RESUMO
OBJECTIVES: The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using computed tomography. STUDY DESIGN: This prospective in-vitro study used 30 polyurethane pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the dental implants as a control group, considered as the gold standard for postoperative comparison. RESULTS: The difference between these methods is close to zero and not statistically significant (p > 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396. CONCLUSION: The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method.
Assuntos
Implantes Dentários , Imageamento Tridimensional , Mandíbula , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Estudos Prospectivos , Implantes Dentários/normas , Imageamento Tridimensional/métodos , Mandíbula/cirurgia , Mandíbula/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Técnicas In Vitro , Estereolitografia/normas , Implantação Dentária Endóssea/métodos , Implantação Dentária Endóssea/instrumentação , Implantação Dentária Endóssea/normas , Prótese TotalRESUMO
The indication of shoulder arthroplasties has increased progressively. Accurate positioning of the components may have significant implications for clinical results. The navigation used to aid in the performance of anatomical and reverse total arthroplasties has provided greater precision in implant placement, especially on the glenoid. The development of the technique, material, and prosthesis design have shown encouraging results and led to a trend toward its expansion. In this way, we estimate a higher survival of the arthroplasties resulting from lower rates of dislocation and early loosening. We aim to describe the current technique and to present the results of the literature with navigation. However, comparative clinical studies with long term follow-up are necessary to prove the efficacy in the final results of total shoulder arthroplasties.
RESUMO
Abstract Objective The primary aim of the present study was to evaluate the long-term outcomes including survivorship of computer navigated distal femoral lateral opening wedge osteotomy (DFLOWO). The secondary aim was to identify the potential factors that may influence its survivorship. Methods A retrospective analysis of prospectively collected data for patients with lateral compartment arthritis who underwent navigated DFLOWO from December 2006 to November 2012 was performed. The International Knee Documentation Committee (IKDC) and Knee Injury and Osteoarthritis Outcome Score (KOOS) scores were analyzed for outcome measures. Conversion to arthroplasty during the follow-up was the end point. Results A total of 19 DFLOWOs were performed in 17 patients with a mean age of 46.6 ± 6.5 years formed the study cohort. The coronal alignment was corrected from a mean of 7.1° (2-11°) valgus to a mean of 2.1° (0.5°-3°) varus. The IKDC scores improved from mean of 39 preoperatively to 53 at the mean long-term follow-up of 9.1 years. The mean KOOS scores at the long-term follow-up were pain 71, symptoms 56, activities of daily living 82, sports and recreation 59, quality of life 43. Survivorship of the DFLOWO was 78.9% at a follow-up of 9.1 years. Presence of ≥ grade 2 according to the International Cartilage Repair Society (ICRS) cartilage degeneration in the medial compartment of the knee and >7° preoperative valgus deformity were strongly correlated with conversion to total knee arthroplasty (TKA) at the long-term follow-up (r= 0.66). ConclusionsComputer navigated DFLOWO has satisfactory clinical outcomes and 79% survivorship in long-term follow-up. Presence of more than ICRS ≥ grade 2 degenerative changes in the medial compartment of knee with > 7° preoperative valgus deformity negatively affects the survivorship of DFLOWO in the long-term follow-up.
Resumo Objetivo O objetivo principal do presente estudo foi avaliar os resultados a longo prazo, incluindo a sobrevivência em Osteotomia Varizante Femoral Distal com Cunha de Abertura Lateral (OVFD-CAL) utilizando navegação computadorizada. O objetivo principal do presente estudo foi avaliar os resultados a longo prazo, incluindo a sobrevivência. Métodos Foi realizada uma análise retrospectiva dos dados coletados prospectivamente de pacientes com artrite do compartimento lateral submetidos a OVFD-CAL por navegação de dezembro de 2006 a novembro de 2012. As pontuações International Knee Documentation Committee (IKDC, na sigla em inglês) e Knee Injury and Osteoarthritis Outcome Score (KOOS, na sigla em inglês) foram analisadas para medição de resultados. Conversão para artroplastia durante o acompanhamento foi o ponto final. Resultados Um total de 19 OVFD-CAL foram realizados em 17 pacientes com média de idade de 46,6 ± 6,5 anos formaram a coorte do estudo. O alinhamento coronal foi corrigido a partir de uma média de 7,1° (2-11°) de valgo para uma média de 2,1° (0,5°-3°) de varo. As pontuações do IKDC melhoraram de uma média pré-operatória de 39 para 53 no acompanhamento de médio de longo prazo de 9,1 anos. Os escores do KOOS no acompanhamento a longo prazo foram: dor 71, sintomas 56, atividades da vida diária 82, esportes e recreação 59, qualidade de vida 43. A sobrevivência do OVFD-CAL foi de 78,9% em um acompanhamento de 9,1 anos. Presença de degeneração da cartilagem segundo a Sociedade Internacional de Reparação de Cartilagem (International Cartilage Repair Society [ICRS, na sigla em inglês])≥ grau 2 no compartimento medial do joelho e deformidade pré-operatória em valgo > 7° fortemente correlacionado com a conversão para artroplastia total do joelho (ATJ) no acompanhamento a longo prazo (r - 0,66). ConclusõesA OVFD-CAL por navegação computadorizada apresentou resultados clínicos satisfatórios e sobrevida de 79% no acompanhamento a longo prazo. Presença de alterações degenerativas ICRS ≥ grau 2 no compartimento medial do joelho com > 7° de deformidade pré-operatória em valgo afeta negativamente a sobrevivência da OVFD-CAL no acompanhamento de longo prazo.
Assuntos
Humanos , Masculino , Feminino , Osteoartrite , Osteotomia , Avaliação de Resultados em Cuidados de Saúde , Artroplastia do Joelho , Cirurgia Assistida por Computador , Traumatismos do JoelhoRESUMO
Maxillary sinus pneumatisation pose a grave clinical challenge for implant fixed rehabilitation in posterior maxilla owing to diminished bone volume. This necessitates sinus lift and grafting which increase the duration and cost and possible surgical complications. Pterygoid implant has a greater short term osseointegration and is a proven treatment method for rehabilitation of highly resorbed posterior maxilla. To overcome the limitations of sinus grafting techniques, the current case report describes the use of flapless, tilted and pterygoid implant for restoration of partially edentulous atrophic maxilla eliminating grafting (AU).
A pneumatização do seio maxilar representa um grande desafio clínico para a reabilitação fixa por implante na região posterior da maxila devido ao volume ósseo diminuído. Isso requer elevação do seio e enxerto, fatores que aumentam a duração, o custo e as possíveis complicações cirúrgicas. O implante pterigóide tem uma osseointegração maior em curto prazo e é um método de tratamento comprovado para reabilitação de maxila posterior altamente reabsorvida. Para superar as limitações das técnicas de enxerto de seio, o relato de caso atual descreve o uso de implante sem retalho, inclinado e pterigóide para restauração de maxila atrófica parcialmente edêntula eliminando o enxerto.(AU)
Assuntos
Humanos , Pessoa de Meia-Idade , Relatos de Casos , Implantes Dentários , Arcada Parcialmente Edêntula , Cirurgia Assistida por Computador , Carga Imediata em Implante DentárioRESUMO
Introdução: Avaliar os níveis de conhecimento, interesse e treinamento dos cirurgiões inscritos no Colégio Brasileiro dos Cirurgiões (CBC) da cidade de Porto Alegre, Rio Grande do Sul, em relação à cirurgia robótica. Métodos: Estudo transversal, baseado em informações coletadas por meio de questionário enviado via plataforma digital para potenciais participantes. O formulário continha perguntas estruturadas e autoaplicáveis, a fim de caracterizar o perfil profissional, capacitação em cirurgia minimamente invasiva, conhecimento, opinião e treinamento específico em cirurgia robótica. Resultados: Dos 146 membros inscritos no CBC na cidade de Porto Alegre, 99 (67,8%) responderam ao questionário. Houve predomínio do sexo masculino (88%) e a mediana de idade dos participantes foi de 48 anos. Os procedimentos videolaparoscópicos ou vídeo-assistidos foram maioria na rotina dos cirurgiões. Da totalidade da amostra, a maior parte (78%) já assistiu ao menos um procedimento robótico, e um terço (n = 30) já realizou algum tipo de treinamento ou simulação em cirurgia robótica. Entre os que não realizaram, dois terços pretendem se qualificar no futuro. Apenas 10% dos cirurgiões possuem certificação na área. Conclusão: A maioria dos cirurgiões respondentes inscritos no CBC em Porto Alegre tem em sua rotina predominância de procedimentos minimamente invasivos e acredita que a plataforma robótica será o futuro da cirurgia. Embora ainda não disponível na maioria dos serviços gaúchos, espera-se que o desenvolvimento de novas plataformas e a redução dos custos envolvidos na aquisição de equipamento e de capacitação do cirurgião facilitem a disseminação dessa tecnologia.
Introduction: To assess the practical knowledge, interest, and training levels of surgeons enrolled in the Brazilian College of Surgeons (CBC) of the municipality of Porto Alegre, Rio Grande do Sul, regarding robotic surgery. Methods: Cross-sectional study, based on information collected with a questionnaire sent to potential participants via digital platform. The form contained structured and self-administered questions, to characterize their professional profile, skills in minimally invasive surgery, knowledge, opinion, and specific training in robotic surgery. Results: Of the 146 members enrolled in the CBC of the municipality of Porto Alegre, 99 (67.8%) responded to the questionnaire. Most were males (88%) with a mean age of 48 years. Video-laparoscopic or video-assisted procedures were the most frequent in the participants' practice. Of the sample, most (78%) already watched at least one robotic surgery, and one third (n = 30) had already completed some sort of training or simulation course in robotic surgery. Among those who did not, two thirds intend to pursue formal training in the future. Only 10% of participating surgeons are certified in the area. Conclusion: Most responding surgeons enrolled in the CBC in Porto Alegre perform mostly minimally invasive procedures daily and believe that the robotic technology will be the future of surgery. Although not yet available in most services of the state of Rio Grande do Sul, it is expected that the development of new platforms and the reduction of costs involved in equipment acquisition and surgical training will facilitate the dissemination of this technology.
Assuntos
Procedimentos Cirúrgicos Robóticos/educação , Cirurgiões , Estudos Transversais , Competência Clínica , Treinamento por SimulaçãoRESUMO
BACKGROUND: Congenital high airway obstruction syndrome (CHAOS) involves the partial or complete obstruction of the fetal upper airways, usually caused by atresia or stenosis of the larynx or trachea. The obstruction of bronchial tree leads to lung distension, diaphragmatic eversion, and cardiac dysfunction, which can result in fetal death. CASE: A primigravid 19-year-old was diagnosed with CHAOS at 193 weeks gestation. Virtual navigation using magnetic resonance imaging (MRI) data was used to visualize the fetal airways after intrauterine endoscopic laser decompression. A perforation in the fetal larynx/trachea was identified and the diagnosis was modified to tracheal stenosis. Cesarean delivery occurred at 315 weeks using an ex utero intrapartum treatment (EXIT) procedure. The neonatology team were unable to perform intubation, suggesting a final diagnosis of tracheal atresia. The male newborn weighed 1920 g and died 1 hour later. CONCLUSION: 3D virtual bronchoscopy is a non-invasive approach to visualizing the fetal upper airways and can be used to diagnose and manage CHAOS.
Assuntos
Obstrução das Vias Respiratórias , Doenças Fetais , Laringe , Adulto , Obstrução das Vias Respiratórias/diagnóstico por imagem , Obstrução das Vias Respiratórias/etiologia , Obstrução das Vias Respiratórias/cirurgia , Feminino , Humanos , Recém-Nascido , Laringe/diagnóstico por imagem , Laringe/cirurgia , Masculino , Gravidez , Traqueia/diagnóstico por imagem , Traqueia/cirurgia , Ultrassonografia Pré-Natal , Adulto JovemRESUMO
Abstract Introduction: Various surgical procedures for minimally invasive cardiac surgery have been described in recent decades as alternatives to median sternotomy. Cardiopulmonary bypass via femoral arterial and venous cannulation is the foundation of these procedures. In this study, we evaluated the mid-term outcomes of femoral cannulation performed with U-suture technique in patients undergoing robotic heart surgery. Methods: A total of 216 patients underwent robotic-assisted cardiac surgery between January 2013 and April 2017. Cardiopulmonary bypass was performed via femoral artery, jugular, and femoral vein cannulation, and a Chitwood clamp was used for aortic occlusion. A total of 192 patients attended the outpatient follow-up, and femoral arterial and venous flow pattern was examined using Doppler ultrasound (DUS) in 145 patients. Results: Hospital mortality occured in 4 of the 216 (1.85%) cases, but there was no late mortality in this patient group. Postoperatively, seroma (n=9, 4.69%) and cannulation site infection (n=3, 1.56%) were managed with outpatient treatment. DUS in 145 patients revealed triphasic flow pattern in the common femoral arteries in all patients except for 2 (1.38%). These patients were determined to have asymptomatic arterial stenosis. Chronic recanalized thrombus in the common femoral vein was also detected in 2 (1.38%) patients. Conclusion: Femoral artery cannulation with the U-suture technique can be successfully performed in robotic-assisted cardiac surgery, with good mid-term results.
Assuntos
Humanos , Masculino , Feminino , Adulto , Arteriopatias Oclusivas/cirurgia , Ponte Cardiopulmonar/métodos , Procedimentos Cirúrgicos Robóticos , Velocidade do Fluxo Sanguíneo , Ponte Cardiopulmonar/efeitos adversos , Seguimentos , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos , Artéria Femoral , Veia FemoralRESUMO
Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these "hotspots" was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3-8) and the median time needed to identify them was 3.5 minutes (range, 3.3-4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising.
RESUMO
OBJECTIVE: To evaluate the accuracy and the effect of drill guide template for pedicle screw placement in severe scoliosis. METHOD: Eight patients with rigid scoliosis were enrolled, five males and three females, ranging from nine to 23 years old. A three-dimensional CT scan of the spine was performed and saved as a DICOM file type. The multi-level template was designed by Mimics software and manufactured according to the part of the most severe deformity. The drill template was placed on the corresponding vertebral surface. Pedicle screws were carefully inserted across the trajectory of the template. Postoperatively, the positions of the pedicle screws were evaluated by CT scan and graded for validation. RESULTS: No spinal cord injury or nerve damage occurred. All patients had satisfactory outcomes. The abnormalities and the measures observed during operation were the same as those found in the preoperative period. The position of the pedicle screws was accurate, according to the postoperative X-ray and CT scan. The rate of scoliosis correction was 60%. Compared with controls, surgery time, blood loss and radiation were significantly lower. CONCLUSION: With the application of multi-level template, the placement of pedicle screws shows high accuracy in scoliosis with shorter surgical time, less blood loss and less radiation exposure. Level of Evidence III, Retrospective Comparative Study.
OBJETIVO: Avaliar a precisão e o efeito da matriz de guia de broca para colocação de parafuso pedicular em escoliose grave. MÉTODO: Oito pacientes com escoliose rígida foram selecionados, sendo cinco homens e três mulheres na faixa etária de nove a 23 anos. Foi realizada TC tridimensional da coluna, gravada no formato DICOM. A matriz multinível foi desenhada pelo software Mimics e fabricada de acordo com a parte da deformidade mais grave. A matriz da broca foi colocada na superfície vertebral correspondente. Os parafusos pediculares foram cuidadosamente inseridos ao longo da trajetória da matriz. No pós-operatório, as posições dos parafusos pediculares foram avaliadas por TC e classificadas para validação. RESULTADOS: Não ocorreu nenhuma lesão da medula espinhal nem lesão de nervos. Todos os pacientes tiveram desfechos satisfatórios. As anormalidades e as medidas observadas durante a operação foram as mesmas encontradas no pré-operatório. A posição dos parafusos pediculares foi precisa, de acordo com a radiografia e a TC pós-operatórias. A taxa de correção de escoliose foi de 60%. Em comparação com os controles, o tempo de cirurgia, a perda de sangue e a radiação foram significantemente menores. CONCLUSÃO: Com a aplicação da matriz multinível, a colocação dos parafusos pediculares mostra alta precisão na escoliose, com menor tempo cirúrgico, menos perda de sangue e menor exposição à radiação. Nível de Evidência III, Estudo Retrospectivo Comparativo.
RESUMO
OBJECTIVE: To prove the accuracy of a customized guide developed according to our method. METHODS: This customized guide was developed from a three-dimensional model of proximal femur reconstructed using computed tomography data. Based on the new technique, the position of the guide pin insertion was selected and adjusted using the reference of the anatomical femoral neck axis. The customized guide consists of a hemispheric covering designed to fit the posterior part of the femoral neck. The performance of the customized guide was tested in eight patients scheduled for total hip arthroplasty. The stability of the customized guide was assessed by orthopedic surgeons. An intraoperative image intensifier was used to assess the accuracy. RESULTS: The customized guide was stabilized with full contact and was fixed in place in all patients. The mean angular deviations in relation to the what was planned in anteroposterior and lateral hip radiographs were 0.5º ± 1.8º in valgus and 1.0º ± 2.4º in retroversion, respectively. CONCLUSION: From this pilot test, the authors suggest that the proposed technique could be applied as a customized guide to the positioning device for hip resurfacing arthroplasty with acceptable accuracy and user-friendly interface. Level of Evidence IV, Cases Series.
OBJETIVO: Comprovar a precisão de uma guia personalizada desenvolvida a partir de nosso método. MÉTODOS: Esta guia personalizada foi desenvolvida a partir do modelo tridimensional da parte proximal do fêmur reconstruída usando dados de tomografia computadorizada. Com base na nova técnica, a posição de inserção do pino da guia foi selecionada e ajustada usando a referência do eixo anatômico do colo do fêmur. A guia personalizada consiste em um revestimento hemisférico projetado para encaixar na parte posterior do colo do fêmur. O desempenho da guia personalizada foi testado em oito pacientes que seriam submetidos à artroplastia total do quadril. A estabilidade da guia personalizada foi avaliada por cirurgiões ortopedistas. Para avaliar a precisão, usou-se um intensificador de imagem intraoperatório. RESULTADOS: A guia personalizada foi estabilizada com contato total e foi fixada em todos os pacientes. Os desvios angulares médios com relação ao planejado nas radiografias anteroposteriores e laterais do quadril foram de 0,5º ± 1,8º em valgo e 1,0º ± 2,4º em retroversão, respectivamente. CONCLUSÃO: A partir deste teste piloto, os autores sugerem que a técnica proposta poderia ser aplicada como guia personalizada para o dispositivo de posicionamento para resurfacing em artroplastia de quadril com aceitável precisão e interface amigável. Nível de Evidência IV, Série de Casos .
RESUMO
ABSTRACT Objective: To evaluate the accuracy and the effect of drill guide template for pedicle screw placement in severe scoliosis. Method: Eight patients with rigid scoliosis were enrolled, five males and three females, ranging from nine to 23 years old. A three-dimensional CT scan of the spine was performed and saved as a DICOM file type. The multi-level template was designed by Mimics software and manufactured according to the part of the most severe deformity. The drill template was placed on the corresponding vertebral surface. Pedicle screws were carefully inserted across the trajectory of the template. Postoperatively, the positions of the pedicle screws were evaluated by CT scan and graded for validation. Results: No spinal cord injury or nerve damage occurred. All patients had satisfactory outcomes. The abnormalities and the measures observed during operation were the same as those found in the preoperative period. The position of the pedicle screws was accurate, according to the postoperative X-ray and CT scan. The rate of scoliosis correction was 60%. Compared with controls, surgery time, blood loss and radiation were significantly lower. Conclusion: With the application of multi-level template, the placement of pedicle screws shows high accuracy in scoliosis with shorter surgical time, less blood loss and less radiation exposure. Level of Evidence III, Retrospective Comparative Study.
RESUMO Objetivo: Avaliar a precisão e o efeito da matriz de guia de broca para colocação de parafuso pedicular em escoliose grave. Método: Oito pacientes com escoliose rígida foram selecionados, sendo cinco homens e três mulheres na faixa etária de nove a 23 anos. Foi realizada TC tridimensional da coluna, gravada no formato DICOM. A matriz multinível foi desenhada pelo software Mimics e fabricada de acordo com a parte da deformidade mais grave. A matriz da broca foi colocada na superfície vertebral correspondente. Os parafusos pediculares foram cuidadosamente inseridos ao longo da trajetória da matriz. No pós-operatório, as posições dos parafusos pediculares foram avaliadas por TC e classificadas para validação. Resultados: Não ocorreu nenhuma lesão da medula espinhal nem lesão de nervos. Todos os pacientes tiveram desfechos satisfatórios. As anormalidades e as medidas observadas durante a operação foram as mesmas encontradas no pré-operatório. A posição dos parafusos pediculares foi precisa, de acordo com a radiografia e a TC pós-operatórias. A taxa de correção de escoliose foi de 60%. Em comparação com os controles, o tempo de cirurgia, a perda de sangue e a radiação foram significantemente menores. Conclusão: Com a aplicação da matriz multinível, a colocação dos parafusos pediculares mostra alta precisão na escoliose, com menor tempo cirúrgico, menos perda de sangue e menor exposição à radiação. Nível de Evidência III, Estudo Retrospectivo Comparativo.
RESUMO
ABSTRACT Objective: To prove the accuracy of a customized guide developed according to our method. Methods: This customized guide was developed from a three-dimensional model of proximal femur reconstructed using computed tomography data. Based on the new technique, the position of the guide pin insertion was selected and adjusted using the reference of the anatomical femoral neck axis. The customized guide consists of a hemispheric covering designed to fit the posterior part of the femoral neck. The performance of the customized guide was tested in eight patients scheduled for total hip arthroplasty. The stability of the customized guide was assessed by orthopedic surgeons. An intraoperative image intensifier was used to assess the accuracy. Results: The customized guide was stabilized with full contact and was fixed in place in all patients. The mean angular deviations in relation to the what was planned in anteroposterior and lateral hip radiographs were 0.5º ± 1.8º in valgus and 1.0º ± 2.4º in retroversion, respectively. Conclusion: From this pilot test, the authors suggest that the proposed technique could be applied as a customized guide to the positioning device for hip resurfacing arthroplasty with acceptable accuracy and user-friendly interface. Level of Evidence IV, Cases Series.
RESUMO Objetivo: Comprovar a precisão de uma guia personalizada desenvolvida a partir de nosso método. Métodos: Esta guia personalizada foi desenvolvida a partir do modelo tridimensional da parte proximal do fêmur reconstruída usando dados de tomografia computadorizada. Com base na nova técnica, a posição de inserção do pino da guia foi selecionada e ajustada usando a referência do eixo anatômico do colo do fêmur. A guia personalizada consiste em um revestimento hemisférico projetado para encaixar na parte posterior do colo do fêmur. O desempenho da guia personalizada foi testado em oito pacientes que seriam submetidos à artroplastia total do quadril. A estabilidade da guia personalizada foi avaliada por cirurgiões ortopedistas. Para avaliar a precisão, usou-se um intensificador de imagem intraoperatório. Resultados: A guia personalizada foi estabilizada com contato total e foi fixada em todos os pacientes. Os desvios angulares médios com relação ao planejado nas radiografias anteroposteriores e laterais do quadril foram de 0,5º ± 1,8º em valgo e 1,0º ± 2,4º em retroversão, respectivamente. Conclusão: A partir deste teste piloto, os autores sugerem que a técnica proposta poderia ser aplicada como guia personalizada para o dispositivo de posicionamento para resurfacing em artroplastia de quadril com aceitável precisão e interface amigável. Nível de Evidência IV, Série de Casos .
RESUMO
O planejamento virtual para cirurgia guiada é uma técnica que vem sendo cada vez mais utilizada na Implantodontia. Sendo assim, o objetivo desse estudo foi realizar uma revisão da literatura sobre a técnica de planejamento virtual para cirurgia guiada sem retalho em reabilitação oral com implantes osseointegráveis, de modo a fornecer informação sobre as características, vantagens e limitações dessa modalidade. Diversos estudos demonstraram a confiabilidade e vantagens da técnica quanto à precisão do planejamento, inserção dos implantes, fabricação da prótese e satisfação do paciente. No entanto, alguns autores relataram que desvios podem ocorrer quanto ao posicionamento dos implantes em relação ao planejamento virtual, o que ressalta a importância da utilização do guia cirúrgico, bem como precisão durante a execução de todas as etapas clínicas e laboratoriais. Concluiu-se que, apesar das limitações relatadas por alguns autores, o método apresenta diversas vantagens que garantem a sua previsibilidade quando indicado e executado corretamente (AU).
The virtual planning for guided surgery has been a widely used technique in Implantology. Thus, the aim of this study was to conduct a literatura review about the virtual planning for flapless guided surgery in oral rehabilitation with dental implants regarding its characteristics, advantages, and limitations. Several studies demonstrated the reliability and advantages of this approach as a consequence of accuracy during treatment planning, implants insertion, prosthesis fabrication, and patient's satisfaction. However, some authors reported deviations of implants positioning compared to the virtual planning, which highlighted the importance of using the surgical guide as well as the accuracy during all clinical and laboratorial steps. Despite of the limitations demonstrated by some authors, it was concluded that this method presents several advantages to enhance its predictability when the procedures are well indicated and performed (AU).
Assuntos
Implantes Dentários , Planejamento de Prótese Dentária/métodos , Cirurgia Assistida por Computador , Cirurgia Assistida por Computador/instrumentação , Brasil , Tomografia Computadorizada por Raios X/instrumentação , Reabilitação BucalRESUMO
O sucesso da cirurgia ortognática depende da técnica cirúrgica e da acurácia do planejamento. O planejamento em cirurgia ortognática tem evoluído muito nas últimas duas décadas, especialmente em relação ao desenvolvimento do planejamento cirúrgico virtual tridimensional. O objetivo deste estudo foi avaliar, através de metodologia tridimensional, a acurácia do planejamento cirúrgico virtual realizado pelo programa Dolphin Imaging®. A amostra do trabalho foi composta por 10 indivíduos, de ambos os sexos, sem crescimento, portadores de má oclusões de Classe II ou classe III, que necessitassem de cirurgia bimaxilar mais mentoplastia, para correção da deformidade, acompanhados de forma prospectiva. Todos os pacientes foram operados pela equipe de cirurgia bucomaxilofacial do Hospital Universitário Pedro Ernesto. A documentação dos pacientes era composta por tomografia computadorizada de feixe cônico (CBCT), modelos das arcadas e fotografias pré-operatórias e CBCT pós-operatória. Os planejamentos virtuais foram realizados pelo módulo cirúrgico do programa e transferidos para o momento da cirurgia, através de uma goteira interoclusal obtido por prototipagem. A acurácia foi avaliada com o uso dos programas ITK-Snap 3.6, Geomagic Qualify® 2013 e MeshValmet® 3.0. Foram feitas avaliações para a diferença entre o planejamento virtual e o obtido na cirurgia real em relação à superfície dos segmentos, com avaliação utilizando o valor de Root Mean Square (RMS) do deslocamento de cada fragmento, e em relação aos deslocamentos translacionais das regiões anatômicas de interesse, medidos através do cálculo do deslocamento tridimensional dos centroides das estruturas avaliadas. Os dados das distâncias entre superfícies, considerando o RMS, foram realizados pelo teste de Wilcoxon para uma amostra. Os dados da diferença de posicionamento entre os centroides foram calculados pelo teste t, pareado e complementados pelo método de Altman-Bland e por gráficos de Concordância-sobrevivência. Os resultados mostraram que houve diferença estatisticamente significativa em relação à avaliação da distância entre as superfícies para o posicionamento da mandíbula (p=0,013) e do mento (p=0,013) e em relação ao posicionamento dos centroides na direção transversal do ramo direito (p=0,034), quando considerado o sentido do deslocamento, e na direção vertical dos ramos direito (p=0,005) e esquerdo (p=0,025), quando não considerado o sentido do deslocamento. Em relação à medida de relevância clínica aceitável, comumente considerada de 2mm, observou-se acurácia para os segmentos da maxila, proximais (ramos) e distais (corpo) da mandíbula, mas não observou-se para o segmento do mento. Concluiu-se que o planejamento cirúrgico virtual, realizado pelo módulo cirúrgico do Dolphin Imaging®, apresenta boa acurácia para determinar o posicionamento dos segmentos da maxila, ramos e corpo mandibular, mas não pode ser considerado como tendo adequada acurácia para o posicionamento do mento sem uso de posicionador específico.
The success of orthognathic surgery depends on the surgical technique and on the accuracy of its planning. Planning in orthognathic surgery has evolved over the last two decades especially due to the development of three-dimensional virtual surgical planning. The objective of this study was to assess the accuracy of virtual surgical planning performed by the Dolphin Imaging© software through a three-dimensional methodology. The sample consisted of 10 individuals of both genders, after the growth period, with Class II or Class III malocclusions, requiring bimaxillary surgery and genioplasty. Those patients were followed up prospectively. The maxillofacial surgery staff of Pedro Ernesto University Hospital conducted all surgeries. Patient documentation consisted of preoperative cone beam computed tomography (CBCT), plaster models of upper and lower arches, photographs, and postoperative CBCT. The virtual planning were performed with the surgical module of the software. A prototyped interocclusal splint was used to transfer the digital planning to the real surgery. The accuracy was tested using the softwares ITK-Snap 3.6, Geomagic Qualify 2013© and MeshValmet 3.0. The difference between the virtual planning and actual surgery was calculated for the segments, using the root mean square (RMS) value of displacement of each individual fragment, and the translational displacements of the anatomical regions of interest (ROI) were measured through the three-dimensional displacement of the 3D centroid of each model. The data of the distances between surfaces considering RMS was analyzed by the Wilcoxon rank test. The data of differences between the centroids positions was calculated by the paired t-test and complemented by the Altman-Bland method and the Survival Agreement. The results showed that the distance between the surfaces were significantly different when considering the mandible position (p = 0.013) and the chin (p = 0.013). According to the position of the centroids it was found significant difference in the transverse direction of the right ramus (p = 0.034) when the direction of the displacement was taken into account and in the vertical direction of the right ramus (p = 0.005) and left ramus (p = 0.025) when the direction of the displacement was not considered. Considering a clinical relevance threshold of 2mm, it can be assumed that the segments of the maxilla, proximal (ramus) and distal (body) of the mandible were accurate, but the chin segment was not. It was concluded that the virtual surgical planning performed by the Dolphin Imaging© surgical module is accurate to determine the positioning of the maxilla, ramus and mandibular body segments, but can not be considered as having adequate accuracy for the positioning of the chin without the use of a specific positioner
Assuntos
Humanos , Masculino , Feminino , Adulto , Adulto Jovem , Validação de Programas de Computador , Desenho Assistido por Computador , Imageamento Tridimensional , Cirurgia Assistida por Computador , Procedimentos Cirúrgicos Ortognáticos/métodos , Má Oclusão/cirurgia , Confiabilidade dos DadosRESUMO
Objetivo: este estudo foi idealizado com a finalidade de comparar as posições dos análogos em modelos de gesso, obtidos antes e após o procedimento cirúrgico de instalação dos implantes, em dez casos clínicos. Material e métodos: foram selecionados dez guias prototipados de maxilas edêntulas, que já haviam sido utilizados para a instalação guiada de implantes e que já estavam com as próteses instaladas. Cilindros posicionadores de análogos de minipilar foram adaptados para obtenção dos modelos de gesso pré-cirúrgicos (modelo 1). Também foram reunidos os modelos dos casos que haviam sido obtidos através da moldagem realizada em boca após a instalação dos intermediários (modelo 2). Todos foram submetidos a escaneamento a laser, e a comparação entre os modelos foi realizada virtualmente com um software específico. Os dados foram analisados estatisticamente utilizando o teste de Wilcoxon (p < 0,05). Resultados: foi encontrada uma média de desvio angular de 3,17o ± 1,78o (p=0,000). A média do desvio angular encontrada na comparação entre os dois modelos avaliados foi semelhante a desvios encontrados na literatura. Conclusão: técnicas como a da adaptação passiva devem ser utilizadas com o objetivo de compensar tais desvios e facilitar o procedimento técnico laboratorial, entregando a prótese final em menos tempo.
Objective: this study compared the positions of the analogs in plaster models obtained before and after implant placement in 10 clinical cases. Material and methods: ten CAD/CAM surgical guides for maxillary edentulous patients were selected and which had already been used for the guided implant placement and with the final prosthesis already fabricated. To generate the pre-surgical cast model (model 1), mini conical replicas were mounted on the guiding sleeves using cylinder positioners. The models obtained through an impression after the surgical procedures were also analyzed (model 2). Each plaster model was subjected to laser scanning and the comparison between models was performed in specialized software. The statistical analyses were performed using Wilcoxon test (p < 0.05). Results: a mean angular deviation of 3.17o ± 1.8o (p=0.000) was found. The average angular deviation found in the comparison between the two models evaluated was similar to deviations in the literature. Conclusion: techniques such as passive adaptation, must be used in order to compensate the deviations and improve laboratory procedures, speeding the final denture delivery in less time.
Assuntos
Humanos , Desenho Assistido por Computador , Implantes Dentários , Imageamento Tridimensional , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios XRESUMO
OBJETIVO: O presente trabalho busca o desenvolvimento de uma solução de tecnologia que possa auxiliar o tratamento e edição de imagens para um planejamento semiautomatizado de tratamento de dentes caninos inclusos. MÉTODOS: Para isto foi verificado no âmbito do LT3D/NUTES casos clínicos de dentes caninos inclusos e requisitos de um biomodelo para melhor apoiar o planejamento e execução do tratamento ortodôntico. De posse dos requisitos, foram feitas análises em dez softwares de modelagem tridimensional visando identificar o cumprimento das tarefas elencadas como essenciais para a simulação do tratamento supracitado. RESULTADO: Resumo da análise dos softwares contendo as combinações de funcionalidades que permitem o auxílio no planejamento do tratamento.
OBJECTIVE: This work aims to develope technology solution that makes use of image treatment and editing software tools to support a semi-automated treatment planning of impacted canine teeth. METHODS: For this purpose clinical cases of canine teeth in the LT3D / NUTES were studied and a set of requirements were defined for a biomodel to better support the planning and execution of orthodontic treatment. Based on the requirements, ten 3D design software tool were analysed to verify the fulfillment of the set of tasks (requirements) listed as essential to simulate the orthodontic treatment. RESULTS: We provide a summarized analysis of the software studied containing combinations of features that make the semi-automated treatment planning possible.
Assuntos
Humanos , Procedimentos Cirúrgicos Bucais , Cirurgia Assistida por Computador , Impressão Tridimensional , Congressos como AssuntoRESUMO
Objectives: To evaluate the accuracy and the operative complications of implanting pedicle screws in the thoracic and lumbar spine, using computer-assisted surgery compared to the implantation technique using fluoroscopy. Methods: A retrospective study was conducted at the Hospital Universitário Cajuru PUC-PR from January 2000 to January 2009. Two groups of patients undergoing implant pedicle screws were analyzed (n=80). Group I received implant pedicle screws through fluoroscopy technique and group II, through neuronavigation technique. The accuracy of positioning of pedicle screws was evaluated using rating scales. Results: The accuracy was higher in group II, where 77.5% of the screws were correctly positioned, whereas there were only 28.5% in group I (p=0.001). There was a reduction of 95% (CI: 80-97%) in the risk of screws misplacement in group II. The average operation time was 312.2±78.1 minutes in group I and 270.3±41.4 in group II (p=0.004). Blood transfusion was needed in 28 patients in group I and 10 patients in group II (p=0.005), resulting in 64% risk reduction of blood transfusion in group II. Eight patients in group I underwent revision surgery whereas only one patient in the group II, that is, 75% of surgical revision risk reduction. Conclusion: The implantation technique of pedicle screws using neuronavigation is a more accurate method and has less operative complications compared with the technique that uses fluoroscopy.
Objetivos: Avaliar a precisão e as complicações operatórias do implante de parafusos pediculares na coluna torácica e lombar, utilizando o método de cirurgia assistida por computação comparada à técnica de implante utilizando fluoroscopia. Métodos: Um estudo retrospectivo foi realizado no Hospital Universitário Cajuru PUC/PR de janeiro de 2000 a janeiro de 2009. Dois grupos de pacientes submetidos a implante de parafusos pediculares foram analisados (n = 80). O grupo I recebeu implante de parafusos pediculares com técnica de fluoroscopia e o grupo II, com técnica de neuronavegação. A precisão dos parafusos pediculares foi avaliada utilizando-se escalas de graduação. Resultados: A precisão do posicionamento dos parafusos foi superior no grupo II, no qual 77,5% dos parafusos estavam corretamente posicionados, enquanto havia somente 28,5% no grupo I (p = 0,001). Houve 95% (IC: 80-97%) de redução do risco de mau posicionamento de parafusos no grupo II. A média de tempo cirúrgico foi de 312,2 ± 78,1 minutos no grupo I e 270,3 ± 41,4 no grupo II (p = 0,004). Houve necessidade de transfusão sanguínea em 28 pacientes do grupo I e em somente 10 no grupo II (p = 0,005), resultando em 64% de redução de risco de transfusão sanguínea no grupo II. Oito pacientes no grupo I foram submetidos à revisão da cirurgia enquanto somente um no grupo II, ou seja, 75% de redução de risco de revisão cirúrgica. Conclusão: A técnica de implante de parafusos pediculares utilizando neuronavegação é um método mais preciso e tem menor complicações operatórias quando comparada com a técnica que utiliza a fluoroscopia.
Objetivos: Evaluar la precisión y las complicaciones operatorias de la implantación de tornillos pediculares en la columna torácica y lumbar, utilizando el método de cirugía asistida por computación en comparación con la técnica de implantación mediante fluoroscopía. Métodos: Un estudio retrospectivo se llevó a cabo en el Hospital Universitário Cajuru PUC-PR desde enero de 2000 a enero de 2009. Se analizaron dos grupos de pacientes sometidos a implante de tornillos pediculares (n = 80). El grupo I ha recibido implantación de tornillos pediculares con la técnica fluoroscópica y el grupo II, con la técnica de neuronavegación. La exactitud de la colocación de los tornillos pediculares se evaluó mediante escalas de clasificación. Resultados: La precisión de la colocación de los tornillos fue mayor en el grupo II, en el que 77,5% de los tornillos fueron correctamente colocados, mientras que sólo había 28,5% en el grupo I (p = 0, 001). Hubo 95% (IC: 80-97%) de reducción en el riesgo de mala posición de tornillos en el grupo II. El tiempo quirúrgico promedio fue de 312,2 ± 78,1 minutos en el grupo I y 270,3 ± 41,4 en el grupo II (p = 0,004). Hubo necesidad de transfusión de sangre en 28 pacientes del grupo I y sólo 10 en grupo II (p = 0, 005), lo que resulta en la reducción del riesgo del 64% de las transfusiones de sangre en el grupo II. Ocho pacientes del grupo I se sometieron a cirugía de revisión, mientras que sólo un paciente en el grupo II, es decir, el 75% de reducción del riesgo de revisión quirúrgica. Conclusión: La técnica de implantación de tornillos pediculares utilizando neuronavegación es un método preciso y tiene menos complicaciones operatorias en comparación con la técnica que utiliza la fluoroscopía.
Assuntos
Humanos , Coluna Vertebral/cirurgia , Fluoroscopia , Cirurgia Assistida por Computador , Parafusos PedicularesRESUMO
PURPOSE: To evaluate the efficacy of associating techniques of bone grafting in the maxillary sinus with the use of a prototyped surgical guide for planning and positioning dental implants in total edentulous maxillae, rehabilitated after six months. METHODS: Eight patients consecutives with totally edentulous maxilla presenting few remaining bone in the posterior alveolar ridge, associated with pneumatization of the maxillary sinus were selected. Twenty eight Brånemark RP 10mm implants were installed in 14 maxillary sinuses. The surgical planning for the implant installation was performed with the DentalSlice software by means of a computerized tomography. The obtained images were used for building a surgical guide that, placed over the maxilla, showed the exact position for the implants installation (prototyped surgical guide). The portion of the implants that went into the maxillary sinus was covered by an autogenous bone graft. RESULTS: The patients were re-evaluated six months after the surgery and a 100% success rate was achieved. All of the implants presented no mobility or symptoms, permitting an oral rehabilitation with total fixed screw-retained prosthesis over the implants. CONCLUSION: The technique of associating implants and bone graft in the maxillary sinus aided by a prototyped guide planned on DentalSlice has showed itself efficient for positioning implants and for quantifying and locating the bone graft.(AU)
Assuntos
Humanos , Animais , Implante de Prótese Maxilofacial , Osso e Ossos/anatomia & histologia , Próteses Articulares Metal-MetalRESUMO
PURPOSE: To evaluate the efficacy of associating techniques of bone grafting in the maxillary sinus with the use of a prototyped surgical guide for planning and positioning dental implants in total edentulous maxillae, rehabilitated after six months. METHODS: Eight patients consecutives with totally edentulous maxilla presenting few remaining bone in the posterior alveolar ridge, associated with pneumatization of the maxillary sinus were selected. Twenty eight Brånemark RP 10mm implants were installed in 14 maxillary sinuses. The surgical planning for the implant installation was performed with the DentalSlice software by means of a computerized tomography. The obtained images were used for building a surgical guide that, placed over the maxilla, showed the exact position for the implants installation (prototyped surgical guide). The portion of the implants that went into the maxillary sinus was covered by an autogenous bone graft. RESULTS: The patients were re-evaluated six months after the surgery and a 100% success rate was achieved. All of the implants presented no mobility or symptoms, permitting an oral rehabilitation with total fixed screw-retained prosthesis over the implants. CONCLUSION: The technique of associating implants and bone graft in the maxillary sinus aided by a prototyped guide planned on DentalSlice has showed itself efficient for positioning implants and for quantifying and locating the bone graft.
Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transplante Ósseo/métodos , Desenho Assistido por Computador , Implantes Dentários , Implantação Dentária Endóssea/métodos , Seio Maxilar/cirurgia , Simulação por Computador , Planejamento de Prótese Dentária , Precisão da Medição Dimensional , Arcada Edêntula/reabilitação , Seio Maxilar , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
Na tentativa de preservação dos tecidos mole e duro, a implantodontia tem optado por uma abordagem cirúrgica sem retalho (técnica flapless). Essa técnica minimamente invasiva destaca-se por suas vantagens como menor sangramento durante a cirurgia, menor tempo cirúrgico e melhor pós-operatório para o paciente. Diante disto, o objetivo desta revisão de literatura é trazer informações sobre o comportamento dos tecidos Peri-implantares nas reabilitações implantossuportadas bem como comparar as técnicas cirúrgicas com e sem retalho. Realizou-se uma busca na base de dados Pubmed/Medline e foram incluídos na revisão estudos clínicos controlados que apresentaram relevância clínica publicados no período de 2008 a 2013. De acordo com os resultados, pode-se observar que a técnica sem retalho proporciona a manutenção da mucosa peri-implantar ao redor dos implantes. Entretanto, não existe diferença significativa quanto à perda óssea entre as técnicas estudadas. Além disso, ambas apresentaram previsibilidade nos resultados do tratamento com implantes. Pode-se concluir que não existem estudos clínicos controlados em longo prazo suficientes quanto à utilização da técnica flapless, entratanto, os resultados em curto prazo sugerem que é uma técnica previsível
In an attempt to preserve the soft and hard tissues, implant dentistry has opted for a flapless surgical approach (flapless technique). This minimally invasive technique is distinguished by its advantages such as less bleeding during surgery, shorter operative time and best postoperative for the patient. Hence, the purpose of this literature review is to provide information about the behavior of the peri-implant tissues in implant restorations and to compare surgical techniques with and without flaps. A search was conducted in the database PubMed/Medline and controlled clinical trials that showed clinical relevance published in the period 2008-2013 were included in this review. According to the results, it could be observed that the flapless surgical approach provides maintenance of the peri-implant mucosa around implants. However, no significant difference in bone loss between techniques was also observed. Besides that, both techniques, with or without flaps, showed predictability in the results of implant treatment. It can be concluded that there are not enough controlled clinical studies regarding the long term use of flapless technique. However, short term results suggest that it is a predictable technique