Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
SAGE Open Med Case Rep ; 12: 2050313X241272576, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39161922

RESUMO

Pregnant women with end-stage kidney disease who undergo peritoneal dialysis have lower pregnancy rates and higher obstetric risk than their peers undergoing hemodialysis. Although there has been some improvement in pregnancy rates and outcomes due to the intensification of dialysis prescriptions, there is currently a lack of guidelines for optimizing peritoneal dialysis regimens for pregnant women with end-stage kidney disease. Besides, there is limited data available regarding pregnancy outcomes in women with end-stage kidney disease undergoing peritoneal dialysis. We report the case of a 23-year-old Hispanic woman with end-stage kidney disease caused by focal and segmental glomerulosclerosis. She became pregnant while undergoing successful treatment with an intensified automated peritoneal dialysis regimen. The patient gave birth to a live female preterm infant weighing 938 g during the 28th week of her pregnancy. The baby required neonatal intensive care due to prematurity, extremely low birth weight, and respiratory distress syndrome.

2.
Rev. invest. clín ; Rev. invest. clín;75(6): 318-326, Nov.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1560117

RESUMO

ABSTRACT Home hemodialysis (HD) and automated peritoneal dialysis (APD) have advantages over HD in hospitals or HD centers. Home therapies are generally less expensive and give patients greater mobility and freedom for work, school, family, and recreational activities. Technological advances have made it possible to complement APD with devices for remote monitoring (RM) of the patient. With them, objective information generated in the APD device is collected and sent to repositories "in the cloud" for analysis or at the time decided by the health team. With APD+RM, it is possible to monitor therapeutic compliance, effective dialysis time, ultrafiltration volumes, inflow and outflow patterns of dialysis fluid, and patient actions to respond to alarms that indicate deviations from the parameters set by the nephrologist. The results of APD+RM show good acceptance by the patient, nephrologists, and nurses, treatment adherence has improved, hospitalizations and technique failure have decreased, and some aspects of quality of life have improved. However, there is a lack of controlled clinical trials that reliably demonstrate lower mortality and comorbidity due to specific causes.

3.
Rev Invest Clin ; 75(6): 318-326, 2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-37913763

RESUMO

Home hemodialysis (HD) and automated peritoneal dialysis (APD) have advantages over HD in hospitals or HD centers. Home therapies are generally less expensive and give patients greater mobility and freedom for work, school, family, and recreational activities. Technological advances have made it possible to complement APD with devices for remote monitoring (RM) of the patient. With them, objective information generated in the APD device is collected and sent to repositories "in the cloud" for analysis or at the time decided by the health team. With APD+RM, it is possible to monitor therapeutic compliance, effective dialysis time, ultrafiltration volumes, inflow and outflow patterns of dialysis fluid, and patient actions to respond to alarms that indicate deviations from the parameters set by the nephrologist. The results of APD+RM show good acceptance by the patient, nephrologists, and nurses, treatment adherence has improved, hospitalizations and technique failure have decreased, and some aspects of quality of life have improved. However, there is a lack of controlled clinical trials that reliably demonstrate lower mortality and comorbidity due to specific causes.


Assuntos
Falência Renal Crônica , Diálise Peritoneal , Humanos , Qualidade de Vida , Diálise Peritoneal/métodos , Diálise Renal , Hospitalização , Tecnologia , Falência Renal Crônica/terapia
4.
J Infect Public Health ; 16(10): 1619-1624, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37586134

RESUMO

BACKGROUND: Due to the health emergency of COVID-19, telemedicine has become more relevant. Remote monitoring conspicuous as a valuable tool for the clinical follow-up of kidney patients, in this case, who are treated with automated peritoneal dialysis. This study aims to describe the use of remote monitoring as a surveillance method in a cohort of patients on automated peritoneal dialysis prevent complications and COVID-19 contagion. METHODS: Study of a cohort of patients who initially participated in a randomized block clinical trial in which the use of Automated Peritoneal Dialysis with Remote Monitoring (APD-RM) was compared with conventional treatment. A descriptive analysis was performed of the rates of infection by COVID-19, the time of incidence until this, mortality, and rates of transfer to hemodialysis. In addition, survival was measured by survival curves. RESULTS: Of the 509 patients, 19 were positive for COVID-19 (incidence rate of 7.0 episodes/100 patient-year), and only six patients recovered from the infection; the death rate was 2.6 % compared to all-cause death of 9.8 %. The most affected group of patients were those over 50 years old, with 71.4 % mortality, in contrast to younger patients infected, with a mortality of 60 %. During the follow-up period, 21 patients were transferred to HD: six due to peritonitis, five due to UF failure, seven due to catheter dysfunction, one due to uremic syndrome, one due to COVID-19, and one by surgical intervention. CONCLUSION: APD-RM patients have a significant advantage over other dialysis therapies because the use of telemedicine not only provides continuity in the patient's clinical treatment but also favors the prevention of COVID-19 infection, the management and prevention of complications inherent to therapy and the preservation of the life of Peritoneal Dialysis patients.


Assuntos
COVID-19 , Diálise Peritoneal , Telemedicina , Humanos , Pessoa de Meia-Idade , COVID-19/etiologia , Diálise Peritoneal/efeitos adversos , Diálise Peritoneal/métodos , Diálise Renal , Monitorização Fisiológica/métodos , Telemedicina/métodos
5.
Blood Purif ; 52(7-8): 668-675, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37331338

RESUMO

INTRODUCTION: Automated peritoneal dialysis (APD) employs cyclers to control inflow and outflow of the dialysis fluid to the patient's abdomen. To allow more patients to use this modality, cyclers should support the achievement of an adequate dialysis dose and be easy to use, cost-effective, and silent. The new SILENCIA cycler (Fresenius Medical Care, Bad Homburg, Germany), designed to improve these characteristics in comparison to its predecessor device, was evaluated in this respect in a prospective study. METHODS: This cross-over study comprised two 2-week study periods, separated by a 3-week training phase. First, patients underwent APD with their current cycler (PD-NIGHT [Fresenius Medical Care, Bad Homburg, Germany] or HomeChoice Pro [Baxter, Deerfield, IL, USA] as control), followed by training on the SILENCIA cycler. Then, patients were switched to the SILENCIA cycler. During each treatment period, we collected data on total Kt/Vurea, ultrafiltration (UF) volume, patient-reported outcomes (sleep quality, among others), and device handling. RESULTS: Sixteen patients were enrolled; 2 patients terminated the study prematurely before study intervention, 1 patient due to a protocol violation. In 13 patients, total Kt/Vurea and UF could be evaluated. Neither Kt/Vurea nor UF differed significantly between control and SILENCIA cyclers. Out of 10 patients answering the questionnaire on sleep quality after the 2-week phase with the SILENCIA cycler, sleep quality improved in 5 patients; in the other patients, sleep quality was rated unchanged compared to the previously used cycler. The average reported sleep time was 5.9 ± 1.8 h with the PD-NIGHT, 7.2 ± 2.1 h with HomeChoice Pro, and 8.0 ± 1.6 h with the SILENCIA cycler. All patients were much or very much satisfied with the new cycler. CONCLUSION: The SILENCIA cycler delivers adequate urea clearance and UF. Importantly, sleep quality improved, possibly related to less caution messages and alarms.


Assuntos
Diálise Peritoneal , Diálise Renal , Humanos , Estudos Cross-Over , Estudos Prospectivos , Qualidade do Sono
6.
J. bras. nefrol ; 45(1): 17-26, Jan.-Mar. 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1430650

RESUMO

Abstract Introduction: Chronic kidney disease, more prevalent in the elderly, is considered a public health issue worldwide. Objective: To evaluate the impact of automated, peritoneal dialysis modalities, intermittent and continuous, on the inflammatory profile of elderly people with chronic kidney disease. Methods: Prospective, cross-sectional and analytical study carried out in a dialysis clinic in Brasília - Brazil, with 74 elderly people aged 60 years or older. The patients underwent rapid Peritoneal Equilibration Test, clinical assessment, blood collection for biochemical and cytokine assessments, interleukin 6 and transforming growth factor beta 1, and answered a quality-of-life questionnaire (KDQOL-SF36). We used a 5% significance level for data analysis, associations and correlations. Results: Patients in the continuous modality had higher serum values of transforming growth factor beta 1 than those in the intermittent modality, which had higher peritoneal transforming growth factor beta 1, age and residual renal function than those in continuous mode. Interleukin 6 dosage in the peritoneum was associated with age, while serum IL-6 was associated with IL-6 in the peritoneum, time on dialysis and age. There was no association between the modality and the presence of diabetes, blood volume or nutritional status. Both modalities enable good adaptation to the dialysis treatment. Conclusion: Inflammation in automated peritoneal dialysis is mainly associated with low residual renal function, advanced age and longer time on therapy, and not to the type of dialysis performed.


Resumo Introdução: A doença renal crônica, mais prevalente em idosos, é considerada um problema de saúde pública em todo o mundo. Objetivo: Avaliar o impacto das modalidades de diálise peritoneal automatizada, intermitente e contínua, no perfil inflamatório de idosos renais crônicos. Métodos: Estudo prospectivo, transversal e analítico realizado em uma clínica de diálise em Brasília, com 74 idosos com idade igual ou maior que 60 anos. Os pacientes foram submetidos ao Teste de Equilíbrio Peritoneal rápido, avaliação clínica, coleta de sangue para avaliações bioquímicas e de citocinas, interleucina 6 e fator de crescimento transformador beta 1, e questionário de qualidade de vida (KDQOL-SF36). Foram utilizadas para análise dos dados, associações e correlações com nível de significância de 5%. Resultados: Pacientes na modalidade contínua apresentaram valores séricos do fator de crescimento transformador beta 1 maiores do que os em modalidade intermitente. Estes apresentaram fator de crescimento transformador beta 1 no peritônio, idade e função renal residual maiores do que os em modalidade contínua. A dosagem da interleucina 6 no peritônio foi associada à idade, enquanto a IL-6 sérica foi associada à IL-6 no peritônio, ao tempo em diálise e à idade. Não houve associação entre a modalidade e a presença de diabetes, volemia ou estado nutricional. Ambas as modalidades permitem boa adequação à terapia dialítica. Conclusão: A inflamação na diálise peritoneal automatizada está associada principalmente à baixa função renal residual, à idade avançada e ao maior tempo em terapia, e não à modalidade de diálise realizada.

7.
Healthcare (Basel) ; 10(3)2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35327042

RESUMO

A breakthrough in peritoneal dialysis (PD) therapy occurred in 1977 with the development of continuous ambulatory peritoneal dialysis (CAPD). Its simplicity, low cost, and ease with which CAPD could be performed on patients at home contributed to the popularity of this procedure. However, there is a need for continuous improvement in building optimal systems for incident chronic kidney disease (CKD) patients. This research showed the design and construction of a simplified prototype of low-cost automated peritoneal dialysis (APD) equipment that meets international standards to automatically regulate infusion and fluid drainage in and out of a patient with low margins of error. Experimental tests allowed the adjustment of the RPM values concerning the flow rate provided. In addition, thanks to the pressure sensor, it was possible to observe a fluctuation ranging from 9 to 13 kPa, which is within the permissible average specified in the catalogs of medical instruments and equipment. Furthermore, a turbidity sensor was added to decrease the possibility of presenting peritonitis. The results showed absolute values of flow, angular velocity, and pressure that it could deliver for use in APD therapies. Finally, the construction of the APD equipment is presented generally, showing the electronic and mechanical components that constitute it.

8.
Perit Dial Int ; 40(4): 377-383, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32063181

RESUMO

BACKGROUND: The benefits of automated peritoneal dialysis (APD) have been established, but patient adherence to treatment remains a concern. Remote patient monitoring (RPM) programs are a potential solution; however, the cost implications are not well established. This study modeled, from the payer perspective, expected net costs and clinical consequences of a novel RPM program in Colombia. METHODS: Amarkov model was used to project costs and clinical outcomes for APD patients with and without RPM. Clinical inputs were directly estimated from Renal Care Services data or taken from the literature. Dialysis costs were estimated from national fees. Inpatient costs were obtained from a recent Colombian study. The model projected overall direct costs and several clinical outcomes. Deterministic and probabilistic sensitivity analyses (DSA and PSA) were also conducted to characterize uncertainty in the results. RESULTS: The model projected that the implementation of an RPM program costing US$35 per month in a cohort of 100 APD patients over 1 year would save US$121,233. The model also projected 31 additional months free of complications, 27 fewer hospitalizations, 518 fewer hospitalization days, and 6 fewer peritonitis episodes. In the DSA, results were most sensitive to hospitalization rates and days of hospitalization, but cost savings were robust. The PSA found there was a 91% chance for the RPM program to be cost saving. CONCLUSION: The results of the model suggest that RPM is cost-effective in APD patients which should be verified by a rigorous prospective cost analysis.


Assuntos
Custos de Cuidados de Saúde , Falência Renal Crônica/terapia , Monitorização Fisiológica/economia , Diálise Peritoneal/economia , Consulta Remota/economia , Adulto , Estudos de Coortes , Colômbia , Análise Custo-Benefício , Humanos
9.
Rev. cuba. pediatr ; 87(2): 205-215, tab
Artigo em Espanhol | LILACS, CUMED | ID: lil-751818

RESUMO

INTRODUCCIÓN: el Programa de diálisis peritoneal domiciliaria en Pediatría se inició en Cuba en el año 2008 en el Hospital Pediátrico Centro Habana, Centro de Referencia Nacional de Nefrología Pediátrica. OBJETIVO: evaluar el Programa durante 4 años de experiencia. MÉTODOS: se realizó un estudio descriptivo, de corte transversal, utilizando registros retrospectivos del Programa desde 2008 hasta 2012. RESULTADOS: se analizaron 16 pacientes; 9 niñas y 7 niños, con un promedio de edad de 11 años. La etiología más frecuente correspondió a malformaciones congénitas y enfermedades glomerulares primarias. Las complicaciones infecciosas representaron el 90 % del total, y de ellas, la infección del orificio de salida (57,5 %), con 1 episodio cada 23 meses/paciente. La incidencia de peritonitis fue de 1 episodio cada 12 meses/paciente. Predominaron cultivos positivos a bacterias grampositivas (63,3 %), el Staphylococcus coagulasa positivo spp. fue más común. La causa más frecuente de interrupción de la diálisis peritoneal lo constituyó el trasplante renal. El tiempo global de duración en diálisis peritoneal domiciliaria fue de 13,2 meses. Los pacientes que cambiaron de técnica estuvieron un promedio de 8 meses en el Programa. A pesar de que el tiempo del seguimiento del método dialítico aún es insuficiente, la probabilidad de no ocurrencia de la falla de la técnica a partir de los 18 meses fue de más de un 50 %. CONCLUSIONES: durante 4 años de experiencia la diálisis peritoneal domiciliaria demostró ser una alternativa factible de inicio de tratamiento dialítico para el paciente pediátrico con enfermedad renal crónica terminal.


INTRODUCTION: the program of peritoneal dialysis at home in pediatric patients started in Cuba in 2008 at Centro Habana's pediatric hospital which is the national center of reference in pediatric nephrology. OBJECTIVE: to evaluate the experiences in the implementation of the program in four years. METHODS: adescriptive, cross-sectional study using retrospective records of the program from 2008 to 2012. RESULTS: sixteen patients (9 girls and 7 children) aged 11 years as average was analyzed. The most frequent etiologies were congenital malformations and primary glomerular diseases. The infective complicdations accounted for 90 % of the total number, mainly the outlet orifice infection (57.5 %) with one event per 23 months/patient. The incidence of peritonitis was one event every 12 months/patient. Positive Gram-positive bacteria prevailed (63.3 %), being Staphylococcus coagulasa positive spp the most common. The most frequent cause of cessation of peritoneal dialysis use was renal transplantation. The overall length of time of periotoneal dialysis at home was 13.2. Those patients who moved to this technique were included in the program 8 months as an average. In spite of the fact that the follow-up period of the dialysis method is still insufficient, the probabilities of non-occurrence of any failure in this technique after 18 months were over 50 %. CONCLUSIONS: the experience gained in four years of using peritoneal dialysis at home proved that this is a feasible alternative for starting the dialysis-based treatment of the pediatric patient with terminal chronic renal disease.


Assuntos
Humanos , Criança , Hemodiálise no Domicílio/métodos , Transplante de Rim/métodos , Insuficiência Renal Crônica/complicações , Epidemiologia Descritiva , Estudos Transversais
10.
Perit Dial Int ; 33(3): 252-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23660606

RESUMO

INTRODUCTION: Automated assisted peritoneal dialysis (AAPD) has been shown to be successful as renal replacement therapy for elderly and physically incapable end-stage renal disease (ESRD) patients. In early 2003, a pioneer AAPD program was initiated at GAMEN Renal Clinic in Rio de Janeiro, Brazil. ♢ OBJECTIVE: We evaluated the results of an AAPD program offered as an option to elderly ESRD patients with physical or cognitive debilities or as last resort to patients with vascular access failure or hemodynamic instability during hemodialysis. ♢ METHODS: A cohort of 30 consecutive patients started AAPD from January 2003 to March 2008 and was followed to July 2009. Demographics, clinical and laboratory parameters, causes of death, and patient and technique survival were analyzed. ♢ RESULTS: Median age of the patients was 72 years (range: 47 - 93 years), with 60% being older than 65. The Davies score was greater than 2 in 73% of patients, and the Karnofsky index was less than 70 in 40%. The overall peritonitis rate was 1 episode in 37 patient-months. The total duration of AAPD ranged from 3 to 72 months. Patient survival was 80% at 12 months, 60% at 24 months, and 23.3% at 48 months. The most common cause of death was cardiovascular problems (70%). ♢ CONCLUSIONS: In this clinical observational study, AAPD fulfilled its expected role, offering an opportune, reliable, and effective homecare alternative for ESRD patients with no other renal replacement therapy options.


Assuntos
Serviços de Assistência Domiciliar/organização & administração , Diálise Peritoneal/métodos , Idoso , Idoso de 80 Anos ou mais , Brasil , Causas de Morte , Comorbidade , Feminino , Humanos , Falência Renal Crônica/epidemiologia , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Diálise Peritoneal/normas , Peritonite/epidemiologia , Desenvolvimento de Programas
11.
Perit Dial Int ; 33(6): 679-86, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23547280

RESUMO

OBJECTIVE: We set out to estimate the direct medical costs (DMCs) of peritoneal dialysis (PD) and to compare the DMCs for continuous ambulatory PD (CAPD) and automated PD (APD). In addition, DMCs according to age, sex, and the presence of peritonitis were evaluated. METHODS: Our retrospective cohort analysis considered patients initiating PD, calculating 2008 costs and, for comparison, updating the results for 2010. The analysis took the perspective of the Mexican Institute of Social Security, including outpatient clinic and emergency room visits, dialysis procedures, medications, laboratory tests, hospitalizations, and surgeries. RESULTS: No baseline differences were observed for the 41 patients evaluated (22 on CAPD, 19 on APD). Median annual DMCs per patient on PD were US$15 072 in 2008 and US$16 452 in 2010. When analyzing percentage distribution, no differences were found in the DMCs for the modality groups. In both APD and CAPD, the main costs pertained to the dialysis procedure (CAPD 41%, APD 47%) and hospitalizations (CAPD 37%, APD 32%). Dialysis procedures cost significantly more (p = 0.001) in APD (US$7 084) than in CAPD (US$6 071), but total costs (APD US$15 389 vs CAPD US$14 798) and other resources were not different. The presence of peritonitis increased the total costs (US$16 075 vs US$14 705 for patients without peritonitis, p = 0.05), but in the generalized linear model analysis, DMCs were not predicted by age, sex, dialysis modality, or peritonitis. A similar picture was observed for costs extrapolated to 2010, with a 10% - 20% increase for each component--except for laboratory tests, which increased 52%, and dialysis procedures, which decreased 3%, from 2008. CONCLUSIONS: The annual DMCs per patient on PD in this study were US$15 072 in 2008 and US$16 452 in 2010. Total DMCs for dialysis procedures were higher in APD than in CAPD, but the difference was not statistically significant. In both APD and CAPD, 90% of costs were attributable to the dialysis procedure, hospitalizations, and medications. In a multivariate analysis, no independent variable significantly predicted a higher DMC.


Assuntos
Diálise Peritoneal Ambulatorial Contínua/economia , Diálise Peritoneal/economia , Adulto , Idoso , Feminino , Humanos , Modelos Lineares , Masculino , México , Pessoa de Meia-Idade , Análise Multivariada , Peritonite/economia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA