Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Microsc Microanal ; 30(4): 692-702, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39107241

RESUMO

Deformation bands are common constituents of porous clastic fluid reservoirs. Various techniques have been used to study deformation band structure and the associated changes in porosity and permeability. However, the use of electron backscatter diffraction technique is limited. Thus, more information is needed regarding the crystallographic relationships between detrital crystals, which can significantly impact reservoir rock quality. We employ microscopic and microstructural investigation techniques to analyze the influence of cataclastic deformation bands on pore space. Porosity measurements of the Cretaceous Ilhas Group sandstone in NE Brazil, obtained through computerized microtomography, indicate that the undeformed domains exhibit a total porosity of up to 13%. In contrast, this porosity is slightly over 1% in the deformation bands. Scanning electron microscopy analyses revealed the presence of grain fragmentation and dissolution microstructures, along with cement-filling pre-existing pores. The electron backscatter diffraction analyses indicated extensive grain fragmentation and minimal contribution from intracrystalline plasticity as a deformation mechanism. However, the c axes of quartz crystals roughly align parallel to the orientation of the deformation band. In summary, we have confirmed and quantified the internal changes in a deformation band cluster, with grain size reduction and associated compaction as the main mechanism supported by quartz cementation.

2.
J Mech Behav Biomed Mater ; 130: 105186, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35405520

RESUMO

Parameterized cellular microstructures allow for the development of efficient multiscale optimization strategies for the design of Functionally Graded Scaffolds (FGSs). This work assesses the biomimetic capabilities of the Voronoi-based cancelous bone microstructure introduced by Fantini et al. (2016) in terms of histomorphometric and elastic properties. Histomorphometric data of 23 bovine bone specimens and elastic data of 140 human bone specimens are used as reference. Based on the key findings that there exists a strong correspondence between the trabecular thickness and the solid volume fraction for natural cancelous bone, and that the stretching of the Voronoi microstructure is an effective means to induce anisotropy, the generative procedure by Fantini et al. (2016) is assessed and tuned to account for anisotropy and elastic properties. It is shown that the resulting mimetic microstructures have histomorphometric features and elastic properties that are in very good accordance to those of the natural samples. The outcomes of this work are a step forward towards the integration of the Voronoi-based microstructure into multiscale design tools.


Assuntos
Biomimética , Osso e Ossos , Animais , Anisotropia , Bovinos , Elasticidade , Humanos
3.
Anat Rec (Hoboken) ; 305(12): 3385-3397, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35338614

RESUMO

Racehorses are exposed to repetitive overload during training and competition, causing joint hyperextension, tissue fatigue, and ultimately skeletal failure. Some degree of bone changes, such as sclerosis, are expected in equine athletes, as adaptation to the biomechanical rigors of training and racing. Understanding the imaging characteristics of the equine joint surface and subchondral bone would allow earlier detection of injuries or adaptation, improving prognosis and training programs. This study sought to describe the joint surface structural patterns and the periarticular structures of the third metacarpal bone (MC3). Both forelimbs of eight horses engaged in daily training programs, aged 3-5 years, which were euthanized for reasons unrelated to the metacarpophalangeal (MCP) joints, were collected. Specimens were evaluated through macroscopic inspection, radiography, ultrasonography, and microscopic examinations, such as optical microscopy and microtomography. Analysis of the microtomography images showed that 50% of the samples had higher trabecular thickness in the lateral condyle. Comparison of each imaging examination revealed that ultrasound images were most closely related to the histological examination (p = .29) in terms of sensitivity, while macroscopic and radiographic examinations differed most between evaluators. Finally, the irregularities and modifications observed in the articular cartilage surface and subchondral bone were normal adaptations of the anatomical structures of trained racehorses, which should be considered during clinical examination.


Assuntos
Cartilagem Articular , Doenças dos Cavalos , Ossos Metacarpais , Condicionamento Físico Animal , Cavalos , Animais , Ossos Metacarpais/diagnóstico por imagem , Metacarpo/lesões , Metacarpo/patologia , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Doenças dos Cavalos/etiologia , Doenças dos Cavalos/patologia
4.
Proc Natl Acad Sci U S A ; 117(3): 1566-1572, 2020 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-31919285

RESUMO

While surface microstructures of butterfly wings have been extensively studied for their structural coloration or optical properties within the visible spectrum, their properties in infrared wavelengths with potential ties to thermoregulation are relatively unknown. The midinfrared wavelengths of 7.5 to 14 µm are particularly important for radiative heat transfer in the ambient environment, because of the overlap with the atmospheric transmission window. For instance, a high midinfrared emissivity can facilitate surface cooling, whereas a low midinfrared emissivity can minimize heat loss to surroundings. Here we find that the midinfrared emissivity of butterfly wings from warmer climates such as Archaeoprepona demophoon (Oaxaca, Mexico) and Heliconius sara (Pichincha, Ecuador) is up to 2 times higher than that of butterfly wings from cooler climates such as Celastrina echo (Colorado) and Limenitis arthemis (Florida), using Fourier-transform infrared (FTIR) spectroscopy and infrared thermography. Our optical computations using a unit cell approach reproduce the spectroscopy data and explain how periodic microstructures play a critical role in the midinfrared. The emissivity spectrum governs the temperature of butterfly wings, and we demonstrate that C. echo wings heat up to 8 °C more than A. demophoon wings under the same sunlight in the clear sky of Irvine, CA. Furthermore, our thermal computations show that butterfly wings in their respective habitats can maintain a moderate temperature range through a balance of solar absorption and infrared emission. These findings suggest that the surface microstructures of butterfly wings potentially contribute to thermoregulation and provide an insight into butterflies' survival.


Assuntos
Regulação da Temperatura Corporal/fisiologia , Borboletas/fisiologia , Raios Infravermelhos , Asas de Animais/fisiologia , Animais , Colorado , Biologia Computacional , Ecossistema , Equador , Florida , México , Modelos Biológicos , Fenômenos Ópticos , Análise Espectral , Luz Solar , Temperatura , Asas de Animais/ultraestrutura
5.
Sensors (Basel) ; 19(23)2019 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-31766416

RESUMO

In this paper, we introduce a novel type of transdermal drug delivery device (TD3) with a micro-electro-mechanical system (MEMS) design using computer-aided design (CAD) techniques as well as computational fluid dynamics (CFD) simulations regarding the fluid interaction inside the device during the actuation process. For the actuation principles of the chamber and microvalve, both thermopneumatic and piezoelectric principles are employed respectively, originating that the design perfectly integrates those principles through two different components, such as a micropump with integrated microvalves and a microneedle array. The TD3 has shown to be capable of delivering a volumetric flow of 2.92 × 10-5 cm3/s with a 6.6 Hz membrane stroke frequency. The device only needs 116 Pa to complete the suction process and 2560 Pa to complete the discharge process. A 38-microneedle array with 450 µm in length fulfills the function of permeating skin, allowing that the fluid reaches the desired destination and avoiding any possible pain during the insertion.


Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Desenho de Equipamento/instrumentação , Sistemas Microeletromecânicos/instrumentação , Administração Cutânea , Desenho Assistido por Computador/instrumentação , Humanos , Microinjeções/instrumentação , Agulhas , Preparações Farmacêuticas/administração & dosagem , Pele/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA