Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Shoulder Elb Arthroplast ; 8: 24715492241266131, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39156496

RESUMO

Purpose: To evaluate both the short-term clinical and radiological results of reverse shoulder arthroplasty (RSA) with uncemented locked stem in the management of a proximal humerus fracture (PHFs) in the elderly. Methods: Retrospective study including 40 consecutive 3-4 part proximal humerus fractures treated with reverse shoulder arthroplasty with a minimum of 24 months follow-up. In all the cases, the greater tuberosity (GT) was reattached with a standardized suture technique and a local horseshoe bone graft. All the patients were assessed at the 24-month follow-up with Constant-Murley Score (CMS) and Visual Analog Score (VAS). Radiographic healing of the greater tuberosity was noted in addition to stem locking screws radiographic changes. Complications and revision rates were reported. Results: Mean final CMS for this cohort was 80 points. The greater tuberosity healed in the anatomic position in 90% of the cases (N = 36), obtaining an average CMS of 80 in these patients. Healing of the greater tuberosity did not occur in 10% of the cases (N = 4), obtaining an average CMS of 60. All patients scored above 100° in forward elevation with a mean of 140°. Mean active external rotation was 30°. Low-grade scapular notching was reported in <1% of the cases. Major complications were reported in one patient with an acromial fracture. No complications or loosening of stem locking screws were noted. There were no reoperations. Conclusion: In the elderly population, reverse shoulder arthroplasty utilizing a fracture-specific locking stem, low-profile metaphysis, suture-friendly groove, meticulous suture technique, and local bone grafting allows adequate fixation, variable prosthesis height adjustment, and enhances greater tuberosity healing. This approach yields positive short-term clinical outcomes without complications related to the stem's locking screws. Level of Evidence: Level IV Retrospective Case Series.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38942222

RESUMO

BACKGROUND: Navigated augmented reality (AR) through a head-mounted display (HMD) has led to accurate glenoid component placement in reverse shoulder arthroplasty (RSA) in an in-vitro setting. The purpose of this study is to evaluate the deviation between planned, intraoperative, and postoperative inclination, retroversion, entry point, and depth of the glenoid component placement during RSA, assisted by navigated AR through an HMD, in a surgical setting. METHODS: A prospective, multicenter study was conducted. All consecutive patients undergoing RSA in 2 institutions, between August 2021 and January 2023, were considered potentially eligible for inclusion in the study. Inclusion criteria were as follows: age >18 years, surgery assisted by AR through an HMD, and postoperative computed tomography (CT) scans at 6 weeks. All participants agreed to participate in the study and informed consent was provided in all cases. Preoperative CT scans were undertaken for all cases and used for 3-dimensional (3D) planning. Intraoperatively, glenoid preparation and component placement were assisted by a navigated AR system through an HMD in all patients. Intraoperative parameters were recorded by the system. A postoperative CT scan was undertaken at 6 weeks, and 3D reconstruction was performed to obtain postoperative parameters. The deviation between planned, intraoperative, and postoperative inclination, retroversion, entry point, and depth of the glenoid component placement was calculated. Outliers were defined as >5° for inclination and retroversion and >5 mm for entry point. RESULTS: Seventeen patients (9 females, 12 right shoulders) with a mean age of 72.8 ± 9.1 years (range, 47.0-82.0) met inclusion criteria. The mean deviation between intra- and postoperative measurements was 1.5° ± 1.0° (range, 0.0°-3.0°) for inclination, 2.8° ± 1.5° (range, 1.0°-4.5°) for retroversion, 1.8 ± 1.0 mm (range, 0.7-3.0 mm) for entry point, and 1.9 ± 1.9 mm (range, 0.0-4.5 mm) for depth. The mean deviation between planned and postoperative values was 2.5° ± 3.2° (range, 0.0°-11.0°) for inclination, 3.4° ± 4.6° (range, 0.0°-18.0°) for retroversion, 2.0 ± 2.5 mm (range, 0.0°-9.7°) for entry point, and 1.3 ± 1.6 mm (range, 1.3-4.5 mm) for depth. There were no outliers between intra- and postoperative values and there were 3 outliers between planned and postoperative values. The mean time (minutes : seconds) for the tracker unit placement and the scapula registration was 03:02 (range, 01:48 to 04:26) and 08:16 (range, 02:09 to 17:58), respectively. CONCLUSION: The use of a navigated AR system through an HMD in RSA led to low deviations between planned, intraoperative, and postoperative parameters for glenoid component placement.

3.
Rev.Chil Ortop Traumatol ; 65(1): 1-8, abr.2024. graf, tab
Artigo em Espanhol | LILACS | ID: biblio-1554748

RESUMO

OBJETIVO Comparar los resultados funcionales obtenidos en dos cohortes de pacientes ancianos tratados de forma quirúrgica (artroplastia reversa de hombro) versus tratamiento conservador. MATERIAL Y METODOS Estudio ambispectivo, no aleatorizado. Se incluyeron pacientes de 75 años o más, 15 tratados de forma quirúrgica y 16 siguieron tratamiento conservador. Seguimiento mínimo de 12 meses. A los 3, 6 y 12 meses de la fractura evaluamos las escalas ASES, Constant-Murley and Disabilities of the Arm, Shoulder and Hand score (DASH) y EVA. Además evaluamos los resultados radiológicos y las complicaciones. RESULTADOS No encontramos diferencias significativas para las escalas ASES, DASH, ni EVA .El grupo tratado de forma quirúrgica obtuvo a los 12 meses una puntuación media en la escala Constant mayor, diferencia estadísticamente significativa(75.1 þ/-10.3 vs. 51.9 þ/-12.4 p » 0.001). Además presentaban mayor rango de movilidad para flexión y rotación externa (128.9 þ/-17 versus 99.3 þ/-20.1 p » 0.001, and 35.7 þ/-13.9 vs. 23.4 þ/-15.5 p » 0.032). El 43% de los pacientes tratados mediante artroplastia reversa presentaban tuberosidades normoposicionadas y mejores resultados en las escalas versus pacientes con tuberosidades ausentes o malposicionadas. El grupo sometido a cirugía no presentó mayor tasa de complicaciones.CONCLUSIONES El tratamiento conservador en las fracturas de EPH en tres y cuatro fragmentos en pacientes ancianos ofrece buenos resultados en cuanto a dolor y funcionalidad en la mayoría de pacientes. Falta por definir qué pacientes por tener alta demanda funcional serían candidatos a tratamiento quirúrgico de entrada


OBJECTIVE This study compared functional results in two cohorts of older adults with three- and four-part proximal humeral fractures (PHFs) per Neer's classification treated with reverse shoulder arthroplasty (RSA) or nonoperative management. MATERIALS AND METHODS Ambispective, non-randomized study with two cohorts of patients aged 75 or older treated with RSA (n » 15) or nonoperative management (n » 16) with a minimum follow-up period of 12 months. We analyzed the American Shoulder and Elbow Surgeons (ASES), Constant-Murley, and Disabilities of the Arm, Shoulder, and Hand (DASH) scores and the visual analog scale (VAS) for pain at 3, 6, and 12 months. In addition, we recorded radiological findings and surgical complications. RESULTS The mean Constant-Murley score at 12 months was significantly higher for the RSA group (75.1 þ/- 10.3 vs. 51.9 þ/- 12.4, p » 0.001). There were no differences in ASES, DASH, and VAS scores. Statistically significant differences for flexion and external rotation in abduction favored the RSA group (128.9 þ/- 17.0 versus 99.3 þ/- 20.1, p » 0.001, and 35.7 þ/- 13.9 vs. 23.4 þ/- 15.5, p » 0.032, respectively). For the RSA group, tuberosity positioning was correct in 43% of subjects. These patients presented better scores than those with malpositioned or absent tuberosities but with no statistical significance. Complications in the surgical group were not higher. CONCLUSIONS Nonoperative treatment is a valid option regarding pain and functionality in elderly patients with three- and four-part PHFs. Characteristics of patients with high demands who may be candidates for the initial surgical treatment remain to be defined


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Fraturas do Ombro/cirurgia , Fraturas do Ombro/terapia , Fraturas do Ombro/diagnóstico por imagem , Resultado do Tratamento , Assistência ao Convalescente , Tratamento Conservador/métodos , Artroplastia do Ombro/métodos
5.
BMC Musculoskelet Disord ; 25(1): 13, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167047

RESUMO

BACKGROUND: Reverse shoulder arthroplasty (RSA) is a valuable treatment for rotator cuff arthropathy (RCA) in developed regions. Socioeconomic issues impact access to specialized care and there is a lack of data on RSA outcomes in developing regions. We present our 24-month follow-up on RSA surgeries to treat RCA in our low-income population. METHODS: Prospective evaluation of 26 patients subjected to RSA at Hospital Geral de Fortaleza-CE, Brazil, between January 2018 and December 2020. Literacy [>/≤ 8 school years(SY)] and income were documented. Outcomes considered pain (visual analogue scale; VAS) as well as SSV, SPADI, ASES, and UCLA scoring, and range of motion [forward flexion (FF); external rotation (ER)]. RESULTS: Patients were 68.5 ± 7.6 years-old with 16(61.5%) females; 65% had hypertension and 7 (26.9%) had diabetes. Over 90% declared < 900.00 US$ monthly family earnings and 10 (38.4%) patients declared ≤8 SY with > 80% exerting blue-collar jobs. Pain showed a significant reduction from baseline (8 ± 2) to 24 months (2.1 ± 2.3; p < 0.001). UCLA (10.3 ± 5.6 and 28.6 ± 7.2), ASES (16.7 ± 10.8 and 63.1 ± 28.4), SSV (326 ± 311 and 760 ± 234), and SPADI (98.3 ± 26.5) scores significantly improved from baseline to 24 months, achieving minimal clinically important difference. FF (89.2° ± 51.2° to 140.6 ± 38.3°) and ER (19.2° ± 22.5 to 33.4° ± 20.6°) significantly improved from baseline to 24 months (p = 0.004 and 0.027, respectively). There were 5 non-serious adverse events with one surgical revision. All patients returned to daily life activities. CONCLUSION: This is the first outcome report 2 years following RSA in a low-income population. Data indicate this procedure is justifiable regardless of socioeconomic issues.


Assuntos
Artroplastia do Ombro , Artropatias , Lesões do Manguito Rotador , Articulação do Ombro , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Manguito Rotador/cirurgia , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento , Artropatias/cirurgia , Amplitude de Movimento Articular , Dor , Pobreza , Articulação do Ombro/cirurgia , Estudos Retrospectivos
6.
J Shoulder Elbow Surg ; 32(12): e587-e596, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37276917

RESUMO

BACKGROUND: Navigated augmented reality (AR) through a head-mounted display (HMD) may lead to accurate glenoid component placement in reverse shoulder arthroplasty (RSA). The purpose of this study is to evaluate the deviation between planned, intra- and postoperative inclination, retroversion, entry point, depth, and rotation of the glenoid component placement assisted by a navigated AR through HMD during RSA. METHODS: Both shoulders of 6 fresh frozen human cadavers, free from fractures or other bony pathologies, were used. Preoperative computed tomography (CT) scans were used for the 3-dimensional (3D) planning. The glenoid component placement was assisted using a navigated AR system through an HMD in all specimens. Intraoperative inclination, retroversion, depth, and rotation were measured by the system. A postoperative CT scan was performed. The pre- and postoperative 3D CT scan reconstructions were superimposed to calculate the deviation between planned and postoperative inclination, retroversion, entry point, depth, and rotation of the glenoid component placement. Additionally, a comparison between intra- and postoperative values was calculated. Outliers were defined as >10° inclination, >10° retroversion, >3 mm entry point. RESULTS: The registration algorithm of the scapulae prior to the procedure was correctly completed for all cases. The deviations between planned and postoperative values were 1.0° ± 0.7° for inclination, 1.8° ± 1.3° for retroversion, 1.1 ± 0.4 mm for entry point, 0.7 ± 0.6 mm for depth, and 1.7° ± 1.6° for rotation. The deviation between intra- and postoperative values were 0.9° ± 0.8° for inclination, 1.2° ± 1.1° for retroversion, 0.6 ± 0.5 mm for depth, and 0.3° ± 0.2° for rotation. There were no outliers between planned and postoperative parameters. CONCLUSION: In this study, the use of a navigated AR system through an HMD for RSA led to low deviation between planned and postoperative values and between intra- and postoperative parameters.


Assuntos
Artroplastia do Ombro , Realidade Aumentada , Cavidade Glenoide , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Artroplastia do Ombro/métodos , Escápula/cirurgia , Artroplastia , Cavidade Glenoide/cirurgia
7.
J Shoulder Elb Arthroplast ; 7: 24715492231167111, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37077712

RESUMO

Objective: The main objective was to evaluate the anterior flexion force (AFF) and the lateral abduction force (LAF) of patients who underwent reverse shoulder arthroplasty (RSA) and to compare the measured force with that in a similar-age control group. The secondary objective was to identify prognostic factors for muscle strength recovery. Methods: Forty-two shoulders that underwent primary RSA between September 2009 and April 2020 met the inclusion criteria and were called the arthroplasty group (AG). The control group (CG) consisted of 36 patients. The mean AFF and the mean LAF were evaluated with a digital isokinetic traction dynamometer. Results: The average AFF found in the AG was 15 N, while in the CG, the average AFF was 21 N (P < .001). The average LAF in the AG was 14 N (standard deviation [SD] 8 N), while in the CG the average LAF was of 19 N (SD 6 N) (P = .002). All prognostic factors studied in the AG showed no statistical significance: dominance (AFF 0.697/LAF 0.883), previous rotator cuff repair surgery (AFF 0.786/LAF 0.821), Hamada radiological classification (AFF 0.343/LAF 0.857), magnetic resonance imaging (MRI) pre-operative evaluation of the quality of the teres minor (AFF 0.131/LAF 0.229), suture of the subscapularis at the end of the arthroplasty procedure (AFF 0.961/LAF 0.325) and postoperative complications (AFF 0.600/LAF 0.960). Conclusion: The mean AFF was 15 N, and the mean LAF was 14 N. The comparison of AFF and LAF with a CG showed a 25% reduction in muscle strength. It was not possible to demonstrate prognostic factors for muscle strength recovery after RSA.

8.
J Shoulder Elb Arthroplast ; 7: 24715492231167110, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37008200

RESUMO

Purpose: To describe the reverse shoulder arthroplasty angle (RSA angle) in magnetic resonance imaging (MRI) and compare the angle formed using bony landmarks (Bony RSA angle or B-RSA angle) with another angle formed using the cartilage margin as reference (Cartilage RSA angle or C-RSA angle). Methods: Adult patients with a shoulder MRI obtained in our hospital between July 2020 and July 2021 were included. The C-RSA angle and B-RSA angle were measured. All images were independently assessed by 4 evaluators. Intraclass correlation coefficient (ICC) was determined for the B-RSA and C-RSA to evaluate interobserver agreement. Results: A total of 61 patients were included with a median age of 59 years (17-77). C-RSA angle was significantly higher than B-RSA (25.4° ± 0.7 vs 19.5° ± 0.7, respectively) with a P-value <.001. The overall agreement was considered "good" for C-RSA (ICC = 0.74 [95% CI 0.61-0.83]) and "excellent" for B-RSA angle (ICC = 0.76 [95% CI 0.65-0.85]). Conclusions: C-RSA angle is significantly higher than B-RSA angle. In cases without significant glenoid wear neglecting to account for the remaining articular cartilage at the inferior glenoid margin may result in superior inclination of standard surgical guides.

9.
J Orthop ; 36: 29-35, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36582549

RESUMO

Introduction: Navigation technologies have improved accuracy and precision in positioning glenoid components during shoulder arthroplasty. The influence of navigation on baseplate screw placement has not been independently investigated. This study aimed to evaluate and synthesize the best scientific evidence on the influence of intraoperative navigation on the length and number of screws for primary baseplate fixation in reverse total shoulder arthroplasty procedures. Methods: In August 2022, PubMed, Scopus, and Embase databases were accessed. We analyzed the screw purchase length, the number of screws required for the fixation of the baseplate, and the proportion of cases fixed with two screws in all clinical trials, comparing navigation to standard instrumentation for reverse shoulder arthroplasty. Following an evaluation of the heterogeneity of the studies, DerSimonian-Laird random-effects models were utilized to merge data from separate studies. Results: The systematic search revealed a total of 2034 articles. After excluding duplicates and irrelevant studies, 633 shoulder arthroplasties from 6 trials were included in the analysis. The pooled mean difference in screw purchase length was 5.839 mm (95 %CI 4.496 to 7. 182) in favor of navigation (P < .001). In addition, significant differences were also found in the number of screws per case (- 0.547, 95 %CI -0.890 to -0.203, P = .002) and in the proportion of cases fixed with two screws (Odds Ratio 3.182 95 %CI 1.057 to 9.579, P = .040) in favor of the navigation group. Conclusions: Intraoperative navigation improves the baseplate screw placement, allowing for a greater screw purchase length and fewer screws to achieve primary fixation of the glenoid component during reverse shoulder arthroplasty. It is unclear whether these improvements will increase the longevity of the prosthesis or the clinical outcomes of the patients.

10.
Ann Jt ; 8: 37, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38529225

RESUMO

Reverse shoulder arthroplasty (RSA) has become a highly successful treatment option for various shoulder conditions, leading to a significant increase in its utilization since its approval in 2003. However, postoperative complications, including scapular notching, prosthetic instability, and component loosening, remain a concern. These complications can often be attributed to technical errors during component implantation, emphasizing the importance of proper preoperative planning and accurate positioning of prosthetic components. Improper baseplate and glenosphere positioning in RSA have been linked to impingement, reduced range of motion, and increased scapular notching. Additionally, the relationship between component positioning and intrinsic stability of RSA has been established, with glenoid component retroversion exceeding 10° posing a risk to implant stability. Adequate initial glenoid baseplate fixation, achieved through optimal seating and the use of appropriate screws, is crucial for long-term success and prevention of early failure. Factors such as lateralization and distalization also influence outcomes and complications in RSA, yet standardized guidelines for preoperative planning in these parameters are still lacking. Despite the impact of component position on outcomes, glenoid component implantation remains challenging, with position errors being common even among experienced surgeons. Challenges arise due to factors such as deformity, bone defects, limited exposure, and the absence of reliable bony landmarks intraoperatively. With the evolving understanding of RSA biomechanics and the significance of implant configuration and positioning, advancements in preoperative planning and surgical aids have emerged. This review article explores the current evidence on preoperative planning techniques in RSA, including plain radiographs, three-dimensional imaging, computer planning software, intraoperative navigation, and augmented reality (AR), highlighting their potential benefits and advancements in improving implant position accuracy.

11.
Acta ortop. mex ; 36(3): 159-165, may.-jun. 2022. tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1505528

RESUMO

Resumen: Introducción: El estadio final de la artropatía de manguito (AM) genera dolor e invalidez, el tratamiento mediante artroplastía invertida (AI) muestra buenos índices de reducción de dolor y mejoras en movilidad. El objetivo de nuestro trabajo fue evaluar de manera retrospectiva los resultados a mediano plazo de la artroplastía invertida de hombro en nuestro centro. Material y método: Retrospectivamente analizamos 21 pacientes (23 prótesis) sometidos a AI con el diagnóstico de AM. La edad media fue de 75.21 años. El seguimiento mínimo fue de 60 meses. Analizamos las escalas ASES, DASH y CONSTANT preoperatorias y en la última visita de seguimiento. Se analizó la escala VAS preoperatoria y postoperatoria y rango de movilidad preoperatoria y postoperatoria. Resultados: Mejoraron todas las escalas funcionales y dolor (p < 0.001). ASES en 38.91 puntos (IC 95% 30.97-46.84); CONSTANT en 40.89 puntos (IC 95% 34.57-47.21); DASH en 52.65 puntos (IC 95% 46.31-59.0) p < 0.001; y 5.41 puntos (IC 95% 4.31-6.50) en VAS. Mejoraron con significación estadística la flexión (66.52o a 113.91o); y la abducción (63.69o a 105.85o). No obtuvimos significación estadística en rotación externa ni en rotación interna. Aparecieron complicaciones en 14 pacientes; 11 notching glenoideo, una infección crónica, una infección tardía y una fractura intraoperatoria de glenoides. Conclusiones: La AI de hombro representa una alternativa eficaz para el tratamiento de la AM. Puede esperarse alivio del dolor y una mejoría en la flexión y abducción del hombro; la ganancia en rotaciones es poco predecible.


Abstract: Introduction: The final stage of rotator cuff tear arthropathy generates pain and disability, treatment with reverse shoulder arthroplasty shows in different published studies good rates of pain reduction and improvements in mobility. the objective of our study was to retrospectively evaluate the medium-term results of inverted shoulder replacement at our center. Material and methods: Retrospectively, we analyzed 21 patients (23 prosthetics) undergoing reverse shoulder arthroplasty with the diagnosis of rotator cuff tear arthropathy. The average age of patients was 75.21 years The minimum follow-up was 60 months. We analyzed in all preoperative ASES, DASH and CONSTANT patients, and a new functional assessment was made using these same scales at the last follow-up visit. We analyzed pre and postoperative VAS as well as pre and postoperative mobility range. Results: We achieved a statistically significant improvement in all functional scale and pain values (p < 0.001). The ASES scale showed an improvement of 38.91 points (95% CI 30.97-46.84); the 40.89-point CONSTANT scale (95% 34.57-47.21) and the 52.65-point DASH scale (95% 46.31-59.0) p < 0.001. We found an improvement of 5.41 points (95% CI 4.31-6.50) on the VAS scale. We also achieved a statistically significant improvement in flexion values 66.52o to 113.91o degrees; abduction 63.69o to 105.85o degrees at the end of the follow-up. We did not get statistical significance in terms of external rotation but with a tendency to improve in the obtained values; instead in internal rotation we obtained results that showed a tendency to worsen. Complications occurred during follow-up in 14 patients; 11 in relation to notching glenoid, one patient with a chronic infection, one patient with a late infection and one intraoperative fracture of glenoid. Conclusions: Reverse shoulder arthroplasty is an effective treatment of rotator cuff arthropathy. Pain relief and improvement in shoulder flexion and abduction can be expected especially; the gain in rotations is unpredictable.

12.
JSES Rev Rep Tech ; 2(1): 8-16, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37588296

RESUMO

Background: The movement of the arm relative to the trunk results from 3-dimensional (3D) coordinated movements of the glenohumeral (GH) and scapulothoracic (ST) joints and dictates the scapulohumeral rhythm (SHR). Alterations in SHR increase joint overload and may lead to low functional scores, pain, and failures in patients undergoing reverse total shoulder arthroplasty (RSA). The goal of this systematic review and meta-analysis was to examine 3D SHR kinematics after RSA and compare it to that of asymptomatic shoulders. Methods: A systematic review and meta-analysis of articles in English were performed using PubMed, Embase, Cochrane Library, and SciELO. Additional studies were identified by searching bibliographies. Search terms included "Reverse shoulder arthroplasty", "3D", and "scapula". It was selected cross-sectional studies that reported SHR with 3D motion analysis systems in patients who underwent RSA and asymptomatic controls. Two authors independently performed the extraction of articles using predefined data fields, including study quality indicators. Results: Data from four studies were included in quantitative analysis, totaling 48 shoulders with RSA and 63 asymptomatic shoulders. Pooled analyses were based on random-effects model (DerSimonian-Laird). A statistically smaller SHR ratio was observed in the RSA group than that in the control group (P < .00001), meaning a greater contribution of ST joint in relation to GH joint for arm elevation. The standardized mean difference was -1.16 (95% confidence interval: -1.64, -0.67). A sensitivity analysis with three more studies that had imputed data on control group did not change the direction of the effect. The standardized mean difference on sensitivity analysis was -0.60 (P = .03; 95% confidence interval: -1.13, -0.06). It was detected as "not important heterogeneity" within the comparison (I2: 22%). Chi-square was not statistically significant (Chi2: 3.85), and I2 was 22%. Tau2 was not zero (Tau2: 0.05). Sensitivity analysis showed an I2 of 74%, which might represent substantial heterogeneity, Chi-square was not statistically significant (Chi2: 23.01), and Tau2 was not zero (Tau2: 0.37). Conclusion: This study found that RSA shoulders have an increased contribution of ST joint during arm elevation, compared with asymptomatic shoulders. More movement in ST joint in proportion to GH joint increases GH joint contact forces, which could lead to component loosening or other complications. Further studies should address the clinical implications of this kinematic finding.

13.
Acta Ortop Mex ; 36(3): 159-165, 2022.
Artigo em Espanhol | MEDLINE | ID: mdl-36862930

RESUMO

INTRODUCTION: the final stage of rotator cuff tear arthropathy generates pain and disability, treatment with reverse shoulder arthroplasty shows in different published studies good rates of pain reduction and improvements in mobility. the objective of our study was to retrospectively evaluate the medium-term results of inverted shoulder replacement at our center. MATERIAL AND METHODS: retrospectively, we analyzed 21 patients (23 prosthetics) undergoing reverse shoulder arthroplasty with the diagnosis of rotator cuff tear arthropathy. The average age of patients was 75.21 years The minimum follow-up was 60 months. We analyzed in all preoperative ASES, DASH and CONSTANT patients, and a new functional assessment was made using these same scales at the last follow-up visit. We analyzed pre and postoperative VAS as well as pre and postoperative mobility range. RESULTS: we achieved a statistically significant improvement in all functional scale and pain values (p < 0.001). The ASES scale showed an improvement of 38.91 points (95% CI 30.97-46.84); the 40.89-point CONSTANT scale (95% 34.57-47.21) and the 52.65-point DASH scale (95% 46.31-59.0) p < 0.001. We found an improvement of 5.41 points (95% CI 4.31-6.50) on the VAS scale. We also achieved a statistically significant improvement in flexion values 66.52o to 113.91o degrees; abduction 63.69o to 105.85o degrees at the end of the follow-up. We did not get statistical significance in terms of external rotation but with a tendency to improve in the obtained values; instead in internal rotation we obtained results that showed a tendency to worsen. Complications occurred during follow-up in 14 patients; 11 in relation to notching glenoid, one patient with a chronic infection, one patient with a late infection and one intraoperative fracture of glenoid. CONCLUSIONS: reverse shoulder arthroplasty is an effective treatment of rotator cuff arthropathy. Pain relief and improvement in shoulder flexion and abduction can be expected especially; the gain in rotations is unpredictable.


INTRODUCCIÓN: el estadio final de la artropatía de manguito (AM) genera dolor e invalidez, el tratamiento mediante artroplastía invertida (AI) muestra buenos índices de reducción de dolor y mejoras en movilidad. El objetivo de nuestro trabajo fue evaluar de manera retrospectiva los resultados a mediano plazo de la artroplastía invertida de hombro en nuestro centro. MATERIAL Y MÉTODO: retrospectivamente analizamos 21 pacientes (23 prótesis) sometidos a AI con el diagnóstico de AM. La edad media fue de 75.21 años. El seguimiento mínimo fue de 60 meses. Analizamos las escalas ASES, DASH y CONSTANT preoperatorias y en la última visita de seguimiento. Se analizó la escala VAS preoperatoria y postoperatoria y rango de movilidad preoperatoria y postoperatoria. RESULTADOS: mejoraron todas las escalas funcionales y dolor (p < 0.001). ASES en 38.91 puntos (IC 95% 30.97-46.84); CONSTANT en 40.89 puntos (IC 95% 34.57-47.21); DASH en 52.65 puntos (IC 95% 46.31-59.0) p < 0.001; y 5.41 puntos (IC 95% 4.31-6.50) en VAS. Mejoraron con significación estadística la flexión (66.52o a 113.91o); y la abducción (63.69o a 105.85o). No obtuvimos significación estadística en rotación externa ni en rotación interna. Aparecieron complicaciones en 14 pacientes; 11 notching glenoideo, una infección crónica, una infección tardía y una fractura intraoperatoria de glenoides. CONCLUSIONES: la AI de hombro representa una alternativa eficaz para el tratamiento de la AM. Puede esperarse alivio del dolor y una mejoría en la flexión y abducción del hombro; la ganancia en rotaciones es poco predecible.


Assuntos
Artroplastia de Substituição , Artropatia de Ruptura do Manguito Rotador , Idoso , Humanos , Artroplastia de Substituição/métodos , Artropatias/complicações , Artropatias/cirurgia , Dor/etiologia , Estudos Retrospectivos , Artropatia de Ruptura do Manguito Rotador/complicações , Artropatia de Ruptura do Manguito Rotador/cirurgia , Amplitude de Movimento Articular , Avaliação da Deficiência , Recuperação de Função Fisiológica
14.
Acta Ortop Mex ; 35(3): 245-251, 2021.
Artigo em Espanhol | MEDLINE | ID: mdl-34921532

RESUMO

PURPOSE: Compare functional and radiological outcomes of three different designs of reverse shoulder arthroplasty according to distalization and lateralization shoulder angle, in heterogenic diagnostics (fracture, cuff arthropathy, fracture sequela and osteoarthritis). MATERIAL AND METHODS: Prospective cohort of 33 patients of reverse shoulder arthroplasty (RSA) between December 2014 and July 2017 with a minimum one year of follow-up. We defined three groups, G: 10 patients with Grammont (155o, Medialized Glena), B: 9 patients with Bio-RSA (155º, lateralized bone glena) and A: 14 patients with Arrow (135o, lateralized metallic glena). We analyze demographic, clinical, functional and radiological outcomes (lateralization shoulder angle (LSA) and distalization shoulder angle (DSA)). For the statistical analysis, ANOVA, T-tests and linear regression tests were used, with a statistical significance of 5%. RESULTS: The LSA was significantly higher in group A (98o A, 79o G, 80o B) (p < 0.05). In DSA, group B was significantly higher than A (52o B, 39o A) (p < 0.05) and not significant to G (48o G) (p = 0.06). There was no correlation of LSA and DSA with external rotation (p = 0.51) and active elevation (p = 0.41), respectively. There was no significant clinical (anterior elevation, external rotation, internal rotation) and functional outcomes (adjusted Constant score and subjective shoulder evaluation) differences between the different RSA models (p > 0.05). CONCLUSIONS: The LSA was higher in the Arrow and the DSA was higher in Bio-RSA. We did not find Clinical - Radiological correlation in this heterogeneous series of patients.


OBJETIVO: Comparar resultados funcionales e imagenológicos de tres modelos protésicos según el índice de lateralización y distalización. En un grupo heterogéneo de diagnósticos (fractura, artropatía de manguito, secuela de fractura y artrosis glenohumeral). MATERIAL Y MÉTODOS: Cohorte prospectiva de 33 pacientes sometidos a prótesis reversa de hombro entre Diciembre 2014 y Julio 2017 con un seguimiento mínimo de un año. Se definieron tres grupos, G: 10 pacientes con Grammont clásico (155o, Glena medializada); B: nueve pacientes con Bio-RSA (155o, glena lateralizada ósea); y A: 14 con Arrow (135o, glena lateralizada metálica). Las variables fueron: datos demográficos, clínicos, funcionales y radiológicos (ángulo de lateralización y distalización). Para el análisis estadístico se utilizaron pruebas de ANOVA, T-test y regresión lineal, con una significancia estadística de 5%. RESULTADOS: El ángulo de lateralización del hombro (LSA) fue significativamente mayor en el grupo A (98o A, 79o G, 80o B) (p < 0.05). El ángulo de distalización del hombro (DSA) del grupo B fue significativamente superior al A (52o B, 39o A) (p < 0.05) y no significativamente superior al G (48o G) (p = 0.06). No se demostró una correlación entre el LSA y DSA con la rotación externa (p = 0.51) y elevación activa (p = 0.41), respectivamente. En índices clínicos (elevación anterior, rotación externa, rotación interna) y funcionales (índice Constant ajustado y evaluación subjetiva de hombro) no encontramos diferencias significativas entre los distintos modelos protésicos (p > 0.05). CONCLUSIONES: El ángulo de lateralización fue mayor en el modelo Arrow y distalización en el modelo Bio-RSA. No encontramos correlación clínica-radiológica en esta serie heterogénea de pacientes.


Assuntos
Prótese de Ombro , Humanos , Estudos Prospectivos
15.
J Orthop ; 28: 5-9, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34707334

RESUMO

BACKGROUND: Optimal postoperative distalization (DSA) and lateralization (LSA) shoulder angles have been described as radiological measurements correlated with function after reverse shoulder arthroplasty (RSA). The proposed optimal values are DSA between 40° and 65° and LSA between 75° and 95°; however, whether these values can be reached with different implant designs is unclear. AIM: To determine which RSA implant could achieve higher rates of optimal DSA and LSA, to determine any association between each implant and optimal DSA and LSA, and to assess the correlation of the preoperative critical shoulder angle (CSA) and acromial index (AI) with the DSA and LSA. METHODS: This was a retrospective comparative study of all patients who underwent primary RSA for rotator cuff arthropathy. Three RSA implant designs were included, based on which patients were divided into three groups: group 1 (FH Arrow™; 16 patients) comprised onlay implants with a 135° neck-shaft angle (NSA); group 2 (Biomet Comprehensive™; 20 patients) comprised onlay implants with a 147° NSA; group 3 (Mathys Affinis™; 15 patients) comprised inlay implants with a 155° NSA. The AI and CSA were measured on preoperative radiographs. The DSA and LSA were measured on true AP postoperative radiographs. RESULTS: The mean DSAs were 44°, 46°, and 46° (P = 0.671) and the mean LSAs were 92°, 91°, and 82° for groups 1, 2, and 3, respectively (P = 0.003). Group 3 had lower LSA than groups 1 (-10°; P = 0.005) and 2 (-9°; P = 0.002). Optimal DSA and LSA were achieved in 71% and 73% of all arthroplasties, respectively. No association between implant designs and achieving an optimal DSA or LSA was observed. None of the implant designs had DSA >65°. The most common cause of failure to reach an optimal LSA in onlay implants was a combination of LSA >95° and DSA <40°. The most common cause of failure in group 3 was DSA <40°. The DSA was negatively correlated with the AI (-0.384; P = 0.006) and CSA (-0.305; P = 0.033). No correlation was observed between the LSA and AI (P = 0.312) or CSA (P = 0.137). CONCLUSION: The LSA is lower with the Mathys Affinis™ implant than with the Biomet Comprehensive™ and FH Arrow™ implants; however, most LSAs are in the optimal ranges, and no association is observed between different implant designs and optimal DSA and LSA. Implant design, CSA, and AI should be considered during preoperative planning to achieve optimal DSA and LSA.

16.
Acta ortop. mex ; 35(3): 245-251, may.-jun. 2021. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1374178

RESUMO

Resumen: Objetivo: Comparar resultados funcionales e imagenológicos de tres modelos protésicos según el índice de lateralización y distalización. En un grupo heterogéneo de diagnósticos (fractura, artropatía de manguito, secuela de fractura y artrosis glenohumeral). Material y métodos: Cohorte prospectiva de 33 pacientes sometidos a prótesis reversa de hombro entre Diciembre 2014 y Julio 2017 con un seguimiento mínimo de un año. Se definieron tres grupos, G: 10 pacientes con Grammont clásico (155o, Glena medializada); B: nueve pacientes con Bio-RSA (155o, glena lateralizada ósea); y A: 14 con Arrow (135o, glena lateralizada metálica). Las variables fueron: datos demográficos, clínicos, funcionales y radiológicos (ángulo de lateralización y distalización). Para el análisis estadístico se utilizaron pruebas de ANOVA, T-test y regresión lineal, con una significancia estadística de 5%. Resultados: El ángulo de lateralización del hombro (LSA) fue significativamente mayor en el grupo A (98o A, 79o G, 80o B) (p < 0.05). El ángulo de distalización del hombro (DSA) del grupo B fue significativamente superior al A (52o B, 39o A) (p < 0.05) y no significativamente superior al G (48o G) (p = 0.06). No se demostró una correlación entre el LSA y DSA con la rotación externa (p = 0.51) y elevación activa (p = 0.41), respectivamente. En índices clínicos (elevación anterior, rotación externa, rotación interna) y funcionales (índice Constant ajustado y evaluación subjetiva de hombro) no encontramos diferencias significativas entre los distintos modelos protésicos (p > 0.05). Conclusiones: El ángulo de lateralización fue mayor en el modelo Arrow y distalización en el modelo Bio-RSA. No encontramos correlación clínica-radiológica en esta serie heterogénea de pacientes.


Abstract: Purpose: Compare functional and radiological outcomes of three different designs of reverse shoulder arthroplasty according to distalization and lateralization shoulder angle, in heterogenic diagnostics (fracture, cuff arthropathy, fracture sequela and osteoarthritis). Material and methods: Prospective cohort of 33 patients of reverse shoulder arthroplasty (RSA) between December 2014 and July 2017 with a minimum one year of follow-up. We defined three groups, G: 10 patients with Grammont (155o, Medialized Glena), B: 9 patients with Bio-RSA (155º, lateralized bone glena) and A: 14 patients with Arrow (135o, lateralized metallic glena). We analyze demographic, clinical, functional and radiological outcomes (lateralization shoulder angle (LSA) and distalization shoulder angle (DSA)). For the statistical analysis, ANOVA, T-tests and linear regression tests were used, with a statistical significance of 5%. Results: The LSA was significantly higher in group A (98o A, 79o G, 80o B) (p < 0.05). In DSA, group B was significantly higher than A (52o B, 39o A) (p < 0.05) and not significant to G (48o G) (p = 0.06). There was no correlation of LSA and DSA with external rotation (p = 0.51) and active elevation (p = 0.41), respectively. There was no significant clinical (anterior elevation, external rotation, internal rotation) and functional outcomes (adjusted Constant score and subjective shoulder evaluation) differences between the different RSA models (p > 0.05). Conclusions: The LSA was higher in the Arrow and the DSA was higher in Bio-RSA. We did not find Clinical - Radiological correlation in this heterogeneous series of patients.

17.
Rev. Bras. Ortop. (Online) ; 55(6): 748-754, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1156199

RESUMO

Abstract Objective To compare the functional results of patients with complex proximal humerus fracture submitted to total shoulder reverse arthroplasty with and without tuberosity healing. The secondary goal was to know the tuberosity healing rate after reverse shoulder arthroplasty with our surgical technique. Methods A retrospective, cohort type study, with a prospective database collection. In total, 28 patients fulfilled the inclusion criteria: age ≥ 65 years, reverse shoulder arthroplasty for complex proximal humerus fracture (type-3 or -4, according to Neer), and a minimum of 24 months of follow-up. At six months of follow-up, all of the patients were evaluated radiographically for tuberosity, and then they were divided into 2 groups: those with healed tuberosities and those with non-healed tuberosities. A clinical evaluation using the Constant score, active range of motion and the Visual Analog Scale (VAS) at the last follow-up was also performed. Results Tuberosity healing occurred in 21 patients (76.3%). There were statistically significant differences in the Constant scoring system (p < 0.001), forward elevation (p = 0.020), internal rotation (p = 0.001) and external rotation (p = 0.003) when comparing the group of healed tuberosities with the group of non-healed tuberosities. No differences were found regarding the VAS score. Conclusion Tuberosity healing results in an improvement of the functional outcomes of patients submitted to reverse shoulder arthroplasty as a treatment for complex proximal humeral fractures in the elderly.


Resumo Objetivo Comparar os resultados funcionais entre pacientes com fratura complexa do úmero proximal submetidos a artroplastia reversa com tubérculos consolidados e tubérculos não consolidados. O objetivo secundário foi determinar a taxa de consolidação dos tubérculos com este tipo de prótese. Métodos Estudo de tipo coorte, retrospectivo, com coleta prospectiva de dados. No total, 28 pacientes cumpriram os critérios de inclusão: idade superior a 65 anos, prótese reversa do ombro por fratura complexa do úmero proximal (3 ou 4 partes, segundo Neer), e tempo de seguimento mínimo de 24 meses. Aos seis meses, todos os pacientes foram avaliados radiograficamente quanto à consolidação dos tubérculos e divididos em dois grupos: grupo com tubérculos consolidados e grupo com tubérculos não consolidados. A avaliação funcional realizou-se segundo o sistema de pontuação de Constant, da amplitude de movimento ativo, e da Escala Visual Analógica (EVA) à data da última consulta. Registaram-se todas as complicações. Resultados A consolidação dos tubérculos ocorreu em 21 pacientes (76,3%). Verificou-se diferenças estatisticamente significativas no sistema de pontuação de Constant (p < 0.001), elevação anterior (p = 0.020), rotação interna (p = 0.001) e externa (p = 0.003), quando se comparou o grupo dos tubérculos consolidados com o grupo dos tubérculos não consolidados. Não houve diferenças significativas na EVA entre os 2 grupos. Conclusão A consolidação dos tubérculos traduz uma melhoria dos resultados funcionais em pacientes submetidos a artroplastia reversa do ombro como tratamento de fraturas complexas do úmero proximal em idosos.


Assuntos
Humanos , Masculino , Feminino , Idoso , Próteses e Implantes , Rádio (Anatomia) , Fraturas do Ombro , Amplitude de Movimento Articular , Atividade Extraespaçonave , Amplitude de Ondas Sísmicas , Fraturas Ósseas , Artroplastia do Ombro , Úmero , Movimento
18.
J Shoulder Elb Arthroplast ; 3: 2471549219861185, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-34497953

RESUMO

OBJECTIVE: The aim was to establish a correlation between the integrity of a suture made in the subscapular tendon (SST), as assessed by an ultrasound examination, and its functionality, as assessed by clinical tests during the postoperative period following reverse shoulder arthroplasty (RSA). A secondary goal is to evaluate the presence and viability of the sutured SST. METHODS: This is a retrospective study of 18 RSA patients in whom the SST was repositioned to the anterior face of the humeral osteotomy. The median time of the postoperative evaluation was 31 months. The clinical evaluation consisted of the Gerber lift-off test, the internal rotation (IR) lag sign test, and the abdominal compression test, as well as forward flexion (FF), external rotation (ER), and IR. All patients underwent shoulder ultrasounds to evaluate the SST presence and viability. RESULTS: The SST was visualized in 13 patients (72.2%; 95% confidence interval [CI], 51.5-92.9). Of these 13 patients, the SST presented an altered fibrillar pattern in 5 patients (38.4%; 95% CI, 12.0-64.9) and was considered nonviable. There were no associations between SST viability and a positive Gerber's lift-off test (P = .480), a positive IR lag sign test (P = .480), or a positive abdominal compression test (P = .618). There were no significant differences in FF (P = .104), ER (P = .196), or IR (P = .374) mobility between patients with viable SSTs and those without viable SSTs. CONCLUSION: It was not possible to demonstrate a correlation between the integrity of the SST repair based on the ultrasound and its functionality as assessed by clinical tests in the postoperative period following an RSA. The SST repair has a high failure rate, as demonstrated by the high incidence of nonviable or absent tendons.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA