RESUMO
Objective: to analyze the stress distribution in a 3D model that simulates second molar mesialization using two different types of mini-implants. Material and Methods: a mandible bone model was obtained by recomposing a computed tomography performed by a software program. The cortical and trabecular bone, a lower second molar, periodontal ligament, orthodontic tube, resin cement and the mini-implants were designed and modeled using the Rhinoceros 4.0 software program. The characteristics of self-drilling orthodontic mini-implants were: one with 7 mm length, 1 mm transmucosal neck section and 1.6 mm diameter and another with 5 mm length and 1.5 mm diameter. A total of 235.161 and 224.505 elements were used for the mesh. These models were inserted into the bone block and then subjected to loads of 200 cN (centinewton). The results were calculated and analyzed by the Ansys 17.0 software program for qualitative verification through displacement and maximum principal stress maps. Results: it was possible to observe that the periodontal ligament presented low displacement and stress values. However, the physiological values presented are among those capable to provide orthodontic movement, with compression and tensile area visualization staggered between 0.1 and -0.1 MPa (megapascal). Conclusion: within the limitations of the study, the mini-implants tested showed similar results where the load on the tooth allowed dental displacement (molar mesialization), with a tendency to rotate it, theoretically allowing the second molar to take the location of the first molar. (AU)
Objetivo: analisar a distribuição de tensões em um modelo 3D que simula a mesialização do segundo molar usando dois tipos diferentes de mini-implantes. Material e Métodos: um modelo de osso mandibular foi obtido por recomposição de uma tomografia computadorizada realizada por um software. O osso cortical e trabecular, um segundo molar inferior, ligamento periodontal, tubo ortodôntico, cimento resinoso e os mini-implantes foram projetados e modelados no software Rhinoceros 4.0. As características dos mini-implantes ortodônticos auto perfurantes foram: um com 7 mm de comprimento, 1 mm de secção transmucosa e 1,6 mm de diâmetro e outro com 5 mm de comprimento e 1,5 mm de diâmetro. Para a malha, foram utilizados 235.161 e 224.505 elementos. Esses modelos foram inseridos no bloco ósseo e então submetidos a cargas de 200 cN (centinewton). Os resultados foram calculados e analisados pelo software Ansys 17.0 para verificação qualitativa por meio de mapas de deslocamento e tensões máximas principais. Resultados: foi possível observar que o ligamento periodontal apresentou baixos valores de deslocamento e tensões. Porém, os valores fisiológicos apresentados são capazes de proporcionar movimentação ortodôntica, com visualização da área de compressão e tração escalonada entre 0,1 e -0,1 MPa (megapascal). Conclusão: dentro das limitações do estudo, os mini-implantes testados apresentaram resultados semelhantes onde a carga sobre o dente permitiu o deslocamento dentário (mesialização do molar), com tendência a girá-lo, permitindo teoricamente que o segundo molar ocupe do lugar do primeiro molar (AU)
Assuntos
Avulsão Dentária , Implantes Dentários , Análise de Elementos Finitos , Procedimentos de Ancoragem Ortodôntica , Aparelhos Ortodônticos FixosRESUMO
This case report outlines a rare complete intrusion of a permanent, maxillary central incisor (tooth 11) into the nasal cavity, with a late diagnosis and treatment. An eight-year-old boy was referred to an oral and maxillofacial surgery service with absence of tooth 11 after an episode of a fall from his own height. Approximately 50 days after the trauma, the patient presented with a complaint of obstruction of the right nostril. The clinical examination and tomographic evaluation showed that the tooth had been intruded into the nasal cavity on the right side. The tooth in question was removed under general anesthesia by direct approach through the right nostril. The patient was followed up for approximately one year without complications. This case demonstrates the importance of a detailed evaluation during the first examination after intrusive luxation, so the correct diagnosis is made and the correct treatment is performed to avoid greater morbidity and complications for the patient.
Assuntos
Incisivo , Avulsão Dentária , Criança , Dente Canino , Dentição Permanente , Humanos , Incisivo/diagnóstico por imagem , Incisivo/lesões , Masculino , Cavidade Nasal/diagnóstico por imagem , Avulsão Dentária/complicações , Avulsão Dentária/terapiaRESUMO
O trauma dentoalveolar tem uma incidência significativa entre os traumas faciais e a complexidade do tratamento depende do tipo de fratura e do grau de desenvolvimento do dente. Os traumas dentários, principalmente aqueles que envolvem os dentes anteriores, influemciam a função e a estética do indivíduo, afetando seu comportamento. Um traumatismo dental deve ser sempre considerado uma urgência e tratado de forma imediata para aliviar a dor, facilitar a redução dos dentes deslocados e melhorar o prognóstico. Assim sendo, esse relato de caso propôe uma sequência clínica de atendimento/reabilitação de uma paciete jovem acometida por traumatismo facial com comprometimento diverso de estruturas dentárias e de tecidos moles.
The dentoalveolar trauma has a significant effect between facial trauma and complexity of treatment depends on the type of fracture and the degree of development of the tooth. The dental trauma, especially those involving the anterior teeth, influence the function and aesthetics of the individual, affecting their behavior. A dental injury should always be considered an emergency and treated immediately in order to relieve pain, facilitate reduction of displaced teeth and improve the prognosis. Therefore, this case report suggests a sequence of clinical care / rehabilitation of a young patient affected by facial trauma with involvement of different dental structures and soft tissues.