Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Assunto principal
Intervalo de ano de publicação
1.
BMC Res Notes ; 14(1): 229, 2021 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-34090484

RESUMO

OBJECTIVE: To present the Pain-Track, a novel framework for the description and analysis of the pain experience based on its temporal evolution, around which intensity and other attributes of pain (texture, anatomy), interventions and clinical symptoms can be registered. This time-series approach can provide valuable insight on the expected evolution of the pain typically associated with different medical conditions and on time-varying (risk) factors associated with the temporal dynamics of pain. RESULTS: We illustrate the use of the framework to explore hypotheses on the temporal profile of the pain associated with an acute injury (bone fracture), and the magnitude of the pain burden it represents. We also show that, by focusing on the critical dimensions of the pain experience (intensity and time), the approach can help map different conditions to a common scale directly relating to the experiences of those who endure them (time in pain), providing the basis for the quantification of the burden of pain inflicted upon individuals or populations. An electronic version for data entry and interpretation is also presented.


Assuntos
Dor , Humanos , Medição da Dor
2.
Int J Spine Surg ; 9: 30, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26273548

RESUMO

BACKGROUND: Cervical disc arthroplasty has become a technique for the treatment of cervical degenerative disc disease. Clinically, the need to accurately assess the neural elements at the operative and adjacent levels is critical postoperatively. The purpose of this study was to quantitatively and qualitatively measure the amount of MRI artifact produced by various cervical total disc replacements. METHODS: T1 and T2-weighted turbo spin-echo MRI sequences were collected on the cervical spine (C2-T1) of a 68 year-old unembalmed male cadaver. A discectomy was performed at C5-6, followed by successive implantation of six different total disc replacements. The scans were quantitatively evaluated by three of the authors. The volume of artifact was measured using image analysis software. Qualitative analysis of the adjacent and index neural elements was performed. RESULTS: The artifact in the T2 weighted images was noted to be 58.6±7.3 cm3 for Prestige ST, 14.2±1.3 cm3 for ProDisc-C, 7.5±0.8 cm3 for Discover, 8.0±0.3 cm3 for Prestige LP, 6.6±0.7 cm3 for Bryan, and 7.3±0.6 cm3 for ProDisc-C titanium prototype. Acceptable intraobserver and excellent interobsever correlation was demonstrated using Pearson Correlation and Concordance Correlation Coefficient analysis. The adjacent and implanted level neural elements (spinal cord and neuroforamina) were easily visualized on the T2 weighted images after the implantation of titanium devices (ProDisc-C titanium prototype, Discover, Prestige LP and Bryan). After implantation of a cobalt chrome implant (ProDisc-C), the adjacent level neural elements were easily visualized but the implanted level could not be fully visualized due to distortion of the images. The quality of the distortion was least favorable after the implantation of the stainless steel implant (Prestige ST), where neither the adjacent nor the index level could be fully visualized. CONCLUSION: The volume of the artifact seen following cervical total disc arthroplasty is highly dependent upon the material property of the implant. Quantitative analysis described in this study demonstrated sufficiently low intraobserver and interobserver variability to be considered a reliable technique.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA