Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Appl Physiol Nutr Metab ; 47(2): 159-164, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34610270

RESUMO

It has been shown that the critical speed (CS) predicted from a perceptually self-regulated 10-min submaximal treadmill test (T10) is reliable and closely matches the CS estimated from conventional methods. To assess the relationship between the T10 and 5-km and 10-km running performances, 36 recreational runners (mean SD: age: 32.2 ± 6.2 years, height: 173.2 ± 7.3 cm, weight: 70.9 ± 8.8 kg, maximal oxygen uptake (V̇O2max): 53.3 ± 6.1 mL·kg-1·min-1) performed a ramp incremental test and 2 T10 tests (the first as a familiarization trial). Results showed that the T10 CS (3.9 ± 0.44 m·s-1) was significantly correlated with runners' last 6 months best performances in 5 km (20.3 ± 2.7 min; r = -0.90) and 10 km (42.7 ± 5.7 min; r = -0.91), the V̇O2max (r = 0.75), the speed associated with the gas exchange threshold (vGET: 3.38 ± 0.36 m·s-1; r = 0.76), the speed associated with the second ventilatory threshold (vVT2: 4.15 ± 0.49 m·s-1; r = 0.84), and the speed associated with the V̇O2max (vV̇O2max: 4.78 ± 0.54 m·s-1; r = 0.87). Moreover, 79% and 83% of the variance in 5-km and 10-km performances could be explained solely by the CS predicted from the T10. Results evidenced the strong relationship and practical performance relevance of the T10 CS test. Novelty: Critical speed derived from a 10-min submaximal treadmill test (T10) is significantly correlated with 5-km and 10-km running performances. The T10 critical speed test may represent a useful tool for assessing running performance capabilities.


Assuntos
Desempenho Atlético/fisiologia , Teste de Esforço/estatística & dados numéricos , Corrida/fisiologia , Velocidade de Caminhada/fisiologia , Adulto , Feminino , Humanos , Masculino , Consumo de Oxigênio , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
2.
J Sports Sci ; 39(8): 835-844, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33190620

RESUMO

We assessed the reliability and validity of a 10-min submaximal treadmill test (T10) to predict critical speed (CS). Forty-two runners completed a familiarization trial plus two experimental trials (T10 test and T10 retest). Reliability between the T10 test and T10 retest was assessed using coefficient of variation (CoV), limits of agreement (LoA) and intraclass correlation (ICC). For validity, the speed from the T10 retest was compared with the CS determined from 3 runs on separate days on a running track over 1200, 2400, and 3600 m (field test). Reliability between the T10 test and T10 retest showed a CoV of 3.4%, LoA of 0.05 ± 0.39 m.s-1, and an ICC of 0.93. Validity showed that speed (m.s-1) (T10 retest: 3.86 ± 0.51; field test: 3.88 ± 0.55) did not differ between trials. The T10 retest was highly correlated with the field test, r = 0.93, and the standard error for the estimate of CS using the T10 retest was 0.06 m.s-1, and the LoA was 0.02 ± 0.40 m.s-1. A submaximal 10-min treadmill test (T10) provides a practical and accessible method to estimate CS.


Assuntos
Teste de Esforço , Corrida/fisiologia , Adulto , Feminino , Humanos , Masculino , Consumo de Oxigênio , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA