Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1288: 342177, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38220307

RESUMO

BACKGROUND: the chemometric processing of second-order chromatographic-spectral data is usually carried out with the aid of multivariate curve resolution-alternating least-squares (MCR-ALS). Recently, an alternative procedure was described based on the estimation of image moments for each data matrix and subsequent application of multiple linear regression after suitable variable selection. RESULTS: The analysis of both simulated and experimental data leads to the conclusion that the image moment method, although can cope with chromatographic lack of reproducibility across injections, it only performs well in the absence of uncalibrated interferents. MCR-ALS, on the other hand, provides good analytical results in all studied situations, whether the test samples contain uncalibrated interferents or not. SIGNIFICANCE: The results are useful to assess the real usefulness of newly proposed methodologies for second-order calibration in the case of chromatographic-spectral data sets, especially when samples contain unexpected chemical constituents.

2.
Front Bioeng Biotechnol ; 10: 934041, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36619379

RESUMO

The instantaneous spatial representation of electrical propagation produced by muscle contraction may introduce bias in surface electromyographical (sEMG) activation maps. Here, we described the effect of instantaneous spatial representation (sEMG segmentation) on embedded fuzzy topological polyhedrons and image features extracted from sEMG activation maps. We analyzed 73,008 topographic sEMG activation maps from seven healthy participants (age 21.4 ± 1.5 years and body mass 74.5 ± 8.5 kg) who performed submaximal isometric plantar flexions with 64 surface electrodes placed over the medial gastrocnemius muscle. Window lengths of 50, 100, 150, 250, 500, and 1,000 ms and overlap of 0, 25, 50, 75, and 90% to change sEMG map generation were tested in a factorial design (grid search). The Shannon entropy and volume of global embedded tri-dimensional geometries (polyhedron projections), and the Shannon entropy, location of the center (LoC), and image moments of maps were analyzed. The polyhedron volume increased when the overlap was <25% and >75%. Entropy decreased when the overlap was <25% and >75% and when the window length was <100 ms and >500 ms. The LoC in the x-axis, entropy, and the histogram moments of maps showed effects for overlap (p < 0.001), while the LoC in the y-axis and entropy showed effects for both overlap and window length (p < 0.001). In conclusion, the instantaneous sEMG maps are first affected by outer parameters of the overlap, followed by the length of the window. Thus, choosing the window length and overlap parameters can introduce bias in sEMG activation maps, resulting in distorted regional muscle activation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA