Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pituitary ; 27(4): 345-359, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38888685

RESUMO

CONTEXT: Once hypercortisolemia is confirmed, differential diagnosis between Cushing's syndrome (CS) due to neoplastic endogenous hypercortisolism and non-neoplastic hypercortisolism (NNH, pseudo-Cushing's syndrome) is crucial. Due to worldwide corticotropin-releasing hormone (CRH) unavailability, accuracy of alternative tests to dexamethasone (Dex)-CRH, is clearly needed. OBJECTIVE: Assess the diagnostic accuracy of Dex-CRH test, desmopressin stimulation test, midnight serum cortisol (MSC), and late-night salivary cortisol (LNSC) levels to distinguish CS from NNH. METHODS: Articles through March 2022 were identified from Scopus, Web of Science, MEDLINE, EMBASE, and PubMed. All steps through the systematic review were performed independently and in duplicate and strictly adhered to the updated PRISMA-DTA checklist. DATA SYNTHESIS: A total of 24 articles (1900 patients) were included. Dex-CRH had a pooled sensitivity and specificity of 91% (95%CI 87-94%; I2 0%) and 82% (73-88%; I2 50%), desmopressin test 86% (81-90%; I2 28%) and 90% (84-94%; I2 15%), MSC 91% (85-94%; I2 66%) and 81% (70-89%; I2 71%), and LNSC 80% (67-89%; I2 57%) and 90% (84-93%; I2 21%), respectively. Summary receiver operating characteristics areas under the curve were Dex-CRH 0.949, desmopressin test 0.936, MSC 0.942, and LNSC 0.950 without visual or statistical significance. The overall risk of studies bias was moderate. CONCLUSION: Dex-CRH, the desmopressin stimulation test, and MSC have similar diagnostic accuracy, with Dex-CRH and MSC having slightly higher sensitivity, and the desmopressin test being more specific. LNSC was the least accurate, probably due to high heterogeneity, intrinsic variability, different assays, and lack of consistent reported cutoffs. When facing this challenging differential diagnosis, the results presented here should increase clinicians' confidence when deciding which test to perform.


Assuntos
Síndrome de Cushing , Humanos , Síndrome de Cushing/diagnóstico , Hidrocortisona/sangue , Hidrocortisona/metabolismo , Diagnóstico Diferencial , Hormônio Liberador da Corticotropina/metabolismo , Dexametasona , Desamino Arginina Vasopressina
2.
Front Endocrinol (Lausanne) ; 15: 1332120, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38352712

RESUMO

We evaluated the accuracy of the 10 µg desmopressin test in differentiating Cushing disease (CD) from non-neoplastic hypercortisolism (NNH) and ectopic ACTH syndrome (EAS). A systematic review of studies on diagnostic test accuracy in patients with CD, NNH, or EAS subjected to the desmopressin test obtained from LILACS, PubMed, EMBASE, and CENTRAL databases was performed. Two reviewers independently selected the studies, assessed the risk of bias, and extracted the data. Hierarchical and bivariate models on Stata software were used for meta-analytical summaries. The certainty of evidence was measured using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation Working Group) approach. In total, 14 studies were included: 3 studies on differentiated CD versus NNH and 11 studies on differentiated CD versus EAS. Considering ΔACTH in 8 studies involving 429 patients, the pooled sensitivity for distinguishing CD from EAS was 0.85 (95% confidence interval [CI]: 0.80-0.89, I2 = 17.6%) and specificity was 0.64 (95% CI: 0.49-0.76, I2 = 9.46%). Regarding Δcortisol in 6 studies involving 233 participants, the sensitivity for distinguishing CD from EAS was 0.81 (95% CI: 0.74-0.87, I2 = 7.98%) and specificity was 0.80 (95% CI: 0.61-0.91, I2 = 12.89%). The sensitivity and specificity of the combination of ΔACTH > 35% and Δcortisol > 20% in 5 studies involving 511 participants were 0.88 (95% CI: 0.79-0.93, I2 = 35%) and 0.74 (95% CI: 0.55-0.87, I2 = 27%), respectively. The pooled sensitivity for distinguishing CD from NNH in 3 studies involving 170 participants was 0.88 (95% CI: 0.79-0.93) and the specificity was 0.94 (95% CI: 0.86-0.97). Based on the desmopressin test for differentiating CD from EAS, considering ΔACTH, Δcortisol, or both percent increments, 15%, 19%, or 20% of patients with CD, respectively, would be incorrectly classified as having EAS. For CD versus NNH, 11% of patients with CD would be falsely diagnosed as having NNH, whereas 7% of patients with NNH would be falsely diagnosed as having CD. However, in all hierarchical plots, the prediction intervals were considerably wider than the confidence intervals. This indicates low confidence in the estimated accuracy, and the true accuracy is likely to be different. Systematic review registration: https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=85634, identifier CRD42018085634; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=68317, identifier CRD42017068317.


Assuntos
Síndrome de ACTH Ectópico , Síndrome de Cushing , Hipersecreção Hipofisária de ACTH , Humanos , Síndrome de Cushing/diagnóstico , Desamino Arginina Vasopressina , Diagnóstico Diferencial , Síndrome de ACTH Ectópico/diagnóstico , Hipersecreção Hipofisária de ACTH/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA