Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
Molecules ; 29(15)2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39125063

RESUMO

The advancement of traditional sample preparation techniques has brought about miniaturization systems designed to scale down conventional methods and advocate for environmentally friendly analytical approaches. Although often referred to as green analytical strategies, the effectiveness of these methods is intricately linked to the properties of the sorbent utilized. Moreover, to fully embrace implementing these methods, it is crucial to innovate and develop new sorbent or solid phases that enhance the adaptability of miniaturized techniques across various matrices and analytes. Graphene-based materials exhibit remarkable versatility and modification potential, making them ideal sorbents for miniaturized strategies due to their high surface area and functional groups. Their notable adsorption capability and alignment with green synthesis approaches, such as bio-based graphene materials, enable the use of less sorbent and the creation of biodegradable materials, enhancing their eco-friendly aspects towards green analytical practices. Therefore, this study provides an overview of different types of hybrid graphene-based materials as well as their applications in crucial miniaturized techniques, focusing on offline methodologies such as stir bar sorptive extraction (SBSE), microextraction by packed sorbent (MEPS), pipette-tip solid-phase extraction (PT-SPE), disposable pipette extraction (DPX), dispersive micro-solid-phase extraction (d-µ-SPE), and magnetic solid-phase extraction (MSPE).

2.
Biomed Chromatogr ; 38(8): e5896, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38797868

RESUMO

The aim of this study was to develop a high-performance liquid chromatography-tandem mass spectrometry method for the determination of 6-cyanodopamine, 6-nitrodopamine, 6-nitrodopa, 6-nitroadrenaline and 6-bromodopamine in human plasma samples. Strata-X 33 µm solid-phase extraction cartridges were used for the extraction of the catecholamines from human plasma samples. The catecholamines were separated in a 150 × 3 mm Shim-pack GIST C18-AQ column with 3 µm particle size, placed in an oven at 40°C and perfused with 82% mobile phase A (acetonitrile-H2O; 90:10, v/v) + 0.4% acetic acid and 18% mobile phase B (deionized H2O) + 0.2% formic acid at a flow rate of 340 µl/min in isocratic mode. The injected volume was 4 µl and the run lasted 4 min. The method was linear from 0.1 to 20 ng/ml and the lower limit of quantification was 0.1 ng/ml for all analytes. The method was applied to evaluate the plasma levels of catecholamines in plasma of patients with chronic kidney disease and allowed the detection for the first time of circulating levels of the novel catecholamines 6-bromodopamine and 6-cyanodopamine.


Assuntos
Limite de Detecção , Insuficiência Renal Crônica , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Modelos Lineares , Insuficiência Renal Crônica/sangue , Cromatografia Líquida de Alta Pressão/métodos , Masculino , Cromatografia Líquida/métodos , Extração em Fase Sólida/métodos , Dopamina/sangue , Dopamina/análogos & derivados , Catecolaminas/sangue , Pessoa de Meia-Idade , Espectrometria de Massa com Cromatografia Líquida
3.
Talanta ; 276: 126189, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38718645

RESUMO

A film composed of agarose and graphene (G) and magnetic nanoparticles (G-MNPs) is proposed as a sorbent for the extraction and determination of medroxyprogesterone (MED), levonorgestrel (LEV), norethisterone (NOR) and progesterone (PRO) in natural water samples. Both the preparation of the film and the extraction procedure were optimized. The optimal extraction parameters were as follows: isopropyl alcohol as activation solvent, sample pH value of 3.0, extraction time of 30 min, 1.00 mL of acetonitrile as eluent, elution time of 5 min and sample volume of 100.00 mL. HPLC with photodiode array detector was used for the separation and determination. The method presented a linear range between 2.50 and 75.0 µg L-1 for all analytes, and the LODs were between 1.40 and 1.80 µg L-1. The method was applied to natural water samples, obtaining satisfactory recovery values (75-111 %). In conclusion, for the immobilization of the G-MNPs, agarose was used, which is a non-toxic, renewable and biodegradable material. The G-MNPs-agarose film was reused up to 70 times, without losing its extraction capacity significantly and presenting excellent sorbent properties, which allow the extraction and preconcentration of the progestogens under study.


Assuntos
Progestinas , Poluentes Químicos da Água , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Poluentes Químicos da Água/química , Progestinas/isolamento & purificação , Progestinas/análise , Progestinas/química , Adsorção , Nanopartículas de Magnetita/química , Extração em Fase Sólida/métodos , Sefarose/química , Cromatografia Líquida de Alta Pressão
4.
J Chromatogr A ; 1720: 464809, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38490141

RESUMO

An ultrafast, efficient, and eco-friendly method combining magnetic solid phase extraction and capillary electrophoresis with diode array detection have been developed to determine ractopamine residues in food samples. A restricted access material based on magnetic and mesoporous molecularly imprinted polymer has been properly synthesized and characterized, demonstrating excellent selectivity and high adsorbent capacity. Short-end injection capillary electrophoresis method was optimized: 75 mM triethylamine pH 7 as BGE, -20 kV, 50 mbar by hydrodynamic injection during 8 s, and capillary temperature at 25 °C; reaching ultrafast ractopamine analysis (∼0.6 min) with good peak asymmetry, and free from interfering and/or baseline noise. After sample preparation optimization, the conditions were: 1000 µL of sample at pH 6, 20 mg of adsorbent, stirring time of 120 s, 250 µL of ultrapure water as washing solvent, 1000 µL of methanol: acetic acid (7: 3, v/v) as eluent, and the adsorbent can be reused four times. In these conditions, the analytical method showed recoveries around to 100 %, linearity ranged from 9.74 to 974.0 µg kg-1, correlation coefficient (r) ≥ 0,99 in addition to adequate precision, accuracy, and robustness. After proper validation, the method was successfully applied in the analysis ractopamine residues in bovine milk and bovine and porcine muscle.


Assuntos
Impressão Molecular , Polímeros Molecularmente Impressos , Fenetilaminas , Animais , Suínos , Extração em Fase Sólida/métodos , Eletroforese Capilar/métodos , Fenômenos Magnéticos , Impressão Molecular/métodos , Cromatografia Líquida de Alta Pressão/métodos
5.
Methods Mol Biol ; 2758: 319-329, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38549022

RESUMO

Snake venom peptidomes are known to be a large source of molecules with different pharmacological properties. The complexity and variability of snake venoms, the presence of proteinases, and the lack of complete species-specific genome sequences make snake venom peptidome profiling a challenging task that requires especial technical strategies for sample processing and mass spectrometric analysis. Here, we describe a method for assessing the content of snake venom peptides and highlight the importance of sampling procedures, as they substantially influence the peptidomic complexity of snake venoms.


Assuntos
Peptídeos , Venenos de Serpentes , Venenos de Serpentes/química , Peptídeos/química , Espectrometria de Massas , Genoma , Peptídeo Hidrolases
6.
Food Chem ; 440: 138238, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38142556

RESUMO

In the present study, a magnetic ion-imprinted polymer based on n-allylthiourea in the presence of 1-(2-pyridylazo)-2-naphthol (MIIP-PAN) was synthesized, characterized, and applied in the preconcentration of nickel ions by dispersive magnetic solid phase extraction (DMSPE) with FAAS detection. For comparison, non-imprinted polymer (MNIP-PAN) and imprinted polymer without PAN were synthesized. The characterization of the polymers was performed by FT-IR, DRX, TEM, TGA, VSM, and BET. Selectivity studies were performed comparing the competitive adsorption of Ni2+ with other cations on MIIP-PAN and MNIP-PAN, achieving higher relative selectivity coefficients for MIIP-PAN than for MNIP-PAN and NIP. Under optimized conditions, the method provided a preconcentration factor of 76.70, detection limit of 0.25 µg/L and intra-day (2.06 - 2.33 %) and inter-day (1.82 - 4.90 %) precision. The developed method was applied to samples of water, teas, and chocolate powder, and its precision was evaluated through tests of recovery and analysis of certified materials.


Assuntos
Impressão Molecular , Níquel , Propanolaminas , Níquel/análise , Água , Espectroscopia de Infravermelho com Transformada de Fourier , Polímeros , Adsorção , Fenômenos Magnéticos , Extração em Fase Sólida/métodos
7.
Artigo em Inglês | MEDLINE | ID: mdl-37535992

RESUMO

Through density functional theory calculations was studied theoretically the formation process of a magnetic and mesoporous molecularly imprinted polymer for ractopamine (RAC), evaluating the molecular electrostatic potential map, functional monomers, functional monomer / template stoichiometry and crosslink agents. The results revealed that the best conditions for the synthesis were established with acrylic acid as functional monomer in a 1: 4 stoichiometry using acetonitrile as the solvent and ethylene glycol dimethacrylate as crosslink agent. It was observed that nine hydrogen bonds established between the RAC and acrylic acid play a key role on the pre-polymerization complex. In addition, three analytical methods using HPLC, UHPLC and CE instruments were optimized for rapid analysis. The adsorbent was experimentally synthesized considering the best conditions found at the molecular level and characterized by FTIR, DRX, TGA, SEM, TEM, surface analysis, and wettability. After that, the synthesized material was used in magnetic solid phase extraction combined with capillary electrophoresis in a preliminary RAC recovery study from milk samples. Finally, greenness metric with a score of 0.55 have been obtained for the sample preparation procedure using the online AGREEprep metric.


Assuntos
Impressão Molecular , Polímeros Molecularmente Impressos , Impressão Molecular/métodos , Adsorção , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Fenômenos Magnéticos
8.
Molecules ; 28(13)2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37446610

RESUMO

Currently, polypropylene (PP) is highlighted using sorbitol-based clarifying agents since these agents are high quality, low cost, and work as a barrier against moisture, which makes PP ideal for packaging food, beverages, and medical products, among others. The use of analytical methods capable of recovering these additives in wastewater streams and then reusing them in the PP clarification stage represents an innovative methodology that makes a substantial contribution to the circular economy of the PP production industry. In this study, a method of extraction and recovery of the Millad NX 8000 was developed. The additive was recovered using GC-MS and extracted with an activated carbon column plus glass fiber, using an injection molded sample, obtaining a recovery rate greater than 96%. TGA, DSC, and FTIR were used to evaluate the recovered additive's glass transitions and purity. The thermal degradation of the recovered additive was found to be between 340 and 420 °C, with a melting temperature of 246 °C, adopting the same behavior as the pure additive. In FTIR, the characteristic absorption peak of Millad NX 8000 was observed at 1073 cm-1, which indicates the purity of the extracted compound. Therefore, this work develops a new additive recovery methodology with high purity to regulate the crystallization behavior and of PP.


Assuntos
Sorbitol , Águas Residuárias , Polipropilenos/química , Polímeros , Embalagem de Produtos
9.
Anal Bioanal Chem ; 415(16): 3073-3091, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37085739

RESUMO

Toxic elements represent a serious threat to the environment and cause harmful effects on different environmental components, even at trace levels. These toxic elements are often difficult to detect through the typical instrumentation of an analytical laboratory because they are found at very low concentrations in matrices such as food and water. Therefore, preconcentration plays a fundamental role since it allows the effects of the matrix to be minimized, thus reaching lower detection limits and greater sensitivity of detection techniques. In recent years, solid-phase extraction has been successfully used for the preconcentration of metals as an environmentally friendly technique due to the fact that it eliminates or minimizes the use of reagents and solvents and offers reduced analysis times and low generation of waste in the laboratory. Hybrid biomaterials are low-cost, eco-friendly, and useful as efficient solid phases for the preconcentration of elements. In this review, recent investigations based on the use of hybrid biomaterials for the preconcentration and determination of toxic metals are presented and discussed, given special attention to bionanomaterials. A brief description of hybrid biomaterials often used for analytical purposes, as well as analytical techniques mostly used to characterize the hybrid biomaterials, is explained. Finally, the future prospects that encourage the search for new hybrid biomaterials are commented upon.


Assuntos
Metaloides , Metais/toxicidade , Metais/análise , Água , Solventes/análise , Extração em Fase Sólida/métodos
10.
Anal Chim Acta ; 1251: 340709, 2023 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-36925273

RESUMO

A procedure of direct magnetic sorbent sampling in flame atomic absorption spectrometry (DMSS-FAAS) was developed in this work. Metal-loaded magnetic sorbents were directly inserted in the flame of the FAAS for direct metal desorption/atomization. Magnetic graphene oxide aerogel (M-GOA) particles were synthesized, characterized, and used as a proof-of-concept in the magnetic dispersive solid phase extraction of Pb2+ ions from water samples. M-GOA was selected because is a light and porous sorbent, with high adsorption capacity, that is quickly burned by the flame. Magnetic particles were directly inserted in the flame by using a metallic magnetic probe, thereby avoiding the need for a chemical elution step. As all the extracted Pb2+ ions arrive to the flame without passing through the nebulization system, a drastic increase in the analytical signal was achieved. The improvement in the sensitivity of the proposed method (DMSS-FAAS) for Pb2+ determination was at least 40 times higher than the conventional procedure in which the Pb2+ is extracted, eluted, and analyzed by conventional flame atomic absorption spectrometry (FAAS) via the nebulization system. The analytical curve was linear from 5.0 to 180.0 µg L-1 and the limit of detection was found to be 1.30 µg L-1. Background measurements were insignificant, and the atomic absorption peaks were narrow and reproducible. Precision assessed as a percentage of the relative standard deviation %RSD was found to be 17.4, 7.1, and 7.8% for 10, 70, and 180 µg L-1 levels, respectively. The method showed satisfactory results even in the presence of other ions (Al3+, Cr3+, Co2+, Cu2+, Fe3+, Mn2+, Ba2+, Mg2+, and Li+). The performance of the new system was also evaluated for Cd2+ ions, as well as by using other magnetic particles available in our lab: magnetic carbon nanotubes (M-CNTs), magnetic restricted access carbon nanotubes (M-RACNT), magnetic poly (methacrylic acid-co-ethylene glycol dimethacrylate) (M-PMA), magnetic nanoparticles coated with orange powder peel (M-OPP), and magnetic nanoparticles covered with SiO2 (M - SiO2). Analytical signals increased for both analytes in all sorbents (increases of about 4-37 times), attesting the high potential and applicability of the proposed method. Simplicity, high analytical frequency, high detectability and reproducibility, low cost, and possibility of being totally mechanized are the most relevant advantages.

11.
Metallomics ; 15(4)2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-36914218

RESUMO

This work aims to evaluate the size and lability of Cu and Zn bound to proteins in the cytosol of fish liver of Oreochromis niloticus by employing solid-phase extraction (SPE), diffusive gradients in thin films (DGT), and ultrafiltration (UF). SPE was carried out using Chelex-100. DGT containing Chelex-100 as binding agent was employed. Analyte concentrations were determined by ICP-MS. Total Cu and Zn concentrations in cytosol (1 g of fish liver in 5 ml of Tris-HCl) ranged from 39.6 to 44.3 ng ml-1 and 1498 to 2106 ng ml-1, respectively. Data from UF (10-30 kDa) suggested that Cu and Zn in cytosol were associated with ∼70% and 95%, respectively, with high-molecular-weight proteins. Cu-metallothionein was not selectively detected (although 28% of Cu was associated with low-molecular-weight proteins). However, information about the specific proteins in the cytosol will require coupling UF with organic mass spectrometry. Data from SPE showed the presence of labile Cu species of ∼17%, while the fraction of labile Zn species was >55%. However, data from DGT suggested a fraction of labile Cu species only of 7% and a labile Zn fraction of 5%. This data, as compared with previous data from literature, suggests that the DGT technique gave a more plausible estimation of the labile pool of Zn and Cu in cytosol. The combination of results from UF and DGT is capable of contributing to the knowledge about the labile and low-molecular pool of Cu and Zn.


Assuntos
Ciclídeos , Poluentes Químicos da Água , Animais , Ultrafiltração/métodos , Citosol , Zinco/análise , Fígado/química , Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise
12.
Food Chem ; 412: 135461, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-36731230

RESUMO

An alternative analytical method was developed for the quantification of inorganic arsenic (iAs) in rice by ICP OES. Iron nanoparticles modified with an organophosphorus compound were used as the solid phase for MSPE of iAs from the plant matrix. The MSPE procedure was performed using 4 mL of a buffer solution with pH 4.0, 20 mg of the nanomaterial, and a 15-min extraction time. The total As (tAs) by ICP OES was also quantified using the same MSPE procedure after solubilization of the samples by a block digester. The accuracy of tAs and iAs quantification was verified using CRM NIST 1568b (97 % and 101 % recovery, respectively). The precision (RSD < 15 %) and LOD and LOQ (1.08 and 3.70 µg kg-1, respectively) of the proposed method were satisfactory. The rice samples had tAs contents between 0.090 and 0.295 mg kg-1 and iAs mass fractions between 0.055 and 0.109 mg kg-1.


Assuntos
Arsênio , Arsenicais , Oryza , Arsênio/análise , Oryza/química , Análise Espectral , Extração em Fase Sólida/métodos , Fenômenos Magnéticos
13.
Food Chem ; 413: 135676, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-36804744

RESUMO

The direct magnetic sorbent sampling flame atomic absorption spectrometry (DMSS-FAAS), recently proposed by our research group, was applied to determine the lead in soy-based juice, whole grape juice, reconstituted grape juice, and orange nectar samples. A dispersive solid phase extraction (d-SPE) of lead was carried out using a magnetic orange peel powder, developed and optimized by Gupta et al (2012), that was inserted into flame by FAAS with a magnetic probe. The limits of quantification (<4.6 µg L-1) were smaller than maximum residue limits established in Brazil. Good precisions and accuracies were obtained. DMSS-FAAS presented a sensitivity at least 14 times greater than the d-SPE followed by conventional FAAS analysis, wherein the analytes were extracted and desorbed, and the eluate was introduced in FAAS via nebulization system. Lead was easily quantified in juice samples at very low concentrations, with satisfactory figures of merit, and without the need of a mineralization step.


Assuntos
Magnetismo , Extração em Fase Sólida , Espectrofotometria Atômica/métodos , Extração em Fase Sólida/métodos , Alimentos , Fenômenos Magnéticos
14.
Environ Sci Pollut Res Int ; 30(14): 41014-41027, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36626055

RESUMO

In this work, the photolysis of the antibiotic norfloxacin (NOR) and the formation of its photodegradation products were studied using UV and solar radiation. Their extraction was also assessed in Milli-Q water and secondary effluents from a wastewater treatment plant. The photolysis of NOR was chromatographically monitored. The structure of each degradation product is related to the reaction of NOR with reactive oxygen species (ROS), as confirmed using radical quenchers and mass spectrometry. Additionally, the feasibility of extracting NOR and its degradation products was assessed using a commercial solid phase extraction system. Photolysis results showed the formation of five degradation products, generated under exposure to both types of radiation. The decays in NOR concentrations for the solar and UV treatments were adjusted to pseudo first-order kinetics with apparent constant values of ksolar = 1.19 × 10-3 s-1 and kUV = 3.84 × 10-5 s-1. Furthermore, the superoxide radical was the main participant species in the formation of the degradation products P3, P4, and P5. Species P1 and P2 do not need this radical for their formation. The presence of NOR in water opens the possibility of its photolysis by solar radiation. This work contributes to the understanding of the mechanisms that mediate its photodegradation, in addition to studying potential options for its determination and its photodegradation products in the sample treatment.


Assuntos
Antibacterianos , Poluentes Químicos da Água , Humanos , Antibacterianos/química , Norfloxacino/análise , Fotólise , Luz Solar , Cinética , Água/química , Poluentes Químicos da Água/análise , Raios Ultravioleta
15.
Environ Technol ; 44(19): 2900-2912, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35220916

RESUMO

With a worldwide ever increasing demand for metals, particularly for the manufacture of electronics and batteries, there is not only a concurrent need to recover these materials from their subsequent waste streams but also a need to make advancements to do this via development of more efficient and eco-friendly processes for metal recovery; solid-phase extraction can be considered a promising alternative to conventional processes. This work studied the production of novel nanofibers modified with Cyanex 272 and their application in the recovery of cobalt present in aqueous solution The nanofibers produced by forcespinning were characterized by SEM, FT-IR and TGA and the extraction of cobalt was evaluated by variation of the pH, solid:liquid (S:L) ratio, extraction time and Cyanex 272 content in the nanofibers. The best extraction efficiency was 99.96%, achieved under the following conditions: pH 8; (S:L) ratio of 1:200; 25% of Cyanex 272; Extraction time of 60 min. The maximum extraction capacity obtained was 15.46 mg Co/g of nanofiber and 70.15 mg Co/g of extractor. In successive reuse cycles, the results demonstrated that the extraction efficiency was maintained at over 85%. The findings showed that Nylon 6/Cyanex 272 nanofibers are a new robust and promising material for the recovery of heavy metals from aqueous solution, confirming that nanofibers have an efficiency similar to conventional liquid-liquid extraction, without the disadvantage of volatile organic compounds emissions generated by the use of organic diluents.


Assuntos
Cobalto , Nanofibras , Cobalto/química , Espectroscopia de Infravermelho com Transformada de Fourier , Metais , Água
16.
Crit Rev Food Sci Nutr ; 63(24): 6820-6839, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35170386

RESUMO

Coffee is one of the most consumed beverages in the world. Coffee provides to the consumer special sensorial characteristics, can help to prevent diseases, improves physical performance and increases focus. In contrast, coffee consumption supplies a significant source of substances with carcinogenic and genotoxic potential such as furan, hydroxymethylfurfural (HMF), furfural (F), and acrylamide (AA). The present review addresses the issues around the presence of such toxic substances formed in Maillard reaction (MR) during thermal treatments in food processing, from chemical and, toxicological perspectives, occurrences in coffee and other foods processed by heating. In addition, current strategies advantages and disadvantages are presented along with application of molecular imprinting technology (MIT) and poly (ionic liquid) s (PIL) as an alternative to reduce the furan, HMF, F and AA content in coffee and other foods.


Assuntos
Líquidos Iônicos , Impressão Molecular , Café/química , Líquidos Iônicos/química , Acrilamida/química , Furanos
17.
Nanomaterials (Basel) ; 14(1)2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38202528

RESUMO

This study investigates electrospun fibers of metal-organic frameworks (MOFs), particularly CuBTC and ZIF-8, in polyacrylonitrile (PAN) for the solid-phase extraction (SPE) of Tamoxifen (TAM) and its metabolites (NDTAM, ENDO, and 4OHT) from human blood plasma. The focus is on the isolation, pre-concentration, and extraction of the analytes, aiming to provide a more accessible and affordable breast cancer patient-monitoring technology. The unique physicochemical properties of MOFs, such as high porosity and surface area, combined with PAN's stability and low density, are leveraged to improve SPE efficiency. The study meticulously examines the interactions of these MOFs with the analytes under various conditions, including elution solvents and protein precipitators. Results reveal that ZIF-8/PAN composites outperform CuBTC/PAN and PAN alone, especially when methanol is used as the protein precipitator. This superior performance is attributed to the physicochemical compatibility between the analytes' properties, like solubility and polarity, and the MOFs' structural features, including pore flexibility, active site availability, surface polarity, and surface area. The findings underscore MOFs' potential in SPE applications and provide valuable insights into the selectivity and sensitivity of different MOFs towards specific analytes, advancing more efficient targeted extraction methods in biomedical analysis.

18.
Molecules ; 27(23)2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36500214

RESUMO

Fluoroquinolones (FQs) are broad-spectrum antibiotics widely used to treat animal and human infections. The use of FQs in these activities has increased the presence of antibiotics in wastewater and food, triggering antimicrobial resistance, which has severe consequences for human health. The detection of antibiotics residues in water and food samples has attracted much attention. Herein, we report the development of a highly sensitive online solid-phase extraction methodology based on a selective molecularly imprinted polymer (MIP) and fluorescent detection (HPLC-FLD) for the determination of FQs in water at low ng L−1 level concentration. Under the optimal conditions, good linearity was obtained ranging from 0.7 to 666 ng L−1 for 7 FQs, achieving limits of detection (LOD) in the low ng L−1 level and excellent precision. Recoveries ranged between 54 and 118% (RSD < 17%) for all the FQs tested. The method was applied to determining FQs in river water. These results demonstrated that the developed method is highly sensitive and selective.


Assuntos
Fluoroquinolonas , Impressão Molecular , Animais , Humanos , Fluoroquinolonas/química , Polímeros Molecularmente Impressos , Impressão Molecular/métodos , Polímeros/química , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Antibacterianos/análise , Água/química
19.
J Chromatogr A ; 1685: 463596, 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36323105

RESUMO

The QuEChERSER mega-method has recently been introduced to quantify and identify a wide range of chemical residues (pesticides, veterinary drugs, environmental contaminants, among others) in nearly all types of foods. The approach calls for taking a small amount of the initial extract to cover analytes amenable to liquid chromatography, and the remainder is salted out for analysis by gas chromatography (GC), both with mass spectrometry (MS) based detection. In the case of GC-MS(/MS), the extract undergoes automated robotic mini-cartridge solid-phase extraction (SPE) cleanup in a technique known as µSPE or instrument-top sample preparation (ITSP). In 2022, a septumless mini-cartridge for µSPE was introduced to improve upon the ITSP design. The new design houses a bed of 20 mg anhydrous MgSO4, 12 mg each of C18 and primary secondary amine sorbents, and 1 mg of graphitized carbon black, the latter substituting for CarbonX used in the ITSP product. The septumless µSPE mini-cartridge employs a different gripping mechanism with the syringe needle that allows leak-free operation at higher flow rates (e.g. 10 µL/s), whereas the ITSP design is limited to 2 µL/s. Based on cleanup and analyte elution profiles, the extract load volume and flow rate was increased in µSPE for QuEChERSER from 300 µL at 2 µL/s to 500 µL at 5 µL/s, which improved accuracy of results, sped the cleanup step, and obviated the need for micro-vial inserts in the receiving vials. The new design also reduced both the amount and consistency of dead (void) volumes in the mini-cartridges from 83 ± 14 µL to 52 ± 7 µL for 200-600 µL load volumes. Normalization of peak areas to internal standards led to recoveries between 80 and 120% with typical RSDs <5% in low-pressure GC-MS/MS of 227-242 out of 252 pesticides, polychlorinated biphenyls, polybrominated diphenyl ethers, and polycyclic aromatic hydrocarbons in hemp powder, spinach, whole milk, egg, avocado, and lamb meat.


Assuntos
Resíduos de Praguicidas , Praguicidas , Cromatografia Gasosa-Espectrometria de Massas/métodos , Resíduos de Praguicidas/análise , Praguicidas/análise , Extratos Vegetais/análise , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos
20.
Food Res Int ; 160: 111711, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36076407

RESUMO

This study aimed to extract anthocyanins from dried and semi-defatted açaí pulp using green technologies based on the coupling of pressurized liquid extraction (PLE) with in-line purification through solid-phase extraction (SPE) and on-line analysis by high-performance liquid chromatography (HPLC). Critical parameters that affect the extraction efficiency and purification were investigated and optimized by response surface methodology (RSM). PLE was performed with acidified water at different pH (2.0, 4.5, and 7.0) and temperatures (40, 80, and 120 °C) at 15 MPa, 2 mL/min, and solvent-to-feed mass ratio equal to 40. SPE was optimized in a column packed with the adsorbent PoraPak™ Rxn. Different ethanol concentrations (50, 75, and 100 %) and temperatures (30, 40, and 50 °C) were evaluated for the anthocyanin's elution. The optimal conditions of the two experimental designs were determined by the RSM, firstly for PLE: 71 °C and pH 2; then using this PLE condition, the optimization of the SPE was obtained: 30 °C and 50 % ethanol. The developed PLE method provided similar anthocyanin yield to other techniques, and the coupling with SPE in-line produced an extract 5-fold more concentrated than PLE alone. Therefore, the system (PLE-SPE × HPLC-PDA) proved to be a powerful tool for monitoring the extraction process in real-time.


Assuntos
Antocianinas , Euterpe , Dióxido de Carbono , Cromatografia Líquida de Alta Pressão , Etanol , Extração em Fase Sólida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA