Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Vive (El Alto) ; 6(18): 948-960, dic. 2023.
Artigo em Espanhol | LILACS | ID: biblio-1530585

RESUMO

La medicina nuclear utiliza radiofármacos, conocidos como radiotrazadores, para evaluar la función y el metabolismo de órganos y sistemas del cuerpo. Objetivo. Examinar la relevancia de los radiotrazadores MDP, DTPA y MIBI, marcados con tecnecio-99m (Tc99m), en el diagnóstico en medicina nuclear. Metodología. Se siguió el método PRISMA para identificar estudios publicados entre 2010 y 2022. Las bases de datos consultadas incluyeron Dialnet, Elsevier, Research, Redalyc, PubMed, Google Académico y Scielo. Se utilizaron descriptores específicos como "radiotrazadores Tc99m", "MDP", "DTPA", "MIBI", y "medicina nuclear", centrando la búsqueda en diagnóstico y excluyendo propósitos terapéuticos. Resultados. De 14 estudios analizados, se observó una predominancia en investigaciones sobre radiotrazadores MDP y MIBI marcados con Tc99m, enfocándose en diagnósticos relacionados con lesiones paratiroideas, hiperparatiroidismo, enfermedades esqueléticas, enfermedad arterial coronaria y perfusión miocárdica. Conclusiones. Los radiotrazadores MDP, DTPA y MIBI marcados con Tc99m demuestran eficacia en diversas aplicaciones diagnósticas, incluyendo la localización de adenomas paratiroideos y la detección de condiciones como el mieloma múltiple. A pesar de sus beneficios, es crucial continuar investigando y desarrollando nuevos radiofármacos para expandir su utilidad clínica y mejorar aún más la atención médica en el campo de la medicina nuclear.


Nuclear medicine uses radiopharmaceuticals, known as radiotracers, to assess the function and metabolism of organs and body systems. Objective. To examine the relevance of technetium-99m (Tc99m)-labeled MDP, DTPA, and MIBI radiotracers in nuclear medicine diagnostics. Methodology. The PRISMA method was followed to identify studies published between 2010 and 2022. The databases consulted included Dialnet, Elsevier, Research, Redalyc, PubMed, Google Scholar and Scielo. Specific descriptors such as "Tc99m radiotracers", "MDP", "DTPA", "MIBI", and "nuclear medicine" were used, focusing the search on diagnosis and excluding therapeutic purposes. Results. Of 14 studies analyzed, there was a predominance of research on Tc99m-labeled MDP and MIBI radiotracers, focusing on diagnoses related to parathyroid lesions, hyperparathyroidism, skeletal diseases, coronary artery disease, and myocardial perfusion. Conclusions. Tc99m-labeled MDP, DTPA, and MIBI radiotracers demonstrate efficacy in a variety of diagnostic applications, including localization of parathyroid adenomas and detection of conditions such as multiple myeloma. Despite their benefits, it is crucial to continue researching and developing new radiopharmaceuticals to expand their clinical utility and further improve medical care in the field of nuclear medicine.


A medicina nuclear utiliza radiofármacos, conhecidos como radiotraçadores, para avaliar a função e o metabolismo de órgãos e sistemas corporais. Objetivo. Examinar a importância dos radiotraçadores MDP, DTPA e MIBI, marcados com tecnécio-99m (Tc99m), em diagnósticos de medicina nuclear. Metodologia. O método PRISMA foi usado para identificar estudos publicados entre 2010 e 2022. Os bancos de dados consultados incluíram Dialnet, Elsevier, Research, Redalyc, PubMed, Google Scholar e Scielo. Foram utilizados descritores específicos como "radiotraçadores Tc99m", "MDP", "DTPA", "MIBI" e "medicina nuclear", concentrando a busca em fins diagnósticos e excluindo fins terapêuticos. Resultados. Dos 14 estudos analisados, houve predomínio de pesquisas com os radiotraçadores MDP e MIBI marcados com Tc99m, com foco em diagnósticos relacionados a lesões da paratireoide, hiperparatireoidismo, doenças esqueléticas, doença arterial coronariana e perfusão miocárdica. Conclusões. Os radiotraçadores MDP, DTPA e MIBI marcados com Tc99m demonstram eficácia em uma variedade de aplicações diagnósticas, incluindo a localização de adenomas de paratireoide e a detecção de doenças como o mieloma múltiplo. Apesar de seus benefícios, é fundamental continuar a pesquisa e o desenvolvimento de novos radiofármacos para expandir sua utilidade clínica e melhorar ainda mais o atendimento médico no campo da medicina nuclear.

2.
Braz. j. otorhinolaryngol. (Impr.) ; Braz. j. otorhinolaryngol. (Impr.);88(5): 740-744, Sept.-Oct. 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403929

RESUMO

Abstract Introduction Surgical treatment of hyperparathyroidism related to chronic kidney disease is a real challenge for Brazilian public health care. High cost medications and long waiting lines to perform preoperative exams, especially technetium Tc 99m Sestamibi (MIBI) are some of the reasons. Despite the reality that the aid of localization exams are questionable in this scenario, doctors are too apprehensive in performing surgery without it. Objective The study aimed at evaluating the efficacy of surgery for renal hyperparathyroidism without preoperative MIBI. Methods A total of 114 patients were surgically treated. Total parathyroidectomy with autotransplantation and subtotal parathyroidectomy were carried out without preoperative MIBI. Results and conclusion Among the 114 patients undergoing surgery, 37 had secondary hyperparathyroidism in dialysis replacement, and 77 patients had post-renal transplant persistent disease. We were successful in 107 cases with only 7 failures (93.8% of success rate). Among these failures, only one parathyroid gland was not found in 4 cases, 2 parathyroid glands were not found in 2 cases and in 1 patient the 4 glands were found but this patient remained hypercalcemic and a postoperative diagnosis of supernumerary parathyroid gland was made. Surgery for treatment of renal hyperparathyroidism proved to be an effective (93.8%) and reproductible procedure, even without MIBI.


Resumo Introdução O tratamento cirúrgico do hiperparatireoidismo relacionado à doença renal crônica é um verdadeiro desafio para a saúde pública brasileira. Medicamentos de alto custo e longas filas de espera para exames pré‐operatórios, principalmente a cintilografia com tecnécio Tc‐99m Sestamibi, MIBI, são alguns dos motivos. Apesar da contribuição de exames de localização ser questionável nesse cenário, os médicos ficam muito apreensivos por fazer uma cirurgia sem ele. Objetivo Avaliar a eficácia da cirurgia para hiperparatireoidismo renal sem o MIBI pré‐operatório. Método Foram tratados cirurgicamente 114 pacientes. A paratireoidectomia total com autotransplante e a paratireoidectomia subtotal foram feitas sem MIBI pré‐operatório. Resultados e conclusão Entre os 114 pacientes submetidos à cirurgia, 37 apresentavam hiperparatireoidismo secundário em reposição dialítica e 77 doença persistente pós‐transplante renal. Tivemos sucesso em 107 casos, com apenas 7 falhas (93,8% de taxa de sucesso). Entre essas falhas, uma glândula paratireoide não foi encontrada em 4 casos, 2 glândulas paratireoides não foram encontradas em 2 casos e em um paciente as 4 glândulas foram encontradas, mas ele permaneceu hipercalcêmico com diagnóstico pós‐operatório de glândula paratireoide supranumerária. A cirurgia para tratamento do hiperparatireoidismo renal mostrou‐se um procedimento eficaz (93,8%) e reprodutível mesmo sem MIBI.

3.
Braz J Otorhinolaryngol ; 88(5): 740-744, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33303418

RESUMO

INTRODUCTION: Surgical treatment of hyperparathyroidism related to chronic kidney disease is a real challenge for Brazilian public health care. High cost medications and long waiting lines to perform preoperative exams, especially technetium Tc 99m Sestamibi (MIBI) are some of the reasons. Despite the reality that the aid of localization exams are questionable in this scenario, doctors are too apprehensive in performing surgery without it. OBJECTIVE: The study aimed at evaluating the efficacy of surgery for renal hyperparathyroidism without preoperative MIBI. METHODS: A total of 114 patients were surgically treated. Total parathyroidectomy with autotransplantation and subtotal parathyroidectomy were carried out without preoperative MIBI. RESULTS AND CONCLUSION: Among the 114 patients undergoing surgery, 37 had secondary hyperparathyroidism in dialysis replacement, and 77 patients had post-renal transplant persistent disease. We were successful in 107 cases with only 7 failures (93.8% of success rate). Among these failures, only one parathyroid gland was not found in 4 cases, 2 parathyroid glands were not found in 2 cases and in 1 patient the 4 glands were found but this patient remained hypercalcemic and a postoperative diagnosis of supernumerary parathyroid gland was made. Surgery for treatment of renal hyperparathyroidism proved to be an effective (93.8%) and reproductible procedure, even without MIBI.


Assuntos
Hiperparatireoidismo Secundário , Paratireoidectomia , Humanos , Hiperparatireoidismo Secundário/diagnóstico por imagem , Hiperparatireoidismo Secundário/cirurgia , Glândulas Paratireoides/cirurgia , Paratireoidectomia/métodos , Cuidados Pré-Operatórios/métodos , Cintilografia , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi
4.
Radiol Bras ; 52(2): 92-96, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31019337

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effects of electrical muscle stimulation (EMS) on muscles, using 99mTc-sestamibi SPECT/CT. MATERIALS AND METHODS: We prospectively enrolled 20 consecutive male professional water polo players. The mean age was 25 years (range, 18-36 years). All athletes underwent 99mTc-sestamibi SPECT/CT of the thigh (rectus femoris and vastus medialis muscle groups) before and after EMS. Images were quantified to identify increases in perfusion after EMS. RESULTS: Before EMS, there were no significant differences between the right and left thigh (rectus femoris and vastus medialis muscles) in terms of perfusion (p = 0.4). However, the comparison between the pre- and post-EMS analyses of the same muscle groups showed significant differences in radiotracer uptake (p < 0.001), with a mean increase in perfusion of 128% for the rectus femoris muscle group (95% CI: 0.86-1.61) and 118% for the vastus medialis muscle group (95% CI: 0.96-1.79). CONCLUSION: 99mTc-sestamibi SPECT/CT is an objective means of evaluating blood flow in muscles submitted to EMS, which appears to promote significant increases in such blood flow.


OBJETIVO: O objetivo deste estudo foi avaliar o efeito da estimulação elétrica transcutânea na musculatura esquelética utilizando-se SPECT/CT com 99mTc- sestamibi. MATERIAIS E MÉTODOS: Foram prospectivamente avaliados 20 atletas masculinos de polo aquático (18-36 anos de idade; média de 25 anos). Todos os atletas foram submetidos a SPECT/CT com 99mTc- sestamibi das coxas antes e após estimulação elétrica transcutânea dos grupos musculares reto femoral e vasto medial. As imagens foram quantificadas para identificar aumento da perfusão. RESULTADOS: A comparação da perfusão dos grupos musculares (reto femoral e vasto medial) direito versus esquerdo durante o repouso não demonstrou diferença significativa (p = 0,4). Entretanto, quando comparados esses mesmos grupos musculares antes e após a estimulação elétrica, observou-se diferença significativa na captação do traçador (p < 0,001), com aumento perfusional médio de 128% do grupo reto femoral (IC 95%: 0,86-1,61) e 118% do grupo vasto medial (IC 95%: 0,96-1,79) no grupo estimulado. CONCLUSÃO: A SPECT/CT com 99mTc- sestamibi é capaz de demonstrar de forma objetiva que a estimulação elétrica transcutânea aumenta significativamente o fluxo sanguíneo muscular.

5.
Radiol. bras ; Radiol. bras;52(2): 92-96, Mar.-Apr. 2019. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1002983

RESUMO

Abstract Objective: The purpose of this study was to evaluate the effects of electrical muscle stimulation (EMS) on muscles, using 99mTc-sestamibi SPECT/CT. Materials and Methods: We prospectively enrolled 20 consecutive male professional water polo players. The mean age was 25 years (range, 18-36 years). All athletes underwent 99mTc-sestamibi SPECT/CT of the thigh (rectus femoris and vastus medialis muscle groups) before and after EMS. Images were quantified to identify increases in perfusion after EMS. Results: Before EMS, there were no significant differences between the right and left thigh (rectus femoris and vastus medialis muscles) in terms of perfusion (p = 0.4). However, the comparison between the pre- and post-EMS analyses of the same muscle groups showed significant differences in radiotracer uptake (p < 0.001), with a mean increase in perfusion of 128% for the rectus femoris muscle group (95% CI: 0.86-1.61) and 118% for the vastus medialis muscle group (95% CI: 0.96-1.79). Conclusion: 99mTc-sestamibi SPECT/CT is an objective means of evaluating blood flow in muscles submitted to EMS, which appears to promote significant increases in such blood flow.


Resumo Objetivo: O objetivo deste estudo foi avaliar o efeito da estimulação elétrica transcutânea na musculatura esquelética utilizando-se SPECT/CT com 99mTc- sestamibi. Materiais e Métodos: Foram prospectivamente avaliados 20 atletas masculinos de polo aquático (18-36 anos de idade; média de 25 anos). Todos os atletas foram submetidos a SPECT/CT com 99mTc- sestamibi das coxas antes e após estimulação elétrica transcutânea dos grupos musculares reto femoral e vasto medial. As imagens foram quantificadas para identificar aumento da perfusão. Resultados: A comparação da perfusão dos grupos musculares (reto femoral e vasto medial) direito versus esquerdo durante o repouso não demonstrou diferença significativa (p = 0,4). Entretanto, quando comparados esses mesmos grupos musculares antes e após a estimulação elétrica, observou-se diferença significativa na captação do traçador (p < 0,001), com aumento perfusional médio de 128% do grupo reto femoral (IC 95%: 0,86-1,61) e 118% do grupo vasto medial (IC 95%: 0,96-1,79) no grupo estimulado. Conclusão: A SPECT/CT com 99mTc- sestamibi é capaz de demonstrar de forma objetiva que a estimulação elétrica transcutânea aumenta significativamente o fluxo sanguíneo muscular.

6.
Rev. méd. Chile ; 145(8): 1021-1027, ago. 2017. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-902580

RESUMO

Background: 99mTc-sestamibi parathyroid SPECT scintigraphy is a useful tool in the pre-operative study of hyperparathyroidism. False negatives (FN) have been reported in 5.7-14% of the examinations. Aim: To characterize 99mTc-sestamibi FN in cases referred for primary hyperparathyroidism (PHP) to a university hospital. Material and Methods: Descriptive retrospective analysis. We included patients with PHP, studied with SPECT scintigraphy, operated at our center between 2008 and 2015. Clinical and surgical data were recorded; biopsies of the FN were blindly reviewed by one pathologist. Results: One hundred twenty one scintigraphies fulfilled the inclusion criteria. Seven (5.8%) were negative and 114 positive. There was no difference in age, sex and PTH levels between FN and true positive scintigraphies. At surgery, one FN case had two hyperplasic glands and two cases had ectopic glands. Pathology reported adenoma in three cases, hyperplasia in three and carcinoma in one. The largest diameter of the lesion was lower in FN (1.3 and 2.1 cm respectively, p = 0.02) and the proportion of adenomas was higher in true positive cases (29% and 75% respectively; p < 0.01). The interval between scintigraphy and parathyroidectomy was greater in FN with a median of 92 days (range 20 days-3.2 years, p < 0.01). The percentage of oxyphilic cells observed was similar in both groups. Conclusions: FN parathyroid SPECT scintigraphies in PHP are uncommon. They corresponded to lesions under the equipment's resolution limit and resulted in longer time lags between scintigraphy and surgery.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Glândulas Paratireoides/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tecnécio Tc 99m Sestamibi , Compostos Radiofarmacêuticos , Hiperparatireoidismo Primário/diagnóstico por imagem , Neoplasias das Paratireoides/patologia , Neoplasias das Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/patologia , Padrões de Referência , Valores de Referência , Carcinoma/patologia , Carcinoma/diagnóstico por imagem , Adenoma/patologia , Adenoma/diagnóstico por imagem , Estudos Retrospectivos , Estatísticas não Paramétricas , Hiperparatireoidismo Primário/patologia , Reações Falso-Negativas , Hiperplasia/patologia , Hiperplasia/diagnóstico por imagem
8.
Rev. méd. Chile ; 143(11): 1426-1434, nov. 2015. ilus, graf, tab
Artigo em Espanhol | LILACS | ID: lil-771732

RESUMO

Background: The evaluation of coronary artery disease (CAD) can be performed with stress test and myocardial SPECT tomography. Aim: To assess the predictive value of myocardial SPECT using stress test for cardiovascular events in patients with good exercise capacity. Material and Methods: We included 102 males aged 56 ± 10 years and 19 females aged 52 ± 10 years, all able to achieve 10 METs and ≥ 85% of the theoretical maximum heart rate and at least 8 min in their stress test with gated 99mTc-sestamibi SPECT. Eighty two percent of patients were followed clinically for 33 ± 17 months. Results: Sixty seven percent of patients were studied for CAD screening and the rest for known disease assessment. Treadmill stress test was negative in 75.4%; 37% of patients with moderate to severe Duke Score presented ischemia. Normal myocardial perfusion SPECT was observed in 70.2%. Reversible defects appeared in 24.8% of cases, which were of moderate or severe degree (> 10% left ventricular extension) in 56.6%. Only seven cases had coronary events after the SPECT. Two major (myocardial infarction and emergency coronary revascularization) and 5 minor events (elective revascularization) ere observed in the follow-up. In a multivariate analysis, SPECT ischemia was the only statistically significant parameter that increased the probability of having a major or minor event. Conclusions: Nearly a quarter of our patients with good exercise capacity demonstrated reversible defects in their myocardial perfusion SPECT. In the intermediate-term follow-up, a low rate of cardiac events was observed, being the isotopic ischemia the only significant predictive parameter.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença da Artéria Coronariana , Teste de Esforço/métodos , Tolerância ao Exercício , Tomografia Computadorizada de Emissão de Fóton Único , Doença da Artéria Coronariana/mortalidade , Seguimentos , Equivalente Metabólico/fisiologia , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica , Valor Preditivo dos Testes , Prognóstico , Análise de Sobrevida
9.
Acta cir. bras ; Acta cir. bras;30(6): 388-393, 06/2015. tab
Artigo em Inglês | LILACS | ID: lil-749643

RESUMO

PURPOSE: To evaluate the heart and the Tc-99m-sestamibi biodistribution after statin pretreatment in a rat model of abdominal sepsis. METHODS: Twenty-four Wistar rats were randomly distributed into four groups (n=6 per group): 1) sepsis with simvastatin treatment, 2) sepsis with vehicle, 3) sham control with simvastatin and 4) sham control with vehicle. 24 hours after cecal ligation and puncture rats received 1.0MBq of Tc-99m-sestamibi i.v. 30min after, animals were euthanized for ex-vivo tissue counting and myocardium histological analysis. RESULTS: Myocardial histologic alterations were not detected 24 hours post-sepsis. There was significantly increased cardiac Tc-99m-sestamibi activity in the sepsis group with simvastatin treatment (1.9±0.3%ID/g, p<0.001) in comparison to the sepsis group+vehicle (1.0±0.2%ID/g), control sham group+ simvastatin (1.2±0.3%ID/g) and control sham group (1.3±0.2%ID/g). Significant Tc-99m-sestamibi activity in liver, kidney and lungs was also detected in the sepsis group treated with simvastatinin comparison to the other groups. CONCLUSIONS: Statin treatment altered the biodistribution of Tc-99m-sestamibi with increased cardiac and solid organ activity in rats with abdominal sepsis, while no impact on controls. Increased myocardial tracer activity may be a result of a possible protection effect due to increased tissue perfusion mediated by statins. .


Assuntos
Animais , Coração/efeitos dos fármacos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Infecções Intra-Abdominais/tratamento farmacológico , Sepse/tratamento farmacológico , Sinvastatina/uso terapêutico , Modelos Animais de Doenças , Coração , Infecções Intra-Abdominais/complicações , Rim/efeitos dos fármacos , Rim , Fígado/efeitos dos fármacos , Fígado , Pulmão/efeitos dos fármacos , Pulmão , Distribuição Aleatória , Ratos Wistar , Reprodutibilidade dos Testes , Compostos Radiofarmacêuticos/farmacocinética , Sepse/complicações , Fatores de Tempo , Resultado do Tratamento , /farmacocinética
10.
Acta cir. bras. ; 30(6): 388-393, June 2015. tab
Artigo em Inglês | VETINDEX | ID: vti-23104

RESUMO

PURPOSE:To evaluate the heart and the Tc-99m-sestamibi biodistribution after statin pretreatment in a rat model of abdominal sepsis.METHODS:Twenty-four Wistar rats were randomly distributed into four groups (n=6 per group): 1) sepsis with simvastatin treatment, 2) sepsis with vehicle, 3) sham control with simvastatin and 4) sham control with vehicle. 24 hours after cecal ligation and puncture rats received 1.0MBq of Tc-99m-sestamibi i.v. 30min after, animals were euthanized for ex-vivo tissue counting and myocardium histological analysis.RESULTS: Myocardial histologic alterations were not detected 24 hours post-sepsis. There was significantly increased cardiac Tc-99m-sestamibi activity in the sepsis group with simvastatin treatment (1.9±0.3%ID/g, p 0.001) in comparison to the sepsis group+vehicle (1.0±0.2%ID/g), control sham group+ simvastatin (1.2±0.3%ID/g) and control sham group (1.3±0.2%ID/g). Significant Tc-99m-sestamibi activity in liver, kidney and lungs was also detected in the sepsis group treated with simvastatinin comparison to the other groups.CONCLUSIONS:Statin treatment altered the biodistribution of Tc-99m-sestamibi with increased cardiac and solid organ activity in rats with abdominal sepsis, while no impact on controls. Increased myocardial tracer activity may be a result of a possible protection effect due to increased tissue perfusion mediated by statins.(AU)


Assuntos
Animais , Ratos , Inibidores de Hidroximetilglutaril-CoA Redutases/análise , Sepse/veterinária , Sinvastatina , Miocárdio , Tecnécio Tc 99m Sestamibi , Ratos Wistar
11.
Rev. Assoc. Med. Bras. (1992, Impr.) ; Rev. Assoc. Med. Bras. (1992, Impr.);60(4): 311-317, Jul-Aug/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-720985

RESUMO

Objective: despite the technologic advances in myocardial perfusion imaging, we keep using an uncomfortable and sometimes impracticable patient position - supine with arms raised above the head (U). The purpose of this study was to investigate whether perfusion and functional cardiac gated SPECT scan results of acquisition U are equivalent to another position modality: supine with arms down at the sides of the trunk (D). Methods and Results: we performed U acquisition and in sequence D acquisition in 120 patients (pts) using a one-day MPI (rest-gated/stress), with 99mTc-sestamibi (370 MBq and 1110 MBq). Images were processed by the iterative reconstruction method (OSEM). Rest (R) and stress (S) studies were scored using 17-segments model. Functional parameters (left ventricular ejection fraction, and volumes) were automatically obtained by the quantitative gated SPECT (QGS) program. According to the degree of stress defects observed in U study, the patients were categorized in two subgroups: normal (SSS ≤ 3 or < 5%) and abnormal (SSS>3 or ≥ 5%). Shoulder/back pain occurred in 23.3% of U patients and in 5% of D. No significant differences between U and D were found for SSS (p = 0.82) and SRS (p = 0.74) in normal group. In abnormal group, good correlation was found between U and D modes for SSS (Rho = 0.95, p = 0.0001) and SRS (Rho = 0.96 p = 0.0001), but the mean SSS (12.53 ± 7.54) and SRS (10.60 ± 7.08) values of D were significantly lower (p < 0.05) than SSS (13.43 ± 6.81) and SRS (11.33 ± 6.97) of U mode. Function measurements presented good correlations, except for end-diastolic volume (p = 0.0001). Conclusion: although D mode appears to be more comfortable and presented a good correlation with U values of SSS and SRS, in abnormal pts, the extent and severity of defects can be underestimated. Considering clinical implications of an accurate perfusion measurement, the acquisition with the ...


Objetivo: no estudo de perfusão miocárdica, apesar dos avanços tecnológicos, continuamos utilizando o desconfortável e às vezes impraticável posicionamento em decúbito dorsal com braços acima da cabeça (U). O objetivo do estudo foi investigar se os resultados da perfusão e da função cardíacas obtidos com a aquisição U são equivalentes ao de outra modalidade de posição: com braços para baixo nas laterais do tronco (D). Métodos e resultados: adquirida a aquisição U, na sequência foi realizada a aquisição D em 120 pacientes (pts) em um único dia (repouso e estresse sincronizado ao ECG), com 99mTc-sestamibi (370 MBq e 1110 MBq). As imagens foram processadas usando reconstrução iterativa (OSEM). Cada estudo foi quantificado usando o modelo de 17-segmentos ao repouso (R) e ao estresse (S). Os parâmetros funcionais (fração de ejeção do ventrículo esquerdo e volumes) foram obtidas automaticamente pelo programa gated SPECT quantitativa (QGS). De acordo com a dimensão da alteração perfusional no estresse na aquisição U, os pacientes foram classificados em dois subgrupos: 80 pts normais (SSS ≤ 3 ou < 5%) e 40 pts anormais (SSS > 3 ou ≥ 5%). Dor no ombro e/ou nas costas ocorreu em 23,3% dos pacientes de U e em 5% de D. Não houve diferenças significativas entre U e D quanto ao SSS (p = 0,82) e SRS (p = 0,74) no grupo normal. No grupo anormal, boa correlação foi encontrada entre U e D para SSS (Rho = 0,95, p = 0,0001) e SRS (Rho = 0,96 p = 0,0001), entretanto a média dos valores de SSS (12,53 ± 7,54) e SRS (10,60 ± 7,08 ) de D foram significativamente menores (p < 0,05) que o SSS (13,43 ± 6,81) e SRS (11,33 ± 6,97) de U. As medidas de função apresentaram boas correlações, ...


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Braço , Imagem de Perfusão do Miocárdio/métodos , Posicionamento do Paciente/métodos , Decúbito Dorsal , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Descanso , Volume Sistólico
12.
Acta cir. bras ; Acta cir. bras;27(6): 355-360, June 2012. ilus
Artigo em Inglês | LILACS | ID: lil-626252

RESUMO

PURPOSE: The present a novel adenocarcinoma model in athymic mice. METHODS: Seven athymic mice were used. Colon diversion and distal fistula were made. Adenocarcinoma cells were inoculated in the submucosa of fistula. Tumor growth was monitored daily. Scintigraphy with 99mTc-MIBI was performed to identify the tumor. RESULTS: The model of distal colon cancer is feasible. Tumor detection was possible by both, macroscopically and molecular imaging. All resections demonstrated poorly differentiated tumors. Colon obstruction occurred in one case, similarly to evolution in human tumors of distal colon. CONCLUSION: The proposed model of distal colon cancer is feasible, allows for easy monitoring of tumoral growth by both, macroscopically and molecular imaging, and is suitable for studying the evolution of tumor with implementation of cytotoxic therapy in vivo.


OBJETIVO: Apresentar novo modelo de adenocarcinoma distal em camundongos atímicos. MÉTODOS: Foram utilizados sete camundongos atímicos. Desvio do cólon distal e fístula foram feitas. Células de adenocarcinoma foram inoculadas na submucosa da fístula. O crescimento do tumor foi monitorado diariamente. Cintilografia com 99mTc-MIBI foi realizada para identificar o tumor. RESULTADOS: O modelo de câncer de cólon distal é viável. Detecção do tumor foi possível macroscopicamente e por imagem molecular. Todas as ressecções demonstraram tumores pouco diferenciados. Obstrução do cólon ocorreu em um caso, de forma semelhante à evolução em tumores humanos do cólon distal. CONCLUSÃO: O modelo de câncer do cólon distal proposto é viável, permite a monitorização fácil do crescimento tumoral macroscopicamente e por imagem molecular, sendo adequado para o estudo da evolução de tumor com aplicação de terapia citotóxica in vivo.


Assuntos
Animais , Camundongos , Adenocarcinoma , Neoplasias do Colo , Adenocarcinoma/patologia , Adenocarcinoma , Neoplasias do Colo/patologia , Neoplasias do Colo , Camundongos Nus , Compostos Radiofarmacêuticos , Células Tumorais Cultivadas
13.
Acta cir. bras. ; 27(6): 355-360, 2012. ilus
Artigo em Inglês | VETINDEX | ID: vti-4284

RESUMO

PURPOSE: The present a novel adenocarcinoma model in athymic mice. METHODS: Seven athymic mice were used. Colon diversion and distal fistula were made. Adenocarcinoma cells were inoculated in the submucosa of fistula. Tumor growth was monitored daily. Scintigraphy with 99mTc-MIBI was performed to identify the tumor. RESULTS: The model of distal colon cancer is feasible. Tumor detection was possible by both, macroscopically and molecular imaging. All resections demonstrated poorly differentiated tumors. Colon obstruction occurred in one case, similarly to evolution in human tumors of distal colon. CONCLUSION: The proposed model of distal colon cancer is feasible, allows for easy monitoring of tumoral growth by both, macroscopically and molecular imaging, and is suitable for studying the evolution of tumor with implementation of cytotoxic therapy in vivo.(AU)


OBJETIVO: Apresentar novo modelo de adenocarcinoma distal em camundongos atímicos. MÉTODOS: Foram utilizados sete camundongos atímicos. Desvio do cólon distal e fístula foram feitas. Células de adenocarcinoma foram inoculadas na submucosa da fístula. O crescimento do tumor foi monitorado diariamente. Cintilografia com 99mTc-MIBI foi realizada para identificar o tumor. RESULTADOS: O modelo de câncer de cólon distal é viável. Detecção do tumor foi possível macroscopicamente e por imagem molecular. Todas as ressecções demonstraram tumores pouco diferenciados. Obstrução do cólon ocorreu em um caso, de forma semelhante à evolução em tumores humanos do cólon distal. CONCLUSÃO: O modelo de câncer do cólon distal proposto é viável, permite a monitorização fácil do crescimento tumoral macroscopicamente e por imagem molecular, sendo adequado para o estudo da evolução de tumor com aplicação de terapia citotóxica in vivo.(AU)


Assuntos
Animais , Neoplasias do Colo/patologia , Camundongos Nus/classificação , Fístula
14.
Acta méd. costarric ; 52(3): 148-153, jul. - sept. 2010. ilus
Artigo em Espanhol | LILACS | ID: lil-581070

RESUMO

La coronariopatía arterio esclerótica continúa siendo la principal causa de mortalidad mundial y Costa Rica no escapa a esta realidad. La prueba de esfuerzo, la imagen de perfusión con SESTAMIBI y la angiografía coronaria son métodos que permiten detectar esta entidad. El país no cuenta con datos sobre la información que proporcionan estas pruebas. El objetivo del estudio es determinar la rentabilidad diagnóstica de cada una de ellas. Métodos: Es un estudio observacional, analítico de cohorte. Se incluyeron pacientes con factores de riesgo cardiovascular, que tuvieran prueba de esfuerzo, estudio de perfusión miocárdica y angiografía coronaria realizadas en el Hospital San Juan de Dios, desde 2003 a 2007. Se calculó la sensibilidad y especificidad de estos estudios. También se llevó a cabo un análisis con una estadística descriptiva de las características de la muestra y de los diferentes factores de riesgo cardiovascular. Resultados: Se incluyeron 83 pacientes en el estudio, 75 por ciento hombres. Los principales factores de riesgo encontrados fueron dislipidemia, 84 por ciento, e hipertensión arterial, 70 por ciento. La prueba de esfuerzo tuvo una sensibilidad del 40 por ciento y una especificidad del 57 por ciento; el estudio de perfusión miocárdica con SESTAMIBI tuvo una sensibilidad del 66 por ciento y una especificidad del 71 por ciento. La mayoría de los pacientes tuvieron afección de uno o dos vasos coronarios, con lesiones mayores al 90 por ciento, y especialmente en la arteria descendente anterior. Conclusión: Los factores de riesgo convencionales se presentaron en un alto porcentaje de la población estudiada. La prueba de esfuerzo mostró una baja sensibilidad y especificidad, sin embargo, coincide con el rango descrito en la literatura. El estudio de perfusión miocárdica con SESTAMIBI mostró un rendimiento diagnóstico significativamente superior (p=0.05).


Coronary artery disease is the first cause of mortality around the world, and Costa Rica does not escape from this reality. The treadmill test, myocardial perfusion imaging withSESTAMIBI, and coronary angiography are methods for detecting this disease. Our country does not have its own data regarding these tests. The aim of this study is to determine the diagnostic performance of each one. Methods: The present is an observational, analytic, cohort study. Patients included were those with cardiovascular risk factors that underwent a treadmill test, myocardial perfusion imaging, and a coronary angiography at the Hospital San Juan de Dios, from 2003 to 2007. Sensitivity and specificity were calculated. A descriptive statistic analysis of the different risk factors was carried out. Results: Eighty three patients were included in the study; 75% men and 25% women. The mostfrequently found risk factors were dyslipidemia (84%), and hypertension (70%). The treadmill test had a sensitivity of 40%, and specificity of 57%. Myocardial perfusion imaging withSESTAMIBI had a sensitivity of 66% and specificity of 71%. The majority of the patients had lesions in 1 or 2 coronary arteries, with more than 90% obstruction, mostly in the anterior arterydescending. Conclusion: A high prevalence of conventional risk factors was present in this population. Thetreadmill test showed a low sensitivity and specificity, according with the literature. The myocardial perfusion imaging had a significant (p =0.05) better diagnostic performance than thetreadmill test.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Cardiologia , Angiografia Coronária , Doença das Coronárias/diagnóstico , Teste de Esforço , Reperfusão Miocárdica , Perfusão , Costa Rica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA