Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
JSES Int ; 8(2): 257-267, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38464441

RESUMO

Background: Clavicle fractures are among the most common upper limb fractures in adults, with the midshaft region being the most frequently affected site. Minimally invasive plate osteosynthesis (MIPO) has emerged as an alternative to the traditional open reduction and internal fixation (ORIF) technique, offering potential advantages. The purpose of this study was to conduct a systematic review to explore the results of this technique in the existing literature, with emphasis on the occurrence of surgical complications and functional outcomes and also to provide a comprehensive comparison of MIPO and ORIF in the management of midshaft clavicle fractures. Methods: We conducted a systematic review to evaluate the complication incidence and clinical outcomes of MIPO for midshaft clavicle fractures. We searched PubMed/Medical Literature Analysis and Retrieval System Online (MEDLINE), Scopus, the Cochrane Database of Controlled Trials, and the Cochrane Database of Systematic Reviews databases without language or date restrictions. Studies focusing on midshaft clavicle fractures treated with MIPO were included, while other clavicle fractures and nonclinical studies were excluded. The risk of bias was assessed using the Methodological Index for Nonrandomized Studies criteria and the Risk of Bias Tool 2 Cochrane tool. Data synthesis included qualitative analysis, and if applicable, quantitative analysis and meta-analysis. Adherence to Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines ensured reporting quality. Results: A total of 107 studies were initially identified, after applying inclusion and exclusion criteria, 22 studies were included for data extraction. These studies involved the evaluation of 714 clavicles treated with the MIPO technique. Of the 714 MIPO cases, 11 cases of implant failure, 5 nonunions, 2 infections, and 28 cases with neurological impairment were observed. Quantitative analysis comparing MIPO with ORIF revealed that MIPO had significantly shorter surgery time (mean difference -12.95, 95% confidence interval [-25.27 to -0.63], P = .04) and lower occurrence of numbness (odds ratio 0.29, 95% CI [0.15-0.56], P = .0002) compared to ORIF. Time to bone union, functional outcomes, and other complications were similar between MIPO and ORIF at the final follow-up. An overall moderate risk of bias was found across the studies. Conclusion: The MIPO technique yields good and comparable results to ORIF for midshaft clavicle fractures. Additionally, the MIPO technique may offer advantages such as reduced surgical time and lower chances of neurological impairment.

2.
JSES Rev Rep Tech ; 4(1): 53-60, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38323209

RESUMO

Background: Open reduction and internal fixation with plate is one of the most widely used treatments for distal third humeral shaft fractures. The purpose of this study was to report the outcomes of the treatment of distal third humeral shaft fractures with posterior minimally invasive plate osteosynthesis (MIPO) with segmental isolation of the radial nerve. Methods: We performed an observational, retrospective, consecutive, monocentric, continuous multioperator study. We reviewed 22 distal third humeral shaft fractures treated with posterior MIPO in our institution with an extra-articular distal humerus plate from 2018 to 2021. Inclusion was limited to functionally independent patients with displaced fractures involving the junction of the middle and distal thirds of the humerus and minimum 12-month follow-up for implant removal. We assessed clinical outcomes including range of motion; QuickDASH score; Mayo Elbow Performance Score; and Constant-Murley score. Results: The average follow-up period of the sample was 31.7 ± 11.6 months (range, 15.7-51.3 months). The average elbow flexion and extension were 146.4° ± 7.3° (range, 120°-150°) and -0.7° ± 3.3° (range, -15° to 0°), respectively. The average shoulder anterior flexion, elevation, and abduction were 178.6° ± 3.6° (range, 170°-180°), 179.1° ± 2.9° (range, 170°-180°), and 140.9° ± 14.8° (range, 110°-160°), respectively. The average external rotation was 88.6° ± 6.4 (range, 65°-90°). The mean visual analog scale score for pain was 1.0 ± 1.6 (range, 0-5) and the mean Mayo Elbow Performance Score was 90.5 ± 9.9 (range, 70-100). The mean QuickDASH and Constant-Murley scores were 4.7 ± 6.8 (range, 0-20.5) and 95.5 ± 5.1 (range, 81-100), respectively. Two patients presented with relevant compromise of radial nerve motor function postoperatively (M3 and M2; the more compromised was preoperative injury). All patients recovered radial nerve neuropraxia within six weeks postoperatively. All fractures achieved union. The average anteroposterior and lateral axis were 175.0 ± 3.6 (168.0°-180.0°) and 177.5 ± 2.0 (173.0°-180.0°), respectively. No superficial or deep infection was reported. No cases of re-displacement of fracture, implant failure, or any other implant-related complication in follow-up were reported. No patient required plate withdrawal. Conclusion: The results of this study demonstrate that the posterior MIPO technique is a reliable option for treating distal third shaft humeral fractures. The radial nerve must be identified and protected in all cases to prevent palsy.

3.
Arch Orthop Trauma Surg ; 143(11): 6955-6963, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37526738

RESUMO

INTRODUCTION: Scaphoid is the most fractured carpal bone, with a 5-10% nonunion rate. Treatment challenges include choosing the implant and graft that best corrects humpback deformity and carpal malalignment with higher chances of bony healing. OBJECTIVE: Compare cortico-cancellous and cancellous grafts between two groups of patients treating scaphoid nonunion with locking plates using autologous bone graft and evaluate bone healing rates and radiographic, tomographic, and functional parameters before and after surgery. METHODS: Non-randomized prospective study including 20 cases of scaphoid nonunion. Groups were divided into Group A (ten patients treated with cortico-cancellous iliac graft) and Group B (ten patients treated with cancellous iliac graft). Patients underwent pre- and postoperative radiographs, computed tomography, and functional evaluation. RESULTS: In postoperative analysis, Group A showed a statistically significant difference in intrascaphoid angle (p = 0.002) and scapholunate angle (p = 0.011) correction when comparing the pre- and postoperative periods. Group B showed a statistically significant difference in intrascaphoid angle (p = 0.002) and scapholunate angle correction (p = 0.0018), grip strength (p = 0.002), and tip pinch strength (p = 0.001) when comparing the pre- and postoperative periods. By comparing both groups, Group B showed a statistically significant difference in intrascaphoid angle correction (p = 0.002), grip strength (p = 0.002), tip pinch strength (p = 0.002), and radial deviation (p = 0.0003). There was no statistical difference when comparing bony healing between groups. CONCLUSION: Scaphoid nonunion treatment with a locking plate was effective, showing a high bony healing rate and improved carpal alignment in imaging tests for both graft types. However, results for intrascaphoid angle correction, grip strength, tip pinch strength, and radial deviation were better in Group B. LEVEL OF EVIDENCE: IV, case series.


Assuntos
Fraturas não Consolidadas , Pseudoartrose , Osso Escafoide , Humanos , Pseudoartrose/etiologia , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Fraturas não Consolidadas/etiologia , Estudos Prospectivos , Estudos Retrospectivos , Osso Escafoide/cirurgia , Fixação Interna de Fraturas/métodos , Transplante Ósseo/métodos
4.
Shoulder Elbow ; 14(6): 635-641, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36479015

RESUMO

Introduction: Fractures of the humeral shaft account for about 3% to 5% of all fractures. Although conservative treatment remains the first choice, there are a number of surgical indications. Minimally invasive plate osteosynthesis shows good functional results. However, complications have been reported, such as non-union. Objective: To assess the prevalence and risk factors for non-union after treatment of humeral shaft fractures using minimally invasive plate osteosynthesis. Materials and methods: This retrospective study was carried out in patients treated by minimally invasive plate osteosynthesis between 2009 and 2019. Demographic data and variables related to the fracture that could influence bone healing were analysed. The unpaired t-test and Mann-Whitney test were used for the statistical analyses. Categorical variables were analysed using the chi-square test or Fisher's exact test. Results: The study population showed a male predominance (53 of 75, 70.7%). The average time for fracture healing was 19.8 ± 15.3 weeks. Seven patients developed non-union. Only the presence of an open fracture increased the likelihood of non-union. Conclusions: The prevalence of non-union in patients treated by minimally invasive plate osteosynthesis was 9.3%. Patients with open fractures were six times more likely to progress to non-union. Fracture characteristics (Arbeitsgemeinschaft für Osteosynthesefragen classification, fracture location and plate working length) did not influence progression to non-union.

5.
JSES Int ; 6(6): 1015-1022, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36353432

RESUMO

Background: Safety zones to avoid nerve injury at proximal incision of posterior minimally invasive plate osteosynthesis for humerus fracture have been scarcely studied. The purpose of this study was to describe the location of axillary and radial nerves (RN) in magnetic resonance imaging to establish safety zones. Methods: Fifty-two magnetic resonance imaging studies of the entire humerus were reviewed. The mean age was 50.6 ± 12.1 years, with 37 female patients. The distance of the axillary nerve (AN; distal portion, humeral midpoint) and RN (medial border, midpoint, and lateral border of the humerus) was measured in relation to the posterolateral acromion angle, acromioclavicular axis, and transepicondylar axis. Univariate analysis (Student's t test) and a multivariate analysis (linear regression) were performed. P values < .05 were considered significant. Results: The AN location at the humerus was 54.9 ± 6.4 mm (20.1% humeral length [HL]) in relation to posterolateral acromion angle and 63.2 ± 6.1 mm (23.2% HL) in relation to acromioclavicular axis. The RN location was 100.2 ± 17.1 mm (36.6% HL) at the humerus medial border, 118.0 ± 21.5 mm (43.1% HL) at the humerus midpoint, and 146.0 ± 24.4 mm (53.6% HL) at the humerus lateral border. In relation to transepicondylar axis, it was 175.4 ± 15.6 mm (64.3% HL), 156.0 ± 19.0 mm (57.2% HL), and 127.4 ± 21.2 mm (46.7% HL), respectively. Nerves location was related to HL, independent of gender. Conclusion: The main finding of our study is that the location of the AN and RN in relation to the humerus is related to the HL and can be used to predictably define the safe zones to avoid nerve injury in the proximal incision of posterior minimally invasive plate osteosynthesis for humerus fractures.

6.
Acta ortop. mex ; 35(5): 479-485, sep.-oct. 2021. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1393812

RESUMO

Resumen: El tratamiento quirúrgico de las fracturas desplazadas del tercio medio de clavícula ha ganado popularidad durante la última década, ya que permite acortar el período de recuperación, acelerando la reincorporación laboral y deportiva, al mismo tiempo que disminuye significativamente el riesgo de no unión. Sin embargo, las molestias relacionadas con el abordaje cutáneo como dolor e irritación a nivel de la cicatriz, las alteraciones sensitivas persistentes (hipoestesia, hiperestesia o disestesias) y la inconformidad cosmética continúan siendo motivo de preocupación por parte de los pacientes, alterando su percepción subjetiva del resultado quirúrgico obtenido. En tiempos recientes la técnica mínimamente invasiva se ha descrito para el manejo de este tipo de fracturas, demostrando reducir las posibles complicaciones de la técnica tradicional abierta mientras que mantiene sus principales beneficios, optimizando además la capacidad biológica reparativa de la clavícula, ya que respeta la vascularización del foco de fractura. El objetivo de este artículo es describir paso a paso la técnica quirúrgica mínimamente invasiva para el manejo de fracturas desplazadas del tercio medio de clavícula, reportando además los resultados clínicos obtenidos en una serie de casos intervenidos con esta técnica.


Abstract: Surgical management of displaced midshaft clavicular fractures has gained popularity in the last decade due to reductions in functional recovery times and lower rates of nonunion. However, several complications related to the open approach have been described and remain concerning for patients. These potential sequelae include scar pain, local irritation, peri-incisional numbness, and cosmetic deformity, all of which may contribute to unsatisfactory subjective outcomes. Recently, minimally invasive plate osteosynthesis (MIPO) technique has been described for the treatment of these fractures. This approach presents the opportunity to reduce shortcomings of the traditional open approach while maintaining its benefits, respecting the biological healing environment and preserving blood supply to the fracture site. The purpose of this study is to provide a step-by-step description of the MIPO surgical technique for management of displaced midshaft clavicular fractures and report the clinical outcomes of a case series using this technique.

7.
Acta Ortop Mex ; 35(5): 479-485, 2021.
Artigo em Espanhol | MEDLINE | ID: mdl-35451261

RESUMO

Surgical management of displaced midshaft clavicular fractures has gained popularity in the last decade due to reductions in functional recovery times and lower rates of nonunion. However, several complications related to the open approach have been described and remain concerning for patients. These potential sequelae include scar pain, local irritation, peri-incisional numbness, and cosmetic deformity, all of which may contribute to unsatisfactory subjective outcomes. Recently, minimally invasive plate osteosynthesis (MIPO) technique has been described for the treatment of these fractures. This approach presents the opportunity to reduce shortcomings of the traditional open approach while maintaining its benefits, respecting the biological healing environment and preserving blood supply to the fracture site. The purpose of this study is to provide a step-by-step description of the MIPO surgical technique for management of displaced midshaft clavicular fractures and report the clinical outcomes of a case series using this technique.


El tratamiento quirúrgico de las fracturas desplazadas del tercio medio de clavícula ha ganado popularidad durante la última década, ya que permite acortar el período de recuperación, acelerando la reincorporación laboral y deportiva, al mismo tiempo que disminuye significativamente el riesgo de no unión. Sin embargo, las molestias relacionadas con el abordaje cutáneo como dolor e irritación a nivel de la cicatriz, las alteraciones sensitivas persistentes (hipoestesia, hiperestesia o disestesias) y la inconformidad cosmética continúan siendo motivo de preocupación por parte de los pacientes, alterando su percepción subjetiva del resultado quirúrgico obtenido. En tiempos recientes la técnica mínimamente invasiva se ha descrito para el manejo de este tipo de fracturas, demostrando reducir las posibles complicaciones de la técnica tradicional abierta mientras que mantiene sus principales beneficios, optimizando además la capacidad biológica reparativa de la clavícula, ya que respeta la vascularización del foco de fractura. El objetivo de este artículo es describir paso a paso la técnica quirúrgica mínimamente invasiva para el manejo de fracturas desplazadas del tercio medio de clavícula, reportando además los resultados clínicos obtenidos en una serie de casos intervenidos con esta técnica.


Assuntos
Clavícula , Fraturas Ósseas , Placas Ósseas , Clavícula/cirurgia , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Fraturas Ósseas/cirurgia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Resultado do Tratamento
8.
Eur J Orthop Surg Traumatol ; 31(3): 449-458, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32929614

RESUMO

OBJECTIVE: The aim of this study was to evaluate the neuromuscular structures at risk during modified anterior minimally invasive plating osteosynthesis technique (Belangero-Livani) for humeral shaft fractures. METHODS: Eight fresh-frozen human specimens ranging from 38 to 82 years old were used. Specimens were positioned supine with the shoulder in 70° abduction and the forearm in full supination. Anterior minimally invasive plating osteosynthesis technique according to Belangero-Livani technique was performed in each specimen. Under radioscopic control, the plate was introduced in retrograde fashion through the subbrachialis path. Anatomical structures were inspected and different anatomical parameters were measured after dissection at the end of the surgical procedures. Measurements were performed using a high digital caliper. Statistical analysis was performed using the Pearson's correlation coefficient test. A p value of < 0.05 was used to define statistical significance. RESULTS: There were no macroscopic lesions of myotendinous or neurovascular structures in any specimen. The mean distance between the radial nerve to the distal lateral end of the plate was 8.63 mm (range 4.14-13.83 mm). The mean total length of the humerus was 328.59 mm. We found a significant direct correlation between the total length of the humerus and both specimen height and weight. CONCLUSION: The modified Belangero-Livani anterior MIPO technique for humeral shaft fractures performed in retrograde fashion is safe and useful, without major risk to the soft tissue of the anterior compartment of the arm, including the radial nerve in the lateral intermuscular septum. Intraoperative dissection, avoiding deep lateral retraction on the distal approach, minimizes the risk of radial nerve damage. Strict surgical planning and appreciation for the anatomic landmarks can reduce the risk of damage to neuromuscular structures. LEVEL OF EVIDENCE: Level IV; Case series with no comparison group; Treatment study.


Assuntos
Fraturas do Úmero , Procedimentos Cirúrgicos Minimamente Invasivos , Placas Ósseas , Fixação Interna de Fraturas/efeitos adversos , Humanos , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Resultado do Tratamento
9.
J Orthop Case Rep ; 8(3): 42-46, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30584514

RESUMO

INTRODUCTION: The use of mini plates as a reduction tool is an elegant technique for temporary stabilization of multifragmentary fractures. For some complex periarticular fractures with severe comminution close to the articular surface, mini plates seem to be a better option than K-wires for provisional as well as definitive fixation, because of the presence of small fragments and proximity to the joint increases the risk of additional fragmentation and articular penetration, respectively. CASE REPORT: Five cases of complex periarticular fractures of the upper limb are presented. We used 2.3 mm mini plates as reduction plates for different situations, including one scapula fracture, one clavicle fracture, one distal humerus fracture, one proximal ulna fracture, and one distal radius fracture. In all cases, an excellent clinical outcome with a full return to pain-free activity was achieved after a minimum follow-up of 12 months. CONCLUSION: We feel that these mini extra-articular implants are particularly helpful as temporary reduction tools before the application of the definitive implant to a reduced and stabilized the fracture. Because they have longer screws allowing better cortical purchase and low-profile allowing plate overlap, the procedure seems to be faster and easier when compared to the use of temporary K-wires and clamps.

10.
Rev. colomb. ortop. traumatol ; 32(1): 28-32, Marzo 2018. ilus.
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1373014

RESUMO

Introducción Para las fracturas de húmero diafisario de manejo quirúrgico, los abordajes por mínima invasión mejoran desenlaces. Se han descrito varios. Sin embargo, para el abordaje posterior no existe claridad entre la relación anatómica del nervio radial y las incisiones o la posición de la placa. El objetivo de este estudio es describir la relación anatómica del nervio radial tanto con las incisiones del abordaje posterior por mínima invasión como con la punta distal de la placa. Materiales y métodos se realizó un estudio descriptivo en cadáveres sin traumatismo de miembros superiores, en prono con 45° de abducción de hombro y 90° de flexión de codo, tras deslizar una placa de 2,7 mm. Se consignaron en milímetros las distancias del nervio radial respecto a los puntos de referencia del abordaje y la punta distal de la placa. Resultados Por término medio, la longitud humeral fue 286,6 mm; la distancia del epicóndilo lateral al nervio radial, 155,1 mm; la aponeurosis tricipital al nervio radial, 138,9 mm, y la punta distal de la placa al nervio radial, 155,6 mm. Discusión La fijación con placa por mínima invasión por abordaje posterior puede ser segura para las fracturas de húmero diafisario respecto a la lesión del nervio radial, al ubicar los tornillos de la placa por fuera de 128,5-169,5 mm medidos desde la punta de la placa aunque se requieren estudios clínicos para demostrar la seguridad de este abordaje. Nivel de evidencia clínica Nivel IV.


Background It is well known that the various minimally invasive approaches described improve outcomes for the surgical fixation of diaphyseal humerus fractures. However, there is a lack of information between the anatomical relationship of the radial nerve for the required incisions or for the position of the plate when a posterior approach is used. The objective of the study is to describe the anatomical relationship of the radial nerve with both incisions of the posterior minimally invasive approach, and with the distal tip of the osteosynthesis plate. Materials and methods A descriptive study was performed on cadavers without trauma of upper limbs, in prone with 45° of abduction of shoulder and 90° of elbow flexion. After sliding a plate of 2.7 mm, the distances of the radial nerve with respect to the reference points of the approach and distal tip of the plate were recorded in millimetres. Results A mean humeral length of 286.6 mm was found. The mean distance from the lateral epicondyle to the radial nerve was 155.1 mm. The mean distance from the tricipital aponeurosis to the radial nerve was 138.9 mm, and from the distal tip of the plate to the radial nerve was 155.6 mm. Discussion Plate fixation using minimal invasive technique using a posterior surgical approach may be safe for diaphyseal fractures of the humerus with respect to radial nerve injuries, as long as the plate screws are located outside the range of 128.5 mm to 169.5 mm measured from the tip of the plate. Clinical studies are required to demonstrate the safety of this approach. Evidence level IV.


Assuntos
Humanos , Fraturas do Úmero , Nervo Radial , Fixação Interna de Fraturas
11.
Rev. chil. ortop. traumatol ; 57(2): 54-59, mayo-ago. 2016. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-909709

RESUMO

La picnodisostosis es una enfermedad poco común que pertenece a las displasias esqueléticas que presentan fragilidad ósea y fracturas frecuentes. Radiológicamente se caracteriza por incremento de la densidad y fragilidad óseas. OBJETIVO: Presentar el caso de un escolar con displasia esquelética con fracturas en hueso patológico y manejo quirúrgico. CASO CLÍNICO: Escolar de sexo femenino, con antecedente de picnodisostosis detectado en etapa preescolar. Consulta posterior a caída de bicicleta con fractura de ambos fémures que se manejan quirúrgicamente con placa de compresión bloqueada.


Pycnodysostosis is a rare condition within skeletal dysplasias presenting with brittle bones and frequent fractures. Radiologically, it is characterised by increased bone density and fragility. OBJECTIVE: To present the case of a primary schoolchild with skeletal dysplasia with pathological bone fractures and their surgical management. CASE REPORT: A female primary schoolchild with a history of pycnodysostosis detected during the pre-school period. She was seen after bicycle fall that resulted in the fracture of both femurs, that were surgically managed with a locking compression plate.


Assuntos
Humanos , Feminino , Criança , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/etiologia , Picnodisostose/complicações , Fixação Interna de Fraturas/métodos , Radiografia , Procedimentos Cirúrgicos Minimamente Invasivos , Fraturas do Fêmur/diagnóstico por imagem , Picnodisostose/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA