Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 18: 1915-1920, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38974664

RESUMO

Purpose: We describe an alternative automated technique that consists of simultaneous anterior capsule puncture and decompression of the capsular bag by using an insulin needle attached to the aspiration tubing of the phacoemulsification device to prevent the occurrence of the "Argentinian Flag sign" during capsulorhexis in intumescent cataract. Setting: Instituto de Olhos de Assis and Center of Specialties Hoftalmed, located in the state of São Paulo, Brazil. Design: Prospective interventional study. Methods: Eighty-eight eyes of 88 patients with white or intumescent cataracts were included in this study. Routine clear cornea incision, capsule staining with trypan blue, intracameral anesthesia, and ophthalmic viscoelastic device were used before the procedure. A 26-gauge needle was connected to the phacoemulsification aspiration tubing using a double male Luer connector for irrigation, and aspiration was inserted into the anterior chamber through a new paracentesis incision with the bevel facing down. Immediately after insertion, automated aspiration of the liquefied cortex was performed to remove anterior intralenticular material and achieve capsular decompression. Compression of the nucleus with the needle tip was performed to remove any liquefied material trapped between the posterior surface of the nucleus and the posterior capsule. All surgeries were performed using the same phacoemulsification and parameters. The rate of complete continuous capsulorhexis was observed and noted. Results: No complications were observed in any of the cases. A single-stage, continuous, and well-centered capsulorhexis was achieved in 100% of cases. Conclusion: We conclude that a simultaneous puncture and decompression of the capsular bag using an insulin needle attached to the aspiration tubing of the phacoemulsification machine effectively avoided the "Argentinian Flag sign" in intumescent cataract surgery.

2.
Indian J Ophthalmol ; 69(6): 1398-1403, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34011708

RESUMO

Purpose: To present a case series of intumescent white cataract cases managed by a new surgical technique to attain a single stage Continuous Curvilinear Capsulorhexis (CCC). Methods: The series included 60 eyes of 60 patients with white cataract which underwent preoperative anterior chamber depth, lens thickness and ultrasonographic A-scan for intralenticular spikes. A partial size main port (~1.8mm) is created as the first entry into the anterior chamber (AC). A 30-gauge needle of insulin syringe entered through a limbal stab incision is used to decompress the anterior and posterior intralenticular compartments. Following which a standard size, one stage capsulorhexis was performed in a trypan blue stained capsule using microcapsulorhexis forceps entered through the partial sized trapezoidal main port. The main port was secondarily enlarged for phacoemulsification. Results: Based on the intraoperative findings, 43 eyes were categorized as Intumescent type-1 cataracts i.e., with presence of actual liquefied cortex aspirated using 30-gauge needle and 17 eyes as Intumescent type-2 cataracts, i.e., presence of swollen lens without any obvious liquefied cortex. Standard size, circular and centred CCC was achieved in 100% of the cases and no Argentinean flag sign was noted. Surgeon perceived raised intralenticular pressure in 41% of the cases in type-1 subset and 61% cases in type-2 subset (P-0.06). Posterior capsular plaque was observed in 22% of the cases, adherent cortex in 25% and anterior capsular plaque in 5% of the cases. At 6weeks follow up 92% patients had best corrected visual acuity of 20/40 or better. Conclusion: A multi-layered approach can help in attaining successful CCC in cases of white mature cataract with high intralenticular pressure.


Assuntos
Extração de Catarata , Catarata , Cápsula do Cristalino , Facoemulsificação , Capsulorrexe , Catarata/diagnóstico , Humanos , Cápsula do Cristalino/diagnóstico por imagem , Cápsula do Cristalino/cirurgia
3.
Indian J Ophthalmol ; 66(9): 1304-1306, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30127146

RESUMO

In this communication, we describe a technique for creation of a single stage, adequately sized capsulorrhexis in intumescent cataracts by depressurizing the anterior and posterior intralenticular compartments in a nonleaky anterior chamber (AC) to prevent capsulorrhexis extension and Argentina flag sign. Initially, an incomplete main-port incision is made by the partial entry of a 2.2-mm keratome. A cohesive dispersive ophthalmic viscosurgical device (OVD) is injected into AC. Standard side-port incisions are made, followed by anterior capsular staining. The fluid cortex in anterior intralenticular compartment is aspirated by puncturing anterior capsule in the center using a 30-gauge needle entered through a separate limbal stab incision. The nucleus edge is gently tipped posteriorly with the needle tip to release the fluid from posterior intralenticular compartment also and as much fluid aspirated as possible. OVD is again injected and capsulorrhexis is performed in a single stage using micro-capsulorrhexis forceps.


Assuntos
Câmara Anterior/cirurgia , Capsulorrexe/métodos , Catarata/diagnóstico , Cápsula do Cristalino/cirurgia , Implante de Lente Intraocular/métodos , Facoemulsificação/métodos , Complicações Pós-Operatórias/prevenção & controle , Câmara Anterior/diagnóstico por imagem , Humanos , Cápsula do Cristalino/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA