Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.662
Filtrar
1.
Artigo em Inglês | LILACS-Express | LILACS, BNUY | ID: biblio-1573799

RESUMO

The rupture of the anterior cruciate ligament is common during physical activities; however, when associated with a multiple ligament injury, it represents an uncommon condition. The diagnosis of this injury is commonly delayed or missed. Consequently, the incidence of this injury may in fact be higher than reported. We present a case of a 27-year-old man with complete tear of the anterior cruciate ligament and of the medial collateral ligament and partial tear of the posterior cruciate, lateral collateral and patellar ligaments treated surgically.


A ruptura do ligamento cruzado anterior é comum durante atividades físicas; entretanto, quando associada a lesão ligamentar múltipla, representa uma condição incomum. O diagnóstico desta lesão é comumente tardio ou esquecido. Consequentemente, a incidência desta lesão pode de facto ser superior à relatada. Apresentamos o caso de um homem de 27 anos com ruptura completa do ligamento cruzado anterior e do ligamento colateral medial e ruptura parcial dos ligamentos cruzado posterior, colateral lateral e patelar tratados cirurgicamente.


La rotura del ligamento cruzado anterior es común durante las actividades físicas; sin embargo, cuando se asocia con una lesión de múltiples ligamentos, representa una condición poco común. El diagnóstico de esta lesión comúnmente se retrasa o se pasa por alto. En consecuencia, la incidencia de esta lesión puede ser mayor de lo informado. Presentamos el caso de un varón de 27 años con rotura completa del ligamento cruzado anterior y del ligamento colateral medial y rotura parcial de los ligamentos cruzado posterior, colateral lateral y rotuliano tratados quirúrgicamente.

2.
Artigo em Português | LILACS, BNUY, UY-BNMED | ID: biblio-1568769

RESUMO

Apesar de não muito frequente, nos últimos 20 anos, houve um aumento significativo dos relatos sobre rotura do peitoral maior, normalmente associadas à prática de atividade física em que ocorre contração intensa e/ou uso de cargas pesadas exercendo resistência sobre o músculo. Neste relato de caso temos um paciente de 51 anos referindo dor no tórax à direita e no braço direito há 3 dias após tentar consertar o guidão da moto. Apresentava assimetria dos peitorais, perda de força do membro superior direito, dificuldade de movimentação e hematoma. A ressonância magnética demonstrou rotura completa da junção miotendínea do peitoral maior, com tendinopatia com fissuras insercionais e intrasubstanciais infraespinhal e tendinopatia com rotura parcial do tendão subescapular. Foi indicado por médico ortopedista o acompanhamento com o uso de medicação analgésica.


Although not very common, in the last 20 years, there has been a significant increase in reports of rupture of the pectoralis major, normally associated with the practice of physical activity in which intense contraction occurs and/or the use of heavy loads exerting resistance on the muscle. In this case report we have a 51-year-old patient reporting pain in his right chest and right arm for 3 days after trying to fix his motorcycle's handlebars. He had asymmetry of the pectorals, loss of strength in the right upper limb, difficulty moving and hematoma. Magnetic resonance imaging demonstrated complete rupture of the myotendinous junction of the pectoralis major, with tendinopathy with insertional and intrasubstantial infraspinatus fissures and tendinopathy with partial rupture of the subscapularis tendon. An orthopedic doctor recommended follow-up with the use of analgesic medication.


Aunque no es muy común, en los últimos 20 años se ha observado un aumento significativo en los reportes de rotura del pectoral mayor, normalmente asociado a la práctica de actividad física en la que se produce una contracción intensa y/o al uso de cargas pesadas ejerciendo resistencia sobre el mismo. el músculo. En este caso clínico tenemos un paciente de 51 años que refiere dolor en el pecho derecho y en el brazo derecho durante 3 días después de intentar arreglar el manillar de su motocicleta. Presentó asimetría de pectorales, pérdida de fuerza en miembro superior derecho, dificultad de movimiento y hematoma. La resonancia magnética demostró rotura completa de la unión miotendinosa del pectoral mayor, con tendinopatía con fisuras de inserción e intrasustancial del infraespinoso y tendinopatía con rotura parcial del tendón subescapular. Un médico ortopédico recomendó seguimiento con el uso de medicación analgésica.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Músculos Peitorais/lesões , Músculos Peitorais/diagnóstico por imagem , Extremidade Superior/lesões , Extremidade Superior/diagnóstico por imagem , Junção Miotendínea/lesões , Junção Miotendínea/diagnóstico por imagem
3.
Appl Spectrosc ; : 37028241267938, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39094005

RESUMO

This study investigates the combined effects of nanoscale surface roughness and electron-phonon interaction on the vibrational modes of cadmium telluride (CdTe) using resonant Raman spectroscopy. Raman spectra simulations aided in identifying the active phonon modes and their dependence on roughness. Our results reveal that increasing surface roughness leads to an asymmetric line shape in the first-order longitudinal optical (1LO) phonon mode, attributed to an increase in the electron-phonon interaction. This asymmetry broadens the entire Raman spectrum. Conversely, the overtone (second-order longitudinal optical [2LO]) mode exhibits a symmetrical line shape that intensifies with roughness. Additionally, we identify and discuss the contributions of surface optical phonon mode and multiphonon modes to the Raman spectra, highlighting their dependence on roughness. This work offers a deeper understanding of how surface roughness and electron-phonon scattering influence the line shape of CdTe resonant Raman spectra, providing valuable insights into its vibrational properties.

4.
Radiol Case Rep ; 19(10): 4151-4157, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39101025

RESUMO

Intraventricular neurocytoma is a low incidence central nervous system tumor. It predominantly affects young adults with no apparent gender predilection. The main symptoms include headache, nausea and vomiting. These result from hydrocephalus due to the obstruction of cerebrospinal fluid flow. On diagnostic imaging, neurocytoma can be suspected by some features, such as peripheral cysts, lobulated contours and septa that bridge the ventricular wall, giving a "scalloped" appearance. There are other characteristics, but they are less specific for the diagnosis. The atypical variant of neurocytoma is even rarer and leads to a worst prognosis. Atypical neurocytomas develop higher proliferative potential identified by the Ki-67 biomarker and higher recurrence rate. There are few studies about the imaging characteristics of atypical neurocytomas. At this point, there are no reliable distinctive features to differentiate atypical neurocytomas, especially due to their low incidence. We present the case of a 20-year-old female patient with symptoms of intracraneal hypertension. CT and MRI of the brain revealed a mass occupying the body of the left lateral ventricle, adjacent to the foramen of Monro. The mass was primarily solid with discrete peripheral cyst and a few scalloped areas. It also showed signs of supratentorial obstructive hydrocephalus. The tumor was partially removed because of bleeding and compromise of vascular structures. Immunohistochemistry revealed positive synaptophysin, elevated Ki-67 (7%), increased number of blood vessels and moderate nuclear atypia. After surgery, the patient persisted with signs of intracranial hypertension, not improving with clinical management and requiring aggressive surgical procedures. While rare, atypical neurocytoma requires a better characterization, especially through imaging, to optimize immediate management and explore new therapeutic options.

5.
J Med Phys ; 49(2): 189-202, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39131437

RESUMO

Purpose: This paper explores different machine learning (ML) algorithms for analyzing diffusion nuclear magnetic resonance imaging (dMRI) models when analytical fitting shows restrictions. It reviews various ML techniques for dMRI analysis and evaluates their performance on different b-values range datasets, comparing them with analytical methods. Materials and Methods: After standard fitting for reference, four sets of diffusion-weighted nuclear magnetic resonance images were used to train/test various ML algorithms for prediction of diffusion coefficient (D), pseudo-diffusion coefficient (D*), perfusion fraction (f), and kurtosis (K). ML classification algorithms, including extra-tree classifier (ETC), logistic regression, C-support vector, extra-gradient boost, and multilayer perceptron (MLP), were used to determine the existence of diffusion parameters (D, D*, f, and K) within single voxels. Regression algorithms, including linear regression, polynomial regression, ridge, lasso, random forest (RF), elastic-net, and support-vector machines, were used to estimate the value of the diffusion parameters. Performance was evaluated using accuracy (ACC), area under the curve (AUC) tests, and cross-validation root mean square error (RMSECV). Computational timing was also assessed. Results: ETC and MLP were the best classifiers, with 94.1% and 91.7%, respectively, for the ACC test and 98.7% and 96.3% for the AUC test. For parameter estimation, RF algorithm yielded the most accurate results The RMSECV percentages were: 8.39% for D, 3.57% for D*, 4.52% for f, and 3.53% for K. After the training phase, the ML methods demonstrated a substantial decrease in computational time, being approximately 232 times faster than the conventional methods. Conclusions: The findings suggest that ML algorithms can enhance the efficiency of dMRI model analysis and offer new perspectives on the microstructural and functional organization of biological tissues. This paper also discusses the limitations and future directions of ML-based dMRI analysis.

6.
Neuroophthalmology ; 48(5): 348-351, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39145323

RESUMO

Arachnoid cysts (ACs) are cerebrospinal fluid collections between the two layers of the normal arachnoid membrane. Although they are often asymptomatic with a stationary course, eventual complications may occur. Herein, we report the case of a 9-year-old boy who developed bilateral papilloedema secondary to spontaneous rupture of an AC in the left middle cranial fossa. Although the papilloedema worsened during follow-up, his visual field remained bilaterally stable, supporting the expectant management and obviating the potential morbidity associated with neurosurgical intervention. This case report highlights the importance of a multidisciplinary approach to patients with secondary intracranial hypertension, including serial ophthalmological examinations, which provide a useful guide to surgical decision-making.

7.
Biomed Phys Eng Express ; 10(5)2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39111326

RESUMO

Purpose. To evaluate the feasibility of use of an 1.5 T magnetic resonance (MR)-linear accelerator MR-linac for imaging in gynaecologic high-dose-rate (HDR) brachytherapy.Method. Commissioning measurements for MR images quality control, geometric distortion, dwell position accuracy, applicator reconstruction and end-to-end test for a tandem-and-ring applicator were performed following the recommendations of American Brachytherapy Society, International Commission on Radiation Units and Measurements and Report of the Brachytherapy Working Group of the Spanish Society of Medical Physics. The values for MR-based IGABT were compared to the corresponding values with computed tomography (CT).Results. Measured distorsions for the MR images were less than 0.50 mm compared to the CT images. The differences between 3D displacements for all dwell positions were 0.66 mm and 0.62 mm for the tandem and ring, respectively. The maximum difference is 0.64 mm for the distances from the applicator tip obtained using the films. The CT and MR dose differences for the right and left 'A' points were 0.9% and -0.7%, respectively. Similar results were observed in terms of dose distribution for CT and Mr The gamma passing rate was 99.3% and 99.5%, respectively.Conclusion. The use of MR images from an MR-linac used in a radiotherapy service for gynaecological brachytherapy was proved to be feasible, safe and precise as the geometrical differences were less than 1 mm, and the dosimetric differences were less than 1% when comparing to the use of CT images for the same purpose.


Assuntos
Braquiterapia , Imageamento por Ressonância Magnética , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem , Tomografia Computadorizada por Raios X , Braquiterapia/métodos , Humanos , Feminino , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Radioterapia Guiada por Imagem/métodos , Aceleradores de Partículas , Neoplasias dos Genitais Femininos/radioterapia , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Imagens de Fantasmas , Estudos de Viabilidade
8.
Int Braz J Urol ; 50(5): 595-604, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39106115

RESUMO

PURPOSE: To validate the Barcelona magnetic resonance imaging predictive model (BCN-MRI PM) in men with pre-biopsy multiparametric MRI (mpMRI) reported with the Prostate Imaging Reporting and Data System (PI-RADS) v2.1, followed by transrectal and transperineal prostate biopsies. MATERIALS AND METHODS: Prospective analysis of 3,264 men with PSA >3.0 ng/mL and/or abnormal digital rectal examination who were referred to ten participant centers in the csPCa early detection program of Catalonia (Spain), between 2021 and 2023. MpMRI was reported with the PI-RADS v2.1, and 2- to 4-core MRI-transrectal ultrasound (TRUS) fusion-targeted biopsy of suspected lesions and/or 12-core systematic biopsy were conducted. 2,295 (70.3%) individuals were referred to six centers for transrectal prostate biopsies, while 969 (39.7%) were referred to four centers for transperineal prostate biopsies. CsPCa was classified whenever the International Society of Urologic Pathology grade group was 2 or higher. RESULTS: CsPCa was detected in 41% of transrectal prostate biopsies and in 45.9% of transperineal prostate biopsies (p < 0.016). Both BCN-MRI PM calibration curves were within the ideal correlation between predicted and observed csPCa. Areas under the curve and 95% confidence intervals were 0.847 (0.830-0.857) and 0.830 (0.823-0.855), respectively (p = 0.346). Specificities corresponding to 95% sensitivity were 37.6 and 36.8%, respectively (p = 0.387). The Net benefit of the BCN-MRI PM was similar with both biopsy methods. CONCLUSIONS: The BCN-MRI PM has been successfully validated when mpMRI was reported with the PI-RADS v2.1 and prostate biopsies were conducted via the transrectal and transperineal route.


Assuntos
Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética Multiparamétrica , Próstata , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Estudos Prospectivos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Idoso , Pessoa de Meia-Idade , Próstata/patologia , Próstata/diagnóstico por imagem , Períneo/diagnóstico por imagem , Períneo/patologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos
9.
Sensors (Basel) ; 24(15)2024 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-39124094

RESUMO

Graphene-based surface plasmon resonance (SPR) biosensors have emerged as a promising technology for the highly sensitive and accurate detection of biomolecules. This study presents a comprehensive theoretical analysis of graphene-based SPR biosensors, focusing on configurations with single and bimetallic metallic layers. In this study, we investigated the impact of various metallic substrates, including gold and silver, and the number of graphene layers on key performance metrics: sensitivity of detection, detection accuracy, and quality factor. Our findings reveal that configurations with graphene first supported on gold exhibit superior performance, with sensitivity of detection enhancements up to 30% for ten graphene layers. In contrast, silver-supported configurations, while demonstrating high sensitivity, face challenges in maintaining detection accuracy. Additionally, reducing the thickness of metallic layers by 30% optimizes light coupling and enhances sensor performance. These insights highlight the significant potential of graphene-based SPR biosensors in achieving high sensitivity of detection and reliability, paving the way for their application in diverse biosensing technologies. Our findings pretend to motivate future research focusing on optimizing metallic layer thickness, improving the stability of silver-supported configurations, and experimentally validating the theoretical findings to further advance the development of high-performance SPR biosensors.


Assuntos
Técnicas Biossensoriais , Ouro , Grafite , Prata , Ressonância de Plasmônio de Superfície , Grafite/química , Ressonância de Plasmônio de Superfície/métodos , Prata/química , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Ouro/química
10.
Nanotechnology ; 35(46)2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39116890

RESUMO

The translation of silver-based nanotechnology 'from bench to bedside' requires a deep understanding of the molecular aspects of its biological action, which remains controversial at low concentrations and non-spherical morphologies. Here, we present a hemocompatibility approach based on the effect of the distinctive electronic charge distribution in silver nanoparticles (nanosilver) on blood components. According to spectroscopic, volumetric, microscopic, dynamic light scattering measurements, pro-coagulant activity tests, and cellular inspection, we determine that at extremely low nanosilver concentrations (0.125-2.5µg ml-1), there is a relevant interaction effect on the serum albumin and red blood cells (RBCs). This explanation has its origin in the surface charge distribution of nanosilver particles and their electron-mediated energy transfer mechanism. Prism-shaped nanoparticles, with anisotropic charge distributions, act at the surface level, generating a compaction of the native protein molecule. In contrast, the spherical nanosilver particle, by exhibiting isotropic surface charge, generates a polar environment comparable to the solvent. Both morphologies induce aggregation at NPs/bovine serum albumin ≈ 0.044 molar ratio values without altering the coagulation cascade tests; however, the spherical-shaped nanosilver exerts a negative impact on RBCs. Overall, our results suggest that the electron distributions of nanosilver particles, even at extremely low concentrations, are a critical factor influencing the molecular structure of blood proteins' and RBCs' membranes. Isotropic forms of nanosilver should be considered with caution, as they are not always the least harmful.


Assuntos
Eritrócitos , Nanopartículas Metálicas , Soroalbumina Bovina , Prata , Prata/química , Nanopartículas Metálicas/química , Eritrócitos/metabolismo , Eritrócitos/química , Humanos , Soroalbumina Bovina/química , Soroalbumina Bovina/metabolismo , Propriedades de Superfície , Animais , Bovinos , Coagulação Sanguínea/efeitos dos fármacos , Proteínas Sanguíneas/metabolismo , Proteínas Sanguíneas/química , Teste de Materiais
11.
Alzheimers Dement ; 20(9): 5912-5925, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39136296

RESUMO

BACKGROUND: Education influences brain health and dementia. However, its impact across regions, specifically Latin America (LA) and the United States (US), is unknown. METHODS: A total of 1412 participants comprising controls, patients with Alzheimer's disease (AD), and frontotemporal lobar degeneration (FTLD) from LA and the US were included. We studied the association of education with brain volume and functional connectivity while controlling for imaging quality and variability, age, sex, total intracranial volume (TIV), and recording type. RESULTS: Education influenced brain measures, explaining 24%-98% of the geographical differences. The educational disparities between LA and the US were associated with gray matter volume and connectivity variations, especially in LA and AD patients. Education emerged as a critical factor in classifying aging and dementia across regions. DISCUSSION: The results underscore the impact of education on brain structure and function in LA, highlighting the importance of incorporating educational factors into diagnosing, care, and prevention, and emphasizing the need for global diversity in research. HIGHLIGHTS: Lower education was linked to reduced brain volume and connectivity in healthy controls (HCs), Alzheimer's disease (AD), and frontotemporal lobar degeneration (FTLD). Latin American cohorts have lower educational levels compared to the those in the United States. Educational disparities majorly drive brain health differences between regions. Educational differences were significant in both conditions, but more in AD than FTLD. Education stands as a critical factor in classifying aging and dementia across regions.


Assuntos
Doença de Alzheimer , Encéfalo , Escolaridade , Imageamento por Ressonância Magnética , Humanos , América Latina , Masculino , Feminino , Estados Unidos , Encéfalo/patologia , Encéfalo/diagnóstico por imagem , Idoso , Doença de Alzheimer/patologia , Pessoa de Meia-Idade , Degeneração Lobar Frontotemporal/patologia , Demência/patologia , Demência/epidemiologia
12.
Radiol Med ; 129(10): 1431-1443, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39106024

RESUMO

PURPOSE: There is an unmet clinical need for non-invasive imaging biomarkers that could replace liver biopsy in the management of patients with autoimmune hepatitis (AIH). In this study, we sought to evaluate the diagnostic accuracy of a simple uncorrected, non-contrast T1 mapping for detecting fibrosis and inflammation in AIH patients using histopathology as a reference standard. MATERIAL AND METHODS: Over 3 years, 33 patients with AIH were prospectively studied using a multiparametric liver MRI protocol which included T1 mapping. Biopsies were performed up to 3 months before imaging, and a standardized histopathological score for fibrosis (F0-F4) and inflammatory activity (PPA0-4) was used as a reference. Statistical analysis included independent t test, Mann-Whitney U-test, and ROC (receiver operating characteristic) analysis. RESULTS: T1 mapping values were significantly higher in patients with advanced fibrosis (F0-2 vs. F3-4; p < 0.015), significant fibrosis (F0-1 vs. F2-4; p < 0.005), and significant inflammatory activity (PPA 0-1 vs. PPA 2-4 p = 0.048). Moreover, the technique demonstrated a good diagnostic performance in detecting significant (AUC 0.856) and advanced fibrosis (AUC 0.835), as well as significant inflammatory activity (AUC 0.763). CONCLUSION: A rapid, simple, uncorrected, non-contrast T1 mapping sequence showed satisfactory diagnostic performance in comparison with histopathology for detecting significant tissue inflammation and fibrosis in AIH patients, being a potential non-invasive imaging biomarker for monitoring disease activity in such individuals.


Assuntos
Hepatite Autoimune , Cirrose Hepática , Imageamento por Ressonância Magnética , Humanos , Hepatite Autoimune/diagnóstico por imagem , Hepatite Autoimune/patologia , Estudos Prospectivos , Feminino , Masculino , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Biópsia , Padrões de Referência , Inflamação/diagnóstico por imagem
13.
Diabetol Metab Syndr ; 16(1): 156, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38982515

RESUMO

BACKGROUND: This study investigates myocardial structural changes in stable coronary artery disease (CAD) patients with type 2 diabetes (T2D) using cardiac magnetic resonance (CMR) strain and T1 mapping. METHODS: A total of 155 stable CAD patients underwent CMR examination, including left ventricular (LV) morphology and function assessment, late gadolinium enhancement (LGE), and feature tracking (CMR-FT) for LV global longitudinal, circumferential, and radial strain. T1 mapping with extracellular volume (ECV) evaluation was also performed. RESULTS: Among the enrolled patients, 67 had T2D. Diabetic patients exhibited impaired LV strain and higher ECV compared to non-diabetics. Multivariate analysis identified T2D as an independent predictor of increased ECV and decreased strain. CONCLUSIONS: CMR-based strain and T1 mapping highlighted impaired myocardial contractility, elevated ECV, and potential interstitial fibrosis in diabetic patients with stable CAD. This suggests a significant impact of diabetes on myocardial health beyond CAD, emphasizing the importance of a comprehensive assessment in these individuals. TRIAL REGISTRATION: http://www.controlled-trials.com/ISRCTN09454308.

14.
JACC Case Rep ; 29(14): 102386, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38988439

RESUMO

Chylopericardium is a rare complication after cardiac transplantation. We report a case of a 69-year-old woman with persistent chylopericardium after a heart transplantation due to Chagas disease. Failure of conservative treatment led to dynamic contrast-enhanced magnetic resonance lymphangiography and percutaneous radiologic intervention of the lymphatic leakage and symptoms resolution.

15.
Mycoses ; 67(7): e13767, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39004801

RESUMO

BACKGROUND: The radiological manifestations of central nervous system (CNS) cryptococcosis are diverse and often subtle. There is heterogeneity on how different neuroimaging patterns impact prognosis. This study aims to assess the association between the neuroimaging and clinical outcomes of CNS cryptococcosis. METHODS: All patients with CNS cryptococcosis between July 2017 and April 2023 who underwent brain magnetic resonance imaging (MRI) were included. The primary outcome was mortality during hospitalisation. Secondary outcomes were readmission, ventricular shunting, duration of hospitalisation and time to the first negative cerebrospinal fluid culture. We compared the outcomes for each of the five main radiological findings on the brain MRI scan. RESULTS: We included 46 proven CNS cryptococcosis cases. The two main comorbidity groups were HIV infection (20, 43%) and solid organ transplantation (10, 22%), respectively. Thirty-nine patients exhibited at least one radiological abnormality (85%), with the most common being meningeal enhancement (34, 74%). The mortality rates occurred at 11% (5/46) during hospitalisation. We found no significant disparities in mortality related to distinct radiological patterns. The presence of pseudocysts was significantly associated with the need for readmission (p = .027). The ventricular shunting was significantly associated with the presence of pseudocysts (p = .005) and hydrocephalus (p = .044). CONCLUSION: In this study, there is no association between brain MRI findings and mortality. Larger studies are needed to evaluate this important issue.


Assuntos
Criptococose , Imageamento por Ressonância Magnética , Neuroimagem , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Neuroimagem/métodos , Criptococose/diagnóstico por imagem , Criptococose/mortalidade , Criptococose/microbiologia , Adulto , Idoso , Estudos Retrospectivos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Infecções Fúngicas do Sistema Nervoso Central/diagnóstico por imagem , Infecções Fúngicas do Sistema Nervoso Central/mortalidade , Infecções Fúngicas do Sistema Nervoso Central/microbiologia , Prognóstico , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/mortalidade , Hospitalização , Infecções por HIV/complicações
16.
Rev Cient Odontol (Lima) ; 12(1): e190, 2024.
Artigo em Espanhol | MEDLINE | ID: mdl-39015308

RESUMO

Partial or total perforation of the articular disc is mainly observed in the final stage of temporomandibular disorder. Magnetic resonance imaging (MRI) is considered the gold standard for the diagnosis of joint pathologies; MRI arthrography consists of the infiltration of a contrast medium into a joint, being Gadolinium chelates the most employed medium, however, possible harmful effects have been associated with its use. The aim of this work was to evaluate a case of perforation of the articular disc of the temporomandibular joint by MRI arthrography using physiological solution (NaCl 0.9%) as contrast medium. MR images were obtained with a STIR (Short Tau Inversion Recovery) weighted pulse sequence in the sagittal and coronal planes at maximum mouth opening, after the injection of the physiological solution in the superior articular space. The communication of both articular spaces was identified, observing a greater filling in the inferior articular space, as well as the latero-medial displacement of the disc segments. Arthrography with physiological solution allowed the precise diagnosis of the perforation, which made it possible to guide the treatment plan, reducing diagnostic and surgical times, also considering the reduction of complications and adverse effects related to other contrast media, added to the benefit of the reduction of the cost of the exam.

17.
Rev Bras Ortop (Sao Paulo) ; 59(Suppl 1): e60-e64, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39027163

RESUMO

Osteolipoma is a rare benign variant of lipoma and constitutes less than 1% of all lipomas, presenting as a well-circumscribed painless mass. It is a tumor known to occur in several regions, usually intraosseous or adjacent to bone tissue, whose pathogenesis is still unclear. Imaging exams are useful in their evaluation and, mainly, in surgical planning, which consists of tumor excision. However, the definitive diagnosis of osteolipoma is made by histopathological examination. Although benign, osteolipomas can compress surrounding structures, leading to important symptomatology, as in this case reported in which it is in contact with the brachial plexus.

18.
Skeletal Radiol ; 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39080031

RESUMO

OBJECTIVE: To detail the neurovascular crossing patterns between the leash of Henry (LoH) and the deep branch of the radial nerve (DBRN) in supination and pronation of the forearm, using imaging methods with anatomic correlation. MATERIALS AND METHODS: This cross-sectional study was performed ex vivo with HRUS and MRI with anatomic correlation on 6 samples and in vivo with HRUS with Doppler on 55 participants scanned bilaterally. The in vivo participants were enrolled over a 6-month period. The crossing patterns between the LoH and DBRN were assessed ex vivo and in vivo. Additional morphological features of the DBRN, LoH, and fat plane were assessed in vivo only. Biometric features of the participants were recorded. Statistical analyses were performed using Shapiro-Wilk, parametric and non-parametric tests. RESULTS: The most common neurovascular crossing pattern was the ascending branch of the radial recurrent artery (RRAab) crossing below (ex vivo: 83.3%, in vivo: 85.3%) and the muscular branch crossing above (ex vivo: 100%, in vivo: 63.2% %) the DBRN. Both the deep and superficial surfaces of the DBRN exhibited an intimate relationship with the vessels of the LoH. A positive correlation between vessel diameter and anthropometric factors was observed. In addition, the muscular branch exhibited a significantly smaller diameter than the RRAab. CONCLUSION: Our study detailed the relationship between the LoH and the DBRN and highlighted the high incidence of vessel crossing above the DBRN at the level of the muscular branch. Knowledge of neurovascular crossings is crucial for understanding neurovascular entrapment syndromes and planning interventional procedures to reduce vascular complications.

19.
Microorganisms ; 12(7)2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39065192

RESUMO

Brain abscesses in ruminants often arise from primary infection foci, leading to an unfavorable prognosis for affected animals. This highlights the need for comprehensive studies on brain abscesses across different ruminant species. We retrospectively investigated medical records of epidemiological, clinical, neuroimaging, anatomopathological, and bacteriological findings in six ruminants (three goats, two cows, and one sheep) diagnosed with brain abscesses. All animals studied were female. Apathy (50%), compulsive walking (33%), decreased facial sensitivity (33%), head pressing (33%), seizures (33%), semicomatous mental status (33%), strabismus (33%), unilateral blindness (33%), and circling (33%) represented the most common neurologic signs. Leukocytosis and neutrophilia were the main findings in the hematological evaluation. Cerebrospinal fluid (CSF) analysis revealed predominant hyperproteinorrachia and pleocytosis. In three cases, computed tomography or magnetic resonance imaging were used, enabling the identification of typical abscess lesions, which were subsequently confirmed during postmortem examination. Microbiological culture of the abscess samples and/or CSF revealed bacterial coinfections in most cases. Advanced imaging examinations, combined with CSF analysis, can aid in diagnosis, although confirmation typically relies on postmortem evaluation and isolation of the causative agent. This study contributes to clinicopathological aspects, neuroimages, and bacteriological diagnosis of brain abscesses in domestic ruminants.

20.
Sensors (Basel) ; 24(14)2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39066066

RESUMO

This work explores the transformative role of graphene in enhancing the performance of surface plasmon resonance (SPR)-based biosensors. The motivation for this review stems from the growing interest in the unique properties of graphene, such as high surface area, excellent electrical conductivity, and versatile functionalization capabilities, which offer significant potential to improve the sensitivity, specificity, and stability of SPR biosensors. This review systematically analyzes studies published between 2010 and 2023, covering key metrics of biosensor performance. The findings reveal that the integration of graphene consistently enhances sensitivity. Specificity, although less frequently reported numerically, showed promising results, with high specificity achieved at sub-nanomolar concentrations. Stability enhancements are also significant, attributed to the protective properties of graphene and improved biomolecule adsorption. Future research should focus on mechanistic insights, optimization of integration techniques, practical application testing, scalable fabrication methods, and comprehensive comparative studies. Our findings provide a foundation for future research, aiming to further optimize and harness the unique physical properties of graphene to meet the demands of sensitive, specific, stable, and rapid biosensing in various practical applications.


Assuntos
Técnicas Biossensoriais , Grafite , Ressonância de Plasmônio de Superfície , Ressonância de Plasmônio de Superfície/métodos , Grafite/química , Técnicas Biossensoriais/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA