Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
São Paulo; s.n; s.n; 2022. 70 p. tab, graf.
Tese em Inglês | LILACS | ID: biblio-1392313

RESUMO

The purpose of this work was to elaborate a diagnosis of the dissolution test in Africa in comparison with Brazil, evaluating the dissolution profile of low solubility drugs such as albendazole, ibuprofen, furosemide, glibenclamide, hydrochlorothiazide and carvedilol to ascertain their quality. The dissolution profiles were evaluated by utilizing the United States Pharmacopeia (USP). The glibenclamide medicine was evaluated according to the Food and Drug Administration (FDA), while a dissolution method was developed for the carvedilol medicine. A filter selection test for all the drugs showed that cannula is suitable for all, except for carvedilol, which is centrifuged. The various brands of Nigerian and Brazilian medicines tested showed some statistical differences. The suitable conditions that allowed the dissolution of carvedilol to be determined were the USP type II apparatus at 75 rpm containing 900 mL of acetate buffer, pH 4.5. The results of the dissolution test showed that out of the 17 different brands of Brazilian medicines and 17 different products from Nigeria, 94.12% and 58.82% passed respectively


O objetivo deste trabalho foi elaborar um diagnóstico do teste de dissolução na África em comparação ao Brasil, avaliando o perfil de dissolução de medicamentos de baixa solubilidade como albendazol, ibuprofeno, furosemida, glibenclamida, hidroclorotiazida e carvedilol para verificar sua qualidade.Os perfis de dissolução foram avaliados utilizando a Farmacopeia dos Estados Unidos (USP). O medicamento glibenclamida foi avaliado de acordo com a Food and Drug Administration (FDA), enquanto um método de dissolução foi desenvolvido para o medicamento carvedilol.Um teste de seleção de filtro para todos os medicamentos mostrou que a cânula é adequada para todos, exceto para o carvedilol, que é centrifugado. As diversas marcas de medicamentos Nigerianos e Brasileiros testadas apresentaram algumas diferenças estatísticas. As condições adequadas que permitiram a determinação da dissolução do carvedilol foram o aparelho USP tipo II a 75 rpm contendo 900 mL de tampão acetato, pH 4,5. Os resultados do teste de dissolução mostraram que das 17 diferentes marcas de medicamentos brasileiros e 17 diferentes produtos da Nigéria, 94,12% e 58,82% foram aprovados, respectivamente


Assuntos
Solubilidade , Brasil/etnologia , Preparações Farmacêuticas/análise , África/etnologia , Dissolução , United States Food and Drug Administration , Albendazol/farmacologia , Ibuprofeno , Carvedilol/farmacologia , Furosemida/farmacologia , Métodos , Acetatos/efeitos adversos
2.
Biosci. j. (Online) ; 33(5): 1351-1361, sept./oct. 2017. graf, tab
Artigo em Inglês | LILACS | ID: biblio-966384

RESUMO

Secnidazole, a 5-nitroimidazole, is a drug used in the treatment against protozoa, and several bacterial infections. This study purpose was to develop and validate a UV spectrophotometric method to determine secnidazole in pharmaceutical tablet dosage forms once there is no method reported in the pharmacopoeia yet. The quantification was performed using methanol as solvent at 325 nm (maximum wavelength) and three kinds of products marketed in Brazil (reference, generic and similar tablets) containing 1g of secnidazole. The method obeyed Beer's law in the concentration range of 4 - 20 µgmL-1 respectively. The method was validated according to the International Conference on Harmonization (ICH) and Brazil National Health Surveillance Agency (ANVISA) guidelines, showing accuracy, precision, selectivity, robustness and linearity. Tests such as weight range, friability, disintegration, hardness and dissolution were carried out to check tablets' quality and all the trials showed to be in accordance with the general test guidelines of the Brazilian Pharmacopoeia. The dissolution test was carried out and the developed method was applied. The method developed is suitable for the estimation of secnidazole in tablets without any interference from the excipients and can be used for routine in quality control. Still, it's a simple, fast and low cost method.


Secnidazol, um nitroimidazólico, é um fármaco utilizado no tratamento para protozoários, e várias infecções bacterianas. Este trabalho propôs o desenvolvimento e validação de um método espectrofotométrico na região do ultravioleta para a determinação de Secnidazol na forma farmacêutica de comprimidos, uma vez que não há nenhum método relatado nas farmacopeias. A quantificação foi realizada utilizando metanol como solvente a 325 nm (máximo de comprimento de onda) e usando três tipos de produtos comercializados no Brasil (de referência, genéricos e comprimidos similares) contendo 1g de Secnidazol. O método obedeceu a lei de Beer no intervalo de concentração de 4 - 20 µgmL-1, respectivamente. O método foi validado de acordo com a Conferência Internacional de Harmonização (ICH) e diretrizes da Agência Nacional de Vigilância Sanitária do Brasil (ANVISA), apresentando exatidão, precisão, seletividade, robustez e linearidade. Testes como variação de peso, friabilidade, desintegração, dureza e dissolução foram realizados para verificar a qualidade de comprimidos e mostrou-se de acordo com os testes gerais da Farmacopeia Brasileira. O teste de dissolução realizado e o método desenvolvido pode ser aplicado. O método desenvolvido é adequado para a estimativa de secnidazole em comprimidos sem qualquer interferência dos excipientes e pode ser usado para a rotina de controlo de qualidade. Ainda, é um método simples, rápido e de baixo custo.


Assuntos
Controle de Qualidade , Infecções Bacterianas , Anti-Infecciosos , Antibacterianos , Nitroimidazóis
3.
Braz. j. pharm. sci ; 50(1): 83-89, Jan-Mar/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-709549

RESUMO

Ranitidine is an antisecretory drug with H2 antagonist action useful in treating gastric and duodenal disorders. The dissolution test is used to obtain and compare dissolution profiles and establish similarities of pharmaceutical forms. The aim of this study was to compare the dissolution profiles of 150-mg coated ranitidine tablets of a reference drug (product A) and a generic (product B) and a similar (product C) drug marketed in Bahia, Brazil using a simple, fast and inexpensive ultraviolet method. Dissolution was determined using a USP type 2 apparatus at 50 rpm with 900 mL of distilled water at 37.0 ± 0.5 oC for 1h. The dissolution test was performed in compliance with the American Pharmacopoeia (USP-32). Dissolution efficiency and difference (f1) and similarity (f2) factors were calculated and evaluated. The proposed quantification methodology for drug dissolution test was validated, presenting accuracy, linearity and precision within the acceptance criteria. Products A, B and C showed dissolution efficiency values of 59.29, 73.59 and 66.67%, respectively. Factors f1 and f2 were calculated and showed that the profiles of products A, B and C were dissimilar. However, all the products released ranitidine satisfactorily, with at least 80% of the drug dissolved within 30 min.


A ranitidina é um fármaco antissecretor, antagonista H2, usado no tratamento de desordens gástricas e duodenais. O teste de dissolução é utilizado para obter e comparar perfis de dissolução, estabelecendo semelhança de formas farmacêuticas. Este estudo tem por objetivo comparar perfis de dissolução de comprimidos revestidos contendo 150 mg de ranitidina, em medicamentos de referência (produto A), genérico (produto B) e similar (produto C) comercializados na Bahia-Brasil, usando um método ultravioleta simples, rápido e de baixo custo. As condições que permitiram a determinação da dissolução foram: aparelho USP tipo 2 a 50 rpm, contendo 900 mL de água destilada mantida a 37,0 ± 0,5 °C, durante 1 h. O teste de dissolução foi realizado em conformidade com a Farmacopeia Americana (USP-32). Cálculo da eficiência de dissolução e fatores de diferença (f1) e semelhança (f2) foram avaliados. A metodologia proposta para a quantificação do fármaco no ensaio de dissolução foi validada apresentando precisão, linearidade e exatidão dentro dos critérios de aceitação. Os produtos A, B e C mostraram eficiência de dissolução de 59,29, 73,59 e 66,67%, respectivamente. Calcularam-se os fatores f1 e f2 e mostrou-se que os perfis não foram semelhantes para os comprimidos de produtos A, B e C. No entanto, todos os produtos liberaram o fármaco satisfatoriamente, pois, pelo menos, 80% de ranitidina foram dissolvidos em 30 min.


Assuntos
Ranitidina/farmacocinética , Comprimidos com Revestimento Entérico/farmacocinética , Espectrofotometria Ultravioleta/métodos , Comprimidos/farmacocinética , Brasil , Dissolução/análise
4.
Braz. j. pharm. sci ; 50(2): 329-336, Apr-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-722177

RESUMO

The dissolution process is considered an important in vitro tool to evaluate product quality and drug release behavior. Single dissolution methods for the analysis of combined dosage forms are preferred to simplify quality control testing. The objective of the present work was to develop and validate a single dissolution test for a telmisartan (TEL) and amlodipine besylate (AML) combined tablet dosage form. The sink conditions, stability and specificity of both drugs in different dissolution media were tested to choose a discriminatory dissolution method, which uses an USP type-II apparatus with a paddle rotating at 75 rpm, with 900 mL of simulated gastric fluid (SGF without enzymes) as the dissolution medium. This dissolution methodology provided good dissolution profiles for both TEL and AML and was able to discriminate changes in the composition and manufacturing process. To quantify both drugs simultaneously, a synchronous first derivative spectrofluorimetric method was developed and validated. Drug release was analyzed by a fluorimetric method at 458 nm and 675 nm for AML and TEL, respectively. The dissolution method was validated as per ICH guidance.


O processo de dissolução é considerado como uma importante ferramenta in vitro para avaliar a qualidade do produto e o comportamento de liberação do fármaco. Prefere-se um ensaio único de dissolução para formas farmacêuticas contendo associação de fármacos pela simplificação dos testes de controle de qualidade. O objetivo do presente trabalho foi desenvolver e validar um teste de dissolução único para forma farmacêutica comprimidos contendo telmisartana (TEL) e besilato de anlodipino (AML) associados. Condições "sink", estabilidade e especificidade de ambos os fármacos nos diferentes meios de dissolução foram avaliadas para selecionar um método de dissolução discriminatório, que utiliza um aparato do tipo II da USP, com pás girando a 75 rpm e 900 mL de fluido gástrico simulado (SGF sem enzima) como o meio de dissolução. Estas condições proporcionaram bons perfis de dissolução para ambos, TEL e AML, sendo capaz de discriminar as mudanças na composição e processo de fabricação. Para quantificar os dois fármacos simultaneamente, um método de fluorescência derivada sincronizado foi desenvolvido e validado. A quantidade de fármaco liberado foi analisada pelo método fluorimétrico em 458 e 675 nm para a AML e TEL, respectivamente. O método de dissolução foi validado de acordo com a orientação da ICH.


Assuntos
Espectrometria de Fluorescência/métodos , Anti-Hipertensivos , Controle de Qualidade , Formas de Dosagem , Dissolução/classificação
5.
Braz. j. pharm. sci ; 46(2): 179-186, Apr.-June 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-564883

RESUMO

A dissolution test for tablets containing 100 mg of lamotrigine was developed and validated. The dissolution test was applied to compare the dissolution profile of Neural® with the reference product Lamictal®. The analysis procedure was carried out using a simple ultraviolet method at 267 nm. After the determination of solubility and sink conditions, the parameters selected were paddles at 50 rpm, 900 mL of 0.01 M hydrochloric acid, and 30 minutes duration (single point). This method was validated for specificity, linearity, accuracy, precision and robustness. Lamotrigine stability was also evaluated in dissolution medium.


A finalidade deste estudo foi desenvolver e validar um método de dissolução para o fármaco lamotrigina na forma farmacêutica comprimido. Este método também foi utilizado para comparar o perfil de dissolução entre o Neural® e o produto de referência Lamictal®. O procedimento analítico foi realizado utilizando-se espectrofotometria de absorção no ultravioleta (267 nm) como forma de quantificação do fármaco. Após a determinação da solubilidade e das condições sink, os parâmetros selecionados foram: pás (50 rpm), 900 mL de ácido clorídrico 0.01 M e o tempo de 30 minutos (único ponto). Este método foi validado através da especificidade, linearidade, exatidão, precisão e robustez. A estabilidade da lamotrigina também foi avaliada no meio de dissolução.


Assuntos
Anticonvulsivantes/análise , Comprimidos/química , Desenvolvimento Tecnológico/análise , Dissolução/métodos , Espectrofotometria Ultravioleta/métodos , Preparações Farmacêuticas , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA