Rev. cuba. ortop. traumatol ; 35(2): e344, 2021. ilus, tab
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1341469

RESUMO

Introducción: La luxación de la prótesis total de cadera puede afectar los resultados del implante, la calidad de vida del paciente, y el costo del proceso. Su etiología es multifactorial. Objetivos: Identificar posibles factores de riesgo relacionados con la aparición de luxación en prótesis total de cadera en una serie de casos. Métodos: En una serie de 2732 prótesis total de cadera, en la que hubo 92 luxaciones (3,4 por ciento), se compararon factores relacionados con el paciente, el implante, y la técnica quirúrgica uilizada en el Hospital La Paz-IDIPaz de Madrid entre los años 2000 y 2016. Se utilizó el análisis de regresión para la significación de dichos factores. Resultados: De las 92 luxaciones, 62 fueron tratadas de manera conservadora (67,4 por ciento) y 30 pacientes precisaron de cirugía de revisión (32,6 por ciento). El estudio multivariado mostró significación estadística en los siguientes factores de riesgo: estado de la columna lumbar (p < 0,001), y una pobre reconstrucción del centro de rotación de la cadera (p= 0,035), y cúpulas posicionadas fuera de las ventanas de Lewinnek (p < 0,001) y del mecanismo abductor (p < 0,001) en relación con la técnica quirúrgica. No hubo factores significativos en relación con el tipo de implante, diámetro de la cabeza femoral o par de fricción. Conclusiones: La patología lumbar aumenta el riesgo de luxación en la prótesis total de cadera. Una adecuada reconstrucción de la cadera, que incluya la posición de la cúpula y el centro de rotación de la cadera, así como del mecanismo abductor ayudaría a mejorar la tasa de inestabilidad(AU)


Introduction: The dislocation of the total hip replacement can affect the results of the implant, the quality of life of the patient, and the cost of the process. Its etiology is multifactorial. Objectives: To identify possible risk factors related to the appearance of dislocation in total hip replacement in a series of cases. Methods: In a series of 2732 total hip prostheses, in which there were 92 dislocations (3.4percent), factors related to the patient, the implant, and the surgical technique used at La Paz-IDIPaz Hospital in Madrid were compared, from 2000 to 2016. Regression analysis was used for the significance of these factors. Results: Out of 92 dislocations, 62 were treated conservatively (67.4 percent) and 30 patients required revision surgery (32.6 pecent). The multivariate study showed statistical significance in the following risk factors: state of the lumbar spine (p <0.001), and poor reconstruction of the center of rotation of the hip (p = 0.035), and domes positioned outside Lewinnek windows (p <0.001) and the abductor mechanism (p <0.001) in relation to the surgical technique. There were no significant factors in relation to the type of implant, diameter of the femoral head or friction torque. Conclusions: Lumbar pathology increases the risk of dislocation in total hip replacement. Proper hip reconstruction, including the position of the dome and the center of rotation of the hip, as well as the abductor mechanism, would help to improve the rate of instability(AU)


Assuntos
Humanos , Masculino , Feminino , Fatores de Risco , Artroplastia de Quadril/métodos , Luxações Articulares/etiologia
2.
Rev. chil. ortop. traumatol ; 52(2): 101-111, 2011. ilus
Artigo em Espanhol | LILACS | ID: lil-609929

RESUMO

Objectives: To evaluate short-term clinical results of patients performed acetabular revision surgery using a Trabecular Tantalum coated modular acetabular cups. Materials and Methods: This is a retrospective and descriptive analysis of a serie of 32 consecutive patients (34 hips) with acetabular revision surgery (23 women, 9 men, mean age 70.7 years), mean follow-up 32 month (12-60). The Paprosky and the AAOS acetabular defects classifications were assessed. According to Paprosky acetabular defects classification, there were eleven type I, two IIA, three IIB, nine IIC, seven IIIA and two IIIB. According to AAOS acetabular defects classification there were thirteen patients with type 1, nine patients with type 2, ten type 3 and two type 4. The percentage of own acetabular bone in contact with the new cup was recorded for each patient at the time of surgery and was 45 percent (range from 20 to 80 percent), with 23 patients presenting less than 50 percent of bone contact (mean 35 percent). Postoperatively, osseous integration was radiographically assessed. Functional results were evaluated according to the Harris Hip Score (HSS). The complications related to the implant were also recorded. Results: In all radiographic assessments performed at 3, 6 and 12 month postoperatively an integrated cup without signs of migration or osteolysis was observed. Four patients (11.8 percent) presented recurrent hip dislocation that required a revision surgery without further cup revision. The final clinical assessment was performed at a mean of 26 month after surgery (12-60) with a mean HHS of 91.8 points. Conclusion: Trabecular tantalum coated modular acetabular cups in acetabular revision surgery shows good short term clinical results even with acetabular defects greater than 50 percent. No cup loosening was observed in these series.


Objetivo: Evaluar los resultados clínicos a corto plazo de pacientes sometidos a cirugía de revisión acetabular utilizando cotilos modulares con superficie de metal trabecular de tantalio. Material y Métodos: Estudio retrospectivo-descriptivo de una serie consecutiva de 32 pacientes (34 caderas) sometidos a cirugía de revisión acetabular (23 mujeres, 9 hombres, edad promedio 70,7 años), seguimiento promedio 32 meses (12-60). Se clasifican los defectos acetabulares de acuerdo ala clasificación de Paprosky y de la AAOS. Según la clasificación de Paprosky de los defectos acetabulares, 11 pacientes tenían categoría I, 2 categoría IIA, 3 categoría IIB, 9 categoría IIC, 7 categoría IIIA y 2 categoría IIIB. Según la clasificación de la AAOS, 13 pacientes correspondieron a nivel 1, 9 pacientes a nivel 2, 10 a nivel 3 y 2 a nivel 4. Se registra el porcentaje de hueso propio acetabular en contacto con el nuevo cotilo de cada paciente que fue en promedio 45 por ciento (20-80 por ciento), presentándose en 23 caderas un porcentaje < 50 por ciento, el cual fue en promedio 35 por ciento. En el postoperatorio se evalúa la integración ósea mediante radiografías de pelvis. Se evalúan los resultados funcionales mediante el HHS (Harris Hip Score) y las complicaciones postoperatorias relacionadas con el implante. Resultados: En todas las radiografías postoperatorias realizadas a los 3, 6 y 12 meses se evidenciaba el cotilo integrado, sin signos de migración ni osteolisis. Cuatro pacientes (11,8 por ciento) presentaron luxaciones recidivantes de cadera, las cuales requirieron de una cirugía de revisión sin recambio del cotilo. La última evaluación clínica fue en promedio 26 meses tras la cirugía (12-60 meses) constatándose un HHS promedio de 91,8 puntos. Conclusión: El uso de cotilos modulares con revestimiento de metal trabecular de tantalio en cirugías de revisión acetabular presenta buenos resultados clínicos a corto plazo incluso en defectos óseos acetabulares superiores...


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Acetábulo , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Prótese de Quadril , Tantálio/uso terapêutico , Seguimentos , Osseointegração , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento