Rev. bras. anestesiol ; Rev. bras. anestesiol;66(1): 82-85, Jan.-Feb. 2016. tab
Artigo em Português | LILACS | ID: lil-773478

RESUMO

BACKGROUND AND OBJECTIVES: Aortic stenosis increases perioperative morbidity and mortality, perioperative invasive monitoring is advised for patients with an aortic valve area <1.0 cm2 or a mean aortic valve gradient >30 mm Hg and it is important to avoid hypotension and arrhythmias. We report the anaesthetic management with continuous spinal anaesthesia and minimally invasive haemodynamic monitoring of two patients with severe aortic stenosis undergoing surgical hip repair. CASE REPORT: Two women with severe aortic stenosis were scheduled for hip fracture repair. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring was used for anaesthetic management of both. Surgery was performed successfully after two consecutive doses of 2 mg of isobaric bupivacaine 0.5% in one of them and four consecutive doses in the other. Haemodynamic conditions remained stable throughout the intervention. Vital signs and haemodynamic parameters remained stable throughout the two interventions. CONCLUSION: Our report illustrates the use of continuous spinal anaesthesia with minimally invasive haemodynamic monitoring as a valid alternative to general or epidural anaesthesia in two patients with severe aortic stenosis who are undergoing lower limb surgery. However, controlled clinical trials would be required to establish that this technique is safe and effective in these type or patients.


JUSTIFICATIVA E OBJETIVOS: A estenose aórtica aumenta a morbidade e mortalidade no período perioperatório. A monitoração invasiva no perioperatório é recomendada para pacientes com área valvar <1,0 cm2 ou gradiente médio >30 mm Hg, além de ser importante evitar a hipotensão e arritmias. Relatamos o manejo anestésico com o uso de raquianestesia contínua e monitoração hemodinâmica minimamente invasiva em duas pacientes com estenose aórtica grave, submetidas à cirurgia de reparação do quadril. RELATO DE CASO: Duas pacientes com estenose aórtica grave foram programadas para cirurgia de reparação de fratura de quadril. Raquianestesia contínua com monitoração hemodinâmica minimamente invasiva foi usada para o manejo anestésico de ambas as pacientes. A cirurgia foi realizada com sucesso após duas doses consecutivas de 2 mg de bupivacaína isobárica a 0,5% em uma das pacientes e quatro doses consecutivas na outra. As condições hemodinâmicas permaneceram estáveis durante a intervenção. Os sinais vitais e parâmetros hemodinâmicos permaneceram estáveis durante as duas intervenções. CONCLUSÃO: Nosso relato descreve o uso da raquianestesia contínua com monitoração hemodinâmica minimamente invasiva como uma alternativa válida para a anestesia geral ou peridural em duas pacientes com estenose aórtica grave, submetidas à cirurgia de membro inferior. Contudo, ensaios clínicos controlados são necessários para estabelecer que a técnica é segura e eficaz nesse tipo de pacientes.


Assuntos
Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Bupivacaína/administração & dosagem , Fraturas do Quadril/cirurgia , Raquianestesia/métodos , Estenose da Valva Aórtica/patologia , Índice de Gravidade de Doença , Monitorização Intraoperatória/métodos , Hemodinâmica
2.
Braz J Anesthesiol ; 66(1): 82-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26768936

RESUMO

BACKGROUND AND OBJECTIVES: Aortic stenosis increases perioperative morbidity and mortality, perioperative invasive monitoring is advised for patients with an aortic valve area <1.0 cm(2) or a mean aortic valve gradient >30 mmHg and it is important to avoid hypotension and arrhythmias. We report the anaesthetic management with continuous spinal anaesthesia and minimally invasive haemodynamic monitoring of two patients with severe aortic stenosis undergoing surgical hip repair. CASE REPORT: Two women with severe aortic stenosis were scheduled for hip fracture repair. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring was used for anaesthetic management of both. Surgery was performed successfully after two consecutive doses of 2mg of isobaric bupivacaine 0.5% in one of them and four consecutive doses in the other. Haemodynamic conditions remained stable throughout the intervention. Vital signs and haemodynamic parameters remained stable throughout the two interventions. CONCLUSION: Our report illustrates the use of continuous spinal anaesthesia with minimally invasive haemodynamic monitoring as a valid alternative to general or epidural anaesthesia in two patients with severe aortic stenosis who are undergoing lower limb surgery. However, controlled clinical trials would be required to establish that this technique is safe and effective in these type or patients.


Assuntos
Raquianestesia/métodos , Estenose da Valva Aórtica/complicações , Bupivacaína/administração & dosagem , Fraturas do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/patologia , Feminino , Hemodinâmica , Humanos , Monitorização Intraoperatória/métodos , Índice de Gravidade de Doença
3.
Rev. bras. educ. espec ; 19(2): 183-194, abr.-jun. 2013.
Artigo em Português | LILACS | ID: lil-679376

RESUMO

nos últimos anos a investigação tem dado particular relevância às alterações do Processamento Sensorial nas crianças com perturbações do espectro do autismo (PEA) e a literatura refere que entre 42% a 88% das crianças com PEA apresentam este tipo de disfunção. Nesta linha foi definido um projeto de investigação centrado na construção de uma escala que avalie a tradicional tríade que caracteriza as crianças com PEA (Interação, Comunicação e Comportamento e interesses repetitivos e estereotipados), enriquecida pela inclusão de um novo domínio: o Processamento Sensorial. Com a construção e validação desta escala pretendemos que pais e profissionais utilizem colaborativamente um instrumento de avaliação da intervenção que lhes permita monitorizar o processo de apoio e adequar as suas práticas. Neste artigo descrevemos os procedimentos e os resultados das sucessivas fases de construção do instrumento, desde as análises iniciais mais qualitativas até aos estudos centrados na análise quantitativa dos itens.


During the last few years, research has focused on changes in Sensory Processing in children with Autistic Spectrum Disorder (ASD). As a result, literature has shown that between 42% and 88% of children with ASD present this type of disorder. Based on these findings, a research project was designed centring on the construction of a tool to assess the traditional triad that characterizes children with ASD (Interaction, Communication and Behaviour and Repetitive and Stereotyped Interests), to which was added a new domain: Sensory Processing. By constructing and validating this assessment tool, the intention is for parents and professionals to collaboratively apply this intervention assessment instrument in order to monitor the support process and adapt their practices. In this paper, we describe procedures and results of the successive stages entailed in constructing this instrument, from the first primarily qualitative analyses up to the studies centred on the quantitative item analysis.