Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Clin Oral Investig ; 28(3): 161, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381269

RESUMO

OBJECTIVE: To assess the impact of enhancement filters on the formation of halo artifacts in radiographs of dental implants obtained with a complementary metal oxide semiconductor (CMOS) system. METHODS: Digital radiographs of dental implants placed in dry human mandibles were processed with the Noise Reduction smoothing filter, as well as the Sharpen 1, Sharpen 4, and Sharpen UM high-pass filters available in the CLINIVIEW™ software (Instrumentarium Dental, Tuusula, Finland). Subjective analysis involved evaluating the left, right, and apical surfaces of each implant for the presence of much, few, or no halo. The objective analysis involved measurement of the halo area using the Trainable Weka Segmentation plugin (ImageJ, National Institutes of Health, Bethesda, MD, USA). Data were analyzed using Friedman's test (subjective analysis) and ANOVA (objective analysis) (α = 5%). RESULTS: In the subjective evaluation, the Sharpen 4 filter produced more radiographs with much halo present, and in the objective evaluation, a bigger halo area when compared to the original images and the Noise Reduction filter for all surfaces (p < 0.05). CONCLUSIONS: When evaluating dental implants, priority should be given to original images and those enhanced with smoothing filters since they exhibit fewer halo artifacts. CLINICAL RELEVANCE: Post-processing tools, such as enhancement filters, may improve the image quality and assist some diagnostic tasks. However, little is known regarding the impact of enhancement filters in halo formation on CMOS systems, which have been increasingly used in dental offices.


Assuntos
Artefatos , Implantes Dentários , Estados Unidos , Humanos , Interface Osso-Implante , Óxidos , Semicondutores
2.
J Imaging Inform Med ; 37(1): 145-150, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38343236

RESUMO

To assess the effect of digital enhancement on the image quality of radiographs obtained with photostimulable phosphor (PSP) plates partially damaged by ambient light. Radiographs of an aluminum step wedge were obtained using the VistaScan and Express systems. Half of the PSP plates was exposed to ambient light for 0, 10, 30, 60, or 90 s before being scanned. The resulting radiographs were exported with and without digital enhancement. Metrics for brightness, contrast, and contrast-to-noise ratio (CNR) were derived, and the ratio of each metric between the exposed-to-light and non-exposed-to-light halves of the radiographs was calculated. The resulting ratios of the radiographs with digital enhancement were subtracted from those without digital enhancement and compared among each other. For the VistaScan system, digital enhancement partially restored brightness, contrast, and CNR. For the Express system, digital enhancement only restored CNR and not the impact of ambient light on brightness and contrast. Specifically, digital enhancement restored 23.48% of brightness for the VistaScan, while percentages below 1% were observed for the Express. Digital enhancement restored 53.25% of image contrast for the VistaScan and 5.79% for the Express; 40.71% of CNR was restored for the VistaScan, and 35% for the Express. Digital enhancement can partially restore the damage caused by ambient light on the brightness and contrast of PSP-based radiographs obtained with the VistaScan, as well as on CNR for the VistaScan and Express systems. The exposure of PSP plates to light can lead to unnecessary retakes and increased patient exposure to X-rays.

3.
Braz. dent. j ; Braz. dent. j;34(4): 150-157, July-Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520332

RESUMO

Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Resumo Este estudo teve como objetivo avaliar a influência do formato do arquivo nos parâmetros de qualidade de imagem (ruído de imagem, brilho e uniformidade) de radiografias periapicais adquiridas com diferentes sistemas digitais. As imagens radiográficas de um fantoma de acrílico foram adquiridas com dois sistemas digitais - Digora Toto e Express, e exportadas em cinco formatos de arquivo diferentes - TIFF, BMP, DICOM, PNG e JPEG. O ruído da imagem, o brilho da imagem (média dos valores de cinza) e a uniformidade da imagem (desvio padrão dos valores de cinza) foram avaliados em todas as imagens. A análise de variância (ANOVA) bidirecional com o teste post-hoc de Tukey foi aplicada para comparar os resultados, considerando os formatos de arquivo e os sistemas radiográficos como os fatores estudados. Um nível de significância de 5% foi adotado para todas as análises. O formato de arquivo de imagem DICOM apresentou menor ruído de imagem, maior brilho (maiores valores médios de cinza) e maior uniformidade de imagem (p<0,001) do que os outros formatos de arquivo, que não diferiram entre si para ambos os sistemas de radiografia digital (p>0,05). O sistema Express apresentou menor ruído de imagem e maior uniformidade de imagem que o sistema Digora Toto, independentemente do formato do arquivo de imagem (p<0,001). Além disso, o Express mostrou maior brilho do que o Digora Toto para todos os formatos de arquivo de imagem (p<0,001), exceto para o formato de arquivo de imagem DICOM, que não diferiu significativamente entre os sistemas de radiografia digital testados (p>0,05). O formato de arquivo de imagem DICOM mostrou menor ruído de imagem, maior brilho e maior uniformidade de imagem do que os outros formatos de arquivo (TIFF, BMP, PNG e JPEG) em ambos os sistemas de radiografia digital testados.

4.
Int. j. morphol ; 41(4): 1101-1106, ago. 2023. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1514325

RESUMO

La investigación tuvo como objetivo determinar la influencia de la morfología externa de la raíz de primeros premolares superiores en la existencia de sobreestimación radiográfica durante la preparación para poste. Con este fin se realizó un estudio transversal in vitro, donde 60 premolares superiores uniradiculares fueron instrumentadas con fresas Gates Glidden y Pesso de calibre 1, 2 y 3. Seguidamente se obtuvieron imágenes radiográficas digitales de cada pieza dentaria mediante un aparato posicionador a una distancia constante en sentido vestíbulo lingual, asimismo se realizaron imágenes tomográficas volumétricas de las muestras. En ambas técnicas imagenológicas se midió el espesor a mesial y distal de las piezas. La sobreestimación fue calculada mediante la diferencia de la medida tomográfica menos la radiográfica. Los resultados indicaron que en ambas paredes radiculares hubo diferencia significativa entre las medidas radiográficas y tomográficas (p<0,05), encontrándose en la pared distal diferencias altamente significativas (p<0,001); además se evidenció que la sobreestimación radiográfica fue mayor en la pared distal. El estudio concluyó que existe sobreestimación radiográfica en premolares superiores durante la preparación para poste de un 20,42 % en promedio, siendo la pared distal la estructura que presenta mayor sobreestimación.


SUMMARY: he investigation´s objective was to determine the influence of external morphology of the root of upper first premolars in the existence of radiographic overestimation during preparation for post. An in vitro cross-sectional study was carried out, where 60 single-rooted upper premolars were instrumented with burs. Gates Glidden and Pesso of caliber 1, 2 and 3, then, digital radiographic images of each dental piece were obtained by means of a positioning device at a constant distance in the buccolingual direction; volumetric tomographic images of the samples were also performed. In both imaging techniques, the mesial and distal thickness of the pieces was measured. The overestimation was calculated by the difference of the tomographic measurement minus the radiographic one. The results indicated that in both root walls there was a significant difference between the radiographic and tomographic measurements (p<0.05), with highly significant differences being found in the distal wall (p<0.001); In addition, it was evidenced that the radiographic overestimation was greater in the distal wall. The study concluded that there is radiographic overestimation in upper premolars during post preparation of 20.42% on average, with the distal wall being the structure that presents the greatest overestimation.


Assuntos
Humanos , Dente Pré-Molar/diagnóstico por imagem , Preparo do Dente , Cavidade Pulpar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Dente Pré-Molar/anatomia & histologia , Intensificação de Imagem Radiográfica , Estudos Transversais , Técnica para Retentor Intrarradicular , Preparo de Canal Radicular , Cavidade Pulpar/anatomia & histologia
5.
Braz. dent. j ; Braz. dent. j;34(1): 39-44, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420574

RESUMO

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

6.
Acta odontol. Colomb. (En linea) ; 13(1): 26-39, 20230000. ilus, ilus, tab, tab
Artigo em Espanhol | LILACS | ID: biblio-1425208

RESUMO

Objetivo: establecer la relación entre el diagnóstico histopatológico de sacos foliculares de terceros molares y la medida radiográfca estandarizada en radiografía panorámica digital. Métodos: se llevó a cabo un estudio descriptivo en el que se incluyeron 28 sacos foliculares de terceros molares. Dos observadores midieron la radiolucidez pericoronal en radiografías panorámicas digitales usando un método estandarizado y se calculó el índice de correlación intraclase. Se estableció un diagnóstico radiográfco según la medida del saco, con <2.5 mm como el límite para sacos foliculares normales. Dicho diagnóstico fue comparado con el respectivo diagnóstico histopatológico. Se calculó sensibilidad y especifcidad; se aplicó la prueba de chi-cuadrado, exacta de Fisher y, fnalmente, el índice Kappa. Resultados: se obtuvo un alto grado de acuerdo entre los observadores. La prueba radiográfca tuvo una baja sensibilidad (0.27) y especifcidad (0.6) y no se encontró diferencia estadísticamente signifcativa entre estos. Conclusiones: la ausencia de hallazgos radiográfcos no implica ausencia de enfermedad. Además, no se puede establecer relación entre la presencia de quistes dentígeros y radiolucidez ≥ 2.5 mm en radiografía panorámica digital.


Objective: To establish the relationship between the histopathological diagnosis of follicular sacs of third molars and the standardized radiographic measurement in digital panoramic radiography. Methods: This was a descriptive study in which 28 follicular sacs of third molars were included. In digital panoramic radiographs two observers measured the pericoronal radiolucency using a standardized method and the intraclass correlation index was calculated. A radiographic diagnosis was established according to the size of the sac, with <2.5mm being the limit for normal follicular sacs. This diagnosis was compared with the respective histopathological diagnosis. Sensitivity and specifcity were calculated; the chi-square test, Fisher's exact test and fnally the Kappa index were applied. Results: A high degree of agreement was obtained among the observers. The radiographic test had a low sensitivity (0.27) and specifcity (0.6) and no statistically signifcant diference was found between these. Conclusions: The absence of radiographic fndings does not imply absence of disease, furthermore, no relationship can be established between the presence of dentigerous cysts and radiolucency ≥ 2.5 mm in digital panoramic radiography.


Assuntos
Humanos , Adulto , Cisto Dentígero , Dente Serotino , Patologia , Radiografia Panorâmica , Cistos
7.
Odovtos (En línea) ; 24(3)dic. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1406166

RESUMO

Abstract The aim of this study was to assess the use of digital dental radiology in Brazil, by focusing on the use of image receptors, imaging exams and digital image enhancement tools, also assessing the methods of professional image transfer. Questionnaires were distributed in person on dental meetings and digitally via messaging (WhatsApp®) and mailings list. The sample of this cross-sectional study consisted of 478 questionnaires. Most participants were woman (n=315, 65.9%), with average age of 33.8±9.2 years. Descriptive and frequency analysis was performed. Chi-square and Fisher's exact tests were used (α=0.05). Most dentists worked at shared dental clinics (34.7%) and use digital image receptors (51.1%), but a representative percentage (48.9%) still exclusively use radiographic films. Photostimulable phosphor plate is the most used digital image receptor. Among extraoral exams, panoramic radiography (PAN) is the most used. Regarding dental specialties, oral radiologists and oral and maxillofacial surgeons mostly use cone-beam computed tomography (p<0.001). Most dentists who use digital systems make use of digital image enhancement tools (87.8%), mainly contrast, zoom, brightness and measurements. The most common method of professional image transfer (professional-professional and professional-patiens) is by email, with few dentists using online app and social media (26%). Therefore, while most Brazilian dentists use digital imaging systems, a significant percentage still exclusively use radiographic films. The most extraoral imaging exams used is PAN. Regarding image enhancement tools, brightness and contrast adjustments, zoom and measurements are the most applied. Finally, dentists generally use email for professional image transfer.


Resumen El objetivo de este estudio fue evaluar uso de la radiología dental digital en Brasil, centrándose en uso de receptores de imagen, exámenes de imágenes y herramientas de mejora de imagen digital, evaluando también los métodos de transferencia de imagen profesional. Cuestionarios se distribuyeron de forma presencial en reuniones odontológicas y de forma digital a través de mensajería (WhatsApp®) y lista de correo. Muestra de este estudio transversal estuvo compuesta por 478 cuestionarios. Mayoría de los participantes eran mujeres (n=315, 65,9%), con edad promedio de 33,8±9,2 años. Se realizó un análisis descriptivo y de frecuencias. Se utilizaron las pruebas Chi-cuadrado y exacta de Fisher (α=0,05). La mayoría de los odontólogos trabajaban en clínicas dentales compartidas (34,7%) y utilizan receptores de imágenes digitales (51,1%), pero un porcentaje representativo (48,9%) todavía utiliza exclusivamente películas radiográficas. Placa de fósforo fotoestimulable es el receptor de imagen digital más utilizado. Entre los exámenes extraorales, la radiografía panorámica (PAN) es la más utilizada. En cuanto a las especialidades odontológicas, los radiólogos orales y los cirujanos orales y maxilofaciales utilizan mayoritariamente la tomografía computarizada de haz cónico (p<0,001). Mayoría de los odontólogos que utilizan sistemas digitales utilizan herramientas de mejora de imagen digital (87,8%), principalmente contraste, zoom, brillo y medidas. Método más común de transferencia de imágenes profesionales (profesional-profesional y profesional-pacientes) es por correo electrónico, con pocos dentistas que utilizan aplicaciones en línea y redes sociales (26%). Por lo tanto, mientras que la mayoría de dentistas brasileños utilizan sistemas de imágenes digitales, un porcentaje significativo aún utiliza exclusivamente películas radiográficas. Examen de imagen extraoral más utilizado es el PAN. En cuanto a las herramientas de mejora de imagen, los ajustes de brillo y contraste, el zoom y las medidas son las más aplicadas. Finalmente, los dentistas generalmente usan el correo electrónico para la transferencia de imágenes profesionales.


Assuntos
Intensificação de Imagem Radiográfica/tendências , Sistemas de Informação em Radiologia , Brasil , Diagnóstico por Imagem
8.
Clin Oral Investig ; 26(7): 4743-4752, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35267096

RESUMO

OBJECTIVES: To evaluate the influence of digital filters of intraoral radiographic systems on the diagnosis of simulated internal and external root resorptions and image quality. MATERIALS AND METHODS: Internal root resorption (IRR) and external root resorption (ERR) were simulated in 34 teeth. For image acquisition, two radiographic systems were used: Digora Toto and VistaScan. All filters available in these systems were applied. Three observers scored the detection of root resorptions in a 5-point scale. The noise and the contrast-to-noise ratio (CNR) were calculated. The area under ROC curve, sensitivity, specificity, and accuracy were obtained. One-way ANOVA with Tukey's post hoc tests compared the diagnostic values, noise, and CNR between the filters (α = 0.05). RESULTS: For ERR, there were no significant differences in diagnostic values between the filters tested for both systems. For IRR, Original and Noise Reduction filters presented higher sensitivity than the Sharpen2 filter for images from Digora Toto, with no differences between the other groups. For VistaScan, there were no significant differences of diagnostic values between the groups studied. Noise values differed among the filters of both systems. The CNR of the filters differed only for the bone region for Digora Toto, while for VistaScan, both tooth and bone regions differed. CONCLUSIONS: Despite promoting changes in pixel intensities and affecting the noise level of the radiographic images, the digital filters of Digora Toto and VistaScan systems do not affect the diagnosis of internal or external root resorptions. CLINICAL RELEVANCE: Digital filters are common tools in digital radiographic systems and may be used by the professional without impairment in root resorptions diagnosis.


Assuntos
Reabsorção da Raiz , Humanos , Curva ROC , Radiografia Dentária Digital/métodos , Reabsorção da Raiz/diagnóstico por imagem , Raiz Dentária
9.
Dentomaxillofac Radiol ; 51(4): 20210404, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34860568

RESUMO

OBJECTIVES: To assess the dynamic range and enhancement ability of radiographs acquired with contemporary digital systems. METHODS: Five repeated periapical radiographs of human mandibles with an aluminium step-wedge were acquired using two sensor-based and three photostimulable phosphor plate-based systems and an X-ray unit at ten exposure times 0.020, 0.032, 0.063, 0.080, 0.100, 0.200, 0.320, 0.400, 0.500, and 0.630 s. All images had their brightness and contrast enhanced by two experienced oral and maxillofacial radiologists in consensus and were exported as both the original and enhanced file formats. Mean grey values were obtained from the aluminium steps and tabulated with their corresponding thicknesses for each exposure time, digital radiographic system, and file format. Images with saturated steps were excluded and the mean grey values from the remaining images were averaged to assess image brightness and the angular coefficient of the linear trendlines was generated from the relationship between mean grey values and their corresponding aluminium thicknesses to assess image contrast. Brightness and contrast values were compared using two-way ANOVA with post-hoc Tukey (α = 0.05). RESULTS: Photostimulable phosphor plate-based digital radiographic systems had a broader dynamic range. Longer exposure times produced original images with lower brightness and variable contrast (p < 0.05). Subjective enhancement significantly increased or reduced brightness and/or contrast in some systems (p < 0.05). CONCLUSIONS: Contemporary digital radiographic systems present different dynamic ranges and exposure-related brightness and contrast. Image enhancement may be a valuable tool at slightly suboptimal exposure times.


Assuntos
Alumínio , Radiografia Dentária Digital , Humanos , Mandíbula , Intensificação de Imagem Radiográfica/métodos , Radiografia Dentária Digital/métodos
10.
Oral Radiol ; 38(4): 452-458, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34626307

RESUMO

OBJECTIVE: To evaluate the influence of the file format of digital periapical radiographs on the diagnosis of vertical root fracture (VRF). STUDY DESIGN: Periapical radiographic images of 34 single-rooted teeth-19 with VRF, and 15 without VRF were acquired using two digital systems-Digora Toto, and Digora Optime, and exported into four different file formats-TIFF, BMP, PNG, and JPEG, totaling 272 radiographs. The radiographs were assessed by five examiners for the detection of VRF, using a 5-point scale (1-definitely absent; 2-probably absent; 3-uncertain; 4-probably present; 5-definitely present). Diagnostic values of area under the ROC curve, specificity, and sensitivity for the diagnosis of VRF were calculated. The results were compared by two-way Analysis of Variance with post hoc Tukey's test. The intra- and inter-examiner agreements were measured by the Kappa test. The significance level was set at 5% for all analyses. RESULTS: The values of intra-examiner agreement varied from moderate (0.56) to almost perfect (0.81), while the values of inter-examiner agreement varied from fair (0.29) to moderate (0.60). The image file format did not influence the diagnostic values for VRF for any of the radiographic systems tested (p > 0.05). Digora Toto had significantly greater values of area under the ROC curve than Digora Optime for all file formats (p = 0.001). CONCLUSION: The image file format of periapical radiographs does not influence the diagnosis of VRF, regardless of the digital radiography system.


Assuntos
Fraturas dos Dentes , Humanos , Compostos de Quinolínio , Radiografia , Radiografia Dentária Digital/métodos , Tiazóis , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem
11.
Dentomaxillofac Radiol ; 51(4): 20210314, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34767483

RESUMO

OBJECTIVES: This study aimed to evaluate the impact of enhancement filters in detecting small simulated internal root resorptions (IRR). METHODS:: Forty-two extracted human teeth were sectioned, connected, and stored in a dry human jaw and X-rayed with photostimulable phosphor plates (PSPs), composing the control group (CG). In the middle-third of the root canals, IRR lesions were simulated using Da Silveira protocol. Later, the specimens were X-rayed to create the test group (TG). All images acquired were exported with seven enhancement filters plus the original image. Three examiners used a five-point Likert scale to evaluate the images regarding the presence/absence of IRR. Diagnostic efficacy was assessed from sensitivity and specificity results. Comparison among filters was performed by using receiver operating characteristic (ROC) curve analysis. RESULTS:: Moderate values of Kappa interexaminer (0.403-0.620) and high values of Kappa intraexaminer (0.757-0.915) were observed. The best performance occurred in the CG (p < 0.05). Original images presented the greatest sensitivity and area under the ROC curve (0.595-0.750), while the Endo filter presented the greatest specificity (0.952). Inversion and Pseudo-3D images produced the greatest doubt in the diagnosis, significant for CG with the Pseudo-3D filter (p < 0.05). CONCLUSIONS:: The Original and 'Endo' filters should be chosen as it offers greater diagnostic ability and allows more confidence during the evaluation.


Assuntos
Reabsorção da Raiz , Humanos , Curva ROC , Radiografia , Radiografia Dentária Digital/métodos , Reabsorção da Raiz/diagnóstico por imagem , Sensibilidade e Especificidade
12.
Oral Radiol ; 38(2): 234-239, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34195932

RESUMO

OBJECTIVE: To evaluate the diagnostic efficacy of the combined assessment of the original radiographic image with the Invert or Emboss digital enhancement filters in periapical radiographs obtained with different horizontal projection angles in the detection of simulated dental root fracture. MATERIALS AND METHODS: Thirty-four single-rooted teeth were selected, out of which 17 teeth were subjected to root fracture. Each tooth was individually placed in an empty socket of a dry human maxilla or mandible and X-rayed following the paralleling technique at three horizontal projections: mesial, right angle, distal. Then, the Invert and Emboss enhancement filters were applied. Five examiners independently evaluated all the images and rated the fractures using a 5-point scale. Weighted kappa test assessed the intra- and interexaminer agreements. Diagnostic values were calculated and the areas under the receiver operating characteristic curve (AUC) were compared using two-way ANOVA with Tukey test as post hoc (α = 0.05). RESULTS: The inter- and intraexaminer agreement ranged from moderate to almost perfect and from substantial to almost perfect, respectively. Diagnostic values were considerably high for all conditions with no significant difference between the AUC values (p > 0.05). CONCLUSIONS: The combined use of the original radiographic image with the Invert or Emboss digital enhancement filters in periapical radiographs obtained with different projection angles did not influence the detection of simulated dental root fracture.


Assuntos
Radiografia Dentária Digital , Dente , Tomografia Computadorizada de Feixe Cônico , Humanos , Radiografia , Radiografia Dentária Digital/métodos , Raiz Dentária/diagnóstico por imagem
13.
Dentomaxillofac Radiol ; 50(7): 20200578, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33835867

RESUMO

OBJECTIVE: To compare the diagnostic efficacy of different devices for visualizing digital images in detecting simulated internal root resorption (IRR). METHODS: 26 uniradicular human teeth were sectioned along its long axis and randomly divided into two groups. Then, they were submerged in hydrochloric acid (HCl) P.A 37% at different times to make two types of defects: Type 1 (2 hours), and type 2 (3 hours). Digital periapical radiographs were acquired in three moments: before section, after section and after immersion in acid. The images were evaluated on three different devices: 27-inch iMac Desktop, 8-inch Android Tablet, and 5.5-inch iPhone 8 Plus using a 5-point scale. RESULTS: The sensitivity and accuracy values were higher with the use of the Android Tablet, for both types of defects. For the values of the area under ROC curve, higher results were observed with the Android Tablet and lower results with the iMac, showing a significant difference (p < 0.05) when comparing the use of the iMac with the Android Tablet and iPhone 8, for type 1 defects. When comparing the different devices, in the evaluation of images of type 2 defects, the values showed no statistical difference, regardless of the device evaluated (p > 0.05). CONCLUSIONS: The size of the lesion interferes with the detection capacity in the image. However, the use of portable devices does not impair the diagnosis of IRR, regardless of size and the dental practioners may use different devices/display, under optimal viewing conditions, to detect IRR lesions, without jeopardizing the diagnostic ability.


Assuntos
Reabsorção da Raiz , Humanos , Curva ROC , Radiografia Dentária Digital
14.
Rev. argent. radiol ; 85(2): 33-40, abr. 2021. tab, graf
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-1288197

RESUMO

Resumen Objetivo: Evaluar la diferencia del trazado cefalométrico manual con el digital en radiografías laterales de cráneo. Materiales y métodos: Inicialmente se realizó un piloto para calibrar al investigador principal, en donde se analizaron 10 radiografías pertenecientes a cinco pacientes del Servicio de Radiología del Centro Odontológico de nuestra institución para evaluar la concordancia entre los dos evaluadores y establecer el tamaño de la muestra. Finalmente, se analizaron 78 radiografías cefalométricas de 39 pacientes, en las que se realizó el trazado cefalométrico de Steiner manual y digital. Esas radiografías se analizaron en una escala 1:1 y posteriormente se evaluó la diferencia de las mediciones mediante el análisis univariado, se determinó en mediana e intervalo intercuartil por separado. En el análisis bivariado, se aplicó la prueba de signo de rangos de Wilcoxon y muestras pareadas para determinar la diferencia de las mediciones cefalométricas de Steiner entre el tipo del análisis cefalométrico. El nivel de significancia se fijó en p < 0,05 y confiabilidad al 95%, respectivamente. Resultados: No hubo diferencia significativa en la mayoría de las mediciones hechas de manera manual y digital, siendo el ángulo interincisal la única medición angular en la cual hubo diferencia significativa al obtener un resultado de p = 0,002. Mientras tanto, en las mediciones lineales, la única medición en la que hubo diferencia significativa fue en el segmento incisivo inferior - NB con p = 0,005. Conclusión: No se encuentran diferencias significativas entre el trazado cefalométrico manual y el digital. No obstante, es importante tener en cuenta que la muestra o población evaluada es reducida para definir conclusiones.


Abstract Objective: To evaluate the difference of the manual cephalometric tracing with the digital tracing on lateral cranial radiographs. Materials and Methods: Initially, a pilot study was carried out to calibrate the principal investigator, where 10 radiographs belonging to 5 patients of the Radiology Service of the Dental Center, were analyzed to evaluate the intraclass concordance between the two evaluators. To establish the size of the sample, finally, 78 cephalometric radiographs of 39 patients were analyzed, in which the manual and digital Steiner cephalometric tracing was performed. These radiographs were analyzed on a 1: 1 scale and then the difference of the measurements was evaluated using the univariate analysis, which was determined in the median and interquartile range, separately. In the bivariate analysis, the Wilcoxon rank sign test and paired samples were applied to determine the difference of Steiner's cephalometric measurements between the cephalometric analysis type. The level of significance was set at p < 0.05 and 95% reliability, respectively. Results: There was no significant difference in most of the measurements made manually and digitally. The interincisal angle the only angular measurement in which there was a significant difference when obtaining a result of p = 0.002, while, in the linear measurements, the only measurement in which there was significant difference was in the lower incisor segment - NB with p = 0.005. Conclusion: There is no significant difference between manual and digital cephalometric tracing, nevertheless it is important to keep in mind that the simple or population evaluated is reduced to define conclusions.


Assuntos
Humanos , Adolescente , Adulto , Pessoa de Meia-Idade , Cefalometria , Radiografia Dentária Digital , Pacientes , População , Radiologia , Pesquisadores , Crânio , Radiografia Dentária , Projetos Piloto , Organizações , Tamanho da Amostra , Incisivo , Métodos
15.
Dentomaxillofac Radiol ; 50(6): 20200339, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33411592

RESUMO

OBJECTIVES: To develop and test a protective device (PD) to increase the resistance of photostimulable storage phosphor (PSP) plate to compressive load, and assess the resulting image quality. METHODS: Two prototypes, polyvinylchloride sheets of 0.3 mm and 0.7 mm each, were developed for PSP plate size 2. The resistance to compressive load was tested using eight new PSPs divided into four test groups: (1) PSP, (2) PSP and paperboard protector, (3) PSP and 0.3 mm PD, and (4) PSP and 0.7 mm PD. The resulting images were analyzed by three oral radiologists, based on the consensus for image artifacts. Additionally, the objective image quality test was performed with four new PSPs, using an 8-step wedge aluminum scale. The mean gray values and standard deviation were measured in a total of 240 images, and the data were analyzed using analysis of variance with Bonferroni post-hoc test. RESULTS: Artifacts were seen in the PSP control group starting at 40 n, and at 150 n, 175 n and 300 n in 0.3 mm PD, paperboard protector and 0.7 mm PD, respectively. Although there was no statistical difference among groups, there were differences between exposure times (0.06-0.25 s, 0.06-0.40 s, and 0.10-0.40 s). Scanning resolution of 20 lp/mm showed higher mean gray value than 25 and 40 lp/mm (p < 0.05). CONCLUSION: The developed PDs improved the PSP resistance to compressive forces, with low interference on the pixel gray values, regardless of exposure time and spatial resolution. Nevertheless, the 0.7 mm PD could withstand the maximum compressive load.


Assuntos
Artefatos , Radiografia Dentária Digital , Placas Ósseas , Humanos , Equipamentos de Proteção , Intensificação de Imagem Radiográfica
16.
Clin Oral Investig ; 25(8): 4941-4948, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33495894

RESUMO

OBJECTIVES: To evaluate the influence of different image file formats of digital radiographic images on the diagnosis of external (ERR) and internal root resorption (IRR). MATERIALS AND METHODS: Thirty-four human teeth were selected. For ERR, 20 teeth were used (10 control and 10 with simulated ERR), and for IRR, 14 teeth were used (before and after IRR simulation). Digital periapical radiographs were acquired using the Digora Toto system and exported in four different image file formats: TIFF, BMP, PNG, and JPEG, totaling 192 radiographs. Five examiners evaluated the images using the JPEGView software and scored the detection of ERR or IRR on a 5-point scale. Sensitivity, specificity, accuracy, and the area under the ROC curve were obtained for the diagnosis of ERR and IRR in the different image file formats. Two-way ANOVA compared the diagnostic values between the file formats and the Kappa test assessed intra- and inter-examiner agreement. The significance level was set at 5% (α = 0.05). RESULTS: The mean values of intra-examiner agreement were substantial (0.740) for ERR and almost perfect (0.836) for IRR and, inter-examiner was fair (0.263) and moderate (0.421), respectively. No statistically significant differences were found among the different file formats for the diagnostic values of ERR and IRR. CONCLUSION: The file format of digital radiographs does not influence the diagnosis of ERR and IRR. CLINICAL RELEVANCE: Digital radiographic images may be susceptible to computational factors; however, they can be stored in multiple file formats without affecting the diagnosis of dental root resorptions.


Assuntos
Reabsorção da Raiz , Humanos , Radiografia Dentária Digital , Reabsorção da Raiz/diagnóstico por imagem
17.
Dentomaxillofac Radiol ; 50(4): 20200295, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33141626

RESUMO

OBJECTIVES: To evaluate four different teaching methodologies in the radiographic diagnosis of proximal carious lesions and in the students' perception of these methodologies. METHODS: 71 undergraduate dental students were subdivided into 4 groups according to the teaching methodologies used (traditional, hybrid, e-learning and problem-based learning). All methods were applied by two properly trained researchers. Initially, students completed a pre-methodology test (index test). After applying the teaching methodologies, the students were submitted to a post-methodology test containing periapical radiographs for evaluation of proximal carious lesions. Then, the students answered a questionnaire to verify their perception of the different teaching methodologies. Statistical analysis was done. RESULTS: There were no relationship between the results of pre- and post-methodologies tests, irrespective of the teaching methodology employed (p > 0.05). No differences between the teaching methodologies studied (p > 0.05) were found regarding the amount of correct answers. However, the students who participated in the active (e-learning and problem-based learning) and hybrid teaching methodology reported a positive impact in relation to their diagnostic skills at the questionnaire. CONCLUSIONS: All the tested methodologies had a similar performance; however, the traditional methodology showed less acceptance by the students when analyzed subjectively and comparatively. The results of the present study increase comprehension about teaching methodologies for radiographic diagnosis of proximal carious lesions, and there is a potential to build on the knowledge base and provide practical support for students and educators.


Assuntos
Cárie Dentária , Educação em Odontologia , Cárie Dentária/diagnóstico por imagem , Avaliação Educacional , Humanos , Aprendizagem , Inquéritos e Questionários
18.
Dentomaxillofac Radiol ; 49(4): 20190384, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32027521

RESUMO

OBJECTIVES: To access the influence of the addition of a lead foil to intraoral digital radiographic receptors on image contrast and approximal caries lesions diagnosis. METHODS: 40 posterior teeth were distributed in silicone phantoms composed of two premolars, two molars and a non-test canine. Radiographic images of the phantoms were obtained with and without the incorporation of a lead foil, using the Digora Optime and Digora Toto systems. Four observers scored the images for the presence of caries lesions, using a 5-point scale. Images of an aluminum step wedge were acquired with and without the incorporation of a lead foil. Gray values and standard deviation of gray values were calculated in different thickness of the step wedge and, then, contrast variation was calculated. RESULTS: Presence of a lead foil did not influence caries lesions diagnostic values, regardless of the type of digital system (p > 0.05). In general, the objective analysis was not influenced by the presence of a lead foil in any of the tested systems (p > 0.05). However, Digora Toto images showed greater gray values, lower standard deviation of gray values and lower contrast variation, regardless of the presence of the lead foil (p < 0.05). CONCLUSIONS: The addition of a lead foil to intraoral digital receptors did not influence image contrast nor caries lesions diagnosis.


Assuntos
Cárie Dentária/diagnóstico por imagem , Radiografia Dentária Digital , Dente Pré-Molar/diagnóstico por imagem , Humanos , Dente Molar , Variações Dependentes do Observador , Imagens de Fantasmas , Curva ROC
19.
Rev. clín. periodoncia implantol. rehabil. oral (Impr.) ; 12(2): 77-80, ago. 2019. tab, graf, ilus
Artigo em Espanhol | LILACS | ID: biblio-1020665

RESUMO

RESUMEN: Objetivo: comparar la radiopacidad de distintos cementos de resina y corroborar si cumplen con los requisitos de normativas ISO. Material y método: Se prepararon muestras de 1 mm de grosor de los cementos de resina: RelyX U200 (3M ESPE), Calibra (Dentsply Sirona), Calibra Universal (Dentsply Sirona) y Bifix SE (VOCO). Las muestras fueron radiografiadas junto a una cuña de aluminio escalonada. Las imágenes fueron analizadas para determinar el valor en escala de grises y su respectivo valor en mm de Al. Los datos fueron analizados para comparar la radiopacidad de los materiales entre sí y con los requisitos establecidos por normas ISO. Resultados: La radiopacidad equivalente en mm de Al en orden descendiente fue de 2,84 ± 0,18 para Calibra, 2,37 ± 0,15 para Bifix SE, 2,26 ± 0,14 para Calibra Universal y de 1,67 ± 0,07 para RelyX U200. Estos valores son todos mayores al mismo grosor de aluminio exigido por la norma ISO 4049. Se establecieron diferencias estadísticamente significativas entre los cementos. Conclusiones: Se determinó que existen diferencias en la radiopacidad entre los cementos de resina compuesta estudiados. Sin embargo, todos los cementos evaluados cumplen con la norma ISO-4049 de radiopacidad.


ABSTRACT: Objective: Compare the radiopacity of different resin cements and verify their compliance with the requirements of ISO regulations. Material and method: Samples -10 mm in diameter and 1 mm thickness- of the resin cements RelyX U200 (3M ESPE), Calibra (Dentsply Sirona), Universal Calibra (Dentsply Sirona) and Bifix SE (VOCO) were prepared. Radiographies of the samples with a stepped aluminum wedge were obtained. For each sample, the grayscale and mm of Al values were calculated. The data were analyzed to compare the radiopacity of the materials and to contrast them with the requirements established by ISO standards. Results: The equivalent radiopacity in mm of Al in descending order was 2.84 ± 0.18 for Calibra, 2.37 ± 0.15 for Bifix SE, 2.26 ± 0.14 for Calibra Universal and 1.67 ± 0.07 for RelyX U200. These values exceed the value required by ISO 4049 standard. Statistically significant differences were established between the cements. Conclusion: There are differences in the radiopacity of the resin cements studied. However, all the cements complied with ISO 4049 radiopacity standards.


Assuntos
Radiologia , Guias como Assunto , Resinas Compostas , Radiografia Dentária Digital
20.
Oral Dis ; 25(7): 1809-1814, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31206959

RESUMO

OBJECTIVE: To assess the influence of subjective enhancement of brightness and contrast of digital panoramic radiographs on the detection of soft tissue calcifications. MATERIALS AND METHODS: In this observational study, 500 digital panoramic radiographs were evaluated by two examiners in consensus, who scored the images for the presence of calcifications for each right and left side of the image. After 30 days, all images were revaluated under subjective manipulation of digital brightness and contrast. Calcifications were classified based on the diagnostic hypothesis: sialolith, tonsillolith, calcified atheroma, phlebolith, rhinolith, maxillary sinus antrolith, synovial chondromatosis, lymph node calcification, stylohyoid ligament, triticeous cartilage, or/and upper horn of thyroid cartilage calcification. For intra-examiner agreement, 20% of the sample was reevaluated. The Kappa test and McNemar test were used (α = 0.05). RESULTS: In original images, calcifications were observed in 44.2% of the patients, and in enhanced images, this number was 70.8%. Many calcifications were detected only in enhanced images, mainly in the diagnostic hypotheses of calcified atheroma and stylohyoid ligament. Intra-examiner agreement was excellent for the detection of soft tissue calcifications (0.82) and for the classification (0.81). CONCLUSION: Subjective enhancement of brightness and contrast alters the detection of soft tissue calcifications in digital panoramic radiograph.


Assuntos
Calcinose/diagnóstico por imagem , Radiografia Dentária Digital , Radiografia Panorâmica/métodos , Adulto , Idoso , Cartilagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço , Doenças Faríngeas , Radiografia Panorâmica/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA