RESUMO
Filler content in dental composites is credited for affecting its physical and mechanical properties. This study evaluated the correlation between the filler percentage and strength, modulus, shrinkage stress, depth of cure, translucency and radiopacity of commercially available high- and low-viscosity dental composites. Filler weight percentage (wt%) was determined through the burned ash technique (800 °C for 15 min). Three-point bend flexural strength and modulus were measured according to ISO 4049 with 2 mm × 2 mm × 25 mm bars. Shrinkage stress was evaluated using a universal testing machine in which composite was polymerized through two transparent acrylic rods 2 mm apart. Shrinkage was measured from the maximum force following 500 s. The translucency parameter (TP) was measured as the difference in color (ΔE00) of 1 mm thick specimens against white and black tiles. The depth of cure was measured according to ISO 4049 in a cylindrical metal mold (4 mm diameter) with a 10 s cure. Radiopacity was measured by taking a digital X-ray (70 kVp for 0.32 s at 400 mm distance) of 1 mm thick specimens and comparing the radiopacity to an aluminum step wedge using image analysis software. The correlation between the filler wt% and properties was measured by Pearson's correlation coefficient using SPSS. There was a positive linear correlation between the filler wt% and modulus (r = 0.78, p < 0.01), flexural strength (r = 0.46, p < 0.01) and radiopacity (r = 0.36, p < 0.01) and negative correlation with translucency (r = -0.29, p < 0.01). Filler wt% best predicts the modulus and strength and, to a lesser extent, the radiopacity and translucency. All but two of the high- and low-viscosity composites from the same manufacturer had statistically equivalent strengths as each other; however, the high-viscosity materials almost always had a statistically higher modulus. For two of the flowable composites measured from the same manufacturer (3M and Dentsply), there was a lower shrinkage stress in the bulk-fill version of the material but not for the other two manufacturers (Ivoclar and Tokuyama). All flowable bulk-fill composites achieved a deeper depth of cure than the flowable composite from the same manufacturer other than Omnichroma Flow Bulk.
RESUMO
The present study examined different concentrations of the butylated hydroxytoluene (BHT) inhibitor on the kinetics of conversion, polymerization shrinkage stress, and other correlated physicochemical properties of experimental resin composites (ERC). A model composite was formulated with 75 wt% filler containing 0.5 wt% camphorquinone and 1 wt% amine with BHT concentrations of 0.01 wt% (BHT-0.01); 0.1 wt% (BHT-0.1); 0.25 wt% (BHT-0.25); 0.5 wt% (BHT-0.5); 1 wt% (BHT-1), and control (no BHT). They were tested on polymerization shrinkage stress (PSS; n = 5), degree of conversion (DC; n = 3), maximum polymerization rate (RpMAX; n = 5), water sorption (Wsp; n = 0), and solubility (Wsl; n = 10), flexural strength (FS; n = 10), flexural modulus (FM; n = 10), Knoop microhardness (KH; n = 10), and microhardness reduction (HR; n = 10). Data concerning these tests were submitted to one-way ANOVA and Tukey's test (α = 0.05; ß = 0.2). BHT-0.25, BHT-0.5, and BHT-1 showed a gradually significant decrease in PSS (p = 0.037); however, BHT-1 demonstrated a decrease in the physicochemical properties tested. Thus, within the limitations of this study, it was possible to conclude that BHT concentrations between 0.25 and 0.5 wt% are optimal for reducing shrinkage stress without affecting other physicochemical properties of ERCs.
Assuntos
Hidroxitolueno Butilado , Resinas Compostas , Teste de Materiais , Polimerização , Estresse Mecânico , Hidroxitolueno Butilado/química , Resinas Compostas/química , Fenômenos Químicos , Solubilidade , Água/química , DurezaRESUMO
Abstract This study aimed to evaluate the effect of an elastomeric urethane monomer (Exothane-24) in different concentrations on physicochemical properties, gap formation, and polymerization shrinkage stress of experimental resin composites. All experimental composites were prepared with 50 wt.% of Bis-GMA and 50 wt.% of TEGDMA, to which 0 wt.% (control), 10 wt.%, 20 wt.%, 30 wt.%, and 40 wt.% of Exothane-24 were added. Filler particles (65 wt.%) were then added to these resin matrixes. Ultimate tensile strength (UTS: n = 10), flexural strength (FS: n = 10), flexural modulus (FM: n = 10), hardness (H: n = 10), hardness reduction (HR: n = 10), degree of conversion (DC: n = 5), gap width (GW: n = 10), and polymerization shrinkage stress in Class I (SS-I: n = 10) and Class II (SS-II: n = 10) simulated configuration. All test data were analyzed using one-way ANOVA and Tukey's test (α = 0.05; β= 0.2). Exothane-24 in all concentrations decreased the H, HR, DC, GW, SS-I, and SS-II (p < 0.05) without affecting the UTS, and FS (p > 0.05). Reduction in FM was observed only in the Exothane 40% and 30% groups compared to the control (p < 0.05). Exothane-24 at concentrations 20% and 30% seems suitable since it reduced GW and polymerization SS without affecting the properties of the composite resins tested, except for H.
Resumo Este estudo teve como objetivo avaliar o efeito de um monômero elastomérico de uretano (Exothane-24) em diferentes concentrações em propriedades físico-químicas, formação de fenda e tensão de contração de polimerização de resinas compostas experimentais. Todos os compósitos experimentais foram preparados com 50% em peso de Bis-GMA e 50% em peso de TEGDMA, nos quais 0% (controle), 10%, 20%, 30% e 40% em peso de Exothane-24 foram adicionados. Partículas de carga (65% em peso) foram então adicionadas as matrizes resinosas. Resistência coesiva (RC: n = 10), resistência à flexão (RF: n = 10), módulo de flexão (MF: n = 10), dureza (D: n = 10), redução de dureza (RD: n = 10), grau de conversão (GC: n = 5), largura de fenda (LF: n = 10) e tensão de contração de polimerização em simulações de cavidades Classe I (TC-I: n = 10) e Classe II (TC-II: n = 10). Todos os dados do teste foram analisados usando one-way ANOVA e teste de Tukey (α = 0,05; β = 0,2). O Exothane-24 em todas as concentrações diminuiu a D, RD, GC, LF, TC-I e TC-II (p < 0,05) sem afetar o RC e RF (p > 0,05). A redução da MF foi observada apenas nos grupos Exothane 40% e 30% em relação ao controle (p < 0,05). O Exothane-24 nas concentrações de 20% e 30% pareceu ser adequado, pois reduziu LF e TC de polimerização sem afetar as propriedades das resinas compostas testadas, exceto para D.
RESUMO
OBJECTIVE: Evaluate the effect of different restorative filling techniques on the residual shrinkage stress (ShrS), cuspal strain (CS), depth of cure (DC), and enamel crack formation (Ec) in molars with MOD restorations. METHODS: Post-gel shrinkage, elastic modulus, compressive and diametral tensile strength of the Filtek One Bulk Fill composite were calculated. Sixty molars with MOD preparations were restored using four filling techniques: Bulk; Horizontal; Oblique; Natural enamel and dentin substitution (NEDS) technique. CS was measured using a strain gauge (n = 10). The DC (n = 5) was measured using Knoop hardness. Shrinkage stress/strain was analyzed using 3D finite element analysis. The Ec analysis was carried out by transillumination. Two-way ANOVA with repeated measures and Tukey's HSD test (α = 0.05) was performed for the CS data. Two-Way ANOVA and Tukey's HSD test was performed for the DC data (α = 0.05). RESULTS: CS was higher at the lingual cusp for the horizontal and NEDS technique. No statistical difference was found between the buccal and lingual CS values for the Bulk (p = 0.367) or Oblique techniques (p = 0.192). CS values were lower for the Bulk. More enamel cracks were found for the Bulk. DC was lower at 4 mm regardless the filling technique. The Horizontal showed the highest ShrS values. The Bulk generated the lower ShrS values. SIGNIFICANCE: A Bulk technique caused the lowest shrinkage stress/strain. An Oblique technique yielded the best balance between stress, strain and crack formation. NEDS technique is a good alternative to decrease the number of increments while maintaining the stress levels nearby the Oblique technique.
Assuntos
Resinas Compostas , Restauração Dentária Permanente , Esmalte Dentário , Restauração Dentária Permanente/métodos , Análise do Estresse Dentário , Teste de Materiais , Dente Molar , PolimerizaçãoRESUMO
Contraction due to polymerization of dental resin can cause failure on the adhesive interfaces, can lead to problems such as the appearance of gaps in the interfaces, postoperative sensitivity, pulp damage and the return of the caries. The objective of this work is the study of stresses on the dental adhesive that are generated by the process shrinkage of resin associated with biting forces. A laboratory experiment measured the strains and temperature inside the FiltekTM Bulk Fill Flow resin during the process of polymerization using Fiber Bragg Grating sensors in an ex vivo tooth. From tomographic images a three-dimensional geometric model of the tooth was reconstructed. A pre-tension was calibrated to simulate the residual contraction on the resin 3 D model. Finally, an Finite Element Method analysis was performed to access the adhesive stresses at the interface enamel/dentin with the adhesive, considering as loading the residual polymerization contraction of the dental resin and also biting loads. The model was able to represented the strain obtained in the laboratory experiment. The results of the stress analysis shows that the outer regions of adhesive are more prone to failure, as veried by dental surgeons in clinical practice.
Assuntos
Resinas Compostas/química , Análise de Elementos Finitos , Óptica e Fotônica/métodos , Adulto , Fenômenos Biomecânicos , Força de Mordida , Calibragem , Colagem Dentária , Análise do Estresse Dentário , Humanos , Imageamento Tridimensional , Teste de Materiais , Polimerização , Pressão , Temperatura , Adulto JovemRESUMO
Abstract This study aimed to evaluate the polymerization properties of bulk-fill materials (low and high-viscosity) by using high-intensity continuous light and intermittent photo-activation in terms of polymerization shrinkage stress and degree of conversion (DC). The following Bulk-fill and Conventional nanofilled resin composites were evaluated: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) and Filtek Bulk Fill Posterior (3M/ESPE). A LED device (DB 685, Dabi Atlante) was used for both protocols: continuous uniform and intermittent photo-activation (light-on and light-off cycles) with identical radiant exposure (14 J/cm2). The polymerization shrinkage stress (n=6) was evaluated by inserting a single increment of 12 mm3 between two stainless steel plates (6×2 mm) adapted to a Universal Testing Machine (UTM), at different times. Measurements were recorded after photo-activation. The degree of conversion was evaluated by Fourier transformed infrared spectroscope (FTIR) with an attenuated total reflectance (ATR) accessory (n=5). Data were analyzed by three-way ANOVA and Tukey's HSD (α=0.05) tests. Bulk Fill Posterior presented higher shrinkage stress values when photo-activated with the intermittent technique (p<0.05). The intermittent photo-activation increased the degree of conversion for the low-viscosity bulk-fills (p<0.05). Therefore, the use of modulated photo-activation (intermittent) must be indicated with caution since its use can influence the shrinkage stress and degree of conversion of composites, which varies according to the resin formulations.
Resumo O presente estudo teve como objetivo avaliar as propriedades de polimerização de materiais bulk-fill (baixa e alta viscosidade) utilizando luz contínua de alta intensidade e fotoativação intermitente em relação ao estresse de contração de polimerização e grau de conversão (DC). As seguintes resinas compostas Bulk-fill e nanohíbridas convencionais foram avaliadas: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) e Filtek Bulk Fill Posterior (3M/ESPE). Um dispositivo de LED (DB 685, Dabi Atlante) foi utilizado nos dois protocolos: fotoativação contínua e intermitente contínua (ciclos de liga e desliga) com exposição idêntica (14 J/cm2). A tensão de contração de polimerização (n=6) foi avaliada através da inserção de um incremento único de 12 mm3 entre duas placas de aço inoxidável (6×2 mm) adaptadas a uma Máquina de Ensaio Universal (UTM), em tempos diferentes. As medições foram registradas após a fotoativação. O grau de conversão foi avaliado por FTIR-ATR (n=5). Os dados foram analisados pelos testes ANOVA a três fatores e teste de Tukey (α=0,05). A resina Bulk Fill Posterior apresentou maiores valores de tensão de contração quando fotoativadas com a técnica intermitente (p<0,05). A fotoativação intermitente aumentou o grau de conversão nas resinas bulk-fill de baixa viscosidade (p<0,05). Portanto, o uso de fotoativação modulada (intermitente) deve ser indicado com cautela, uma vez que seu uso pode influenciar a tensão de contração e o grau de conversão dos compósitos, o que varia de acordo com as formulações da resina.
Assuntos
Teste de Materiais , Resinas Compostas , Viscosidade , PolimerizaçãoRESUMO
PURPOSE: A systematic review was conducted to determine whether there were composition strategies available to reduce and control polymerization shrinkage stress development in resin-based restorative dental materials. DATA SOURCES: This report was reported in accordance with the PRISMA Statement. Two reviewers performed a literature search up to December 2016, without restriction of the year of publication, in seven databases: PubMed, Web of Science, Scopus, SciELO, LILACS, IBECS, and BBO. STUDY SELECTION: Only laboratory studies that evaluated polymerization shrinkage stress by direct testing were included. Pilot studies, reviews and in vitro studies that evaluated polymerization shrinkage stress by indirect methods (e.g., microleakage or cuspal deflection measurements), finite elemental analysis, or theoretical and mathematical models were excluded. Of the 6113 eligible articles, 62 studies were included in the qualitative analysis, and the meta-analysis was performed with 58 studies. The composition strategy was subdivided according to the modified part of the material: filler phase, coupling agent, or resin matrix. A global comparison was performed with random-effects models (αâ¯=â¯0.05). The only subgroup that did not show a statistical difference between the alternative strategy and the control was 'the use of alternative photo-initiators' (pâ¯=â¯0.29). CONCLUSION: Modification of the resin matrix made the largest contribution to minimizing stress development. The technology used for decreasing stress in the formulation of low-shrinkage and bulk-fill materials was shown to be a promising application for reducing and controlling stress development.
Assuntos
Polimerização , Resinas Sintéticas/química , Estresse Mecânico , Análise de Elementos Finitos , Teste de MateriaisRESUMO
PURPOSE: A systematic review was conducted to determine whether there were any alternative technique or additional step strategies available to reduce and control polymerization shrinkage stress development in dental resin-based restorative materials. DATA SOURCES: This report followed the PRISMA Statement. A total of 36 studies were included in this review. Two reviewers performed a literature search up to December 2016, without restriction of the year of publication, in seven databases: PubMed, Web of Science, Scopus, SciELO, LILACS, IBECS, and BBO. STUDY SELECTION: Only in vitro studies that evaluated polymerization shrinkage stress by direct testing were included. Pilot studies, reviews and in vitro studies that evaluated polymerization shrinkage stress by indirect methods (e.g., microleakage or cuspal deflection measurements), finite elemental analysis or mathematical models were excluded. Of the 6.113 eligible articles, 36 studies were included in the qualitative analysis, and the meta-analysis was performed with 25 studies. A global comparison was performed with random-effects models (αâ¯=â¯0.05). The strategies were subdivided as follows: the use of an alternative technique protocol of placing the material inside the tooth cavity; the modification of the irradiation intensity or total energy delivered to the material; the use of an alternative light-curing source; or the use of an alternative photo-activation mode. All alternative strategies showed statistically significant differences when compared with their respective controls (pâ¯<â¯0.05). CONCLUSION: The use of alternative light-curing sources contributed more to minimizing stress development than placing the material by means of an alternative technique protocol or by modifying the irradiant intensity or total energy delivered to the material during photo-activation. Moreover, the use of an alternative photo-activation mode (intermittent light, exponential, soft-start or pulse delay modes) was shown to be an effective strategy for reducing and controlling stress development in resin-based dental materials.
Assuntos
Processos Fotoquímicos , Polimerização , Resinas Sintéticas/química , Estresse Mecânico , Análise de Elementos FinitosRESUMO
OBJECTIVES: To compare bulk-fill with incremental filling techniques for restoring large mesio-occlusal-distal (MOD) restorations. METHODS: Seventy-five molars with MOD preparations were divided into five groups: Z350XT, incrementally filled with Filtek Z350XT and four bulk-fills-FBF/Z350XT, Filtek Bulk Fill/Filtek Z350XT; VBF/CHA, Venus Bulk Fill/Charisma Diamond; SDR/EST-X, SDR/Esthet-X HD; TEC, TetricEvoCeram Bulk Fill. Cuspal strains were measured using strain-gauges (n=10): CSt-Re, during restorative procedure; CSt-100N, during 100N occlusal loading; CSt-Fr, at fracture load. Before fracture load, teeth were load-cycled. Fracture resistance, fracture mode, and enamel cracks were recorded. The other five teeth were used for Elastic modulus (E) and Vickers hardness (VH). Post-gel shrinkage (Shr), diametral tensile strength (DTS) and compressive strength (CS) were determined (n=10). Shrinkage stresses were analyzed using finite element analysis. RESULTS: SDR had similar CS values as TEC, lower than all other composites. CHA had similar DTS values as Z350XT, higher than all other composites. Z350XT had the highest mean Shr and SDR the lowest Shr. New enamel cracks and propagation was observed after the restoration, regardless of filling technique. Z350XT had lower fracture resistance than bulk-fill composite techniques. No significant differences in failure modes were found. E and VH were constant through the depth for all techniques. Bulk-filling techniques had lower stresses compared to Z350XT. CONCLUSIONS: Flowable bulk-fill composites had lower mechanical properties than paste bulk-fill and conventional composites. All bulk-fill composites had lower post-gel shrinkage than conventional composite. Bulk-fill filling techniques resulted in lower cusp strain, shrinkage stress and higher fracture resistance. CLINICAL SIGNIFICANCE: Using bulk-fill composites cause lower CSt wich indicates lower stress in restored tooth. Furthermore, bulk-fill composites have a higher fracture resistance. Therefore, clinicians may choose the bulk-fill composite to decrease undesirable effects of restoration while simplifying filling procedure.
Assuntos
Resinas Compostas/química , Restauração Dentária Permanente/métodos , Análise do Estresse Dentário , Preparo da Cavidade Dentária/métodos , Esmalte Dentário/fisiopatologia , Materiais Dentários/química , Análise de Elementos Finitos , Humanos , Metacrilatos/química , Dente Molar , Estresse MecânicoRESUMO
The longevity of resin depends on its binding between the margin of restorations and the polymer, and one factor that influences this aspect is the shrinkage stress. Thus, the working group presents the following systematic review thatverifies the influence of composite resin composition on shrinkage stress. The following electronic databases were searched: MEDLINE (via Ovid and PubMed - 2004 to January 2014), with the keywords: shrinkage stress, degree of conversion, resin composite. For shrinkage stress,, the best results were found when the BISGMA monomer was used and for the inorganic composition, an inverse relationship was observed: the increased inorganic filler content decreases shrinkage stress.
A longevidade de resina depende da sua ligação entre a margem de restaurações e o polímero, e um fator que influencia a este aspecto, é a tensão de contração. Assim, o grupo de trabalho faz a seguinte análise sistemática para verificar a influência da composição das resinas composta na tensão de contração. As seguintes bases de dados eletrônicas foram pesquisadas: MEDLINE (via PubMed e Ovídio - de 2004 a janeiro de 2014), com as palavras-chave: estresse de contração, grau de conversão, resina composta. Para tensão de contração, os melhores resultados foram encontrados quando o monômero BISGMA foi utilizada e para a composição inorgânica, uma relação inversa foi observada: o aumento do teor de carga inorgânica diminui estresse de contração.
Assuntos
Resinas Compostas , Análise do Estresse DentárioRESUMO
Este artigo tem como objetivo avaliar as tensões de contração de um compósito geradas pela polimerização em função da área aderida. Cilindros de vidro com 2 mm de diâmetro (G1) ou com 4 mm (G2) foram posicionados nas porções inferior e superior da máquina de testes. A distância dos cilindros de G1 era 2 mm e de G2 1 mm. Em cada grupo, a resina (Fill-Magic - Vigodent) foi inserida e fotoativada entre os cilindros e a t ensão m edida p or 1 5 m inutos ( n = 5 ). Os dados foram analisados pelo teste t-Student (p< 0,05). A maior área de adesão gerou menor tensão de contração para o material testado.
The aim of this study is to evaluate the shrinkage stress generated during polymerization of a composite resin related to the adhesion area. Cylinders of glass with 2 mm in diameter (G1) or 4 mm (G2) were positioned on the upper and lower portions of the testing machine. The distance from the cylinders was 2 mm in G1 and 1 mm in G2. In each group, the resin (Fill-Magic - Vigodent) was inserted and photopolymerized between the cylinders and the stress was measured for 15minutes (n = 5). Data were analyzed by Student t test (p < 0,05). The largest area of adhesion generated lower shrinkage stress to the tested material.
Assuntos
Resinas Compostas , Cura Luminosa de Adesivos Dentários , PolimerizaçãoRESUMO
The purpose of this study was to compare the polymerization shrinkage stress of composite resins (microfilled, microhybrid and hybrid) photoactivated by quartz-tungsten halogen light (QTH) and light-emitting diode (LED). Glass rods (5.0 mm x 5.0 cm) were fabricated and had one of the surfaces air-abraded with aluminum oxide and coated with a layer of an adhesive system, which was photoactivated with the QTH unit. The glass rods were vertically assembled, in pairs, to a universal testing machine and the composites were applied to the lower rod. The upper rod was placed closer, at 2 mm, and an extensometer was attached to the rods. The 20 composites were polymerized by either QTH (n=10) or LED (n=10) curing units. Polymerization was carried out using 2 devices positioned in opposite sides, which were simultaneously activated for 40 s. Shrinkage stress was analyzed twice: shortly after polymerization (t40s) and 10 min later (t10min). Data were analyzed statistically by 2-way ANOVA and Tukey's test (a=5 percent). The shrinkage stress for all composites was higher at t10min than at t40s, regardless of the activation source. Microfilled composite resins showed lower shrinkage stress values compared to the other composite resins. For the hybrid and microhybrid composite resins, the light source had no influence on the shrinkage stress, except for microfilled composite at t10min. It may be concluded that the composition of composite resins is the factor with the strongest influence on shrinkage stress.
Este estudo comparou a contração de polimerização de resinas compostas fotoativadas por luz halógena (QTH) e diodo emissor de luz (LED). Foram confeccionados bastões de vidro (5,0 mm x 5,0 cm), e uma de suas extremidades sofreu jateamento com óxido de alumínio, sobre a qual foi aplicado um adesivo e fotoativado com luz halógena. Os bastões de vidro foram acoplados verticalmente, em pares, em uma máquina universal de ensaios (EMIC DL-2000) e as resinas compostas aplicadas no bastão inferior. A distância entre os bastões foi padronizada em 2 mm e um extensômetro foi acoplado a eles. As resinas foram fotoativadas (n=20), sendo 10 por QTH e 10 por LED utilizando dois aparelhos posicionados em lados opostos, acionados simultaneamente por 40 s. A tensão de contração foi analisada em dois momentos: logo após a polimerização (t40s) e 10 min após (t10min). A tensão de contração apresentada por todas as resinas foi maior em t10min do que em t40s, independente da fonte ativadora. A resina de micropartículas apresentou menores valores de tensão de contração com valores estatisticamente significantes em relação às demais resinas. Para as resinas híbrida e microhíbrida não houve influência da unidade ativadora sobre a tensão de contração, com exceção para a resina de micropartículas em t10min. Concluiu-se que a composição da resina composta foi o fator que mais interferiu na tensão de contração da resina composta.
Assuntos
Resinas Compostas/efeitos da radiação , Lâmpadas de Polimerização Dentária/classificação , Cura Luminosa de Adesivos Dentários/métodos , Materiais Dentários/efeitos da radiação , Análise de Variância , Resinas Acrílicas/química , Resinas Acrílicas/efeitos da radiação , Resinas Compostas/química , Análise do Estresse Dentário , Materiais Dentários/química , Adesivos Dentinários/química , Adesivos Dentinários/efeitos da radiação , Teste de Materiais , Nanopartículas/química , Nanopartículas/efeitos da radiação , Poliuretanos/química , Poliuretanos/efeitos da radiação , Cimentos de Resina/química , Cimentos de Resina/efeitos da radiação , Estatísticas não ParamétricasRESUMO
The aim of this study was to compare the shrinkage stress of composite resins by three methods. In the first method, composites were inserted between two stainless steel plates. One of the plates was connected to a 20 kgf load cell of a universal testing machine (EMIC-DL-500). In the second method, disk-shaped cavities were prepared in 2-mm-thick Teflon molds and filled with the different composites. Gaps between the composites and molds formed after polymerization were evaluated microscopically. In the third method, the wall-to-wall shrinkage stress of the resins that were placed in bovine dentin cavities was evaluated. The gaps were measured microscopically. Data were analyzed by one-way ANOVA and Tukey's test (alpha=0.05). The obtained contraction forces were: Grandio = 12.18 ± 0.428N; Filtek Z 250 = 11.80 ± 0.760N; Filtek Supreme = 11.80 ± 0.707 N; and Admira = 11.89 ± 0.647 N. The gaps obtained between composites and Teflon molds were: Filtek Z 250 = 0.51 ± 0.0357 percent; Filtek Supreme = 0.36 ± 0.0438 percent; Admira = 0.25 ± 0.0346 percent and Grandio = 0.16 ± 0.008 percent. The gaps obtained in wall-to-wall contraction were: Filtek Z 250 = 11.33 ± 2.160 µm; Filtek Supreme = 10.66 ± 1.211µm; Admira = 11.16 ± 2.041 µm and Grandio = 10.50 ± 1.224 µm. There were no significant differences among the composite resins obtained with the first (shrinkage stress generated during polymerization) and third method (wall-to-wall shrinkage). The composite resins obtained with the second method (Teflon method) differed significantly regarding gap formation.