Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz. dent. j ; Braz. dent. j;34(5): 36-42, Sept.-Oct. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1528022

RESUMO

Abstract Evaluate the shaping ability and preparation time using a pediatric motor-driven rotary instrumentation compared to other systems in resin prototypes of primary molars. Methods: Thirty specimens were scanned in micro-CT and divided into three groups according to the instrumentation type: pediatric motor-driven Sequence baby File (SBF); conventional motor-driven (Sequence Rotary File - SRF); manual K file. Instrumentation time was timed. After preparation, the specimens were scanned again. The pre- and post-instrumentation images were superimposed to measure the amount of root canal deviation and the resin remnant thickness. ANOVA followed by the Tukey test analyzed the comparisons between groups (p<0.05). Results: No statistically significant differences occurred in root canal deviation among groups (p>0.05). There were statistically significant differences in the comparison among root thirds (p<0.001) but without significant differences in the interaction group vs. root third (p>0.05). Both motor-driven instrumentations showed statistically greater weariness than manual instrumentation (p<0.001), without significant significant differences between SBF and SRF. Motor-driven instrumentation had a shorter working time than manual instrumentation (p<0.001). Conclusion: Pediatric motor-driven instrumentation demonstrated good outcomes in relation to root canal deviation and amount of remnant structure, with shorter instrumentation time. SBF can be a suitable alternative for endodontic instrumentation in primary molars.


Resumo Objetivo: Avaliar os resultados da instrumentação endodôntica e o tempo de preparo de lima odontopediátrica ativada por motor (Sequence Baby File- SBF) em canais de molares decíduos prototipados. Métodos: Trinta espécimes foram escaneados em micro-CT e divididos em três grupos de acordo com o tipo de instrumentação: mecanizada odontopediátrica (SBF); mecanizada convencional; lima K manual. O tempo de instrumentação foi cronometrado. Após o preparo, os espécimes foram escaneados novamente. As imagens pré e pós-instrumentação foram sobrepostas e a quantidade de desvio do canal radicular e a espessura de resina remanescente foram mensurados. Para as análises de comparações entre os grupos foram realizados teste ANOVA seguido do teste de Tukey (p<0,05). Resultados: Não ocorreram diferenças estatisticamente significativas entre os grupos no desvio do canal radicular (p>0,05). Houve diferenças estatisticamente significativas na comparação entre terços radiculares (p<0,001), mas sem diferenças significativas na interação grupo vs. terço radicular (p>0,05). A instrumentação mecanizada apresentou desgaste estatisticamente maior do que a instrumentação manual (p<0,001), sem diferenças estatísticas entre a SBF e a lima mecanizada convencional. A instrumentação mecanizada teve menor tempo de trabalho quando comparado a instrumentação manual (p<0,001). Conclusão: A instrumentação mecanizada odontopediátrica demonstrou bons resultados em relação ao desvio do canal radicular e quantidade de estrutura remanescente, com menor tempo de instrumentação. A SBF pode ser uma alternativa adequada para a instrumentação endodôntica em molares decíduos.

2.
Rio de Janeiro; s.n; 2022. 129 p.
Tese em Português | BBO - Odontologia | ID: biblio-1415074

RESUMO

Objetivou-se elaborar um e-book aos cirurgiões-dentistas sobre as opções de sistema de instrumentação endodôntica para dentes decíduos e comparar os resultados biomecânicos de diferentes sistemas e seu tempo de preparo em protótipos de dentes decíduos por meio de uma análise em micro-CT. Para isso, foram realizados dois estudos. No primeiro, realizou-se uma busca bibliográfica em seis bases de dados por estudos laboratoriais e clínicos sobre protocolos de pulpectomia utilizando pelo menos uma técnica de instrumentação. Dados a respeito das características, cinemática, benefícios e orientações à cerca da utilização de acordo com as instruções dos fabricantes foram extraídos para elaboração do conteúdo teórico e diagramação do layout do e-book, confeccionado no programa Canva. Após finalizado, o mesmo foi avaliado por três pós-graduandos da Disciplina de Odontopediatria da FOUFRJ e as sugestões foram incorporadas. Elaborou-se o material intitulado ''Guia ilustrado de instrumentação endodôntica para dentes decíduos'' contendo 43 páginas, abordando 13 sistemas de instrumentação, com sequências ilustradas de protocolos para utilização. Para o segundo estudo foram utilizados 60 protótipos padronizados de segundos molares decíduos inferiores confeccionados em polímero transparente para avaliar os resultados biomecânicos da instrumentação com diferentes sistemas de limas. Foram utilizados os sistemas manual k-file e mecanizados ProTaper Nextâ (PTN), XP- Endoâ Shaper (XPS), XP- Endoâ Finisher (XPF), XP­Clean (XPC) e Sequence Baby file (SBF) (n= 10/cada). A instrumentação foi realizada por um único operador treinado e o tempo de utilização de cada sistema foi cronometrado. Realizouse a irrigação com um total de 16mL de soro fisiológico à 0,9% para cada canal instrumentado, associada a aspiração simultânea. Os protótipos foram escaneados antes e após da instrumentação através do micro-CT. A reconstrução foi padronizada os conjuntos de imagens iniciais e instrumentados foram registrados entre si. Alterações no volume do canal radicular, área não instrumentada, debris acumulados, volume de dentina removido e transporte do canal foram quantificados. Os dados foram tabulados no programa JAMOVI versão 1.6 e analisados através do teste Shapiro-Wilk para verificar a distribuição dos dados. Para distribuição normal foram realizados testes paramétricos e para aqueles que não seguiram a normalidade, testes não paramétricos foram utilizados, todos com um nível de significância de 5% (p<0,05). A instrumentação com sistemas mecanizados resultou em menos tempo de instrumentação (p< 0,001) do que com a k-file. A porcentagem de áreas não instrumentadas foi semelhante para todos os sistemas. O acúmulo de debris foi maior para K-file e XPS ao longo de todo o canal (p<0,05). Todos os grupos apresentaram aumento do volume do canal radicular após a instrumentação (p= 0,003) com valores mais elevados na lima K-file (p<0,05). A análise 3D revelou maior transporte da lima K-file. SBF e K-file apresentaram, respectivamente, o menor (0,01 ± 0,01 e 0,03 ± 0,04) e o maior (0,04 ± 0,05 e 0,32 ± 0,94) valor de transporte do canal nos protótipos. Diante das metodologias utilizadas, conclui-se que um material relevante e prático ficará disponível nas plataformas digitais da Disciplina de Odontopediatria da UFRJ, para livre acesso e ampla divulgação aos cirurgiões-dentistas. Além disso, com relação aos resultados de instrumentação mecânica, o SBF e o XPC resultaram em uma abordagem mais conservadora. A instrumentação mecânica pode levar à algum grau de transporte do canal e deixar partes das paredes do canal infectadas sem preparo mecânico. (AU)


The objective was to elaborate an e-book to dentists about the options of endodontic instrumentation system for primary teeth and to compare the biomechanical outcomes of the different systems and their instrumentation time in prototypes of primary teeth through micro-CT analysis. To this end, two studies were carried out. In developing the first, a bibliographic search was carried out in six databases. Laboratory and clinical studies with a pulpectomy protocol using at least one instrumentation technique were included. Data about features, kinematics, benefits, and guidelines on use according to the manufacturer's instructions were extracted to prepare the theoretical content and layout diagramming of the e-book using Canva software. Afterwards, it was evaluated by 3 postgraduate students of the Pediatric Dentistry Discipline-FOUFRJ and the suggestions for changes were incorporated. The product entitled 'Guia ilustrado de instrumentação endodôntica para dentes decíduos' contains 43 pages covering 13 instrumentation systems and illustrated sequence of protocols use for each. The second consists of 60 standardized prototype teeth of mandibular second primary molars made with transparent polymer to evaluate the outcomes of biomechanical instrumentation of different systems. Manual k-file, ProTaper Nextâ (PTN), XP-Endoâ Shaper (XPS), XP-Endoâ Finisher (XPF), XP ­ Clean (XPC) and Sequence Baby file (SBF) (n= 10/each) were used. The specimen instrumentation was performed by a single trained and the time spend was recorded. Irrigation was performed with a total of 16mL of 0.9% saline solution for each instrumented canal and simultaneous aspiration. The prototypes were scanned before and after the instrumentation using micro-CT. In addition, the reconstruction was standardized and initial and instrumented image sets were registered with each other. Next, changes in root canal volume, noninstrumented areas, accumulated debris, removed dentin volume and canal transportation were quantified. Data were tabulated in the JAMOVI program version 1.6 and analyzed using the Shapiro-Wilk test to verify the data distribution. For normal distribution, parametric tests were performed and that did not follow normality, nonnormal tests were used, all with a significance level of 5% (p<0.05). Instrumentation with rotary files resulted in less time-consuming (p <0.001) than manual k-file. The percentage of non-instrument areas were similar for all systems. Accumulated debris was higher for K-file and XPS along the entire canal. All groups showed an increase in root canal volume after instrumentation (p= 0.003) with higher values in K-file (p <0.05). 3D analysis revealed greater transportation in K-file. SBF and K-file showed, respectively, the lowest (0.01± 0.01 and 0.03 ± 0.04) and highest (0.04 ± 0.05 and 0.32 ± 0.94) canal transportation value in the prototypes. Given the methodology applied, it was concluded that: the didactic material will be available on the digital platforms of Pediatric Dentistry at UFRJ for free access and widespread. From the overall mechanical instrumentation outcomes, the SBF and XPC resulted in a more conservative approach. Mechanical instrumentation may lead transportation and leave preparation. (AU)


Assuntos
Pulpectomia/instrumentação , Dente Decíduo , Fenômenos Biomecânicos , Odontólogos , Endodontia/instrumentação , Fatores de Tempo , Técnicas In Vitro , Guias de Prática Clínica como Assunto , Microtomografia por Raio-X , Dente Molar
3.
Int J Paediatr Dent ; 29(1): 50-57, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30264472

RESUMO

BACKGROUND: Efficient endodontic instrumentation of primary teeth is a challenge for paediatric dentists. AIM: To evaluate biomechanical outcomes of endodontic instrumentation with a reciprocating system in a polymer-prototyped primary maxillary central incisor. DESIGN: The specimen was systematically instrumented and micro-CT scanned before and after each file. The amount of debris, percentage of non-instrumented areas, removed dentin volume, and lower dentin thickness at specific points along the root canal were analyzed. RESULTS: A 10% increase in removed dentin volume was observed when R40 was compared to R25 (14.5% vs 4.2%). When comparing R50 with R40, this increase was only 3.4% (17.9% vs 14.5%). In the root cervical third, there was substantial reduction in dentin thickness with R50 (48.8%), followed by R40 (39.5%) and R25 (18.6%). There was no difference between R25 and R40 in the removal of dentin at the apical third (15.8%), while R50 resulted in 39.8% reduction in dentin thickness. Percentage of non-instrumented areas were the same for all files. Accumulated debris with R40 and R50 was the same (0.19 mm³) while for R25 was 0.11 mm³. CONCLUSIONS: The Reciproc® system was effective for instrumentation of a prototyped primary maxillary central incisor. The most suitable file for apical preparation was R40.


Assuntos
Incisivo/cirurgia , Dente Decíduo/cirurgia , Instrumentos Odontológicos , Dentina , Humanos , Maxila , Resultado do Tratamento
4.
Odontol. vital ; jun. 2016.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1506802

RESUMO

El profesional en Endodoncia se plantea el dilema de hasta qué punto deben penetrar los instrumentos dentro del conducto. Por esta razón, la longitud real de las diferentes piezas dentales en distintas etnias y zonas geográficas de un mismo país es un dato importante y característico. Este estudio se realizó por medio de un análisis tomográfico en piezas extraídas. Se tomó una muestra representativa de las siete provincias de Costa Rica, utilizando 1470 raíces de 980 piezas dentales, 70 piezas superiores e inferiores, mostrando 210 raíces en su totalidad por provincia. Se logró determinar las longitudes reales de las diferentes piezas dentales de los costarricenses. De acuerdo con la metodología utilizada, la muestra fue probabilística de tipo estratificado, con el fin de asegurar una representación de cada una de las provincias del país; se recolectaron piezas dentales en clínicas dentales privadas y públicas. Los resultados reflejan piezas dentales con medidas que se asemejan a otros estudios realizados en otras partes del mundo.


The great dilemma for the practitioner in endodontics is how far to penetrate with the instruments within the duct. For this reason, the real longitude of the different teeth in various ethnias and geographic zones of the same country is an important and characteristic data. This research was done through a tomographic analysis of the extracted teeth. A representative sample of the seven provinces of Costa Rica was taken, using 1470 roots of 980 teeth, 70 superior teeth and inferior, giving 210 roots in total per province. It was possible to determine the real longitudes of the different teeth of the costaricans. According to the methodology used, the sample was probable of the stratified type with the objective goal of assuring a representation of each one of the provinces of the country; the dental pieces were collected through private and public dental clinics. The results reflect teeth with similar measurements to other studies done in other parts of the world.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA