde do consumidor, sendo necessário uma fiscalização mais rigorosa e a capacitação de funcionários por parte dos órgãos públicos.


Assuntos
Indústria da Carne/instrumentação , Alimentos Resfriados , Carne Vermelha/análise , Brasil , Qualidade dos Alimentos , Saneamento de Mercados
5.
Ciênc. rural (Online) ; 52(01): 1-6, 2022. tab
Artigo em Inglês | VETINDEX | ID: biblio-1480296

RESUMO

Eggshell quality is directly linked to the good acceptability of the product by consumers, whereas the industry is concerned with economic losses. Prolonged periods of laying, diseases, nutrition, bird age and genetics can influence egg quality. This study aimed to examine the influence of the environment, bird age and storage period on the physical characteristics of the shell of eggs from commercial laying hens. The experiment involved 288 eggs from Hy-line hens, which were distributed in a completely randomized design with a triple 3×2×4 factorial arrangement represented by three ages (31, 62 or 88 weeks), two storage temperatures (ambient or refrigerated), and four storage periods (one, 10, 20 or 30 days), totaling 24 treatments. Four replications were used with three eggs each. Eggshell strength, percentage and thickness were measured. Differences were observed, with the eggs stored at room temperature exhibiting lower shell strength. Laying eggs at an advanced age (88 weeks) resulted in decreased eggshell strength as compared with the other ages, whereas the eggs from young layers (31 weeks) had a thicker shell. The advancing age of the laying hens reduced eggshell quality, regardless of the storage environment. Nonetheless, the eggs stored in the refrigerator showed better eggshell quality and integrity than those stored at ambient temperature.


A qualidade da casca está diretamente ligada à boa aceitabilidade do produto pelos consumidores, enquanto a indústria se preocupa com as perdas econômicas. Períodos prolongados de postura, doenças, nutrição, idade da ave e genética podem influenciar a qualidade dos ovos. Objetivou-se avaliar a influência do ambiente, idade da ave e período de armazenamento nas características físicas da casca de ovos de poedeiras comerciais. Foram utilizados 288 ovos de poedeiras Hy-line, distribuídos em um delineamento inteiramente casualizado em fatorial triplo 3x2x4, sendo os fatores: três idades (31, 62 e 88 semanas), temperatura de armazenamento (ambiente e refrigerado), e quatro períodos de armazenamento (um, 10, 20 e 30 dias), totalizando 24 tratamentos, com quatro repetições de três ovos. Avaliou-se a resistência, percentual e espessura da casca. Foram observadas diferenças, uma vez que os ovos armazenados em temperatura ambiente apresentaram diminuição na resistência de casca. Ovos de poedeiras em idade avançada (88 semanas) apresentaram pior resistência de casca em relação às demais idades, enquanto ovos provenientes de poedeiras jovens (31 semanas) apresentaram maior espessura de casca. A idade avançada da poedeira reduziu a qualidade de casca dos ovos, independentemente do ambiente de armazenamento. Ainda, os ovos armazenados em geladeira apresentaram melhor qualidade e integridade da casca em comparação com os armazenados ao ambiente.


Assuntos
Casca de Ovo , Qualidade dos Alimentos , Temperatura
6.
Ci. Rural ; 52(01): 1-6, 2022. tab
Artigo em Inglês | VETINDEX | ID: vti-764656

RESUMO

Eggshell quality is directly linked to the good acceptability of the product by consumers, whereas the industry is concerned with economic losses. Prolonged periods of laying, diseases, nutrition, bird age and genetics can influence egg quality. This study aimed to examine the influence of the environment, bird age and storage period on the physical characteristics of the shell of eggs from commercial laying hens. The experiment involved 288 eggs from Hy-line hens, which were distributed in a completely randomized design with a triple 3×2×4 factorial arrangement represented by three ages (31, 62 or 88 weeks), two storage temperatures (ambient or refrigerated), and four storage periods (one, 10, 20 or 30 days), totaling 24 treatments. Four replications were used with three eggs each. Eggshell strength, percentage and thickness were measured. Differences were observed, with the eggs stored at room temperature exhibiting lower shell strength. Laying eggs at an advanced age (88 weeks) resulted in decreased eggshell strength as compared with the other ages, whereas the eggs from young layers (31 weeks) had a thicker shell. The advancing age of the laying hens reduced eggshell quality, regardless of the storage environment. Nonetheless, the eggs stored in the refrigerator showed better eggshell quality and integrity than those stored at ambient temperature.(AU)


A qualidade da casca está diretamente ligada à boa aceitabilidade do produto pelos consumidores, enquanto a indústria se preocupa com as perdas econômicas. Períodos prolongados de postura, doenças, nutrição, idade da ave e genética podem influenciar a qualidade dos ovos. Objetivou-se avaliar a influência do ambiente, idade da ave e período de armazenamento nas características físicas da casca de ovos de poedeiras comerciais. Foram utilizados 288 ovos de poedeiras Hy-line, distribuídos em um delineamento inteiramente casualizado em fatorial triplo 3x2x4, sendo os fatores: três idades (31, 62 e 88 semanas), temperatura de armazenamento (ambiente e refrigerado), e quatro períodos de armazenamento (um, 10, 20 e 30 dias), totalizando 24 tratamentos, com quatro repetições de três ovos. Avaliou-se a resistência, percentual e espessura da casca. Foram observadas diferenças, uma vez que os ovos armazenados em temperatura ambiente apresentaram diminuição na resistência de casca. Ovos de poedeiras em idade avançada (88 semanas) apresentaram pior resistência de casca em relação às demais idades, enquanto ovos provenientes de poedeiras jovens (31 semanas) apresentaram maior espessura de casca. A idade avançada da poedeira reduziu a qualidade de casca dos ovos, independentemente do ambiente de armazenamento. Ainda, os ovos armazenados em geladeira apresentaram melhor qualidade e integridade da casca em comparação com os armazenados ao ambiente.(AU)


Assuntos
Casca de Ovo , Temperatura , Qualidade dos Alimentos
7.
Ciênc. rural (Online) ; 52(1): e20200908, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1339653

RESUMO

ABSTRACT: Eggshell quality is directly linked to the good acceptability of the product by consumers, whereas the industry is concerned with economic losses. Prolonged periods of laying, diseases, nutrition, bird age and genetics can influence egg quality. This study aimed to examine the influence of the environment, bird age and storage period on the physical characteristics of the shell of eggs from commercial laying hens. The experiment involved 288 eggs from Hy-line hens, which were distributed in a completely randomized design with a triple 3×2×4 factorial arrangement represented by three ages (31, 62 or 88 weeks), two storage temperatures (ambient or refrigerated), and four storage periods (one, 10, 20 or 30 days), totaling 24 treatments. Four replications were used with three eggs each. Eggshell strength, percentage and thickness were measured. Differences were observed, with the eggs stored at room temperature exhibiting lower shell strength. Laying eggs at an advanced age (88 weeks) resulted in decreased eggshell strength as compared with the other ages, whereas the eggs from young layers (31 weeks) had a thicker shell. The advancing age of the laying hens reduced eggshell quality, regardless of the storage environment. Nonetheless, the eggs stored in the refrigerator showed better eggshell quality and integrity than those stored at ambient temperature.


RESUMO: A qualidade da casca está diretamente ligada à boa aceitabilidade do produto pelos consumidores, enquanto a indústria se preocupa com as perdas econômicas. Períodos prolongados de postura, doenças, nutrição, idade da ave e genética podem influenciar a qualidade dos ovos. Objetivou-se avaliar a influência do ambiente, idade da ave e período de armazenamento nas características físicas da casca de ovos de poedeiras comerciais. Foram utilizados 288 ovos de poedeiras Hy-line, distribuídos em um delineamento inteiramente casualizado em fatorial triplo 3x2x4, sendo os fatores: três idades (31, 62 e 88 semanas), temperatura de armazenamento (ambiente e refrigerado), e quatro períodos de armazenamento (um, 10, 20 e 30 dias), totalizando 24 tratamentos, com quatro repetições de três ovos. Avaliou-se a resistência, percentual e espessura da casca. Foram observadas diferenças, uma vez que os ovos armazenados em temperatura ambiente apresentaram diminuição na resistência de casca. Ovos de poedeiras em idade avançada (88 semanas) apresentaram pior resistência de casca em relação às demais idades, enquanto ovos provenientes de poedeiras jovens (31 semanas) apresentaram maior espessura de casca. A idade avançada da poedeira reduziu a qualidade de casca dos ovos, independentemente do ambiente de armazenamento. Ainda, os ovos armazenados em geladeira apresentaram melhor qualidade e integridade da casca em comparação com os armazenados ao ambiente.

8.
Av. enferm ; 39(2): 178-187, 01 may 2021.
Artigo em Português | LILACS, BDENF - Enfermagem, COLNAL | ID: biblio-1290949

RESUMO

Objetivo: compreender o significado da conservação de vacinas e do cuidado na sala de vacinação para a equipe de enfermagem de unidades de atenção primária à saúde. Materiais e métodos: estudo qualitativo, sob o olhar e a perspectiva da fenomenologia social de Alfred Schütz, realizado em março de 2018, por meio de entrevista aberta com profissionais de enfermagem atuantes na sala de vacinação. Resultados: com base na análise das entrevistas, os resultados foram organizados em três categorias: Manter a conservação de vacinas é cuidar da qualidade e da segurança, Agir no presente e pensar no futuro e Sala de vacinação ideal. Os profissionais compreendem a importância da conservação de vacinas pautada na qualidade, na segurança e na demanda por melhorias na estruturação das salas de vacinação. Conclusões: a equipe de enfermagem percebe a necessidade de manter a cadeia de frio de conservação dos imunobiológicos em todas as instâncias, com expectativas e desejos de aquisição de equipamentos, para melhorar a estrutura física e a oferta de cuidado empático a fim de prevenir doenças.


Objetivo: comprender el significado de la conservación de las vacunas y los cuidados en la sala de vacunación para el personal de enfermería de las unidades de atención primaria. Materiales y métodos: estudio cualitativo, desde la perspectiva de la fenomenología social de Alfred Schütz, realizado en marzo de 2018 mediante entrevistas abiertas a profesionales de enfermería que trabajan en salas de vacunación. Resultados: a partir del análisis de las entrevistas, los resultados se organizaron en tres categorías: Mantener la conservación de las vacunas es cuidar la calidad y la seguridad, Actuar en el presente y pensar en el futuro y Sala de vacunación ideal. Los profesionales comprenden la importancia de la conservación de las vacunas en función de la calidad, la seguridad y la demanda por mejoras en la estructura de las salas de vacunación. Conclusiones: el equipo de enfermería percibe la necesidad de mantener la cadena de frío de la conservación inmunobiológica en todas las instancias, con expectativas y deseos de adquirir equipos, mejorar la estructura física y ofrecer cuidados empáticos para prevenir enfermedades.


Objective: To understand the meaning of vaccine conservation and vaccination room care for the nursing staff of primary health care units. Materials and methods: Qualitative study, under the perspective of Alfred Schütz's social phenomenology, conducted in March 2018 through an open interview with nursing professionals working at a vaccination room. Results: Based on the analysis of the interviews, results were organized in three categories: Maintaining vaccine conservation is taking care of quality and safety, Acting in the present and thinking about the future, and Ideal vaccination room. The professionals understand the importance of vaccine conservation based on quality and safety standards, and thus demand improvements in the structure of vaccination rooms. Conclusions: Nursing teams perceive the need to maintain the cold chain of conservation of immunobiologicals in all instances, with expectations and desires towards the acquisition of equipment, improvements in the physical structure of vaccination rooms, and, therefore, offering a more empathic care in order to prevent diseases.


Assuntos
Humanos , Atenção Primária à Saúde , Refrigeração , Vacinas , Pesquisa Qualitativa , Equipe de Enfermagem
9.
Ars vet ; 37(1): 05-09, 2021.
Artigo em Português | VETINDEX | ID: biblio-1463570

RESUMO

O tratamento do leite em ultra alta temperatura (UAT) possibilita a eliminação de patógenos e aumento do tempo de prateleira, no entanto, bactérias psicrotróficas são associadas a efeitos negativos no produto, como lipólise, rancificação e a geleificação. Resultado da resistência de alguns esporos ao processamento, e à possível atividade residual de enzimas termorresistentes. Assim, o objetivo deste estudo foi enumerar bactérias psicrotróficas e realizar a prova de lactofermentação em leites UAT comercializados na região de Curitiba, Paraná. Foram adquiridas 60 amostras de duas marcas (30 da marca A e 30 da marca B) quinzenalmente em três diferentes momentos. Em cada momento 10 amostras de um mesmo lote eram separadas em dois grupos (D0 e D7), sendo D0: cinco amostras avaliadas no dia da compra, e D7: cinco amostras avaliadas após incubação a 37± 1ºC/7 dias e analisadas quanto à enumeração de bactérias psicrotróficas, coloração de Gram e prova da lactofermentação. Em D0, uma (3,4%) amostra (marca A) apresentou crescimento de psicrotróficos (2,50 x 105 UFC/mL), Gram negativos. As amostras da marca B não apresentaram crescimento microbiano. Vinte e cinco (83,3%) amostras não formaram coágulo, e cinco (16,7%) produziram coágulo esponjoso. Em D7, nenhuma amostra apresentou contagem bacteriana, 20 (66,7%) não produziram coágulo e 10 (33,3%) produziram coágulo esponjoso. O processo UAT utilizado pela marca A não garantiu efetividade na redução de bactérias psicrotróficas, e o resultado do teste de lactofermentação indica a possível contaminação por coliformes em ambas as marcas. Ainda, a ausência de coágulos em diversas amostras pode ser um indicativo do uso de conservantes, o que é considerado fraude.


The beneficial effects of ultra-pasteurization milk treatment include elimination of milk pathogens, besides increasing the product's shelf-life, however, psychrotrophic bacteria are associated with several negative effects in the final product such as lipolysis, rancidification and gelation. This results from heat-resistant spores and its possible residual extracellular heat-resistant enzymes activity. With that in mind, this paper aimed to quantify psychrotrophic bacteria and perform a milk clotting test in UHT milk sold in Curitiba, Paraná. 60 samples from two brands were acquired (30 from A brand and 30 from B brand) each 15 days in different moments. Each time, 10 samples from a same batch were separated in two groups (D0 and D7), being D0: five samples analyzed in the purchase day, and D7: five samples analyzed after incubation at 37± 1ºC/7 days and evaluated regarding enumeration of psychrotrophic bacteria, Gram staining and milk clotting test. The heat-treating process effectiveness was evaluated by analyzing 30 samples from each brand, A and B, totalizing 60, being 10 from each different production batches, through the surface inoculation method in PCA, milk clotting test and classification of the isolated colonies by the Gram method. In D0, one (3,4%) sample (from A brand) resulted in Gram negative psychrotrophic growing (2,50 x 105 UFC/mL) . Samples from B brand did not result in bacterial growth. 25 samples (83,3%) did not clot, and five (16,7%) produced sponge clots. In D7, none of the samples presented bacterial growth, 20 (66,7%) did not clot and 10 (33,3%) produced sponge clots. Mesophilic bacterial culture was not done. The A brand UHT process did not grant sterilization regarding psychrotrophic bacteria, and the milk clotting results indicate possible coliforms contamination in both brands. Furthermore, clot absence in several samples could indicate preservatives usage, which is considered fraud.


Assuntos
Leite/fisiologia , Leite/química , Temperatura Alta , Técnicas Microbiológicas
10.
Ars Vet. ; 37(1): 05-09, 2021.
Artigo em Português | VETINDEX | ID: vti-30669

RESUMO

O tratamento do leite em ultra alta temperatura (UAT) possibilita a eliminação de patógenos e aumento do tempo de prateleira, no entanto, bactérias psicrotróficas são associadas a efeitos negativos no produto, como lipólise, rancificação e a geleificação. Resultado da resistência de alguns esporos ao processamento, e à possível atividade residual de enzimas termorresistentes. Assim, o objetivo deste estudo foi enumerar bactérias psicrotróficas e realizar a prova de lactofermentação em leites UAT comercializados na região de Curitiba, Paraná. Foram adquiridas 60 amostras de duas marcas (30 da marca A e 30 da marca B) quinzenalmente em três diferentes momentos. Em cada momento 10 amostras de um mesmo lote eram separadas em dois grupos (D0 e D7), sendo D0: cinco amostras avaliadas no dia da compra, e D7: cinco amostras avaliadas após incubação a 37± 1ºC/7 dias e analisadas quanto à enumeração de bactérias psicrotróficas, coloração de Gram e prova da lactofermentação. Em D0, uma (3,4%) amostra (marca A) apresentou crescimento de psicrotróficos (2,50 x 105 UFC/mL), Gram negativos. As amostras da marca B não apresentaram crescimento microbiano. Vinte e cinco (83,3%) amostras não formaram coágulo, e cinco (16,7%) produziram coágulo esponjoso. Em D7, nenhuma amostra apresentou contagem bacteriana, 20 (66,7%) não produziram coágulo e 10 (33,3%) produziram coágulo esponjoso. O processo UAT utilizado pela marca A não garantiu efetividade na redução de bactérias psicrotróficas, e o resultado do teste de lactofermentação indica a possível contaminação por coliformes em ambas as marcas. Ainda, a ausência de coágulos em diversas amostras pode ser um indicativo do uso de conservantes, o que é considerado fraude.(AU)


The beneficial effects of ultra-pasteurization milk treatment include elimination of milk pathogens, besides increasing the product's shelf-life, however, psychrotrophic bacteria are associated with several negative effects in the final product such as lipolysis, rancidification and gelation. This results from heat-resistant spores and its possible residual extracellular heat-resistant enzymes activity. With that in mind, this paper aimed to quantify psychrotrophic bacteria and perform a milk clotting test in UHT milk sold in Curitiba, Paraná. 60 samples from two brands were acquired (30 from A brand and 30 from B brand) each 15 days in different moments. Each time, 10 samples from a same batch were separated in two groups (D0 and D7), being D0: five samples analyzed in the purchase day, and D7: five samples analyzed after incubation at 37± 1ºC/7 days and evaluated regarding enumeration of psychrotrophic bacteria, Gram staining and milk clotting test. The heat-treating process effectiveness was evaluated by analyzing 30 samples from each brand, A and B, totalizing 60, being 10 from each different production batches, through the surface inoculation method in PCA, milk clotting test and classification of the isolated colonies by the Gram method. In D0, one (3,4%) sample (from A brand) resulted in Gram negative psychrotrophic growing (2,50 x 105 UFC/mL) . Samples from B brand did not result in bacterial growth. 25 samples (83,3%) did not clot, and five (16,7%) produced sponge clots. In D7, none of the samples presented bacterial growth, 20 (66,7%) did not clot and 10 (33,3%) produced sponge clots. Mesophilic bacterial culture was not done. The A brand UHT process did not grant sterilization regarding psychrotrophic bacteria, and the milk clotting results indicate possible coliforms contamination in both brands. Furthermore, clot absence in several samples could indicate preservatives usage, which is considered fraud.(AU)


Assuntos
Leite/química , Leite/fisiologia , Temperatura Alta , Técnicas Microbiológicas , Técnicas Microbiológicas
11.
Epidemiol. serv. saúde ; 30(3): e20201017, 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1286360

RESUMO

Objetivo: Descrever a adequação da conservação de imunobiológicos nas salas de imunização dos municípios da macrorregião de saúde Oeste do estado de Minas Gerais, Brasil. Métodos: Estudo descritivo, pautado em uma escala validada, com escore máximo de 15 pontos. Realizou-se análise descritiva e teste de associação entre os escores obtidos pelos municípios e variáveis do contexto externo. Resultados: Foram avaliadas 275 do total de 295 salas de imunização existentes. A conservação de imunobiológicos na macrorregião Oeste obteve um escore médio de 4 pontos (escore-padrão de 0 a 15). Evidenciou-se ausência ou carência de insumos destinados à conservação de imunobiológicos, e processos de trabalho que requerem aprimoramento. Municípios de pequeno porte apresentaram melhor conservação de imunobiológicos (p=0,011). Conclusão: A conservação de imunobiológicos nas salas de imunização da macrorregião de saúde Oeste de Minas Gerais foi considerada inadequada.


Objetivo: Describir la adecuación de la conservación de inmunobiológicos en las salas de inmunización de la macrorregión Oeste de Minas Gerais, Brasil. Métodos: Estudio descriptivo a partir de una escala validada con una puntuación máxima de 15 puntos. Se realizaron análisis descriptivos y pruebas de asociación entre las puntuaciones obtenidas por los municipios y las variables del contexto externo. Resultados: Se evaluaron 275 de un total de 295 salas de vacunación. La conservación de los inmunobiológicos en la macrorregión Oeste obtuvo una puntuación promedio de 4 puntos (4/15). Se evidenció la ausencia o falta de insumos para la conservación de inmunobiológicos y procesos de trabajo que requieren ser mejorados. Los municipios pequeños presentaron una mejor conservación de los inmunobiológicos (p=0,011). Conclusión: La conservación inmunobiológica en las salas de vacunación de la macrorregión Oeste de Minas Gerais fue considerada inadecuada.


Objective: To describe the adequacy of immunobiological agent conservation in vaccination rooms in the municipalities of the Western health macro-region of the state of Minas Gerais, Brazil. Methods: This was a descriptive study, based on a validated scale, with a maximum score of 15 points. A descriptive analysis and an association test between the scores obtained by the municipalities and variables of the external context were performed. Results: 275 out of a total of 295 existing vaccination rooms were evaluated. Immunobiological agent conservation in the West macro-region obtained an average score of 4 points (standard score, 0 to 15). There was a poor availability of immunization supplies aimed at immunobiological agent conservation, and work processes, that require improvement. Small municipalities presented better immunobiological agent conservation (p=0.011). Conclusion: Immunobiological agent conservation in vaccination rooms in the Western health macro-region of Minas Gerais State was considered inadequate.


Assuntos
Humanos , Vacinas/provisão & distribuição , Imunização/instrumentação , Refrigeração/instrumentação , Brasil
12.
Rev. bras. enferm ; Rev. bras. enferm;74(1): e20190762, 2021. tab, graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-1155944

RESUMO

ABSTRACT Objectives: to analyze vaccine losses in a Health Region in the Northwest of São Paulo. Methods: retrospective cross-sectional study with secondary data obtained from Temperature Change Notification Forms used by the Epidemiological Surveillance Group XXIX of São José do Rio Preto between 2010 and 2017. Descriptive and inferential analysis were performed using multiple linear regression and significance level of 95%. Results: in total, 341 notifications of temperature changes were analyzed, of which 70.1% were caused by structural reasons, 57.8% in industrial refrigerators and 91.2% in primary care services. Of the doses that suffered a change in temperature, 41.4% were lost and 58.6% were administered to the population. The highest percentage of lost doses compared to those applied occurred in smaller municipalities, although they reported less. Conclusions: nursing workers who work in vaccination rooms should make efforts to prevent temperature changes and avoid losses and higher public expenses.


RESUMEN Objetivos: analizar las pérdidas de vacunas en una Región de Salud del Noroeste de São Paulo. Métodos: estudio transversal retrospectivo, con datos secundarios obtenidos de los formularios de notificación de cambios de temperatura utilizados por el Grupo XXIX de Vigilancia Epidemiológica de São José do Rio Preto entre 2010 y 2017. Se realizó el análisis descriptivo e inferencial y se utilizó la regresión lineal múltiple y nivel de significancia del 95%. Resultados: se analizaron 341 notificaciones de cambios de temperatura, de las cuales el 70,1% fueron por motivos estructurales, el 57,8% en frigoríficos industriales y el 91,2% en los servicios de atención primaria. De las dosis que sufrieron un cambio de temperatura, el 41,4% se perdieron y el 58,6% se administraron a la población. El mayor porcentaje de dosis perdidas en comparación con las aplicadas se produjo en los municipios más pequeños, aunque informaron menos. Conclusiones: los trabajadores de enfermería que laboran en las salas de vacunación deben esforzarse por prevenir cambios de temperatura, evitando pérdidas y aumento de los gastos públicos.


RESUMO Objetivos: analisar as perdas de vacinas em uma Região de Saúde do Noroeste paulista. Métodos: estudo transversal retrospectivo, com dados secundários obtidos das fichas de notificação de alteração de temperatura utilizadas pelo Grupo de Vigilância Epidemiológica XXIX de São José do Rio Preto, entre 2010 e 2017. Foi realizada análise descritiva e inferencial, utilizando regressão linear múltipla e nível de significância de 95%. Resultados: foram analisadas 341 notificações de alteração de temperatura, sendo 70,1% causadas por motivos estruturais, 57,8% em refrigeradores industriais e 91,2% em serviços de atenção básica. Das doses que sofreram alteração de temperatura, 41,4% foram perdidas e 58,6% foram administradas na população. O maior percentual de doses perdidas em relação às aplicadas ocorreu em municípios menores, apesar de eles notificarem menos Conclusões: os trabalhadores de enfermagem que atuam em salas de vacinação devem se empenhar para prevenir alterações de temperatura, evitando perdas e aumento dos gastos públicos.


Assuntos
Humanos , Vacinas , Temperatura , Brasil , Vacinas/efeitos adversos , Estudos Transversais , Estudos Retrospectivos , Cidades
13.
Saúde Pesqui. (Online) ; 13(3): 475-483, jul.-set. 2020.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1140633

RESUMO

O objetivo deste trabalho éavaliar a qualidade da conservação das vacinas em Unidades da Atenção Primária à Saúde em uma capital do Nordeste brasileiro. Trata-se de um estudo descritivo e avaliativo, transversal, com abordagem quantitativa. Aplicou-se parte do instrumento PAISSV 2.0 do Programa Nacional de Imunização, com profissionais da enfermagem entre agosto de 2016 e janeiro de 2017. Utilizou-se análise estatística descritiva. Avaliou-se 48 (92,3%) salas de vacinas. Na dimensão estrutura, destaca-se a ausência de câmaras refrigeradas e de instrumentos de monitoramento e controle da temperatura em 100% das salas avaliadas. Quanto ao processo de conservação, evidenciou-se que nenhuma das salas realizava a distribuição das vacinas nas prateleiras, conforme recomendações técnicas. 43 (89,6%) salas foram classificadas como não adequadas e nenhuma considerada adequada. A prática da conservação de vacinas ainda é incipiente, com inadequação da estrutura e processo de trabalho. Estas lacunas podem comprometer a erradicação e o controle das doenças imunopreveníveis.


The preservation of vaccines in Primary Health Care units in São Luís, a capital city in northeastern Brazil, is evaluated. Current descriptive, evaluative, cross-sectional quantitative approach was applied to a section of PAISSV 2.0 of the National Immunization Program with nursing professionals, between August 2016 and January 2017. Descriptive statistical analysis was employed. Forty-eight (92.3%) vaccine rooms were assessed. The complete absence of refrigerated chambers and the lack of monitoring and control instruments for temperature may be highlighted. In the case of the conservation process, not a single vaccine room distributed vaccines on shelves as recommended. Further, 43 vaccine rooms (89.6%) were classified as unsuitable and all were inappropriate. The vaccine conservation practice is still incipient, with inadequate structure and working process. These flaws may compromise the eradication and control of immunopreventive diseases.

14.
Arq. bras. med. vet. zootec. (Online) ; 72(5): 1989-1992, Sept.-Oct. 2020.
Artigo em Português | LILACS, VETINDEX | ID: biblio-1131572

RESUMO

The morphological characteristics of the autologous platelet concentrate (APC) of 31 dogs were evaluated after cooling and freezing in 6% DMSO. Blood from the jugular vein of each patient was collected and centrifuged at 191g for six minutes to obtain APC. In the fresh sample, the platelet count, MPV, PDW and cell morphology were evaluated. Four samples of each animal were sent for storage, one refrigerated at 4°C for seven days, another for 30 days and two more stored in a freezer at -80°C in the same time interval, using 6% DMSO as cryoprotectant. The conserved samples were submitted to the same laboratory analysis as the fresh sample. There was a difference between fresh and preserved samples for platelet count, cell concentration, MPV and PDW (P<0.05), except in the 30-day refrigerated group, which showed severe morphological changes. In the frozen group for seven days, no difference was observed in the percentage of activation (P>0.05). The results obtained lead to the conclusion that cryopreservation with 6% DMSO at -80°C for seven days is a favorable option for the maintenance of platelet concentrations and the morphological characteristics of APC in dogs.(AU)


Assuntos
Animais , Cães , Refrigeração , Criopreservação , Plasma Rico em Plaquetas/citologia , Dimetil Sulfóxido
15.
Av. enferm ; 38(2): 170-181, May-Aug. 2020. tab, graf
Artigo em Inglês | COLNAL, BDENF - Enfermagem, LILACS | ID: biblio-1114687

RESUMO

Abstract Objective: To develop and to test the validity of content and layout of a multidimensional tool to evaluate maintenance of the cold chain for immunobiological conservation. Method: A methodological study carried out in three steps: integrative review; development of theoretical and logical model for the development of the tool; implementation of the Delphi Technique to test the validity of content and layout. The Content Validity Index (CVI) and Content Validity Ratio (CVR) were calculated considering appropriate those values greater than or equal to 75% and 0.4, respectively. Results: The instrument consisted of 7 questions about structure and 20 about process, subdivided into three components: Transportation/Reception (n=3); Storage/Handling (n=13); Supervision/Permanent education (n=4). The cvi value was 87.4%, with values equal to 85.7% and 89% in the structure and process dimensions, respectively. The process components obtained cvi values equal to 88.9, 88.9 and 89.2%, respectively. The CVR was 0.8, with values equal to 0.7 and 0.8 in the structure and process dimensions. As for the layout validation, the questionnaire was considered intelligible. Conclusion: The study provides an instrument with validity of content and layout for health professionals in charge of the supervision of activities of immunobiological conservation, ensuring the maintenance of the immunogenic quality of the products offered to the population.


Resumen Objetivo: desarrollar y validar los contenidos e interface de una herramienta multidimensional para evaluar el mantenimiento de la cadena de frío de la conservación inmunobiológica. Método: estudio metodológico realizado en tres pasos: revisión integradora; elaboración de modelo teórico y lógico para el desarrollo de la herramienta; implementación de la técnica Delphi para la validación de contenido y de apariencia de preguntas. Se calcularon el Índice de validez de contenido (IVC) y el Razón de Validez de Contenido (RVC), considerando apropiados aquellos valores mayores o iguales al 75 % y 0,4, respectivamente. Resultados: el cuestionario constaba de siete preguntas de estructura y 20 de proceso, subdivididas en tres componentes: Transporte/Recepción (n=3); Almacenamiento/Manipulación (n=13); Supervisión/Educación continua (n=4). El valor para el cvi fue 87,4 %, con valores iguales al 85,7 y 89 % en las dimensiones estructura y proceso, respectivamente. Los componentes del proceso obtuvieron valores para el IVC iguales a 88,9, 88,9 y 89,2 %, respectivamente. El RVC era una herramienta de 0,8, con valores iguales a 0,7 en la estructura de dimensión y 0,8 en proceso. En cuanto a la validación de la apariencia, el cuestionario se consideró inteligible. Conclusión: el estudio proporciona un instrumento con contenido validado para profesionales de la salud, en la supervisión de actividades de conservación de productos inmunobiológicos, asegurando el mantenimiento de la calidad inmunogénica de los productos ofrecidos a la población.


Resumo Objetivo: desenvolver e validar o conteúdo e interface de um instrumento multidimensional para avaliar a manutenção da cadeia de frio de conservação de imunobiológicos. Método: estudo metodológico realizado em três etapas: revisão integrativa; elaboração do modelo teórico-lógico para o desenvolvimento do instrumento; realização da Técnica Delphi para validar conteúdo e aparência das questões. Foram calculados o Índice de Validade de Conteúdo (IVC) e a Razão de Validade de Conteúdo (RVC), considerando-se valores adequados aqueles maiores ou iguais a 75 % e 0,4, respectivamente. Resultados: o questionário constou de sete questões de estrutura e 20 de processo, subdivididos em três componentes: transporte/recebimento (n=3); armazenamento/manuseio (n=13); supervisão/educação permanente (n=4). O valor para o IVC foi de 87,4 %, com valores iguais a 85,7 % na dimensão estrutura e 89 % no processo. Os componentes do processo obtiveram valores para o IVC iguais a 88,9 %, 88,9 % e 89,2 %, respectivamente. O RVC do instrumento foi de 0,8, com valores iguais a 0,7 na dimensão estrutura e 0,8 no processo. Quanto à validação de aparência, o questionário foi considerado inteligível. Conclusão: o estudo fornece um instrumento de medida com conteúdo validado e que se configura em uma ferramenta de gestão útil na supervisão de salas de imunização.


Assuntos
Humanos , Refrigeração , Vacinas , Avaliação de Programas e Projetos de Saúde , Estudo de Validação , Equipamentos e Provisões
16.
ABCS health sci ; 45: [1-6], 02 jun 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1097547

RESUMO

INTRODUCTION: Immunobiologicals are of great importance for the prevention and eradication of diseases. However, the lack of maintenance of the cold chain generates several problems related to losses of these substances, burdening an important amount of public resources. OBJECTIVE: To analyze vaccine losses in a Health Region (Região Ampliada de Saúde Oeste) of Minas Gerais State in Brazil. METHODS: This is a descriptive study, based on secondary data obtained through forms used by the regional health agency (Superintendência Regional de Saúde, SRS), to register losses of immunobiologicals due to temperature changes. Forms from February 2016 through January 2018 were analyzed. The data was organized and validated by double typing. RESULTS: Vaccine losses were caused by lack of electrical energy (40.83%), followed by equipment failure (36.67%), and professional error (10%). As a consequence, 17,229 bottles of vaccines (65.78%) were discarded, corresponding to 111,145 doses. The financial loss was R$ 604,340.31. CONCLUSION: Losses of vaccines due to temperature changes were relevant in the studied region, damaging the budget for the local health network. Therefore, it is suggested that measures to minimize these losses should be adopted.


INTRODUÇÃO: Os imunobiológicos são de grande importância para a prevenção e erradicação de doenças. Entretanto, a falta de manutenção da Rede de Frio gera diversos problemas relacionados a perdas dessas substâncias, onerando uma importante quantia de recursos públicos. OBJETIVO: Analisar as perdas vacinais da Região Ampliada de Saúde Oeste de Minas Gerais. MÉTODOS: Trata-se de um estudo descritivo, com base em dados secundários obtidos através de formulários utilizados pela Superintendência Regional de Saúde (SRS), para avaliação de perdas de imunobiológicos por alteração de temperatura. Foram analisados os formulários de fevereiro de 2016 até janeiro de 2018. Os dados foram organizados e validados por dupla digitação, e a análise foi feita descritivamente. RESULTADOS: Os resultados mostraram que dos motivos das ocorrências 40,83% foram por falta de energia elétrica, seguida de falha no equipamento (36,67%), e erro do profissional (10%). Foram inutilizados 17229 frascos de vacinas (65,78%), sendo 111.145 doses, com uma perda financeira de R$ 604.340,31. CONCLUSÃO: Identificou-se que as perdas físicas por alteração de temperatura de vacinas na região estudada foram relevantes, gerando prejuízos para o orçamento do SUS. Dessa forma sugere-se a adoção de condutas para minimizar estas perdas.


Assuntos
Refrigeração , Temperatura , Vacinas/provisão & distribuição
17.
Pesqui. vet. bras ; 40(4): 306-314, Apr. 2020. tab
Artigo em Inglês | VETINDEX | ID: vti-29467

RESUMO

The objective of this study was to evaluate the sperm quality obtained of domestic cats by electroejaculation and recovery of the tail of the epididymis after cooling at -1°C and 4°C for 24 and 48 hours. Twenty-nine adult cats (2 to 6kg) were used. Sperm collection was performed by electroejaculation (EEJ), and after 48 hours, the cats were orchiectomized, and sperm sample was obtained from the vas deferens and epididymis tail (EPD). The samples were diluted in ACP-117® extender, and the sperm characteristics were evaluated at three different moments: when still fresh, 24 and 48 hours after cooling. The objective of this study was to evaluate the sperm quality obtained of domestic cats by electroejaculation and recovery of the tail of the epididymis after cooling at -1°C and 4°C for 24 and 48 hours. Twenty-nine adult cats (2 to 6kg) were used. Sperm collection was performed by electroejaculation (EEJ), and after 48 hours, the cats were orchiectomized, and sperm sample was obtained from the vas deferens and epididymis tail (EPD). The samples were diluted in ACP-117® extender, and the sperm characteristics were evaluated at three different moments: when still fresh, 24 and 48 hours after cooling. In order to compare the two refrigeration temperatures, the first stage was to analyze if there was a difference between the harvesting techniques. After this, two experiments were conducted: in the first, sperm sample from 14 cats were used and the cooling was performed at -1°C; and in the second, sample from 15 cats were used and the sperm were refrigerated at 4°C. Sperm kinetics were evaluated by computerized analysis (CASA) and concentration by Neubauer chamber, spermatic morphology was evaluated by modified Karras staining, and membrane integrity was evaluated by eosin nigrosine. The results obtained were analyzed in R software, version 3.2.5 using the Mann-Whitney test for variables with abnormal distributions, considering significance at the level of 5%...(AU)


O objetivo deste trabalho foi avaliar a qualidade espermática de gatos domésticos obtidos por eletroejaculação e recuperação da cauda do epidídimo após a refrigeração a -1°C e a 4°C por 24 e 48 horas. Vinte e nove gatos adultos (2 a 6kg) foram utilizados. A colheita de espermatozoides foi realizada por eletroejaculação (EEJ) e, após 48 horas, os gatos foram orquiectomizados, e as amostras espermáticas foram obtidas a partir do ducto deferente e da cauda do epidídimo (EPD). As amostras foram diluídas em ACP-117® e as características espermáticas foram avaliadas em três momentos distintos: fresco, 24 e 48 horas após a refrigeração. Para ser possível comparar as duas temperaturas de refrigeração, a primeira etapa foi analisar se havia diferença entre as técnicas de colheita. Após isto, dois experimentos foram conduzidos: no primeiro, espermatozoides de 14 gatos foram utilizados e a refrigeração foi realizada a -1°C; e no segundo, amostras de 15 gatos foram utilizados e os espermatozoides foram refrigerados a 4°C. A cinética espermática foi avaliada por análise computadorizada (CASA), a concentração por câmara de Neubauer, a morfologia espermática foi avaliada pela coloração de Karras modificada, e a integridade da membrana foi avaliada por eosina nigrosina. Os resultados obtidos foram analisados no software R, versão 3.2.5, utilizando o teste de Mann-Whitney para variáveis com distribuições anormais, considerando significância ao nível de 5%...(AU)


Assuntos
Animais , Masculino , Gatos , Sêmen , Preservação do Sêmen/veterinária , Espermatozoides , Criopreservação , Técnicas de Reprodução Assistida , Técnicas de Reprodução Assistida/veterinária , Epididimo
18.
Pesqui. vet. bras ; Pesqui. vet. bras;40(4): 306-314, Apr. 2020. tab
Artigo em Inglês | VETINDEX, LILACS | ID: biblio-1135625

RESUMO

The objective of this study was to evaluate the sperm quality obtained of domestic cats by electroejaculation and recovery of the tail of the epididymis after cooling at -1°C and 4°C for 24 and 48 hours. Twenty-nine adult cats (2 to 6kg) were used. Sperm collection was performed by electroejaculation (EEJ), and after 48 hours, the cats were orchiectomized, and sperm sample was obtained from the vas deferens and epididymis tail (EPD). The samples were diluted in ACP-117® extender, and the sperm characteristics were evaluated at three different moments: when still fresh, 24 and 48 hours after cooling. The objective of this study was to evaluate the sperm quality obtained of domestic cats by electroejaculation and recovery of the tail of the epididymis after cooling at -1°C and 4°C for 24 and 48 hours. Twenty-nine adult cats (2 to 6kg) were used. Sperm collection was performed by electroejaculation (EEJ), and after 48 hours, the cats were orchiectomized, and sperm sample was obtained from the vas deferens and epididymis tail (EPD). The samples were diluted in ACP-117® extender, and the sperm characteristics were evaluated at three different moments: when still fresh, 24 and 48 hours after cooling. In order to compare the two refrigeration temperatures, the first stage was to analyze if there was a difference between the harvesting techniques. After this, two experiments were conducted: in the first, sperm sample from 14 cats were used and the cooling was performed at -1°C; and in the second, sample from 15 cats were used and the sperm were refrigerated at 4°C. Sperm kinetics were evaluated by computerized analysis (CASA) and concentration by Neubauer chamber, spermatic morphology was evaluated by modified Karras staining, and membrane integrity was evaluated by eosin nigrosine. The results obtained were analyzed in R software, version 3.2.5 using the Mann-Whitney test for variables with abnormal distributions, considering significance at the level of 5%. In ejaculate samples, higher values of total morphological defects were observed after 24 and 48 hours of refrigeration at 4°C (P<0.022) compared to refrigeration at -1°C, using Friedman test. To quantify the decrease in sperm quality, parameter reductions were calculated among time points (F-24h/F-48h/24h-48h). In EPD samples, a greater reduction in sperm quality was detected after 24 hours of refrigeration at 4°C, both in motility and sperm kinetics and in the movement and velocity indices, compared to refrigeration at -1°C. Based on the results, it can be concluded that cooling of feline spermatozoa at -1°C for up to 48 hours was efficient in maintaining spermatic quality collected by EEJ and EPD, and it could be an alternative to spermatozoa cryopreservation in domestic felines.(AU)


O objetivo deste trabalho foi avaliar a qualidade espermática de gatos domésticos obtidos por eletroejaculação e recuperação da cauda do epidídimo após a refrigeração a -1°C e a 4°C por 24 e 48 horas. Vinte e nove gatos adultos (2 a 6kg) foram utilizados. A colheita de espermatozoides foi realizada por eletroejaculação (EEJ) e, após 48 horas, os gatos foram orquiectomizados, e as amostras espermáticas foram obtidas a partir do ducto deferente e da cauda do epidídimo (EPD). As amostras foram diluídas em ACP-117® e as características espermáticas foram avaliadas em três momentos distintos: fresco, 24 e 48 horas após a refrigeração. Para ser possível comparar as duas temperaturas de refrigeração, a primeira etapa foi analisar se havia diferença entre as técnicas de colheita. Após isto, dois experimentos foram conduzidos: no primeiro, espermatozoides de 14 gatos foram utilizados e a refrigeração foi realizada a -1°C; e no segundo, amostras de 15 gatos foram utilizados e os espermatozoides foram refrigerados a 4°C. A cinética espermática foi avaliada por análise computadorizada (CASA), a concentração por câmara de Neubauer, a morfologia espermática foi avaliada pela coloração de Karras modificada, e a integridade da membrana foi avaliada por eosina nigrosina. Os resultados obtidos foram analisados no software R, versão 3.2.5, utilizando o teste de Mann-Whitney para variáveis com distribuições anormais, considerando significância ao nível de 5%. No ejaculado, maiores valores de defeitos morfológicos totais foram observados após 24 e 48 horas de refrigeração a 4°C (P<0,022) em comparação com refrigeração a -1°C, usando o teste de Friedman. Para quantificar a diminuição na qualidade espermática, as reduções dos parâmetros foram calculadas entre os pontos de tempo (F-24h/F-48h/24h-48h). Na EPD, uma maior redução na qualidade espermática foi detectada após 24 horas de refrigeração a 4°C, tanto na motilidade e na cinética espermática quanto nos índices de movimento e velocidade, em comparação com a refrigeração a -1°C. Com base nos resultados, pode concluir-se que a refrigeração dos espermatozoides felino a -1°C, até 48 horas, foi eficaz na manutenção da qualidade espermático colhidos por EEJ e EPD, e pode ser uma alternativa para a criopreservação de espermatozoides em felinos domésticos.(AU)


Assuntos
Animais , Masculino , Gatos , Sêmen , Preservação do Sêmen/veterinária , Espermatozoides , Criopreservação , Técnicas de Reprodução Assistida , Técnicas de Reprodução Assistida/veterinária , Epididimo
19.
Ciênc. anim. bras. (Impr.) ; 21: e, 23 mar. 2020. tab
Artigo em Português | VETINDEX | ID: biblio-1473737

RESUMO

Dois experimentos foram realizados para verificar a viabilidade de diluentes para sêmen equino refrigerado. O objetivo do primeiro experimento foi verificar a eficiência do leite UHT integral e semidesnatado, comparado ao leite desnatado. Amostras foram analisadas a fresco e posteriormente diluídas em leite UHT integral, semidesnatado e desnatado. Foram realizados exames de motilidade espermática e vigor, CFDA/PI e HOST pós-diluição (0h), e no sêmen refrigerado a 5 ºC após 24 e 48 horas. Não houve diferença entre os três diluentes, quanto à motilidade espermática (p=0,9880), vigor (p=0,7249), CFDA/PI (p=0,3382) e HOST (p > 0,01). Houve uma diminuição na qualidade do sêmen, no decorrer do tempo (p < 0,01), independente do diluente utilizado. Pode-se afirmar que, na falta de leite UHT desnatado, o semidesnatado e o integral podem ser usados, uma vez que eles não provocam prejuízo na qualidade do sêmen refrigerado armazenado por até 48 horas. No segundo experimento, o objetivo foi verificar a eficácia do leite desnatado em comparação com diluentes comerciais (Botusemen® (BS) e Botusemen Special® (BSS)). Logo após a coleta do sêmen, as amostras foram diluídas com leite UHT desnatado (LD), Botusemen® (BS) e Botusemen Special®(BSS). A análise de sêmen seguiu o mesmo protocolo do primeiro experimento. As amostras de sêmen refrigeradas com BSS apresentaram HOST e CFDA/PI (p< 0,001) maiores nas 24h e 48 h o que indica que o diluente BSS promove aumento da longevidade dos espermatozoides em comparação com os outros analisados.


Two trials were performed to verify the viability of extenders equine cooled semen. The objective of the first trial was to verify the efficacy of whole and semi-skimmed UHT milk compared to skim milk. Fresh semen samples were analyzed and later diluted in UHT whole milk, semi skimmed and skimmed milk. Sperm motility and vigor, CFDA / PI and HOST tests were performed post-dilution (0h), and in semen cooled at 5oC after 24 and 48h. There was no difference between the 3 extenders, for sperm motility (p = 0.9880), vigor (p = 0.7249), CFDA / PI (p = 0.3882) and HOST (p> 0.01). There was a decrease in semen quality over time (p <0.01), regardless of the extender used. It can be stated that in the absence of skimmed UHT milk, semi-skimmed and whole milk can be used since they do not impair the quality of refrigerated semen stored for up to 48 hours. In the second trial the objective was to verify the efficacy of the skim milk compared to commercial extenders (Botusemen® (BS) and Botusemen Special® (BSS)). Soon after semen collection, the samples were diluted with UHT skim milk (LD), Botusemen® (BS) and Botusemen Special® (BSS). Semen analysis followed the same protocol as the first experiment. BSS-cooled semen showed higher HOST and CFDA / PI (p <0.001) in 24h and 48h indicating that BSS diluent promotes increased sperm longevity compared to the others analyzed.


Assuntos
Masculino , Animais , Cavalos , Diluição , Leite/química , Preservação do Sêmen/métodos , Preservação do Sêmen/veterinária
20.
Ciênc. anim. bras. (Impr.) ; 21: e, 23 mar. 2020. tab
Artigo em Português | VETINDEX | ID: biblio-1473741

RESUMO

Considerando os diversos problemas tecnológicos e econômicos que os microrganismos deteriorantes acarretam aos laticínios, o objetivo deste trabalho foi quantificar aeróbios mesófilos, psicrotróficos, termodúricos e esporulados no leite cru produzido na região Norte do Paraná e verificar a capacidade proteolítica e lipolítica desses microrganismos. Foram analisadas 20 amostras de leite cru e determinadas contagens de aeróbios mesófilos, psicrotróficos, termodúricos mesófilos, termodúricos psicrotróficos e esporos aeróbios e o perfil proteolítico e lipolítico de cada grupo. A contagem média de aeróbios mesófilos foi de 1,7x106UFC/mL acima do limite estabelecido pela Instrução Normativa 76 (3,0x105UFC/mL); 55% das amostras apresentaram contagens dentro dos padrões. As contagens de psicrotróficos variaram de 1,0x102 a 9,9x106UFC/mL e em 30% das amostras esse valor foi superior ao de mesófilos. A média de termodúricos mesófilos foi de 2,4x104UFC/mL, de termodúricos psicrotróficos 1,7x102UFC/mL e de esporos aeróbios foi de 5,0x101UFC/mL. Quanto ao perfil deteriorante, todos os grupos apresentaram atividade lipolítica e proteolítica elevadas, com predomínio de bactérias lipolíticas. Os valores encontrados indicam que o manejo higiênico-sanitário inadequado durante a ordenha e o resfriamento prolongado favorece a proliferação da microbiota deteriorante, que pode promover alterações significativas na qualidade e no rendimento do leite e seus derivados, mesmo após tratamento térmico.


Considering that technological problems and economic losses are basically caused by spoilage microorganisms on dairy industry, therefore the aim of this study was to quantify the mesophilic aerobic, psychrotrophic, thermoduric and aerobic spore-forming in raw milk produced in northern Paraná and also verify the proteolytic and lipolytic capacity of these microorganisms. Twenty samples of raw milk were analyzed and were determined mesophilic aerobic, psychrotrophic, thermoduric mesophilic, psychrotrophic thermoduric and aerobicspore-forming counts and proteolytic and lipolytic capacity from each group. The average counts of aerobic mesophilic were 1,79x106CFU/mL, above the limit established to Normative Instruction 76 (3,0x105CFU/mL); 55% samples had scores within the standards. Psychrotrophic counts ranged from 1,0x102 to 9,9x106CFU/mL and in 30% samples this count was higher than mesophilic. The average mesophilic thermoduric was 2,4x104CFU/mL, psychrotrophic thermoduric was 1,7x102CFU/mL and aerobic spore-forming was 5,0x101CFU/mL. As for the spoilage profile, all groups showed higher lipase and proteolytic activity, with a predominance of lipolytic bacteria. The values found indicates the inappropriate hygienic-sanitary management during milking and maintaining molk refrigerated for long periods until pasteurize, it can favorsthe proliferation of spoilage microbiota, which can promote significant changes in the quality and yield of milk and dairy products, even after the heat treatment.


Assuntos
Alimentos Crus , Alimentos Resfriados , Contaminação de Alimentos/análise , Leite/microbiologia , Microbiota , Lipólise , Proteólise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA