Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39313704

RESUMO

The study aimed to evaluate the effects of supplementation with Lacticaseibacillus casei CSL3 in Swiss mice immunosuppressed with cyclophosphamide on immunological, biochemical, oxidative stress, and histological parameters. The animals were distributed into four groups (control, CSL3, cyclophosphamide, and CSL3 + cyclophosphamide), where two groups were treated with L. casei CSL3 (10 log CFU mL-1) for 30 days, and two groups received chemotherapy (days 27 and 30-total dose of 250 mg kg-1). Counts of lactic acid bacteria (LAB) and bile-resistant LAB in stool samples; blood count (erythrogram, leukogram, and platelets); serum total cholesterol levels; catalase enzyme activity; and thiobarbituric acid reactive substances (TBARS) levels in liver, kidney, and brain; IL-4 expression; IL-23, TNF-α, NF-κß in the spleen; and histological changes in the liver, kidneys, and intestine were evaluated. The CSL3 + cyclophosphamide group showed a significant increase in bile-resistant LAB counts in feces (p = 0.0001), leukocyte counts, and expression of IL-23, TNF-α, and NF-κß (p < 0.05) significantly reduced total cholesterol levels (p = 0.001) and protected liver damage of supplemented animals. For oxidative stress damage, the bacterium did not influence the results. It is concluded that the bacterium is safe at a concentration of 10 log CFU mL-1 and has probiotic potential due to its positive influence on the immune response and lipid metabolism.

2.
J Med Primatol ; 49(4): 211-217, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32175604

RESUMO

BACKGROUND: Wild capuchin monkeys (Sapajus libidinosus) usually are found in conserved forests near the zoo and the urban areas of Brasília city, Brazil. In this study, some capuchin monkeys were captured using traps, followed by safe biological procedures for their overall health analysis, based on specific haematological and biochemical tests of blood samples. METHODS: Blood was collected from a total of 17 monkeys for the determination of parameters, namely packed cell volume (PCV), leucocytes, erythrocytes, platelets and triglycerides. Statistical analyses for average values, median, standard deviation and range were performed. RESULTS: These parameters were set based on the minimum and maximum values obtained from the blood tests. Data are presented in tabulated form. CONCLUSIONS: Capture procedures were based on animal safety analysis for free-living animals and would help future studies on wild animals. The collected samples used in this study suggested the animals to be apparently healthy in their habitat.


Assuntos
Análise Química do Sangue/veterinária , Cebinae/sangue , Testes Hematológicos/veterinária , Animais , Animais Selvagens/sangue , Brasil , Feminino , Masculino
3.
J Mass Spectrom ; 51(3): 200-6, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26956387

RESUMO

Piscirickettsia salmonis is a pathogenic bacteria known as the aetiological agent of the salmonid rickettsial syndrome and causes a high mortality in farmed salmonid fishes. Detection of P. salmonis in farmed fishes is based mainly on molecular biology and immunohistochemistry techniques. These techniques are in most of the cases expensive and time consuming. In the search of new alternatives to detect the presence of P. salmonis in salmonid fishes, this work proposed the use of MALDI-TOF-MS to compare serum protein profiles from Salmo salar fish, including experimentally infected and non-infected fishes using principal component analysis (PCA). Samples were obtained from a controlled bioassay where S. salar was challenged with P. salmonis in a cohabitation model and classified according to the presence or absence of the bacteria by real time PCR analysis. MALDI spectra of the fish serum samples showed differences in its serum protein composition. These differences were corroborated with PCA analysis. The results demonstrated that the use of both MALDI-TOF-MS and PCA represents a useful tool to discriminate the fish status through the analysis of salmonid serum samples.


Assuntos
Proteínas de Bactérias/sangue , Piscirickettsia/isolamento & purificação , Infecções por Piscirickettsiaceae , Salmo salar/microbiologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Infecções por Piscirickettsiaceae/sangue , Infecções por Piscirickettsiaceae/microbiologia , Infecções por Piscirickettsiaceae/veterinária
4.
Arq. Inst. Biol ; 83: 01-05, 2016. tab
Artigo em Português | VETINDEX | ID: biblio-1462382

RESUMO

In the present study, folic acid and fumonisin B1 (FB1 ) levels were determined in corn flour consumed by 24 volunteers, residents in a university campus in São Paulo State, as well as its relationship with folic acid in serum of individuals. Analyses of folic acid and FB1 in corn flour were performed by highperformance liquid chromatography (HPLC), while the determination of folic acid in serum was accomplished using an immunoassay kit. FB1 was detected in 100% of corn samples, at levels ranging from 142 to 3,037  µg  kg1 (which means: 738  ±  591  µg  kg1). The concentrations of folic acid in corn flour samples ranged from  0.3 µg kg1 (limit of quantification) to 1,705 µg kg1, with a mean of 713 ± 435 µg kg1, which represents 47% of the minimum required by National Agency of Health Surveillance (ANVISA) for corn flour commercially available. The levels of folic acid in human serum samples ranged from 6.7 to 24.0 ng mL1 (meaning: 13.4 ± 5.4 ng mL1). No correlations were observed (p   0.05) between the folic acid levels in serum of individuals and the concentrations of FB1 or folic acid in corn flour samples. Further studies are needed to estimate the total intake of FB1 in the diet to assess the effects fumonisins on the absorption of folic acid in the individuals evaluated.


Neste trabalho foram determinados os níveis de ácido fólico e de fumonisina B1 (FB1 ) em farinha de milho consumida por 24 voluntários residentes em um campus universitário no estado de São Paulo, bem como sua relação com as concentrações de ácido fólico sérico nos indivíduos. As análises de ácido fólico e de FB1 em farinha de milho foram realizadas por cromatografia líquida de alta eficiência (CLAE), enquanto a determinação de ácido fólico sérico foi feita por kit de imunoensaio. Detectouse a FB1 em 100% das amostras de farinha de milho, em níveis que variaram de 142 a 3.037 µg kg1 (média: 738 ± 591 µg kg1). As concentra ções de ácido fólico nas amostras de farinha de milho ficaram entre  0,3 µg kg1 (limite de quantificação) e 1.705 µg kg1, com média de 713 ± 435 µg kg1, o que representa 47% do limite mínimo exigido pela Agência Nacional de Vigilância Sanitária (ANVISA) para farinhas de milho comercialmente disponíveis. Nas amos tras de soro humano, os níveis de ácido fólico variaram de 6,7 a 24,0 ng mL1 (média: 13,4 ± 5,4 ng mL1). Não houve correlação (p   0,05) entre os níveis de ácido fólico no soro dos indivíduos e as concentrações de FB1 ou ácido fólico nas amostras de farinha de milho. Outros estudos são necessários para estimar a ingestão total de FB1 por meio da dieta para averiguar os efeitos das fumo nisinas sobre a absorção de ácido fólico nos indivíduos e as concentrações de FB1 ou ácido fólico nas amostras de farinha de milho. Outros estudos são necessários para estimar a ingestão total de FB1 por meio da dieta para averiguar os efeitos das fumonisinas sobre a absorção de ácido fólico nos indivíduos avaliados.


Assuntos
Humanos , Farinha , Fumonisinas/sangue , Soro , Zea mays/química , Ácido Fólico/sangue , Voluntários Saudáveis
5.
Arq. Inst. Biol. ; 83: 01-05, 2016. tab
Artigo em Português | VETINDEX | ID: vti-731078

RESUMO

In the present study, folic acid and fumonisin B1 (FB1 ) levels were determined in corn flour consumed by 24 volunteers, residents in a university campus in São Paulo State, as well as its relationship with folic acid in serum of individuals. Analyses of folic acid and FB1 in corn flour were performed by highperformance liquid chromatography (HPLC), while the determination of folic acid in serum was accomplished using an immunoassay kit. FB1 was detected in 100% of corn samples, at levels ranging from 142 to 3,037  µg  kg1 (which means: 738  ±  591  µg  kg1). The concentrations of folic acid in corn flour samples ranged from  0.3 µg kg1 (limit of quantification) to 1,705 µg kg1, with a mean of 713 ± 435 µg kg1, which represents 47% of the minimum required by National Agency of Health Surveillance (ANVISA) for corn flour commercially available. The levels of folic acid in human serum samples ranged from 6.7 to 24.0 ng mL1 (meaning: 13.4 ± 5.4 ng mL1). No correlations were observed (p   0.05) between the folic acid levels in serum of individuals and the concentrations of FB1 or folic acid in corn flour samples. Further studies are needed to estimate the total intake of FB1 in the diet to assess the effects fumonisins on the absorption of folic acid in the individuals evaluated.(AU)


Neste trabalho foram determinados os níveis de ácido fólico e de fumonisina B1 (FB1 ) em farinha de milho consumida por 24 voluntários residentes em um campus universitário no estado de São Paulo, bem como sua relação com as concentrações de ácido fólico sérico nos indivíduos. As análises de ácido fólico e de FB1 em farinha de milho foram realizadas por cromatografia líquida de alta eficiência (CLAE), enquanto a determinação de ácido fólico sérico foi feita por kit de imunoensaio. Detectouse a FB1 em 100% das amostras de farinha de milho, em níveis que variaram de 142 a 3.037 µg kg1 (média: 738 ± 591 µg kg1). As concentra ções de ácido fólico nas amostras de farinha de milho ficaram entre  0,3 µg kg1 (limite de quantificação) e 1.705 µg kg1, com média de 713 ± 435 µg kg1, o que representa 47% do limite mínimo exigido pela Agência Nacional de Vigilância Sanitária (ANVISA) para farinhas de milho comercialmente disponíveis. Nas amos tras de soro humano, os níveis de ácido fólico variaram de 6,7 a 24,0 ng mL1 (média: 13,4 ± 5,4 ng mL1). Não houve correlação (p   0,05) entre os níveis de ácido fólico no soro dos indivíduos e as concentrações de FB1 ou ácido fólico nas amostras de farinha de milho. Outros estudos são necessários para estimar a ingestão total de FB1 por meio da dieta para averiguar os efeitos das fumo nisinas sobre a absorção de ácido fólico nos indivíduos e as concentrações de FB1 ou ácido fólico nas amostras de farinha de milho. Outros estudos são necessários para estimar a ingestão total de FB1 por meio da dieta para averiguar os efeitos das fumonisinas sobre a absorção de ácido fólico nos indivíduos avaliados.(AU)


Assuntos
Humanos , Soro , Farinha , Zea mays/química , Fumonisinas/sangue , Ácido Fólico/sangue , Voluntários Saudáveis
6.
Arq. Inst. Biol ; 83: e0972014, 2016. tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-1006452

RESUMO

Neste trabalho foram determinados os níveis de ácido fólico e de fumonisina B1 (FB1) em farinha de milho consumida por 24 voluntários residentes em um campus universitário no estado de São Paulo, bem como sua relação com as concentrações de ácido fólico sérico nos indivíduos. As análises de ácido fólico e de FB1 em farinha de milho foram realizadas por cromatografia líquida de alta eficiência (CLAE), enquanto a determinação de ácido fólico sérico foi feita por kit de imunoensaio. Detectou-se a FB1 em 100% das amostras de farinha de milho, em níveis que variaram de 142 a 3.037 µg kg-1 (média: 738 ± 591 µg kg-1). As concentrações de ácido fólico nas amostras de farinha de milho ficaram entre < 0,3 µg kg-1 (limite de quantificação) e 1.705 µg kg-1, com média de 713 ± 435 µg kg-1, o que representa 47% do limite mínimo exigido pela Agência Nacional de Vigilância Sanitária (ANVISA) para farinhas de milho comercialmente disponíveis. Nas amostras de soro humano, os níveis de ácido fólico variaram de 6,7 a 24,0 ng mL-1 (média: 13,4 ± 5,4 ng mL-1). Não houve correlação (p < 0,05) entre os níveis de ácido fólico no soro dos indivíduos e as concentrações de FB1 ou ácido fólico nas amostras de farinha de milho. Outros estudos são necessários para estimar a ingestão total de FB1 por meio da dieta para averiguar os efeitos das fumonisinas sobre a absorção de ácido fólico nos indivíduos avaliados.(AU)


In the present study, folic acid and fumonisin B1 (FB1) levels were determined in corn flour consumed by 24 volunteers, residents in a university campus in São Paulo State, as well as its relationship with folic acid in serum of individuals. Analyses of folic acid and FB1 in corn flour were performed by high-performance liquid chromatography (HPLC), while the determination of folic acid in serum was accomplished using an immunoassay kit. FB1 was detected in 100% of corn samples, at levels ranging from 142 to 3,037 µg kg-1 (which means: 738 ± 591 µg kg-1). The concentrations of folic acid in corn flour samples ranged from < 0.3 µg kg-1 (limit of quantification) to 1,705 µg kg-1, with a mean of 713 ± 435 µg kg-1, which represents 47% of the minimum required by National Agency of Health Surveillance (ANVISA) for corn flour commercially available. The levels of folic acid in human serum samples ranged from 6.7 to 24.0 ng mL-1 (meaning: 13.4 ± 5.4 ng mL-1). No correlations were observed (p < 0.05) between the folic acid levels in serum of individuals and the concentrations of FB1 or folic acid in corn flour samples. Further studies are needed to estimate the total intake of FB1 in the diet to assess the effects fumonisins on the absorption of folic acid in the individuals evaluated.(AU)


Assuntos
Humanos , Zea mays/química , Fumonisinas/sangue , Soro , Farinha , Ácido Fólico/sangue , Voluntários Saudáveis
7.
Braz. j. pharm. sci ; 51(2): 285-294, Apr.-June 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-755069

RESUMO

This article describes a differential pulse voltammetric (DPV) method for the determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electro-oxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL-1and 2-20 μg mL-1 in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.87, and accuracy (relative error) was better than 4.12%. The method developed in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. In addition, the proposed technique was successfully applied to spiked human serum samples. No electro-active interferences from the endogenous substances were found in human serum...


Este artigo descreve um método de voltametria de pulso diferencial (VPD) para a determinação de diclofenaco em preparações farmacêuticas e em soro humano. O método proposto foi baseado em eletroxidação de diclofenaco no eléctrodo de platina em solução 0,1 M TBAClO4/acetonitrila. Dois picos de oxidação bem definidos foram observados em 0,87 e 1,27 V, respectivamente. As curvas de calibração obtidas utilizando-se valores de corrente medidos por segundo pico foram lineares no intervalo de concentração de 1,5-17,5 μg mL-1e 2-20 μg mL-1em eletrólito suporte e soro, respectivamente. Precisão e exatidão também foram verificadas em todos os meios. Valores de precisão intra- e inter-dia para o diclofenaco foram inferiores a 3.87 e a precisão (erro relativo) foi melhor do que 4,12%. O método desenvolvido neste estudo é exato, preciso e pode ser facilmente aplicado a Diclomec, Dicloflam e comprimidos Voltaren, como preparação farmacêutica. Além disso, a técnica proposta foi aplicada com sucesso em amostras de soro humano. Não se observaram interferências das substâncias endógenas no soro humano...


Assuntos
Humanos , Diclofenaco/análise , Diclofenaco/farmacologia , Diclofenaco/sangue , Testes de Química Clínica/métodos , Química Farmacêutica/métodos , Técnicas Eletroquímicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA