Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 286
Filtrar
1.
Restor Dent Endod ; 49(2): e18, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38841382

RESUMO

Objectives: This study was conducted to evaluate the mechanical properties of relined and non-relined fiberglass posts when cemented to root canal dentin using a conventional dual-cure resin cement or a self-adhesive resin cement. Materials and Methods: Two types of resin cements were utilized: conventional and self-adhesive. Additionally, 2 cementation protocols were employed, involving relined and non-relined fiberglass posts. In total, 72 bovine incisors were cemented and subjected to push-out bond strength testing (n = 10) followed by failure mode analysis. The cross-sectional microhardness (n = 5) was assessed along the root canal, and interface analyses (n = 3) were conducted using scanning electron microscopy (SEM). Data from the push-out bond strength and cross-sectional microhardness tests were analyzed via 3-way analysis of variance and the Bonferroni post-hoc test (α = 0.05). Results: For non-relined fiberglass posts, conventional resin cement exhibited higher push-out bond strength than self-adhesive cement. Relined fiberglass posts yielded comparable results between the resin cements. Type II failure was the most common failure mode for both resin cements, regardless of cementation protocol. The use of relined fiberglass posts improved the cross-sectional microhardness values for both cements. SEM images revealed voids and bubbles in the incisors with non-relined fiberglass posts. Conclusions: Mechanical properties were impacted by the cementation protocol. Relined fiberglass posts presented the highest push-out bond strength and cross-sectional microhardness values, regardless of the resin cement used (conventional dual-cure or self-adhesive). Conversely, for non-relined fiberglass posts, the conventional dual-cure resin cement yielded superior results to the self-adhesive resin cement.

2.
Eur J Prosthodont Restor Dent ; 32(1): 28-44, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-37463022

RESUMO

INTRODUCTION: This systematic review examined the effect of neutralizing agents on bond strength after irrigation with sodium hypochlorite and their existing protocols in literature. METHODS: This present study adhered to the PRISMA guidelines and was registered at PROSPERO. Five electronic databases were searched (sept-2020/jan-2021) in English, Spanish, and Portuguese, without any restrictions on publication date. Cases reports, editorials and literature reviews were not included. The risk of bias was assessed using the Cochrane Collaboration tool. From the initial 7,147 studies, 2,745 were removed as duplicates and 4,382 were excluded after a title/abstract screen. RESULTS: Seventeen in vitro studies were included. The results showed that the higher the concentration of sodium hypochlorite, the lower the bond strength at dentine/restoration interface (p⟨0.01). Among the studies, sodium ascorbate was the most widely used neutralizer and showed the most significant results in increasing bond strength (p⟨0.01). The bond strength values were found to increase with longer application time of the neutralizing substances (p⟨0.01). CONCLUSIONS: The use of sodium ascorbate as a neutralizing agent can reverse the negative effects of the sodium hypochlorite and improve the bond strength between dentine and resin cement, however, it isn't possible to determine the best protocol for use.


Assuntos
Colagem Dentária , Hipoclorito de Sódio/química , Hipoclorito de Sódio/farmacologia , Cimentos de Resina/química , Ácido Ascórbico/química , Ácido Ascórbico/farmacologia , Dentina , Teste de Materiais
3.
Eur J Prosthodont Restor Dent ; 32(1): 83-90, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-37814894

RESUMO

INTRODUCTION: The degree of conversion (DC) of resin cements can be affected by ceramics, and by the type of resin cement. The purpose was to evaluate the influence of thickness and translucencies of lithium disilicate ceramic on the DC of resin cements: two light-cure (Variolink LC; NX3 LC) and one dual-cure (NX3 Dual). METHODS: IPS e.max Press ceramic (A2) discs were prepared in 4 thicknesses (0.3, 0.5, 1.0, and 1.5 mm) and in 3 translucencies: HT (high translucency), LT (low translucency), and MO (medium opacity). Subsequently, 234 samples of resin cement (5 x 1 mm) were light-cured through those ceramic discs. The DC was assessed by Fourier Transform Infrared Spectroscopy (FTIR). RESULTS: Ceramic thicknesses decreased DC of NX3 Dual through HT-1.0 and HT 1.5 (p=0.005). Between translucencies, only MO-0.3 affected Variolink LC DC (p=0.018). There was difference among light- and dual-cured resin cements (p=0.001). CONCLUSION: Increasing thickness and opacity lead to a decrease in the DC of all resin cements, with a significantly lower DC value in NX3 Dual (HT-1.0; HT-1.5), and in Variolink LC (MO- 0.3). Light- and dual-cured resin cements were different among each other. NX3 Dual achieved a significantly lower value than its counterpart NX3 LC.


Assuntos
Porcelana Dentária , Cimentos de Resina , Cimentos de Resina/química , Teste de Materiais , Porcelana Dentária/química , Cerâmica/química , Espectroscopia de Infravermelho com Transformada de Fourier
4.
Braz. dent. j ; Braz. dent. j;35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1564090

RESUMO

Abstract This study aimed to evaluate the bond strength between relined fiberglass posts with different composite resin opacities in different thirds of the intraradicular dentin. Thirty single-rooted premolars were endodontically treated and divided into three groups (n=10): fiberglass posts relined with translucent composite resin, fiberglass posts relined with opaque composite resin, and fiberglass posts without relining. After cementation of the posts, the specimens were cut perpendicular to the long axis of the tooth in slices of approximately 1.3 mm of each third to be analyzed (cervical, middle, and apical) and then subjected to the push-out test. The bond strength (MPa) data were subjected to Shapiro-Wilk normality tests and two-way repeated measures analysis of variance, considering the experimental groups and different regions as study factors. Tukey's post-hoc test (p<.05) was applied for comparisons between the groups. In the cervical third, higher values of bond strength were found for the group relined with translucent resin, with a statistically significant difference for the other groups. In the other regions, both opaque and translucent resins showed similar results, but both showed higher values of bond strength compared to fiberglass posts without relining. The bond strength of fiberglass posts to different thirds of intraradicular dentin is influenced by composite resin relining as well as the opacity of the resin. The use of translucent composite resin is a more effective alternative for fiberglass posts relining.


Resumo Este estudo teve como objetivo avaliar a resistência de união entre pinos de fibra de vidro anatomizados com resinas compostas de diferentes opacidades em diferentes terços da dentina intrarradicular. Trinta pré-molares uniradiculares foram tratados endodonticamente e divididos em três grupos (n=10): pinos de fibra de vidro anatomizados com resina composta translúcida, pinos de fibra de vidro anatomizados com resina composta opaca e pinos de fibra de vidro sem anatomização. Após a cimentação dos pinos, os corpos de prova foram cortados perpendicularmente ao longo eixo do dente em fatias de aproximadamente 1,3 mm de cada terço a ser analisado (cervical, médio e apical) e posteriormente submetidos ao teste de push-out. Os dados de resistência de união (MPa) foram submetidos a testes de normalidade de Shapiro-Wilk e ANOVA dois fatores para análises repetidas, considerando os grupos experimentais e diferentes regiões como fatores de estudo. O teste post-hoc de Tukey (p=0,05) foi aplicado para comparações entre os grupos. No terço cervical foram encontrados maiores valores de resistência de união no grupo com anatomização com resina translúcida, com diferença estatisticamente significativa para os demais grupos. Nas demais regiões, tanto as resinas opacas quanto as translúcidas apresentaram resultados semelhantes, mas ambas apresentaram valores de resistência de união superiores aos pinos de fibra de vidro sem anatomização. A resistência de união dos pinos de fibra de vidro aos diferentes terços da dentina intrarradicular é influenciada pela anatomização da resina composta, bem como pela opacidade da resina. A utilização de resina composta translúcida é uma alternativa mais eficaz para a anatomização de pinos de fibra de vidro.

5.
Aust Dent J ; 2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37888911

RESUMO

BACKGROUND: Medium-term evaluate the bond strength and tag formation in root dentin using self-adhesive cements Maxcem Elite (MCE), Relyx U200 (RU2), SeT PP (SPP) and Megalink (MGL) compared to conventional cement Relyx ARC (ARC) for glass fibre post cementation. MATERIALS AND METHODS: One hundred bovine incisors roots were endodontically treated and divided into 5 groups (n = 20) according to the cementation system: MCE, RU2, SPP, MGL and ARC. All cementation systems were evaluated at 24 h (1) and 12 months (2) after post cementation. Specimens from the cervical, middle and apical thirds of the root were submitted to push-out bond strength test and confocal laser microscopy to verify the dentin penetration. The adhesive failure mode was classified as adhesive, cohesive and mixed. Data were analysed by one-way ANOVA and Tukey tests (α = 5%). RESULTS: ARC-1 and ARC-12 showed the highest bond strength (P < 0.05). ARC showed the greatest tag extension, regardless of the third (P < 0.05). The most frequent failure mode in the 24-h analysis was cohesive, regardless of the cement used. For the 12-month analysis, mixed failure was the most frequent. CONCLUSION: Conventional cement (ARC) showed the highest bond strength and tag extension, regardless of the evaluation period. In all cementation systems, the bond strength decreased after 12 months. © 2023 Australian Dental Association.

6.
Imaging Sci Dent ; 53(2): 127-135, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37405202

RESUMO

Purpose: This study assessed the intensity of artifacts produced by 2 metal posts, 2 cements, and different exposure parameters using 2 cone-beam computed tomography (CBCT) units. Materials and Methods: The sample was composed of 20 single-rooted premolars, divided into 4 groups: Ni-Cr/zinc phosphate, Ni-Cr/resin cement, Ag-Pd/zinc phosphate, and Ag-Pd/resin cement. Samples were scanned before and after post insertion and cementation using a CS9000 3D scanner with 4 exposure parameters (85/90 kV and 6.3/10 mA) and an i-CAT scanner with 120 kV and 5 mA. The presence of artifacts was assessed subjectively by 2 observers and objectively by a trained observer using ImageJ software. The Mann-Whitney, Wilcoxon, weighted kappa, and chi-square tests were used to assess data at a 95% confidence level (α<0.05). Results: In the subjective analyses, AgPd presented more hypodense and hyperdense lines than NiCr (P<0.05), and more hypodense halos were found using i-CAT (P<0.05) than using CS9000 3D. More hypodense halos, hypodense lines, and hyperdense lines were observed at 10 mA than at 6.3 mA (P<0.05). More hypodense halos were observed at 85 kV than at 90 kV (P<0.05). CS9000 3D presented more hypodense and hyperdense lines than i-CAT (P<0.05). In the objective analyses, AgPd presented higher percentages of hyperdense and hypodense artifacts than NiCr (P<0.05). Zinc phosphate cement presented higher hyperdense artifact percentages on CS9000 3D scans (P<0.05). CS9000 3D presented higher artifact percentages than i-CAT (P<0.05). Conclusion: High-atomic-number alloys, higher tube current, and lower tube voltage may increase the artifacts present in CBCT images.

7.
Acta Odontol Latinoam ; 36(1): 40-46, 2023 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-37315311

RESUMO

During ceramic veneer luting, resin cement polymerization is performed with interposition of the dental ceramic. Aim: To evaluate how and how much the photoactivation time affects the Vickers hardness of resin-based cements with interposed ceramic. Materials and Method: A total 24 specimens H mm in diameter and 1 mm thick were made from Paracore White Coltene (PC), Densell Resin Duo Cement (DC), 3MRelyX Veneer (RX) and Coltene Fill Up! (FU), interposing VitablockMarkII (Vita Zahnfabrik) feldspathic ceramic 0.6 mm thick during photoactivation. The materials were polymerized using 100% and 25% of the times indicated by the manufacturers with a Coltolux LED ((Coltene) light with intensity 1200 mW/cm2. Each polymerization time group consisted of three specimens of each material, which were stored dry in darkness at 37 °C for 7 days. Three Vickers microhardness measurements were made on the top and bottom surfaces of each specimen using a Vickers Future Tech FM300 microhardness tester (300 g, 5 s). The values were averaged, and the bottom/top ratios calculated. Results were analyzed by ANOVA. (p<0.05) complemented with multiple comparisons using Tukey's test (p<0.05). Results: Different photoactivation times were found to have a significant effect on hardness values of the cements evaluated, with significant differences between some of the cements. No statistically significant difference was found for the effect of photoactivation time on bottom/top microhardness ratio in those materials. Conclusions: Under the experimental conditions employed, it can be concluded that photopolymerization for shorter times and the interposition of restorative material significantly affectpolymerization quality as evaluated by microhardness, but the bottom/top ratio was unaffected by differences in polymerization time.


Durante la fijación de una carilla cerámica, la polimerización del cemento a base de resinas se realiza con la interposición de la cerámica dental. Objetivo: evaluar en qué forma y magnitud afecta el tiempo de fotoactivación en la dureza Vickers de los cementos a base de resinas con la cerámica interpuesta. Materiales y Método: se confeccionaron 24 probetas de 11 mm de diámetro y 1 mm de espesor con: Paracore White Coltene (PC), Resin Duo Cement de Densell (DC), RelyX Veneer de 3M (RX) y Fill Up! De Coltene (FU) interponiendo 0,6 mm de espesor de cerámica feldespática Vitablock Mark II (Vita Zahnfabrik) durante la fotoactivación. Se polimerizó utilizando el 100% y el 25% del tiempo indicado por el fabricante con lámpara Coltolux LED ((Coltene) con 1200 mW/cm2 de intensidad. Cada grupo quedó conformado con tres probetas de cada material que se almacenaron a oscuras y en seco a 37 °C durante 7 días. Se registraron tres mediciones de microdureza Vickers de las superficies top y bottom de cada probeta con un microdurómetro Vickers Future Tech FM300 (300 g, 5 s) y se calculó su promedio, así como la relación entre los valores registrados en cada una de sus caras. Los resultados fueron analizados por medio de la prueba de ANOVA. (p<0.05). complementada con comparaciones múltiples por medio de la prueba de Tukey (p<0.05). Resultados: se encontró un efecto significativo de la modificación del tiempo de fotoactivación en los valores de dureza de los cementos evaluados con diferencias significativas entre algunos de ellos. Simultáneamente no se encontró significación estadística en el efecto de ese factor sobre la relación microdureza bottom/top registrada en esos materiales. Conclusiones: en las condiciones experimentales empleadas puede concluirse que la fotopolimerización en menor tiempo e interposición de material restaurador afecta significativamente la calidad de polimerización evaluada mediante los valores de microdureza, pero la proporción bottom/ top no fue afectada en la variación en el tiempo de polimerización.


Assuntos
Cerâmica , Cimentos de Resina , Materiais Dentários , Dureza , Polimerização
8.
J Biomed Mater Res B Appl Biomater ; 111(10): 1840-1852, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37287402

RESUMO

The objective of this study is to evaluate the effect of 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) and chitosan (CHI) on the adhesive interface of resin cements to root dentine. Forty-five upper canines were sectioned, endodontically treated, prepared and divided into three groups according to dentine treatment (distilled water-DW, CHI 0.2% and EDC 0.5) and in three subgroups according to resin cement: RelyX ARC, Panavia F 2.0 or RelyX U200. Slices were obtained, with five slices of each third submitted to the analysis of the adaptation of the adhesive interface through scores and the perimeter with gaps in confocal laser scanning microscopy and one slice of each third later evaluated qualitatively in scanning electron microscopy. The results were analyzed using with Kruskal-Wallis and Spearman correlation tests. There was no difference in adaptation for the different resin cements (p = .438). EDC presented better adaptation when compared to the groups treated with DW and CHI (p < .001), while the CHI and DW presented similar adaptation values (p = .365). No difference was observed in the perimeter referring to the gap areas for the different resin cements (p = .510). EDC showed a lower percentage of perimeters with gaps when compared to CHI (p < .001), with the percentage of perimeter with gaps of teeth treated with CHI being lower than DW (p < .001). A positive correlation coefficient equal to 0.763 was obtained between the perimeter with gaps and the adaptation data of the adhesive interface (p < .001). EDC resulted in better adaptation of the adhesive interface and a lower percentage of perimeters with gaps compared to chitosan.


Assuntos
Quitosana , Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos de Resina , Cimentação/métodos , Carbodi-Imidas , Dentina , Teste de Materiais
9.
Acta odontol. latinoam ; Acta odontol. latinoam;36(1): 40-46, Apr. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447074

RESUMO

ABSTRACT During ceramic veneer luting, resin cement polymerization is performed with interposition of the dental ceramic. Aim: To evaluate how and how much the photoactivation time affects the Vickers hardness of resin-based cements with interposed ceramic. Materials and Method: A total 24 specimens H mm in diameter and 1 mm thick were made from Paracore White Coltene (PC), Densell Resin Duo Cement (DC), 3MRelyX Veneer (RX) and Coltene Fill Up! (FU), interposing VitablockMarkII (Vita Zahnfabrik) feldspathic ceramic 0.6 mm thick during photoactivation. The materials were polymerized using 100% and 25% of the times indicated by the manufacturers with a Coltolux LED ((Coltene) light with intensity 1200 mW/cm2. Each polymerization time group consisted of three specimens of each material, which were stored dry in darkness at 37 °C for 7 days. Three Vickers microhardness measurements were made on the top and bottom surfaces of each specimen using a Vickers Future Tech FM300 microhardness tester (300 g, 5 s). The values were averaged, and the bottom/top ratios calculated. Results were analyzed by ANOVA. (p<0.05) complemented with multiple comparisons using Tukey's test (p<0.05). Results: Different photoactivation times were found to have a significant effect on hardness values of the cements evaluated, with significant differences between some of the cements. No statistically significant difference was found for the effect of photoactivation time on bottom/top microhardness ratio in those materials. Conclusions: Under the experimental conditions employed, it can be concluded that photopolymerization for shorter times and the interposition of restorative material significantly affectpolymerization quality as evaluated by microhardness, but the bottom/top ratio was unaffected by differences in polymerization time.


RESUMEN Durante la fijación de una carilla cerámica, la polimerización del cemento a base de resinas se realiza con la interposición de la cerámica dental. Objetivo: evaluar en qué forma y magnitud afecta el tiempo de fotoactivación en la dureza Vickers de los cementos a base de resinas con la cerámica interpuesta. Materiales y Método: se confeccionaron 24 probetas de 11 mm de diámetro y 1 mm de espesor con: Paracore White Coltene (PC), Resin Duo Cement de Densell (DC), RelyX Veneer de 3M (RX) y Fill Up! De Coltene (FU) interponiendo 0,6 mm de espesor de cerámica feldespática Vitablock Mark II (Vita Zahnfabrik) durante la fotoactivación. Se polimerizó utilizando el 100% y el 25% del tiempo indicado por el fabricante con lámpara Coltolux LED ((Coltene) con 1200 mW/cm2 de intensidad. Cada grupo quedó conformado con tres probetas de cada material que se almacenaron a oscuras y en seco a 37 °C durante 7 días. Se registraron tres mediciones de microdureza Vickers de las superficies top y bottom de cada probeta con un microdurómetro Vickers Future Tech FM300 (300 g, 5 s) y se calculó su promedio, así como la relación entre los valores registrados en cada una de sus caras. Los resultados fueron analizados por medio de la prueba de ANOVA. (p<0.05). complementada con comparaciones múltiples por medio de la prueba de Tukey (p<0.05). Resultados: se encontró un efecto significativo de la modificación del tiempo de fotoactivación en los valores de dureza de los cementos evaluados con diferencias significativas entre algunos de ellos. Simultáneamente no se encontró significación estadística en el efecto de ese factor sobre la relación microdureza bottom/top registrada en esos materiales. Conclusiones: en las condiciones experimentales empleadas puede concluirse que la fotopolimerización en menor tiempo e interposición de material restaurador afecta significativamente la calidad de polimerización evaluada mediante los valores de microdureza, pero la proporción bottom/ top no fue afectada en la variación en el tiempo de polimerización.

10.
Braz. dent. j ; Braz. dent. j;34(1): 52-60, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420568

RESUMO

Abstract This study evaluated the effect of aging and cementation of fiber posts using glass ionomer and resin cements on push-out bond strength, failure mode, and resin tag formation. One hundred and twenty bovine incisors were used. After post-space preparation, the specimens were randomly allocated into 12 groups (n = 10) according to the cementation system used: GC - GC Gold Label Luting & Lining); RL - RelyX Luting 2; MC - MaxCem Elite; RU - RelyX U200 and the aging periods (24 hours, 6 months, and 12 months). Slices from the cervical, middle, and apical thirds were obtained and analyzed by push-out bond strength test and confocal laser scanning microscopy. One-way ANOVA and Tukey's post-hoc test was used at a significance level of 5%. For the push-out bond strength test, no differences among GC, RU, and MC in the cervical and middle thirds were observed, regardless of the period of storage (P > 0.05). In the apical third, GC and RU showed similar bond strength but higher than other groups (P > 0.05). After 12 months, GC showed the highest bond strength (P < 0.05). Bond strength to post-space dentin decreased over time, regardless of the cementation system used. Cohesive failure was the most frequent, regardless of the period of storage, cementation system, and post-space third. Tag formation was similar among all groups. After 12 months, GC showed the highest bond strength values.


Resumo Avaliar o efeito do envelhecimento e sistemas de cimentação usando ionômero de vidro e cimentos resinosos na resistência de união à dentina após a cimentação do pino de fibra. Cento e vinte incisivos bovinos foram utilizados. Após o preparo do pós-espaço, os corpos de prova foram distribuídos aleatoriamente em 12 grupos (n = 10) de acordo com o período de envelhecimento (24 horas, 6 meses e 12 meses) e o sistema de cimentação utilizado: GC - cimento de ionômero de vidro (GC Gold Label Cimentação e Revestimento); RL - RelyX Luting 2; MC - MaxCem Elite; RU - RelyX U200. Cortes dos terços cervical, médio e apical foram obtidos e analisados por teste de resistência de união push-out e microscopia confocal de varredura a laser. ANOVA one-way e teste de Tukey foi usado a um nível de significância de 5%. Para o teste de resistência de união, não foram observadas diferenças entre GC, RU e MC nos terços cervical e médio, independentemente do período de armazenamento (P > 0,05). No terço apical, GC e RU apresentaram resistência de união semelhante, porém superior aos demais grupos (P > 0,05). Após 12 meses, o GC apresentou a maior resistência de união (P < 0,05). A resistência de união à dentina no espaço para pino diminuiu ao longo do tempo, independentemente do sistema de cimentação utilizado. A formação de tags foi semelhante entre todos os grupos. Após 12 meses, o GC apresentou os maiores valores de resistência de união.

11.
Braz. oral res. (Online) ; 37: e42, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1430032

RESUMO

Abstract The purpose of this study was to evaluate the effect of dentin moisture (moist and dry) on the bonding of fiber posts to root dentin with different adhesive strategies (etch-and-rinse, self-etch, and self-adhesive). Seventy-two extracted single-rooted human teeth were endodontically treated and divided into six groups (n = 12) according to the moisture of dentin surface and adhesive systems as follows: a) etch-and-rinse/moist, b) etch-and-rinse/dry, c) self-etch/moist, d) self-etch/dry, e) self-adhesive/moist, and 6) self-adhesive/dry. The specimens were sectioned into six slices for push-out bond strength (BS), nanoleakage (NL) by SEM, and Vickers microhardness (VHN) of the resin cement. A universal testing machine (AG-I, Shimadzu Autograph) was used at a crosshead speed of 0.5 mm/min until post extrusion, with a load cell of 50 kg for evaluation of the push-out strength. Data on BS, NL, and VHN were evaluated by two-way ANOVA and Tukey's test (α = 0.05). Dentin moisture as the main factor was not significantly different for the push-out test. However, higher BS values can be observed for the etch-and-rinse group. A lower percentage of NL was found in the dry dentin groups. The moisture pattern was not significant in the hardness values for the pre-etching groups. Additional moisture did not increase the evaluated properties.

12.
J. appl. oral sci ; J. appl. oral sci;31: e20230005, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1440411

RESUMO

Abstract Irrigation solutions might affect dentin surface characteristics and, consequently, endodontic sealers adhesion. Objective This study analyzed the effect of different final irrigation protocols on push-out bond strength (BS) of AH Plus to dentin seven days and 20 months after obturation. Scanning electron micrographs were obtained from the dentin surface of one sample/group after final irrigation. Methodology Canals of bovine incisors were instrumented and received final irrigation with (n=21): G1 - 2.5% sodium hypochlorite (NaOCl) + distilled water; G2 - 2.5% NaOCl + 17% EDTA; G3 - 2.5% NaOCl + 17% EDTA + 2.5% NaOCl; G4 - 2.5% NaOCl + 17% EDTA + 2% chlorhexidine (CHX); G5 - mixture 5% NaOCl + 18% etidronate (HEDP); and G6 - mixture 5% NaOCl + 10% tetrasodium EDTA (Na4EDTA). After irrigation, one root/group was split and images were obtained by scanning electron microscopy (SEM). The other 20 roots/group were filled with only AH Plus sealer. Three slices/root were used for push-out assessment seven days and 20 months after obturation. One-way analysis of variance and Tukey (α<0.05) were used to compare the results among experimental groups, and unpaired t-test (α<0.05) was used to compare the results of the same group over time. Results The photomicrographs showed that, excepting G1, all groups completely removed the smear layer from the samples. In G2 and G4, the opening of the dentin tubules enlarged. In G3, erosion was observed in the peritubular and intertubular dentin. Values of the BS in the seven days were G2=G3=G4=G5>G6=G1 and in the 20 months were G3=G5>G6=G4>G1=G2. G3, G5, and G6 presented values of BS in 20 months similar to the values of seven days (P>0.05). Conclusions The final irrigation protocols tested produced dentin surfaces with different characteristics. Only G3 and G5 presented high BS values that were stable over time.

13.
Braz. j. oral sci ; 22: e231336, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1442820

RESUMO

Aim: To investigate and compare the effects of different thicknesses of medium-translucency monolithic zirconia and light curing times on the polymerization of two types of dual-cured resin cement. Methods: A total of 200 cement specimens were prepared from TheraCem and RelyX U200 cement. The specimens were divided into 5 groups: Group I, without interposing zirconia; Group II, 0.50 mm thickness; Group III, 1.00 mm; Group IV, 1.50 mm; and Group V, 2.00 mm thickness. Each group was subdivided into (1) RelyX U200 and (2) TheraCem. Each subgroup was subdivided according to the light-curing time into (a) 20 s and (b) 40 s (n =5). The polymerization was tested using Fourier-transform infrared (FTIR) spectroscopy and a Vickers microhardness tester. The data were statistically analyzed using ANOVA, an independent sample t-test, and Tukey's test at a significance level of 0.05. Results: The control group had the highest values of DC and VMH, followed by 0.50, 1.00, and 1.50 mm, respectively, while the 2.00 mm group showed the lowest values. The specimens irradiated for 40 s had greater DC and VMH than those irradiated for 20 s. RelyX U200 revealed higher values for both parameters compared to TheraCem cement. Conclusion: The polymerization of selfadhesive cement depends on the thickness of the monolithic zirconia, the light curing time, and the composition of the cement. The cement should be irradiated for a longer period than recommended to overcome the light attenuation of zirconia. TEGDMA-based self-adhesive cement showed a higher DC and VMH than BISGMA-based cement


Assuntos
Zircônio , Espectroscopia de Infravermelho com Transformada de Fourier , Cimentos de Resina , Polimerização
14.
Braz. j. oral sci ; 22: e230130, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1442841

RESUMO

Aim: This study assessed the effect of thermal aging on the interfacial strength of resin cements to surface-treated PEEK. Methods: Ninety-six PEEK blocks were allocated into 4 groups (n=24), according to following surface treatments: SB - sandblasting with aluminum oxide; SA - acid etched with 98% sulfuric acid; CA ­ coupling agent (Visio.link, Bredent) and CO - control group (untreated). Surface roughness (Ra) was measured and one cylinder (1-mm diameter and height) of Rely-X Ultimate - ULT (3M/ESPE) and another one of Panavia V5 - PAN (Kuraray) were constructed on the treated or untreated PEEK surfaces. Half of the samples of each group were thermal aged (1,000 cycles). Samples were tested at a crosshead speed of 1 mm/min in shear mode (µSBS). Ra and µSBS data were compared using one- and three-way ANOVA, respectively, and Tukey's tests. Results: SA and SB samples had the roughest surfaces, while CA the smoother (p<0.001). Thermal aging reduced µSBS regardless the surface treatment and resin cement used. There was interaction between surface treatment and resin cement (p <0.001), with ULT showing higher µSBS values than PAN. SA provided higher µSBS than SB for both resin cements, while for CA µSBS was higher (PAN) or lower than SB (ULT). Conclusion: Aging inadvertently reduces interfacial strength between PEEK and the resin cements. If ULT is the resin cement of choice, reliable interfacial strength is reached after any PEEK surface treatment. However, if PAN is going to be used only SA and CA are recommended as PEEK treatment


Assuntos
Polímeros , Envelhecimento , Cimentos de Resina , Resistência ao Cisalhamento
15.
Braz. j. oral sci ; 22: e239389, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1509457

RESUMO

Aim: The purpose of this study was to investigate the biofilm effect on the hybrid ceramic-resin cement bond strength (BS) by comparing two methods. Methods: Teeth were distributed into groups (n=5), according to the resin cement (Maxcem Elite-(MC) or NX3 Nexus-(NX)) and degradation method (24h or 7 days in distilled water; 7 or 30 days incubated with biofilm and 30 days in sterile media). Treated surfaces of Vita Enamic blocks (5x6x7mm) were luted to treated or no treated dentin surfaces and light-cured. After 24h, beams were obtained (1x1x10mm) and stored accordingly. The flexural bond strength (FBS) was assessed by four-point bending test. Additional beams were obtained from new teeth (n=5), stored for 24h or 7 days in distilled water, and submitted to a microtensile bond strength (µTBS) assay. Failure modes were determined by scanning electron microscopy (100X). The flexure strength of the cements (n=10) was assessed by a four-point bending test. Data were analyzed by 1 and 2-ways ANOVA, and Tukey's test (α=0.05). Results: There was no significant difference between the degradation methods for the FBS groups. For the µTBS, the significant difference was as follows: NX 7days > NX 24h > MC 7days = MC 24h. Failure mode was mainly adhesive and mixed, but with an increase of cohesive within cement and pre-failures for the MC groups assessed by µTBS. NX had better performance than MC, regardless of the method. Conclusions: The biofilm had no effect on the materials BS and FBS test was a useful method to evaluate BS of materials with poor performance


Assuntos
Resistência à Tração , Microscopia Eletrônica de Varredura , Colagem Dentária , Biofilmes , Cimentos de Resina
16.
Materials (Basel) ; 15(17)2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-36079385

RESUMO

This in vitro study aimed to evaluate the effect of different bonding strategies on the micro-shear bond strength (µSBS) of luting agents to CAD−CAM composites. Surface scanning electron microscopy (SEM) and spectroscopy by energy-dispersive X-ray spectroscopy (EDS) were performed to analyze the surfaces of the composite before and after bonding treatment. Three CAD−CAM composites were evaluated: Lava Ultimate restorative (LU), Brava Blocks (BR), and Vita Enamic (VE). The LU and BR surfaces were sandblasted using aluminum oxide, while the VE surfaces were etched using a 5% hydrofluoric acid gel according to the manufacturers' recommendations. All surfaces were subjected to the following bonding strategies (n = 15): adhesive with silane and MDP (ScotchBond Universal, 3M Oral Care, St Paul, MI, USA); adhesive with MDP (Ambar Universal, FGM, Joinville, Brazil); adhesive without silane or MDP (Prime&Bond Elect, Dentsply Sirona, Charlotte, NC, USA), pure silane without MDP (Angelus, Londrina, Brazil), and pure silane with MDP (Monobond N, Ivoclar Vivadent, Schaan, Liechtenstei). Afterwards, tygons were filled with RelyX Ultimate (3M Oral Care), AllCem (FGM), or Enforce (Dentsply Sirona), which were light-cured and subjected to the µSBS test. Data were analyzed using two-way ANOVA and Bonferroni's post hoc test (α = 0.05). Additional blocks (n = 15) were subjected to scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) before and after the surface treatment. The µSBS values on VE surfaces were higher than those observed on LU and BR surfaces (p < 0.001). Silane without MDP (Allcem) promoted the highest µSBS values, while silane with MDP (RelyX Ultimate) provided the highest values among all bonding strategies (p < 0.001). Enforce promoted no significant difference in µSBS values. SEM and EDS analyses detected noticeable changes to the surface morphology and composition after the surface treatment. The effectiveness of the bonding strategy may vary according not only to the CAD−CAM composite but also to resin cement/bonding agent/silane used.

17.
Restor Dent Endod ; 47(3): e32, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36090509

RESUMO

Objectives: This study aimed to evaluate the influence of inorganic composition and filler particle morphology on the mechanical properties of different self-adhesive resin cements (SARCs). Materials and Methods: Three SARCs including RelyX Unicem-2 (RUN), Maxcem Elite (MAX), and Calibra Universal (CAL) were tested. Rectangular bar-shaped specimens were prepared for flexural strength (FS) and flexural modulus (FM) and determined by a 3-point bending test. The Knoop microhardness (KHN) and top/bottom microhardness ratio (%KHN) were conducted on the top and bottom faces of disc-shaped samples. Sorption (Wsp) and solubility (Wsl) were evaluated after 24 hours of water immersion. Filler morphology was analyzed by scanning electron microscopy and X-ray energy dispersive spectroscopy (EDS). FS, FM, %KHN, Wsp, Wsl, and EDS results were submitted to 1-way analysis of variance and Tukey's post-hoc test, and KHN also to paired t-test (α = 0.05). Results: SARC-CAL presented the highest FS value, and SARC-RUN presented the highest FM. SARC-MAX and RUN showed the lowest Wsp and Wsl values. KHN values decreased from top to bottom and the SARCs did not differ statistically. Also, all resin cements presented carbon, aluminum, and silica in their composition. SARC-MAX and RUN showed irregular and splintered particles while CAL presented small and regular size particles. Conclusions: A higher mechanical strength can be achieved by a reduced spread in grit size and the filler morphology can influence the KHN, as well as photoinitiators in the composition. Wsp and Wsl can be correlated with ions diffusion of inorganic particles.

18.
J Contemp Dent Pract ; 23(4): 388-392, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35945830

RESUMO

AIM: To assess dentin-post bond strength and mode of failure through tensile strength testing of two endodontic post systems: CAD/CAM custom-milled fiber posts vs Splendor SAP. MATERIALS AND METHODS: Thirty extracted single-rooted mandibular premolars were sectioned 2 mm coronal to the cementoenamel junction. Root length was standardized at 15 mm, and the root canals were instrumented with #20 K-files followed by 30/0.03 and 30/0.05 ProDesign Logic rotary files, under irrigation with 2.5% NaOCl, and then submitted to final irrigation with 17% EDTA. Canals were filled with gutta-percha and AH PLUS sealer. After 24 hours, the teeth were prepared for post placement to a depth of 10 mm and randomly allocated into two experimental groups (n = 15): CAD/CAM (CC) and Splendor SAP (SS). All posts were cemented with RelyX U200 dual-cure self-adhesive resin cement. The roots were embedded in acrylic resin, and the specimens were stored for 7 days in moist heat (37°C). Tensile strength testing until failure was then performed in a universal testing machine using a crosshead speed of 0.5 mm/minute. The final failure load was tabulated for statistical analysis, and the G test was used to compare the failure modes observed under light microscopy (5× magnification). RESULTS: There was no significant difference between groups regarding tensile bond strength to root dentin (p = 0.325). Conversely, failure mode differed significantly between groups (p = 0.037). CONCLUSION: The tensile bond strength observed for the CAD/CAM and Splendor SAP post systems was similar. Adhesive failure was predominant in both groups; however, the CAD/CAM custom-milled fiber posts failed predominantly at the dentin-resin cement interface, whereas Splendor SAP posts failed mostly at the post-resin cement interface. CLINICAL SIGNIFICANCE: A strong post-dentin bond is a key to the success of dental restorations and prosthetic rehabilitation. In teeth with severe coronal decay and wide canals, both of the tested systems would be able to achieve good cervical fit.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Desenho Assistido por Computador , Cavidade Pulpar , Análise do Estresse Dentário , Dentina , Teste de Materiais , Cimentos de Resina/química
19.
Bioengineering (Basel) ; 9(8)2022 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-36004897

RESUMO

The sealing and bonding characteristics of luting cements may be affected by the application of desensitizers containing ingredients that induce chemical interaction with dentin organic matrix. This study evaluated the effect of different desensitizers on the immediate and long-term shear bond strength (SBS) of a self-adhesive resin cement (SARC) to dentin. Healthy bovine dentin specimens were used for the study. Gluma® Desensitizer, Desensibilize Nano P®, and Soothe® desensitizer were used in study groups, while the control group did not receive any treatment. Next, SARC (RelyXTM U200) in cylindrical mold was applied to the sample surface. All specimens were stored at 37 °C for 24 h or six months and tested for SBS. Additionally, water contact angle was measured using an optical tensiometer. Results were analyzed by analysis of variance and Student-t tests (p ˂ 0.05). Application of the different types of desensitizers had no significant influence on immediate or long-term SBS of SARC to dentin (p > 0.05). Differences for water contact angle were not statistically significant among the tested groups (p = 0.450). Within the limitations of the present study, it can be concluded that the application of the different types of desensitizers had no significant influence on the SBS of a SARC to dentin.

20.
J Esthet Restor Dent ; 34(7): 1051-1059, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35644927

RESUMO

OBJECTIVES: To evaluate the influence of dentin pretreatments on the push-out bond strength (POBS) of self-adhesive resin cements (SARCs) to radicular dentin. MATERIALS AND METHODS: Two experimental pretreatments (2.5% titanium tetrafluoride (TiF4 ) and 26% polyacrylic acid (PA)) and two SARCs: Maxcem Elite (MAX) and Calibra Universal (CAL) were used. For each cement, a control group was applied as indicated by the manufacturer. Sixty bovine incisors were restored (n = 10) and subjected to POBS evaluation. Failure mode, adhesive interface and surface morphology were analyzed by a Scanning Electron Microscopy (SEM) and resin infiltration was performed by confocal laser scanning microscopy (CLSM). Data for POBS and CLSM were analyzed by three-way ANOVA and Bonferroni post-hoc (α = 0.05). RESULTS: For MAX, both experimental pretreatments resulted in increased POBS in the cervical third, and for CAL, only the PA resulted in higher POBS in the cervical third. The most failures occurred between the dentin and the resin cement, except when TiF4 was applied. For PA, analysis of surface morphology showed open dentinal tubules, while TiF4 presented particle agglomerates. SEM and CLSM images confirmed presence of resin tags for both pretreatments. CONCLUSION: Pretreating radicular dentin with PA and TiF4 solutions improves the bond strength of SARCs.


Assuntos
Colagem Dentária , Cimentos de Resina , Animais , Bovinos , Colagem Dentária/métodos , Cimentos Dentários/química , Análise do Estresse Dentário , Dentina , Adesivos Dentinários/química , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA